Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Endoscopy ; 47(6): 525-8, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25590177

RESUMEN

BACKGROUND AND STUDY AIMS: We developed a novel magnetic-controlled capsule endoscopy (MCE) system for use in the human stomach. The aim of the current study was to compare the diagnostic accuracy of MCE with that of standard gastroscopy for gastric diseases. PATIENTS AND METHODS: A total of 68 patients were enrolled in this self-controlled trial. Patients were evaluated by both MCE and gastroscopy. Gastroscopy was performed 4 ­â€Š24 hours after completion of the MCE examination. RESULTS: The positive percent agreement between MCE and gastroscopy was 96.0 %, and the negative percent agreement was 77.8 %. The overall agreement was 91.2 % with a kappa value of 0.765 (P < 0.001). A total of 68 pathological findings were detected, of which 53 were identified by both methods. The MCE and standard gastroscopy missed seven and eight findings, respectively. CONCLUSIONS: MCE showed a diagnostic accuracy similar to that of standard gastroscopy. These results suggest that MCE is a promising alternative to gastroscopy for noninvasive screening of gastric diseases.Clinical trial registration number: NCT01903629.


Asunto(s)
Endoscopía Capsular/métodos , Gastroscopía , Magnetismo , Gastropatías/diagnóstico , Adulto , Anciano , Endoscopía Capsular/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad
2.
BMJ Open ; 3(9): e003150, 2013 09 03.
Artículo en Inglés | MEDLINE | ID: mdl-24002981

RESUMEN

OBJECTIVE: Genetic alterations may contribute to chronic pancreatitis (CP) in Chinese young patients. This study was designed to investigate mutations of cationic trypsinogen (PRSS1), pancreatic secretory trypsin inhibitor or serine protease inhibitor Kazal type 1 (SPINK1), cystic fibrosis transmembrane conductance regulator (CFTR), chymotrypsin C (CTRC) and CLDN2 genes and the copy number variations (CNVs) of PRSS1 and asses associations with the development of idiopathic CP (ICP) in Chinese children. DESIGN: Retrospective. SETTING: A single center. PARTICIPANTS: 75 ICP Chinese children (40 boys and 35 girls). PRIMARY AND SECONDARY OUTCOME MEASURES: Mutations of PRSS1, SPINK1, CFTR, CTRC and CLDN2 genes and CNVs. RESULTS: 7 patients had heterozygous mutations in PRSS1, that is, N29I (n=1), R122H or R122C (n=6). The CNVs of PRSS1 in five patients had abnormal copies (1 copy (n=4), five copies (n=1)). 43 patients had IVS3+2T>C (rs148954387) (10 homozygous and 33 heterozygous) in SPINK1. None of the PRSS1 mutation patients carried a SPINK1 mutation. Frequency of PRSS1 and SPINK1 mutations was 9.3% and 57.3%, respectively, with an overall frequency of 66.6% (50/75). In addition, one patient had a novel deletion of CFTR (GCTTCCTA from c.500 to c.508 leading to the shortened polypeptide molecule via a stop codon). Another patient had a novel missense in CLDN2 exon 2 (c.592A>C mutation). Clinically, patients with SPINK1 mutations had a higher rate of pancreatic duct stones, pancreatic pseudocyst and pancreatic calcification than those without SPINK1 mutations (p<0.05). CONCLUSIONS: SPINK1 mutations were more commonly associated with Chinese children with ICP. SPINK1 IVS3+2T>C mutation may play an important role in the pathogenesis of Chinese paediatric ICP. However, further study is needed to confirm and to investigate the role of these genes in the development of Chinese ICP.

3.
J Interv Gastroenterol ; 2(4): 155-160, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23687601

RESUMEN

OBJECTIVE: To assess the feasibility and safety of magnetic-controlled capsule endoscopy (MCE) system for examination of human stomach. METHODS: This pilot study enrolled 34 healthy volunteers. All subjects swallowed the MCE and gas-producing powder for gastric distention. An external robot was used to generate magnetic field to manipulate MCE inside the stomach. The primary measurements included safety, gastric preparation, maneuverability and visualization of gastric mucosa. RESULTS: Gastric preparation and examination was well accepted by subjects and there were no adverse events. The examination in the stomach takes 43.8±10.0min (27-60). The cleanliness was evaluated as good in the 30 (88.2%) subjects and as moderate in 4 (11.8%) subjects. The distention of gastric cavity was evaluated as good in the 29 (85.3%) subjects and moderate in 5 (14.7%) subjects. Maneuverability of the MCE to movements of the guidance magnet robot was graded as good in 29 (85.3%) subjects and moderate in 5 (14.7%) subjects. More than 75% gastric mucosa was visualized in 27 (79.4%) subjects and 50% to 75% in 7 (20.6%) subjects. Visualization of the gastric cardia, fundus, body, angulus, antrum and pylorus was subjectively assessed as complete in 82.4%, 85.3%, 100.0%, 100.0%, 100.0% and 100.0%, respectively. Polyp and erosive lesions were found in 7 subjects. CONCLUSION: Magnetic-controlled capsule endoscopy used for examination of the human stomach is feasible and safe.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA