Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 387(10): 882-893, 2022 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-36069870

RESUMEN

BACKGROUND: Whether improved glucose control with hybrid closed-loop therapy can preserve C-peptide secretion as compared with standard insulin therapy in persons with new-onset type 1 diabetes is unclear. METHODS: In a multicenter, open-label, parallel-group, randomized trial, we assigned youths 10.0 to 16.9 years of age within 21 days after a diagnosis of type 1 diabetes to receive hybrid closed-loop therapy or standard insulin therapy (control) for 24 months. The primary end point was the area under the curve (AUC) for the plasma C-peptide level (after a mixed-meal tolerance test) at 12 months after diagnosis. The analysis was performed on an intention-to-treat basis. RESULTS: A total of 97 participants (mean [±SD] age, 12±2 years) underwent randomization: 51 were assigned to receive closed-loop therapy and 46 to receive control therapy. The AUC for the C-peptide level at 12 months (primary end point) did not differ significantly between the two groups (geometric mean, 0.35 pmol per milliliter [interquartile range, 0.16 to 0.49] with closed-loop therapy and 0.46 pmol per milliliter [interquartile range, 0.22 to 0.69] with control therapy; mean adjusted difference, -0.06 pmol per milliliter [95% confidence interval {CI}, -0.14 to 0.03]). There was not a substantial between-group difference in the AUC for the C-peptide level at 24 months (geometric mean, 0.18 pmol per milliliter [interquartile range, 0.06 to 0.22] with closed-loop therapy and 0.24 pmol per milliliter [interquartile range, 0.05 to 0.30] with control therapy; mean adjusted difference, -0.04 pmol per milliliter [95% CI, -0.14 to 0.06]). The arithmetic mean glycated hemoglobin level was lower in the closed-loop group than in the control group by 4 mmol per mole (0.4 percentage points; 95% CI, 0 to 8 mmol per mole [0.0 to 0.7 percentage points]) at 12 months and by 11 mmol per mole (1.0 percentage points; 95% CI, 7 to 15 mmol per mole [0.5 to 1.5 percentage points]) at 24 months. Five cases of severe hypoglycemia occurred in the closed-loop group (in 3 participants), and one occurred in the control group; one case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In youths with new-onset type 1 diabetes, intensive glucose control for 24 months did not appear to prevent the decline in residual C-peptide secretion. (Funded by the National Institute for Health and Care Research and others; CLOuD ClinicalTrials.gov number, NCT02871089.).


Asunto(s)
Péptido C , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Insulina , Adolescente , Glucemia/análisis , Péptido C/metabolismo , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/metabolismo , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina
2.
N Engl J Med ; 386(3): 209-219, 2022 01 20.
Artículo en Inglés | MEDLINE | ID: mdl-35045227

RESUMEN

BACKGROUND: The possible advantage of hybrid closed-loop therapy (i.e., artificial pancreas) over sensor-augmented pump therapy in very young children with type 1 diabetes is unclear. METHODS: In this multicenter, randomized, crossover trial, we recruited children 1 to 7 years of age with type 1 diabetes who were receiving insulin-pump therapy at seven centers across Austria, Germany, Luxembourg, and the United Kingdom. Participants received treatment in two 16-week periods, in random order, in which the closed-loop system was compared with sensor-augmented pump therapy (control). The primary end point was the between-treatment difference in the percentage of time that the sensor glucose measurement was in the target range (70 to 180 mg per deciliter) during each 16-week period. The analysis was conducted according to the intention-to-treat principle. Key secondary end points included the percentage of time spent in a hyperglycemic state (glucose level, >180 mg per deciliter), the glycated hemoglobin level, the mean sensor glucose level, and the percentage of time spent in a hypoglycemic state (glucose level, <70 mg per deciliter). Safety was assessed. RESULTS: A total of 74 participants underwent randomization. The mean (±SD) age of the participants was 5.6±1.6 years, and the baseline glycated hemoglobin level was 7.3±0.7%. The percentage of time with the glucose level in the target range was 8.7 percentage points (95% confidence interval [CI], 7.4 to 9.9) higher during the closed-loop period than during the control period (P<0.001). The mean adjusted difference (closed-loop minus control) in the percentage of time spent in a hyperglycemic state was -8.5 percentage points (95% CI, -9.9 to -7.1), the difference in the glycated hemoglobin level was -0.4 percentage points (95% CI, -0.5 to -0.3), and the difference in the mean sensor glucose level was -12.3 mg per deciliter (95% CI, -14.8 to -9.8) (P<0.001 for all comparisons). The time spent in a hypoglycemic state was similar with the two treatments (P = 0.74). The median time spent in the closed-loop mode was 95% (interquartile range, 92 to 97) over the 16-week closed-loop period. One serious adverse event of severe hypoglycemia occurred during the closed-loop period. One serious adverse event that was deemed to be unrelated to treatment occurred. CONCLUSIONS: A hybrid closed-loop system significantly improved glycemic control in very young children with type 1 diabetes, without increasing the time spent in hypoglycemia. (Funded by the European Commission and others; ClinicalTrials.gov number, NCT03784027.).


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Control Glucémico/instrumentación , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Algoritmos , Glucemia/análisis , Niño , Preescolar , Estudios Cruzados , Diseño de Equipo , Femenino , Hemoglobina Glucada/análisis , Control Glucémico/métodos , Humanos , Hiperglucemia/diagnóstico , Lactante , Masculino
3.
Diabetologia ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38740602

RESUMEN

The role of automated insulin delivery systems in diabetes is expanding. Hybrid closed-loop systems are being used in routine clinical practice for treating people with type 1 diabetes. Encouragingly, real-world data reflects the performance and usability observed in clinical trials. We review the commercially available hybrid closed-loop systems, their distinctive features and the associated real-world data. We also consider emerging indications for closed-loop systems, including the treatment of type 2 diabetes where variability of day-to-day insulin requirements is high, and other challenging applications for this technology. We discuss issues around access and implementation of closed-loop technology, and consider the limitations of present closed-loop systems, as well as innovative approaches that are being evaluated to improve their performance.

4.
Diabet Med ; 40(6): e15092, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36947090

RESUMEN

AIMS: Fully closed-loop insulin delivery has been shown in clinical trials to be safe and improve glucose control compared with standard insulin therapy in the inpatient setting. We investigated the feasibility of implementing the approved CamAPS HX fully closed-loop system in a hospital setting. METHODS: This implementation project was conducted in a large teaching hospital in Cambridge, UK. Healthcare professional training was multimodal including face-to-face workshops, online learning modules and supported by standard operating procedures. Set-up and maintenance of closed-loop devices were undertaken by the inpatient diabetes team. Selection of suitable patients was multidisciplinary and prioritised those with more challenging diabetes management. Demographic and clinical data were collected from electronic health records and diabetes data management platforms. RESULTS: In the 12 months since the closed-loop system was implemented, 32 inpatients (mean ± SD age 61 ± 16 years, 8 females, 24 males) used closed-loop insulin delivery during their admission, across medical and surgical wards in the hospital with a total of 555 days of closed-loop glucose control (median [IQR]: 14 [6, 22] days per inpatient). The time spent in target glucose range 3.9-10.0 mmol/L was 53.3 ± 18.3%. Mean glucose was 10.7 ± 1.9 mmol/L with 46.0 ± 18.2% of time spent with glucose >10.0 mmol/L. Time spent with sensor glucose below 3.9 mmol/L was low (median [IQR]: 0.38 [0.00, 0.85]). There were no episodes of severe hypoglycaemia or diabetic ketoacidosis during closed-loop use. CONCLUSIONS: We have demonstrated that the fully closed-loop system can be safely and effectively implemented by a diabetes outreach team in complex medical and surgical inpatients with challenging glycaemic control.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Insulina/uso terapéutico , Glucemia , Hipoglucemiantes/uso terapéutico , Pacientes Internos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Resultado del Tratamiento , Sistemas de Infusión de Insulina , Estudios Cruzados
5.
Diabet Med ; 39(7): e14828, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35274356

RESUMEN

AIMS: To explore parents' experiences of using remote monitoring technology when caring for a very young child with type 1 diabetes during a clinical trial. METHODS: Interviews were conducted with parents of 30 children (aged 1-7 years) participating in a trial (the KidsAP02 study) comparing hybrid closed-loop insulin delivery with sensor-augmented pump therapy. In both arms, parents had access to remote monitoring technology. Data analysis focused on identification of descriptive themes. RESULTS: Remote monitoring technology gave parents improved access to data which helped them pre-empt and manage glucose excursions. Parents observed how, when children were in their own care, they could be more absent while present, as their attention could shift to non-diabetes-related activities. Conversely, when children were others' care, remote monitoring enabled parents to be present while absent, by facilitating oversight and collaboration with caregivers. Parents described how remote monitoring made them feel more confident allowing others to care for their children. Parents' confidence increased when using a hybrid closed-loop system, as less work was required to keep glucose in range. Benefits to children were also highlighted, including being able to play and sleep uninterrupted and attend parties and sleepovers without their parents. While most parents welcomed the increased sense of control remote monitoring offered, some noted downsides, such as lack of respite from caregiving responsibilities. CONCLUSIONS: Remote monitoring can offer manifold benefits to both parents and very young children with type 1 diabetes. Some parents, however, may profit from opportunities to take 'time out'.


Asunto(s)
Diabetes Mellitus Tipo 1 , Padres , Tecnología de Sensores Remotos , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Preescolar , Ensayos Clínicos como Asunto , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Lactante , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Padres/psicología
6.
Diabetes Obes Metab ; 24(12): 2309-2318, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35837984

RESUMEN

AIM: To examine changes in the lived experience of type 1 diabetes after use of hybrid closed loop (CL), including the CamAPS FX CL system. MATERIALS AND METHODS: The primary study was conducted as an open-label, single-period, randomized, parallel design contrasting CL versus insulin pump (with or without continuous glucose monitoring). Participants were asked to complete patient-reported outcomes before starting CL and 3 and 6 months later. Surveys assessed diabetes distress, hypoglycaemia concerns and quality of life. Qualitative focus group data were collected at the completion of the study. RESULTS: In this sample of 98 youth (age range 6-18, mean age 12.7 ± 2.8 years) and their parents, CL use was not associated with psychosocial benefits overall. However, the subgroup (n = 12) using the CamAPS FX system showed modest improvements in quality of life and parent distress, reinforced by both survey (p < .05) and focus group responses. There were no negative effects of CL use reported by study participants. CONCLUSIONS: Closed loop use via the CamAPS FX system was associated with modest improvements in aspects of the lived experience of managing type 1 diabetes in youth and their families. Further refinements of the system may optimize the user experience.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Automonitorización de la Glucosa Sanguínea , Insulina/uso terapéutico , Calidad de Vida , Hipoglucemiantes/uso terapéutico , Glucemia , Resultado del Tratamiento , Sistemas de Infusión de Insulina , Padres/psicología
7.
Pediatr Diabetes ; 23(6): 799-808, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35561092

RESUMEN

OBJECTIVES: We explored parents' views about healthcare professionals having remote access to their young child's insulin and glucose data during a clinical trial to inform use of data sharing in routine pediatric diabetes care. RESEARCH DESIGN AND METHODS: Interviews with 33 parents of 30 children (aged 1-7 years) with type 1 diabetes participating in a randomized trial (KidsAP02) comparing hybrid closed-loop system use with sensor-augmented pump therapy. Data were analyzed using a qualitative descriptive approach. RESULTS: Parents reported multiple benefits to healthcare professionals being able to remotely access their child's glucose and insulin data during the trial, despite some initial concerns regarding the insights offered into everyday family life. Key benefits included: less work uploading/sharing data; improved consultations; and, better clinical input and support from healthcare professionals between consultations. Parents noted how healthcare professionals' real-time data access facilitated remote delivery of consultations during the COVID-19 pandemic, and how these were more suitable for young children than face-to-face appointments. Parents endorsed use of real-time data sharing in routine clinical care, subject to caveats regarding data access, security, and privacy. They also proposed that, if data sharing were used, consultations for closed-loop system users in routine clinical care could be replaced with needs-driven, ad-hoc contact. CONCLUSIONS: Real-time data sharing can offer clinical, logistical, and quality-of-life benefits and enhance opportunities for remote consultations, which may be more appropriate for young children. Wider rollout would require consideration of ethical and cybersecurity issues and, given the heightened intrusion on families' privacy, a non-judgmental, collaborative approach by healthcare professionals.


Asunto(s)
Diabetes Mellitus Tipo 1 , Padres , COVID-19 , Niño , Preescolar , Atención a la Salud , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa , Humanos , Lactante , Insulina/uso terapéutico , Pandemias , Padres/psicología , Investigación Cualitativa , Ensayos Clínicos Controlados Aleatorios como Asunto
8.
Diabetologia ; 64(5): 1007-1015, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33550442

RESUMEN

Advances in diabetes technologies have enabled the development of automated closed-loop insulin delivery systems. Several hybrid closed-loop systems have been commercialised, reflecting rapid transition of this evolving technology from research into clinical practice, where it is gradually transforming the management of type 1 diabetes in children and adults. In this review we consider the supporting evidence in terms of glucose control and quality of life for presently available closed-loop systems and those in development, including dual-hormone closed-loop systems. We also comment on alternative 'do-it-yourself' closed-loop systems. We remark on issues associated with clinical adoption of these approaches, including training provision, and consider limitations of presently available closed-loop systems and areas for future enhancements to further improve outcomes and reduce the burden of diabetes management.


Asunto(s)
Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Adulto , Glucemia/análisis , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/tendencias , Niño , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Insulina/efectos adversos , Invenciones/tendencias , Páncreas Artificial/provisión & distribución , Páncreas Artificial/tendencias
9.
Diabetes Obes Metab ; 23(8): 1978-1982, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33822461

RESUMEN

The aim of this study was to characterize the variability of exogenous insulin requirements during fully closed-loop insulin delivery in hospitalized patients with type 2 diabetes or new-onset hyperglycaemia, and to determine patient-related characteristics associated with higher variability of insulin requirements. We retrospectively analysed data from two fully closed-loop inpatient studies involving adults with type 2 diabetes or new-onset hyperglycaemia requiring insulin therapy. The coefficient of variation quantified day-to-day variability of exogenous insulin requirements during up to 15 days using fully automated closed-loop insulin delivery. Data from 535 days in 67 participants were analysed. The coefficient of variation of day-to-day exogenous insulin requirements was 30% ± 16%, and was higher between nights than between any daytime period (56% ± 29% overnight [11:00 pm to 4:59 am] compared with 41% ± 21% in the morning [5:00 am to 10:59 am], 39% ± 15% in the afternoon [11:00 am to 4:59 pm] and 45% ± 19% during the evening [5:00 pm to 10:59 pm]; all P < 0.01). There is high day-to-day variability of exogenous insulin requirements in inpatients, particularly overnight, and diabetes management approaches should account for this variability.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Pacientes Internos , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Estudios Retrospectivos
10.
Diabetes Obes Metab ; 23(6): 1389-1396, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33606901

RESUMEN

AIM: To evaluate the use of hybrid closed-loop glucose control with faster-acting insulin aspart (Fiasp) in adults with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: In a double-blind, multinational, randomized, crossover study, 25 adults with T1D using insulin pump therapy (mean ± SD, age 38 ± 9 years, HbA1c 7.4% ± 0.8% [57 ± 8 mmol/mol]) underwent two 8-week periods of unrestricted living comparing hybrid closed-loop with Fiasp and hybrid closed-loop with standard insulin aspart in random order. During both interventions the CamAPS FX closed-loop system incorporating the Cambridge model predictive control algorithm was used. RESULTS: In an intention-to-treat analysis, the proportion of time sensor glucose was in the target range (3.9-10.0 mmol/L; primary endpoint) was not different between interventions (75% ± 8% vs. 75% ± 8% for hybrid closed-loop with Fiasp vs. hybrid closed-loop with standard insulin aspart; mean-adjusted difference -0.6% [95% CI -1.8% to 0.7%]; p < .001 for non-inferiority [non-inferiority margin 5%]). The proportion of time with sensor glucose less than 3.9 mmol/L (median [IQR] 2.4% [1.2%-3.2%] vs. 2.9% [1.7%-4.0%]; p = .01) and less than 3.0 mmol/L (median [IQR] 0.4% [0.2%-0.7%] vs. 0.7% [0.2%-0.9%]; p = .03) was reduced with Fiasp versus standard insulin aspart. There was no difference in mean glucose (8.1 ± 0.8 vs. 8.0 ± 0.8 mmol/L; p = .13) or glucose variability (SD of sensor glucose 2.9 ± 0.5 vs. 2.9 ± 0.5 mmol/L; p = .90). Total daily insulin requirements did not differ (49 ± 15 vs. 49 ± 15 units/day; p = .45). No severe hypoglycaemia or ketoacidosis occurred. CONCLUSIONS: The use of Fiasp in the CamAPS FX closed-loop system may reduce hypoglycaemia without compromising glucose control compared with standard insulin aspart in adults with T1D.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina Aspart , Adulto , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Insulina Aspart/uso terapéutico , Sistemas de Infusión de Insulina , Persona de Mediana Edad
11.
Curr Opin Organ Transplant ; 25(4): 336-342, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32618719

RESUMEN

PURPOSE OF REVIEW: Advances in diabetes technologies have enabled the development of artificial pancreas (closed-loop) systems for people with diabetes. We review the key studies which have led to the adoption of the artificial pancreas in clinical practice and consider ongoing challenges and areas for future enhancements. RECENT FINDINGS: Studies have demonstrated safety and efficacy of closed-loop insulin delivery systems in free-living settings over periods of up to 6 months for children and adults with type 1 diabetes. Since 2017, four hybrid closed-loop systems have been approved by regulatory bodies worldwide, but these systems are not entirely automated, requiring user interaction to deliver mealtime insulin boluses. Improving usability of these devices in the real-world setting is an important challenge. SUMMARY: The artificial pancreas has become the gold standard for the treatment of type 1 diabetes. First-generation systems are increasingly being adopted in clinical practice, however further work is required, developing advanced systems and faster acting insulin analogues to allow complete automation and further reduce the burden of type 1 diabetes.


Asunto(s)
Diabetes Mellitus Tipo 1/terapia , Páncreas Artificial , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes , Insulina/administración & dosificación , Sistemas de Infusión de Insulina
12.
Pediatr Diabetes ; 20(6): 794-799, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31140654

RESUMEN

OBJECTIVE: To evaluate the experiences of families with very young children aged 1 to 7 years (inclusive) with type 1 diabetes using day-and-night hybrid closed-loop insulin delivery. METHODS: Parents/caregivers of 20 children aged 1 to 7 years with type 1 diabetes completed a closed-loop experience survey following two 3-week periods of unrestricted day-and-night hybrid closed-loop insulin therapy using Cambridge FlorenceM system at home. Benefits, limitations, and improvements of closed-loop technology were explored. RESULTS: Responders reported reduced burden of diabetes management, less time spent managing diabetes, and improved quality of sleep with closed-loop. Ninety percent of the responders felt less worried about their child's glucose control using closed-loop. Size of study devices, battery performance and connectivity issues were identified as areas for improvement. Parents/caregivers wished for more options to input information to the system such as temporary glucose targets. CONCLUSIONS: Parents/caregivers of very young children reported important quality of life benefits associated with using closed-loop, supporting adoption of this technology in this population.


Asunto(s)
Costo de Enfermedad , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Calidad de Vida , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea , Cuidadores/psicología , Cuidadores/estadística & datos numéricos , Niño , Preescolar , Ritmo Circadiano/fisiología , Estudios Cruzados , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 1/psicología , Familia/psicología , Femenino , Humanos , Lactante , Insulina/efectos adversos , Masculino , Padres/psicología , Encuestas y Cuestionarios
14.
Diabetologia ; 64(6): 1455, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33751132
15.
Diabetes Technol Ther ; 26(4): 211-221, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38426909

RESUMEN

Introduction: The Closing the Loop in Adults With Type 1 Diabetes (CLEAR) randomized crossover study compared a novel fully closed-loop insulin delivery system with no carbohydrate entry or mealtime bolusing (CamAPS HX), with standard insulin pump therapy and glucose sensor in adults with type 1 diabetes and suboptimal glycemic outcomes. This qualitative substudy aimed to understand the psychosocial impact of using the fully automated system. Materials and Methods: Adults participating in the CLEAR study were invited to take part in a virtual semistructured interview after they had completed 8 weeks using the fully closed-loop system. Recruitment continued until there was adequate representation and data saturation occurred. Interviews were anonymized and transcribed for in-depth thematic analysis using an inductive-deductive approach. Study participants were also asked to complete questionnaires assessing diabetes distress, hypoglycemia confidence, and closed-loop treatment satisfaction. Results: Eleven participants (eight male and three female; age range 26-66 years) were interviewed. After an initial adjustment period, interviewees reported enjoying a reduction in diabetes burden, freed-up mental capacity, and improved mood. All were happy with overnight glycemic outcomes, with the majority reporting benefits on sleep. Although experiences of postprandial glucose outcomes varied, all found mealtimes easier and less stressful, particularly when eating out. Negatives raised by participants predominantly related to the insulin pump hardware, but some also reported increased snacking and challenges around resuming carbohydrate counting at trial closeout. Conclusions: In adults with type 1 diabetes, use of a fully closed-loop insulin delivery system had significant quality-of-life benefits and provided a welcome break from the day-to-day demands of living with diabetes. Clinical Trial Registration: NCT04977908.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Adulto , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Glucemia , Hipoglucemiantes/uso terapéutico , Estudios Cruzados , Resultado del Tratamiento , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico
16.
Artículo en Inglés | MEDLINE | ID: mdl-38315506

RESUMEN

Objective: To evaluate postprandial glucose control when applying (1) faster-acting insulin aspart (Fiasp) compared to insulin aspart and (2) ultra-rapid insulin lispro (Lyumjev) compared to insulin lispro using the CamAPS FX hybrid closed-loop algorithm. Research Design and Methods: We undertook a secondary analysis of postprandial glucose excursions from two double-blind, randomized, crossover hybrid closed-loop studies contrasting Fiasp to standard insulin aspart, and Lyumjev to standard insulin lispro. Endpoints included incremental area under curve (iAUC)-2h, iAUC-4h, 4 h postprandial time in target range, time above range, and time below range. It was approved by independent research ethics committees. Results: Two trials with 8 weeks of data from 51 adults with type 1 diabetes were analyzed and 7137 eligible meals were included. During Lyumjev compared with insulin lispro, iAUC-2h and iAUC-4h were significantly decreased following breakfast (mean difference 92 mmol/L per 2 h (95% confidence interval [CI]: 56 to 127); P < 0.001 and 151 mmol/L per 4 h (95% CI: 74 to 229); P < 0.001, respectively) and the evening meal (P < 0.001 and P = 0.011, respectively). Mean time in target range (3.9-10.0 mmol/L) for 4 h postprandially significantly increased during Lyumjev with a mean difference of 6.7 percentage points (95% CI: 3.3 to 10) and 5.7 percentage points (95% CI: 1.4 to 9.9) for breakfast and evening meal, respectively. In contrast, there were no significant differences in iAUC-2h, iAUC-4h, and the other measures of postprandial glucose control between insulin aspart and Fiasp during breakfast, lunch, and evening meal (P > 0.05). Conclusion: The use of Lyumjev with CamAPS FX closed-loop system improved postprandial glucose excursions compared with insulin lispro, while the use of Fiasp did not provide any advantage compared with insulin aspart. Clinical Trial Registration numbers: NCT04055480, NCT05257460.

17.
J Diabetes Sci Technol ; : 19322968241242803, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613227

RESUMEN

BACKGROUND: CamAPS HX fully closed-loop (FCL) system, with no user input required at mealtimes, has been shown to be safe and effective in adults with type 1 and type 2 diabetes. We assessed whether time spent in hypoglycemia and hyperglycemia during FCL insulin delivery in adults varied by type of diabetes over the 24-hour period. METHODS: We retrospectively analyzed eight weeks of data from 52 participants (adults with type 1 diabetes and adults with insulin-treated type 2 diabetes) recruited to two single-center randomized controlled studies using FCL insulin delivery during unrestricted-living conditions. Key outcomes were time spent in hypoglycemia <70 mg/dL and marked hyperglycemia >300 mg/dL by type of diabetes. RESULTS: The median percentage of time spent in hypoglycemia <70 mg/dL over the 24-hour period was lower for those with type 2 diabetes than for those with type 1 diabetes (median [interquartile range (IQR)] 0.43% [0.20-0.77] vs 0.86%, [0.54-1.46]; mean difference 0.46 percentage points [95% CI 0.23-0.70]; P < .001). Median percentage time in marked hyperglycemia >300 mg/dL was lower for those with type 2 diabetes than for those with type 1 diabetes (median [IQR] 1.8% [0.6-3.5] vs 9.3% [6.9-11.8]; mean difference 7.8 percentage points [95% CI 5.5-10.0]; P < .001). CONCLUSIONS: Using the FCL system, hypoglycemia and marked hyperglycemia exposure were lower in type 2 diabetes than in type 1 diabetes.

18.
Diabetes Technol Ther ; 26(3): 198-202, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38444312

RESUMEN

The presence of diabetic ketoacidosis (DKA) at diagnosis of type 1 diabetes (T1D) is associated with higher glycated hemoglobin levels over time. We evaluated whether hybrid-closed loop (HCL) therapy from onset of T1D could prevent the adverse impact of DKA at diagnosis on long-term glycemic outcomes. This was a posthoc analysis from 51 adolescents using HCL from diagnosis of T1D as part of the CLOuD trial (NCT02871089). We compared glycemic and insulin metrics between adolescents with (n = 17) and without (n = 34) DKA at diagnosis. Participants with and without DKA at diagnosis had similar time in target glucose range 3.9-10.0 mmol/L (70-180 mg/dL), time below range (<3.9 mmol/L, <70 mg/dL) and HbA1c at 6, 12, and 24 months. While insulin requirements at 6 months were higher in those with DKA at diagnosis, this was not statistically significant after adjusting for bodyweight. Residual C-peptide secretion was similar between groups. We conclude that HCL therapy may mitigate against the negative glycemic effects of DKA at T1D diagnosis.


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Adolescente , Humanos , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Cetoacidosis Diabética/etiología , Glucemia , Sistemas de Infusión de Insulina , Insulina Regular Humana
19.
Diabetes Care ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38924772

RESUMEN

OBJECTIVE: We evaluated the effect of long-term intensive metabolic control with hybrid closed-loop (CL) on residual C-peptide secretion and glucose control compared with standard insulin therapy in youth with type 1 diabetes over 48 months. RESEARCH DESIGN AND METHODS: Following the 24-month primary phase of a multicenter, randomized, parallel trial of 96 newly diagnosed youth aged 10 to 16.9 years, participants were invited to an extension phase using treatment allocated at randomization. They continued with hybrid CL using the Cambridge algorithm or standard insulin therapy (control) until 48 months after diagnosis. Analysis was by intention-to-treat. RESULTS: At 24 months after diagnosis, 81 participants (mean ± SD age 14 ± 2 years) continued in the extension phase (47 CL, 34 control). There was no difference in fasting C-peptide corrected for fasting glucose at 48 months between groups (CL: 5 ± 9 vs. control: 6 ± 14 pmol/L per mmol/L; mean adjusted difference -2 [95% CI -7, 4; P = 0.54]). Central laboratory HbA1c remained lower in the CL group by 0.9% (10 mmol/mol [95% CI 0.2, 1.5; 3, 17 mmol/mol); P = 0.009). Time in target range of 3.9 to 10.0 mmol/L was 12 percentage points (95% CI 3, 20; P = 0.008) higher in the CL group compared with control. There were 11 severe hypoglycemic events (6 CL, 5 control) and 7 diabetic ketoacidosis events (3 CL, 4 control) during the extension phase. CONCLUSIONS: Improved glycemic control was sustained over 48 months after diagnosis with CL insulin delivery compared with standard therapy in youth with type 1 diabetes. This did not appear to confer a protective effect on residual C-peptide secretion.

20.
J Diabetes Sci Technol ; : 19322968241231950, 2024 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-38494876

RESUMEN

BACKGROUND/OBJECTIVE: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). METHODS: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. RESULTS: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). CONCLUSIONS: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA