J Cardiovasc Electrophysiol ; 35(3): 379-388, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38185855

RESUMEN

BACKGROUND: The mechanism of typical slow-fast atrioventricular nodal re-entrant tachycardia (AVNRT) and its anatomical and electrophysiological circuit inside the right atrium (RA) and Koch's Triangle (KT) are not well known. OBJECTIVE: To identify the potentials of the compact AV node and inferior extensions and to perform accurate mapping of the RA and KT in sinus rhythm (SR) and during AVNRT, to define the tachycardia circuit. METHODS: Consecutive patients with typical AVNRT were enrolled in 12 Italian centers and underwent mapping and ablation by means of a basket catheter with small electrode spacing for ultrahigh-density mapping and a modified signal-filtering toolset to record the potentials of the AV nodal structures. RESULTS: Forty-five consecutive cases of successful ablation of typical slow-fast AVNRT were included. The mean SR cycle length (CL) was 784.1 ± 6 ms and the mean tachycardia CL was 361.2 ± 54 ms. The AV node potential had a significantly shorter duration and higher amplitude in sinus rhythm than during tachycardia (60 ± 40 ms vs. 160 ± 40 ms, p < .001 and 0.3 ± 0.2 mV vs. 0.09 ± 0.12 mV, p < .001, respectively). The nodal potential duration extension was 169.4 ± 31 ms, resulting in a time-window coverage of 47.6 ± 9%. The recording of AV nodal structure potentials enabled us to obtain 100% coverage of the tachycardia CL during slow-fast AVNRT. CONCLUSION: Detailed recording of the potentials of nodal structures is possible by means of multipolar catheters for ultrahigh-density mapping, allowing 100% of the AVNRT CL to be covered. These results also have clinical implications for the ablation of right-septal and para-septal arrhythmias.


Asunto(s)
Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Nodo Atrioventricular/cirugía , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos , Electrodos
2.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38291778

RESUMEN

AIMS: To predict worsening heart failure hospitalizations (WHFHs) in patients with implantable defibrillators and remote monitoring, the HeartInsight algorithm (Biotronik, Berlin, Germany) calculates a heart failure (HF) score combining seven physiologic parameters: 24 h heart rate (HR), nocturnal HR, HR variability, atrial tachyarrhythmia, ventricular extrasystoles, patient activity, and thoracic impedance. We compared temporal trends of the HF score and its components 12 weeks before a WHFH with 12-week trends in patients without WHFH, to assess whether trends indicate deteriorating HF regardless of alert status. METHODS AND RESULTS: Data from nine clinical trials were pooled, including 2050 patients with a defibrillator capable of atrial sensing, ejection fraction ≤ 35%, NYHA class II/III, no long-standing atrial fibrillation, and 369 WHFH from 259 patients. The mean HF score was higher in the WHFH group than in the no WHFH group (42.3 ± 26.1 vs. 30.7 ± 20.6, P < 0.001) already at the beginning of 12 weeks. The mean HF score further increased to 51.6 ± 26.8 until WHFH (+22% vs. no WHFH group, P = 0.003). As compared to the no WHFH group, the algorithm components either were already higher 12 weeks before WHFH (24 h HR, HR variability, thoracic impedance) or significantly increased until WHFH (nocturnal HR, atrial tachyarrhythmia, ventricular extrasystoles, patient activity). CONCLUSION: The HF score was significantly higher at, and further increased during 12 weeks before WHFH, as compared to the no WHFH group, with seven components showing different behaviour and contribution. Temporal trends of HF score may serve as a quantitative estimate of HF condition and evolution prior to WHFH.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Hospitalización , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Complejos Cardíacos Prematuros
3.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37490349

RESUMEN

AIMS: After an ischaemic stroke, atrial fibrillation (AF) detection allows for improved secondary prevention strategies. This study aimed to compare AF detection and oral anticoagulant (OAC) initiation in patients with an insertable cardiac monitor (ICM) vs. external cardiac monitor (ECM) after ischaemic stroke. METHODS AND RESULTS: Medicare Fee-for-Service (FFS) insurance claims and Abbott Labs device registration data were used to identify patients hospitalized with an ischaemic stroke in 2017-2019 who received an ICM or ECM within 3 months. Patients with continuous Medicare FFS insurance and prescription drug enrolment in the prior year were included. Patients with prior AF, atrial flutter, cardiac devices, or OAC were excluded. Insertable cardiac monitor and ECM patients were propensity score matched 1:4 on demographics, comorbidities, and stroke hospitalization characteristics. The outcomes of interest were AF detection and OAC initiation evaluated with Kaplan-Meier and Cox proportional hazard regression analyses. A total of 5702 Medicare beneficiaries (ICM, n = 444; ECM, n = 5258) met inclusion criteria. The matched cohort consisted of 2210 Medicare beneficiaries (ICM, n = 442; ECM, n = 1768) with 53% female, mean age 75 years, and mean CHA2DS2-VASc score 4.6 (1.6). Insertable cardiac monitor use was associated with a higher probability of AF detection [(hazard ratio (HR) 2.88, 95% confidence interval (CI) (2.31, 3.59)] and OAC initiation [HR 2.91, CI (2.28, 3.72)] compared to patients monitored only with ECM. CONCLUSION: Patients with an ischaemic stroke monitored with an ICM were almost three times more likely to be diagnosed with AF and to be prescribed OAC compared to patients who received ECM only.


Asunto(s)
Fibrilación Atrial , Isquemia Encefálica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Femenino , Anciano , Estados Unidos/epidemiología , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/epidemiología , Isquemia Encefálica/prevención & control , Medicare , Anticoagulantes/efectos adversos , Prescripciones
4.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37536671

RESUMEN

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Cardiomiopatías , Canalopatías , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Canalopatías/complicaciones , Canalopatías/terapia , Resultado del Tratamiento , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Cardiomiopatías/complicaciones , Cardiomiopatías/terapia , Sistema de Registros
5.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36932709

RESUMEN

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Desfibriladores Implantables/efectos adversos , Taquicardia Ventricular/diagnóstico , Estudios de Seguimiento , Estudios Prospectivos , Cardioversión Eléctrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
6.
Europace ; 25(4): 1423-1431, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794691

RESUMEN

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Asunto(s)
Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Estudios de Casos y Controles , Muerte Súbita Cardíaca/etiología , Estudios Retrospectivos , Resultado del Tratamiento
7.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37350404

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Desfibriladores Implantables , Humanos , Administración Intravenosa , Antibacterianos , Hospitalización , Resultado del Tratamiento
8.
Europace ; 24(2): 234-244, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34392336

RESUMEN

AIMS: We developed and validated an algorithm for prediction of heart failure (HF) hospitalizations using remote monitoring (RM) data transmitted by implanted defibrillators. METHODS AND RESULTS: The SELENE HF study enrolled 918 patients (median age 69 years, 81% men, median ejection fraction 30%) with cardiac resynchronization therapy (44%), dual-chamber (38%), or single-chamber defibrillators with atrial diagnostics (18%). To develop a predictive algorithm, temporal trends of diurnal and nocturnal heart rates, ventricular extrasystoles, atrial tachyarrhythmia burden, heart rate variability, physical activity, and thoracic impedance obtained by daily automatic RM were combined with a baseline risk-stratifier (Seattle HF Model) into one index. The primary endpoint was the first post-implant adjudicated HF hospitalization. After a median follow-up of 22.5 months since enrolment, patients were randomly allocated to the algorithm derivation group (n = 457; 31 endpoints) or algorithm validation group (n = 461; 29 endpoints). In the derivation group, the index showed a C-statistics of 0.89 [95% confidence interval (CI): 0.83-0.95] with 2.73 odds ratio (CI 1.98-3.78) for first HF hospitalization per unitary increase of index value (P < 0.001). In the validation group, sensitivity of predicting primary endpoint was 65.5% (CI 45.7-82.1%), median alerting time 42 days (interquartile range 21-89), and false (or unexplained) alert rate 0.69 (CI 0.64-0.74) [or 0.63 (CI 0.58-0.68)] per patient-year. Without the baseline risk-stratifier, the sensitivity remained 65.5% and the false/unexplained alert rates increased by ≈10% to 0.76/0.71 per patient-year. CONCLUSION: With the developed algorithm, two-thirds of first post-implant HF hospitalizations could be predicted timely with only 0.7 false alerts per patient-year.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Masculino , Volumen Sistólico
9.
Pacing Clin Electrophysiol ; 45(5): 612-618, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35383979

RESUMEN

BACKGROUND: Although radiofrequency (RF) catheter ablation of cavo-tricuspid isthmus (CTI) is an established treatment for typical right atrial flutter (RAFL), it remains to be established whether local tissue impedance (LI) is able to predict effective CTI ablation and what LI drop values during ablation should be used to judge a lesion as effective. We aimed to investigate the ability of LI to predict ablation efficacy in patients with RAFL. METHODS: RF delivery was guided by the DirectSense™ algorithm. Successful single RF application was defined according to a defragmentation of atrial potentials (DAP), reduction of voltage (RedV) by at least 80% or changes on unipolar electrogram (UPC). The ablation endpoint was the creation of bidirectional conduction block (BDB) across the isthmus. RESULTS: 392 point-by-point RF applications were analyzed in 48 consecutive RAFL patients. The mean baseline LI was 105.4 ± 12Ω prior to ablation and 92.0 ± 11Ω after ablation (p < 0.0001). According to validation criteria, absolute drops in impedance were larger at successful ablation sites than at ineffective ablation sites (DAP: 17.8 ± 6Ω vs. 8.7 ± 4Ω; RedV: 17.2 ± 6Ω vs. 7.8 ± 5Ω; UPC: 19.6 ± 6Ω vs. 10.1 ± 5Ω, all p < 0.0001). LI drop values significantly increased according to the number of criteria satisfied (ranging from 7.5Ω to 19.9). BDB was obtained in all cases. No procedure-related adverse events were reported. CONCLUSIONS: A LI-guided approach to CTI ablation was safe and effective in treating RAFL. The magnitude of LI drop was associated with effective lesion formation and BDB and could be used as a marker of ablation efficacy. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Ablación por Catéter/efectos adversos , Impedancia Eléctrica , Bloqueo Cardíaco/etiología , Humanos , Resultado del Tratamiento
10.
Europace ; 22(2): 299-305, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31722381

RESUMEN

AIMS: A prolonged PR interval is known to be associated with increased mortality and a higher risk of developing atrial fibrillation (AF). We tested the hypothesis that cardiac resynchronization therapy (CRT) is superior to conventional dual-chamber pacing with algorithms for right ventricular pacing avoidance (DDD-VPA) in preserving systolic and diastolic function and in preventing new-onset AF in patients with normal systolic function, indication for pacing and prolonged atrioventricular conduction (PR interval ≥220 ms). METHODS AND RESULTS: We randomly assigned 82 patients with ejection fraction >35%, indication for pacing and PR interval ≥220 ms to CRT or to DDD-VPA. On 12-month follow-up examination, the study and control arms did not differ in terms of left ventricular end-systolic volume (44 ± 17 mL vs. 47 ± 16 mL, P = 0.511) or ejection fraction (55 ± 6% vs. 57 ± 8%, P = 0.291). The E to A mitral wave amplitude ratio was higher in the CRT arm (1.3 ± 1.3 vs. 0.8 ± 0.4, P = 0.046) and the E wave deceleration time was longer (262 ± 83 ms vs. 205 ± 51 ms, P = 0.027). Left atrial volume was smaller in the CRT arm (64 ± 17 mL vs. 84 ± 25 mL, P = 0.035). Moreover, the functional class was lower in CRT patients (1.4 ± 0.6 vs. 1.8 ± 0.5, P = 0.010). During follow-up, CRT was associated with a lower risk of new-onset AF [hazard ratio = 0.37 (0.13-0.98), P = 0.046]. CONCLUSION: Cardiac resynchronization therapy proved superior to DDD-VPA in terms of better diastolic function, less left atrial enlargement and lower risk of new-onset AF, at 12 months. These data need to be confirmed in a larger trial with longer follow-up. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/ Identifier: NCT02150538.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Atrios Cardíacos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Proyectos Piloto , Resultado del Tratamiento
11.
Europace ; 21(4): 636-644, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-30649270

RESUMEN

AIMS: Per standard of care, dual-chamber pacemakers are programmed in DDDR mode with fixed atrioventricular (AV) delay or with long AV delay to minimize ventricular pacing. We aimed to evaluate whether the PR interval may be a specific criterion of choice between standard DDDR, to preserve AV synchrony in long PR patients, and managed ventricular pacing (MVP), to avoid ventricular desynchronization imposed by right ventricle apical pacing, in short PR patients. METHODS AND RESULTS: In the MINERVA trial, 1166 patients were randomized to Control DDDR, MVP, or atrial anti-tachycardia pacing plus MVP (DDDRP + MVP). We evaluated the interaction of PR interval with pacing mode by comparing the risk of atrial fibrillation (AF) longer than 7 consecutive days as a function of PR interval. Out of 906 patients with available data, the median PR interval was 180 ms. The PR interval was found to significantly (P = 0.012) interact with pacing mode for AF incidence: the risk of AF > 7 days was lower [hazard ratio (HR) 0.58, 95% confidence interval (95% CI) 0.34-0.99; P = 0.047] in patients with short PR (shorter than median PR) if programmed in MVP mode compared with DDDR mode and it was lower (HR 0.65, 95% CI 0.43-0.99; P = 0.049) in patients with long PR (equal to or longer than median PR) if programmed in DDDR mode compared with MVP. CONCLUSION: Our data show that PR interval may be used as a selection criterion to identify the optimal physiological pacing mode. Persistent AF incidence was lower in short PR patients treated by right ventricular pacing minimization and in long PR patients treated by standard dual-chamber pacing.


Asunto(s)
Algoritmos , Fibrilación Atrial/epidemiología , Bloqueo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Bloqueo Interauricular/fisiopatología , Síndrome del Seno Enfermo/terapia , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Fibrilación Atrial/fisiopatología , Electrocardiografía , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Marcapaso Artificial , Pronóstico , Modelos de Riesgos Proporcionales , Síndrome del Seno Enfermo/fisiopatología
12.
Monaldi Arch Chest Dis ; 88(2): 949, 2018 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-29877661

RESUMEN

Atrial fibrillation (AF) is a relevant cardiovascular condition that is more prevalent in the elderly patients aged over 65 years. AF, with abnormal rate and rhythm can cause symptoms directly or indirectly by exacerbating other frequently coexisting cardiac conditions such as valvular heart disease, hypertension, ischemic cardiomyopathy, dilated cardiomyopathy, and hypertrophic cardiomyopathy. Evidence suggests that aging-related cardiovascular changes predispose to the elderly to AF. Current therapeutic options such as antiarrhythmic drugs have not been extensively evaluated in the elderly population. Emerging pharmacological and non-pharmacological treatment options for the management of AF, such as dronedarone or catheter ablation, are of particular interest in the elderly. The present paper reviews the pathophysiology, diagnosis, and the management of AF in the elderly patient.

13.
Europace ; 19(11): 1826-1832, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28011803

RESUMEN

AIMS: A recommendation for a subcutaneous-implantable cardioverter-defibrillator (S-ICD) has been added to recent European Society of Cardiology Guidelines. However, the S-ICD is not ideally suitable for patients who need pacing. The aim of this survey was to analyse the current practice of ICD implantation and to evaluate the actual suitability of S-ICD. METHODS AND RESULTS: The survey 'S-ICD Why Not?' was an independent initiative taken by the Italian Heart Rhythm Society (AIAC). Clinical characteristics, selection criteria, and factors guiding the choice of ICD type were collected in consecutive patients who underwent ICD implantation in 33 Italian centres from September to December 2015. A cardiac resynchronization therapy (CRT) device was implanted in 39% (369 of 947) of patients undergoing de novo ICD implantation. An S-ICD was implanted in 12% of patients with no CRT indication (62 of 510 with available data). S-ICD patients were younger than patients who received transvenous ICD, more often had channelopathies, and more frequently received their device for secondary prevention of sudden death. More frequently, the clinical reason for preferring a transvenous ICD over an S-ICD was the need for pacing (45%) or for antitachycardia pacing (36%). Nonetheless, only 7% of patients fulfilled conditions for recommending permanent pacing, and 4% of patients had a history of monomorphic ventricular tachycardia that might have been treatable with antitachycardia pacing. CONCLUSION: The vast majority of patients needing ICD therapy are suitable candidates for S-ICD implantation. Nevertheless, it currently seems to be preferentially adopted for secondary prevention of sudden death in young patients with channelopathies.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Canalopatías , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Secundaria/instrumentación , Adulto , Anciano , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Terapia de Resincronización Cardíaca/efectos adversos , Toma de Decisiones Clínicas , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Femenino , Encuestas de Atención de la Salud , Humanos , Italia , Masculino , Persona de Mediana Edad , Selección de Paciente , Factores de Riesgo , Resultado del Tratamiento
15.
Eur Heart J ; 35(35): 2352-62, 2014 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-24771721

RESUMEN

AIMS: Atrial fibrillation (AF) is a common comorbidity in bradycardia patients. Advanced pacemakers feature atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), which minimizes unnecessary right ventricular pacing. We evaluated whether DDDRP and MVP might reduce mortality, morbidity, or progression to permanent AF when compared with standard dual-chamber pacing (Control DDDR). METHODS AND RESULTS: In a randomized, parallel, single-blind, multi-centre trial we enrolled 1300 patients with bradycardia and previous atrial tachyarrhythmias, in whom a DDDRP pacemaker had recently been implanted. History of permanent AF and third-degree atrioventricular block were exclusion criteria. After a 1-month run-in period, 1166 eligible patients, aged 74 ± 9 years, 50% females, were randomized to Control DDDR, DDDRP + MVP, or MVP. Analysis was intention-to-treat. The primary outcome, i.e. the 2-year incidence of a combined endpoint composed of death, cardiovascular hospitalizations, or permanent AF, occurred in 102/385 (26.5%) Control DDDR patients, in 76/383 (19.8%) DDDRP + MVP patients [hazard ratio (HR) = 0.74, 95% confidence interval 0.55-0.99, P = 0.04 vs. Control DDDR] and in 85/398 (21.4%) MVP patients (HR = 0.89, 95% confidence interval 0.77-1.03, P = 0.125 vs. Control DDDR). When compared with Control DDDR, DDDRP + MVP reduced the risk for AF longer than 1 day (HR = 0.66, 95% CI 0.52-0.85, P < 0.001), AF longer than 7 days (HR = 0.52, 95% CI 0.36-0.73, P < 0.001), and permanent AF (HR = 0.39, 95% CI 0.21-0.75, P = 0.004). CONCLUSION: In patients with bradycardia and atrial tachyarrhythmias, DDDRP + MVP is superior to standard dual-chamber pacing. The primary endpoint was significantly lowered through the reduction of the progression of atrial tachyarrhythmias to permanent AF. CLINICALTRIALSGOV IDENTIFIER: NCT00262119.


Asunto(s)
Fibrilación Atrial/terapia , Bradicardia/terapia , Estimulación Cardíaca Artificial/métodos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Bradicardia/complicaciones , Bradicardia/mortalidad , Estimulación Cardíaca Artificial/efectos adversos , Costo de Enfermedad , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Estimación de Kaplan-Meier , Masculino , Calidad de Vida , Factores de Riesgo , Método Simple Ciego , Resultado del Tratamiento
16.
Int J Cardiol ; 411: 132276, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38880419

RESUMEN

BACKGROUND: Frailty and comorbidity influence the therapeutic approach in everyday clinical practice. The DOACs genericization opens a reflection on their differences from a pharmacological and bioavailability point of view, particularly in elderly frail patients. The aim of this project was to create a national Delphi consensus on the topic of the use of DOACs for atrial fibrillation (AF) in such patients, in light of the genericization of the class. METHODS AND RESULTS: The consensus dealt with 3 main topics: a) efficacy and safety of DOACs in elderly and/or frail patients; b) therapeutic choice in specific frailty scenarios; c) DOACs genericization. 56 cardiologists, two internists and two neurologists from Italy expressed their level of agreement on each statement by using a 5-point Likert scale (1: strongly disagree, 2: disagree, 3: uncertain, 4: agree, 5: strongly agree). A positive consensus was reached if the percentage of agreement (vote 1-2, positive consensus) or disagreement (votes 4-5, negative consensus) was >66%; otherwise, no consensus was reached. Results are displayed accordingly. CONCLUSIONS: After 10 years of everyday clinical management of DOACs for AF, specific elements differentiating a molecule from another, either for efficacy or for safety, are consolidated. However, some uncertainties still exist in particular contexts, such as chronic kidney disease or cancer patients. Clinicians have an unsure attitude towards generic drugs, because clinical practice is lacking as well as a proper knowledge of the topic. Albeit being an alternative, the choice of the generic drug must remain the responsibility of the clinician.


Asunto(s)
Fibrilación Atrial , Técnica Delphi , Medicamentos Genéricos , Anciano Frágil , Humanos , Anciano , Fibrilación Atrial/tratamiento farmacológico , Medicamentos Genéricos/uso terapéutico , Inhibidores del Factor Xa/uso terapéutico , Inhibidores del Factor Xa/administración & dosificación , Femenino , Masculino , Anciano de 80 o más Años , Consenso , Italia/epidemiología , Accidente Cerebrovascular
17.
J Cardiovasc Electrophysiol ; 24(2): 173-81, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23130781

RESUMEN

INTRODUCTION: The characteristics and outcomes of patients who undergo cardiac resynchronization therapy (CRT) device implantation in current clinical practice may differ from those of reference trial populations. Study objectives were to assess 2-year outcomes in a population implanted with a CRT plus defibrillator device in accordance with the standard of care and to evaluate any independent association between clinical variables and outcome. METHODS AND RESULTS: A total of 406 patients enrolled at 35 centers in Italy were followed up prospectively for 2 years. All patient management decisions were left to the treating physician's discretion, in accordance with clinical practice. ACTION-HF patients had a better baseline clinical status than patients enrolled in the COMPANION study: shorter HF history (1 vs 3.5 years, P < 0.01), less advanced NYHA functional class (III-IV: 73% vs 100%, P < 0.01), higher LVEF (26% vs 21%, P < 0.01), higher SBP (122 vs 112 mmHg, P < 0.01), and less diabetes (27% vs 41%, P < 0.01). This status was reflected in lower mortality (11.5% vs 26%) and a lower incidence of appropriate ICD shocks (12.1% vs 19.3%). AF history was an independent predictor of the combination of all-cause mortality and cardiac-cause hospitalization (HR: 3.31; P < 0.001). Recurrent or new atrial arrhythmias were independently associated with the development of ventricular arrhythmias (HR: 3.4; P < 0.001). CONCLUSIONS: This population appears clinically less compromised and had a lower incidence of adverse clinical outcomes than those of reference trials. However, we recorded a substantial burden of atrial arrhythmias, which was independently associated with a higher incidence of ventricular arrhythmias.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Terapia de Resincronización Cardíaca/mortalidad , Hospitalización/estadística & datos numéricos , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/prevención & control , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/prevención & control , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Factores de Riesgo , Análisis de Supervivencia , Tasa de Supervivencia , Resultado del Tratamiento
18.
J Clin Med ; 12(17)2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37685593

RESUMEN

(200 w) Introduction. Remote monitoring (RM) of cardiac implantable electronic device (CIED) diagnostics helps to identify patients potentially at risk of worsening heart failure (HF). Additionally, knowledge of patient HF-related symptoms is crucial for decision making. Patient smartphone applications may represent an ideal option to remotely collect this information. PURPOSE: To assess real-world HF patient access, acceptance, and adherence to use of an HF-dedicated smartphone application (HF app). METHODS: In this study, 10 Italian hospitals administered a survey on smartphone/app use to HF patients with CIED. The subgroup who accepted it downloaded the HF app. Mean 1-year adherence of the HF app use was evaluated. RESULTS: A total of 495 patients (67 ± 13 years, 79% males, 26% NYHA III-IV) completed the survey, of which 84% had access to smartphones and 85% were willing to use the HF app. In total, 311/495 (63%) downloaded the HF app. Patients who downloaded the HF app were younger and had higher school qualification. Patients who were ≥60 years old had higher mean 1-year adherence (54.1%) than their younger counterparts (42.7%; p < 0.001). Hospitals with RM-dedicated staff had higher mean 1-year patient adherence (64.0% vs. 33.5%; p < 0.001). Adherence to HF app decreased from 63.3% (weeks_1-13) to 42.2% (weeks_40-52, p < 0.001). CONCLUSIONS: High access and acceptance of smartphones/apps by HF patients with CIED allow HF app use for RM of patient signs/symptoms. Younger patients with higher school qualifications are more likely to accept HF app; however, older patients have higher long-term adherence.

19.
JMIR Cardio ; 6(1): e30661, 2022 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-35103602

RESUMEN

BACKGROUND: The COVID-19 pandemic forced several European governments to impose severe lockdown measures. The reduction of physical activity during the lockdown could have been deleterious. OBJECTIVE: The aim of this observational, retrospective study was to investigate the effect of the lockdown strategy on the physical activity burden and subsequent reassessment in a group of patients with heart failure who were followed by means of remote monitoring. METHODS: We analyzed remote monitoring transmissions during the 3-month period immediately preceding the lockdown, 69 days of lockdown, and 3-month period after the first lockdown in a cohort of patients with heart failure from a general hospital in Lombardy, Italy. We compared variation of daily physical activity measured by cardiac implantable electrical devices with clinical variables collected in a hospital database. RESULTS: We enrolled 41 patients with heart failure that sent 176 transmissions. Physical activity decreased during the lockdown period (mean 3.4, SD 1.9 vs mean 2.9, SD 1.8 hours/day; P<.001) but no significant difference was found when comparing the period preceding and following the lockdown (-0.0007 hours/day; P=.99). We found a significant correlation between physical activity reduction during and after the lockdown (R2=0.45, P<.001). The only significant predictor of exercise variation in the postlockdown period was the lockdown to prelockdown physical activity ratio. CONCLUSIONS: An excessive reduction of exercise in patients with heart failure decreased the tolerance to exercise, especially in patients with more comorbidities. Remote monitoring demonstrated exercise reduction, suggesting its potential utility to encourage patients to maintain their usual physical activity levels.

20.
Clin Res Cardiol ; 111(11): 1189-1197, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35305126

RESUMEN

Sudden cardiac death (SCD) is the most frequent cause of cardiovascular death in industrialized nations. Patients with cardiomyopathy are at increased risk for SCD and may benefit from an implantable cardioverter-defibrillator (ICD). The risk of SCD is highest in the first months after myocardial infarction or first diagnosis of severe non-ischemic cardiomyopathy. On the other hand, left ventricular function may improve in a subset of patients to such an extent that an ICD might no longer be needed. To offer protection from a transient risk of SCD, the wearable cardioverter-defibrillator (WCD) is available. Results of the first randomized clinical trial investigating the role of the WCD after myocardial infarction were recently published. This review is intended to provide insight into data from the VEST trial, and to put these into perspective with studies and clinical experience. As a non-invasive, temporary therapy, the WCD may offer advantages over early ICD implantation. However, recent data demonstrate that patient compliance and education play a crucial role in this new concept of preventing SCD.


Asunto(s)
Cardiomiopatías , Desfibriladores Implantables , Infarto del Miocardio , Dispositivos Electrónicos Vestibles , Humanos , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica/efectos adversos , Desfibriladores Implantables/efectos adversos , Cardiomiopatías/complicaciones , Infarto del Miocardio/complicaciones , Dispositivos Electrónicos Vestibles/efectos adversos , Desfibriladores , Ensayos Clínicos Controlados Aleatorios como Asunto