1.
Breast Cancer Res Treat ; 203(1): 135-143, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37787819

RESUMEN

PURPOSE: To compare the diagnostic performance (detection, assessment of correct disease extent and multifocality/centricity) of Contrast-Enhanced Mammography (CEM) Versus Breast Magnetic Resonance (MRI) in the study of lobular neoplasms. METHODS: We retrospectively selected all the patients who underwent surgery for a lobular breast neoplasm, either an in situ or an invasive tumor, and had undergone both breast CEM and MRI examinations during the pre-surgical planning. Wilcoxon Signed Rank test was performed to assess the differences between size measurements using the different methods and the post-surgical pathological measurements, considered the gold standard. The agreement in identifying multifocality/multicentricity among the different methods and the pathology was assessed using the Kappa statistics. RESULTS: We selected 19 patients, of which one presented a bilateral neoplasm. Then, the images of these 19 patients were analyzed, for a total of 52 malignant breast lesions. We found no significant differences between the post-surgical pathological size of the lesions and the calculated size with CEM and MRI (p-value of the difference respectively 0.71 and 0.47). In all 20 cases, neoplasm detection was possible both with CEM and MRI. CEM and MRI showed an excellent ability to identify multifocal and multicentric cases (K statistic equal to 0.93 for both the procedures), while K statistic was 0.11 and 0.59 for FFDM and US, respectively. CONCLUSION: The findings of this study suggest that CEM is a reliable imaging technique in the preoperative setting of patients with lobular neoplasm, with comparable results to breast MRI.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Estudios Retrospectivos , Medios de Contraste , Mamografía/métodos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Sensibilidad y Especificidad
2.
Breast Cancer Res Treat ; 202(3): 451-459, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37747580

RESUMEN

OBJECTIVE: Breast magnetic resonance imaging (MRI) and contrast-enhanced mammography (CEM) are nowadays used in breast imaging but studies about their inter-reader agreement are lacking. Therefore, we compared the inter-reader agreement of CEM and MRI in breast cancer diagnosis in the same patients. METHODS: Breast MRI and CEM exams performed in a single center (09/2020-09/2021) for an IRB-approved study were retrospectively and independently evaluated by four radiologists of two different centers with different levels of experience who were blinded to the clinical and other imaging data. The reference standard was the histological diagnosis or at least 1-year negative imaging follow-up. Inter-reader agreement was examined using Cohen's and Fleiss' kappa (κ) statistics and compared with the Wald test. RESULTS: Of the 750 patients, 395 met inclusion criteria (44.5 ± 14 years old), with 752 breasts available for CEM and MRI. Overall agreement was moderate (κ = 0.60) for MRI and substantial (κ = 0.74) for CEM. For expert readers, the agreement was substantial (κ = 0.77) for MRI and almost perfect (κ = 0.82) for CEM; for non-expert readers was fair (κ = 0.39); and for MRI and moderate (κ = 0.57) for CEM. Pairwise agreement between expert readers and non-expert readers was moderate (κ = 0.50) for breast MRI and substantial (κ = 0.74) for CEM and it showed a statistically superior agreement of the expert over the non-expert readers only for MRI (p = 0.011) and not for CEM (p = 0.062). CONCLUSIONS: The agreement of CEM was superior to that of MRI (p = 0.012), including for both expert (p = 0.031) and non-expert readers (p = 0.005).

3.
Medicina (Kaunas) ; 59(9)2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37763661

RESUMEN

Background and Objectives: Breast cancer (BC) is a leading cause of morbidity and mortality worldwide, and accurate assessment of axillary lymph nodes (ALNs) is crucial for patient management and outcomes. We aim to summarize the current state of ALN assessment techniques in BC and provide insights into future directions. Materials and Methods: This review discusses various imaging techniques used for ALN evaluation, including ultrasound, computed tomography, magnetic resonance imaging, and positron emission tomography. It highlights advancements in these techniques and their potential to improve diagnostic accuracy. The review also examines landmark clinical trials that have influenced axillary management, such as the Z0011 trial and the IBCSG 23-01 trial. The role of artificial intelligence (AI), specifically deep learning algorithms, in improving ALN assessment is examined. Results: The review outlines the key findings of these trials, which demonstrated the feasibility of avoiding axillary lymph node dissection (ALND) in certain patient populations with low sentinel lymph node (SLN) burden. It also discusses ongoing trials, including the SOUND trial, which investigates the use of axillary ultrasound to identify patients who can safely avoid sentinel lymph node biopsy (SLNB). Furthermore, the potential of emerging techniques and the integration of AI in enhancing ALN assessment accuracy are presented. Conclusions: The review concludes that advancements in ALN assessment techniques have the potential to improve patient outcomes by reducing surgical complications while maintaining accurate disease staging. However, challenges such as standardization of imaging protocols and interpretation criteria need to be addressed. Future research should focus on large-scale clinical trials to validate emerging techniques and establish their efficacy and cost-effectiveness. Over-all, this review provides valuable insights into the current status and future directions of ALN assessment in BC, highlighting opportunities for improving patient care.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Metástasis Linfática/patología , Inteligencia Artificial , Ganglios Linfáticos/patología , Biopsia del Ganglio Linfático Centinela/métodos , Escisión del Ganglio Linfático , Axila
4.
Medicina (Kaunas) ; 59(9)2023 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-37763797

RESUMEN

Standardized radiological reports stimulate debate in the medical imaging field. This review paper explores the advantages and challenges of standardized reporting. Standardized reporting can offer improved clarity and efficiency of communication among radiologists and the multidisciplinary team. However, challenges include limited flexibility, initially increased time and effort, and potential user experience issues. The efforts toward standardization are examined, encompassing the establishment of reporting templates, use of common imaging lexicons, and integration of clinical decision support tools. Recent technological advancements, including multimedia-enhanced reporting and AI-driven solutions, are discussed for their potential to improve the standardization process. Organizations such as the ACR, ESUR, RSNA, and ESR have developed standardized reporting systems, templates, and platforms to promote uniformity and collaboration. However, challenges remain in terms of workflow adjustments, language and format variability, and the need for validation. The review concludes by presenting a set of ten essential rules for creating standardized radiology reports, emphasizing clarity, consistency, and adherence to structured formats.


Asunto(s)
Radiología , Humanos , Radiografía , Comunicación , Lenguaje , Flujo de Trabajo
5.
Breast Cancer Res Treat ; 196(2): 371-377, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36114939

RESUMEN

PURPOSE: To present an overview of the management of male patients with Ductal Carcinoma In Situ of the breast (male DCIS). METHODS: We retrospectively studied all male patients with a diagnosis of pure DCIS from January 1999 to December 2018: 20 patients were identified in our cancer referral center. We collected data regarding clinical presentation, age of onset, radiological features, receptor status of the neoplasm, histological type, and the follow-up of those patients. RESULTS: The median age was 62 years (range 21-80). All patients underwent surgery, in 15/20 (75%) cases a mastectomy was carried out. Two patients (10%) underwent endocrine treatment and 1/20 (5%) underwent radiotherapy. The receptor status for 15/20 patients was documented: 13/15 patients were ER+/Pr+. In 3 cases the Ki 67% was positive (i.e., > 20%). All cases were negative for Her2. The median follow-up time was 9.0 years (IQR 4.0-13.7). Only one patient had an ipsilateral recurrence with the finding of an infiltrating carcinoma in the same breast after 14 years. The 5-year disease-free survival was 92.9%. CONCLUSION: Pure DCIS in men is an extremely rare disease: proper diagnosis and management allow an excellent prognosis.


Asunto(s)
Neoplasias de la Mama Masculina , Neoplasias de la Mama , Carcinoma Ductal de Mama , Carcinoma Intraductal no Infiltrante , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/terapia , Carcinoma Ductal de Mama/patología , Carcinoma Intraductal no Infiltrante/diagnóstico por imagen , Carcinoma Intraductal no Infiltrante/terapia , Antígeno Ki-67 , Mastectomía , Mastectomía Segmentaria , Recurrencia Local de Neoplasia/patología , Derivación y Consulta , Estudios Retrospectivos
6.
Radiol Med ; 127(11): 1228-1234, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36149581

RESUMEN

PURPOSE: To compare the accuracy of Contrast-Enhanced Spectral Mammography (CESM), MG, US, and breast MRI in estimating the size of breast lesions requiring surgery. The postoperative histology size of the lesion was used as the gold standard. MATERIAL AND METHODS: Two hundred thirty-three non-benign lesions in 189 patients were included in the analyses. All the selected patients underwent CESM and at least one other conventional diagnostic exam (US, MG, or MRI). Subsequently, all the patients underwent surgery preceded by cytological/histological examination. The largest diameter of the lesion at imaging was measured by a radiologist with more than 10 years' experience and then compared with the size of the lesion in the histological sample at the surgery (gold standard). RESULTS: Among the 233 breast lesions, 196 were evaluated with US, 206 with MG and 160 with MRI. We found no statistically significant differences between size measurements using CESM and MRI compared with the measurements at the surgery (p value 0.63 and 0.51), whereas a significant difference was found for MG and US (p < 0.001). CONCLUSION: CESM is a reliable method for estimating the size of breast lesions: its performance seems superior to US and MG and comparable to MRI.


Asunto(s)
Neoplasias de la Mama , Neoplasias , Humanos , Femenino , Medios de Contraste , Mamografía/métodos , Mama/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/patología , Sensibilidad y Especificidad
7.
Int J Mol Sci ; 23(23)2022 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-36499648

RESUMEN

We aimed to investigate the association between the radiomic features of contrast-enhanced spectral mammography (CESM) images and a specific receptor pattern of breast neoplasms. In this single-center retrospective study, we selected patients with neoplastic breast lesions who underwent CESM before a biopsy and surgical assessment between January 2013 and February 2022. Radiomic analysis was performed on regions of interest selected from recombined CESM images. The association between the features and each evaluated endpoint (ER, PR, Ki-67, HER2+, triple negative, G2-G3 expressions) was investigated through univariate logistic regression. Among the significant and highly correlated radiomic features, we selected only the one most associated with the endpoint. From a group of 321 patients, we enrolled 205 malignant breast lesions. The median age at the exam was 50 years (interquartile range (IQR) 45-58). NGLDM_Contrast was the only feature that was positively associated with both ER and PR expression (p-values = 0.01). NGLDM_Coarseness was negatively associated with Ki-67 expression (p-value = 0.02). Five features SHAPE Volume(mL), SHAPE_Volume(vx), GLRLM_RLNU, NGLDM_Busyness and GLZLM_GLNU were all positively and significantly associated with HER2+; however, all of them were highly correlated. Radiomic features of CESM images could be helpful to predict particular molecular subtypes before a biopsy.


Asunto(s)
Neoplasias de la Mama , Humanos , Persona de Mediana Edad , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Estudios Retrospectivos , Antígeno Ki-67 , Medios de Contraste , Mamografía/métodos
8.
Breast J ; 27(6): 514-520, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33677844

RESUMEN

In the last few years, ultrasound-guided vacuum-assisted breast biopsy (US-VABB) has replaced surgical biopsy due to higher diagnostic accuracy and lower patient discomfort, and, at present, an even greater possibility is represented by the new wireless ultrasound-guided VAB device (Wi-UVAB). The purpose of our study is to determine the diagnostic accuracy of this new device in a sizeable representative number of patients. From January 2014 to June 2018, 168 biopsies were performed in our institution using the new Wi-UVAB device. We analyzed sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of biopsies obtained with the new device using surgical results as reference point, following patients for at least one year. In our cohort, we obtained a complete sensitivity of 97.5%, an absolute sensitivity of 94.3%, a complete specificity of 98%, and an absolute specificity of 98%. The positive predictive value of the procedure was 97.5% while the negative predictive value was 98%. The diagnostic accuracy was 98%. The Wi-UVAB is a safe procedure with high diagnostic accuracy, comparable to that of the traditional vacuum-assisted breast biopsy and even higher than that of core needle biopsy (CNB). Moreover, the Wi-UVAB is easy to use and shows low costs as core needle biopsy (CNB).


Asunto(s)
Neoplasias de la Mama , Biopsia con Aguja Gruesa , Mama/diagnóstico por imagen , Mama/cirugía , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Biopsia Guiada por Imagen , Estudios Retrospectivos , Ultrasonografía , Ultrasonografía Intervencional
9.
Cytopathology ; 32(3): 312-317, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33606300

RESUMEN

INTRODUCTION: Air-dried slide preparation for fine needle aspiration cytology procedures is currently considered unsafe because of the risk of infectious aerosols of coronavirus 19. This study compares the safety and accuracy of two different protocols, one with and one without air-dried slides. METHODS: Starting from 3 March 2020, we discontinued the use of air-dried slides during breast fine needle aspiration procedures. We selected cases collected during two periods: 2 months before and 2 months after 3 March. In both groups, the number of procedures was recorded together with the distribution of the diagnostic categories and the concordance between cytological and histological results on surgical specimens for lesions suggestive of malignancy, using the chi-squared test. RESULTS: Of the 100 procedures performed during the pre-COVID-19 period, 55% were negative (C2), 3% were non-diagnostic (C1) and 40% were positive (C4 or C5). Of the 75 procedures obtained during the COVID-19 period, 44% were negative (C2), 2.7% were non-diagnostic (C1) and 52% were positive (C4 or C5). Despite the use of a new protocol during the COVID-19 period, we observed concordance between cytological and histological results for lesions suggestive of malignancy. There was no statistically significant difference concerning the distribution of the diagnostic categories in the two groups. CONCLUSIONS: Taking into account the slightly lower number of procedures being analysed during the COVID-19 period, the introduction of a new protocol that does not include air-dried slides is safe and reliable.


Asunto(s)
Neoplasias de la Mama , Mama/patología , COVID-19 , SARS-CoV-2 , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Fina , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
10.
Breast Cancer Res Treat ; 184(3): 723-731, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32860166

RESUMEN

PURPOSE: To compare the efficacy of contrast-enhanced spectral mammography, with ultrasound, full field digital mammography and magnetic resonance imaging in detection and size estimation of histologically proven breast tumors. METHODS: This open-label, single center, prospective study, included 160 dense breast women with at least one suspicious mammary lesion evaluated by ultrasound, full field digital mammography and magnetic resonance imaging in whom a mammary tumor was histologically proven after surgery performed at the European Institute of Oncology between January 2013 and December 2015. Following the complete diagnostic procedure, the patients were further investigated by contrast-enhanced spectral mammography prior to surgery. RESULTS: Overall, the detection rate of malignant breast lesions (in situ and invasive) was 93.8% (165/176) for contrast-enhanced spectral mammography, 94.4% (168/178) for ultrasound, 85.5 (147/172) for full field digital mammography and 97.7% (173/177) for magnetic resonance imaging. Radiological measurements were concordant with the post-surgical pathological measurements of the invasive tumor (i.e., within 5 mm) in: 64.6% for contrast-enhanced spectral mammography, 62.0% for ultrasound, 45.2% for full field digital mammography (p < 0.0001) and 69.9% for magnetic resonance imaging (p = 0.28); underestimated in: 17.4% for contrast-enhanced spectral mammography, 19.6% for ultrasound, 24.2% for full field digital mammography (p = 0.03) and 6.7% for magnetic resonance imaging (p = 0.0005); and overestimated in: 16.2% for contrast-enhanced spectral mammography, 16.6% for ultrasound, 16.6% for full field digital mammography and 22.7% for magnetic resonance imaging (p = 0.02). CONCLUSIONS: Our data suggest that contrast-enhanced spectral mammography improves on full field digital mammography and is comparable to ultrasound and magnetic resonance imaging in terms of detection sensitivity and size estimation of malignant lesions in dense breasts.


Asunto(s)
Neoplasias de la Mama , Mamografía , Mama/diagnóstico por imagen , Mama/cirugía , Densidad de la Mama , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Medios de Contraste , Femenino , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos , Sensibilidad y Especificidad
11.
Eur Radiol ; 24(7): 1651-8, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24744196

RESUMEN

OBJECTIVES: To evaluate the underestimation rate and clinical relevance of lobular neoplasia in vacuum-assisted breast biopsy (VABB). METHODS: A total of 161 cases of LN were retrieved from 6,435 VABB. The histological diagnosis was ALH (atypical lobular hyperplasia) in 80 patients, LCIS (lobular carcinoma in situ) in 69 patients and PLCIS (pleomorphic lobular carcinoma in situ) in 12 patients. Seventy-six patients were operated on within 2 years after VABB and 85 were clinically and radiologically monitored. The mean follow-up was 5.2 years, and the prevalence of malignancy was evaluated in the group of 85 patients. RESULTS: The clinico-pathological characteristics significantly favouring surgery were larger lesions, occurrence of a residual lesion following VABB and histological LCIS and PLCIS subtypes. The VABB underestimation rate as compared to surgery was 7.1% for ALH, 12% for LCIS and 50% for PLCIS. Overall, 11 of the 148 patients included in this survival analysis developed an ipsilateral tumour. CONCLUSION: Although obtained retrospectively in a relatively small series of patients, our data suggest that only patients with a diagnosis of PLCIS in VABB should be treated with surgery, whereas patients with ALH and LCIS could be monitored by clinical and radiological examinations. KEY POINTS: • The treatment of ALH and LCIS in VABB is still debated • Some authors favour radical treatment and others a more conservative approach • Only patients with PLCIS in VABB should be treated by surgery.


Asunto(s)
Adenocarcinoma in Situ/diagnóstico , Biopsia con Aguja/métodos , Neoplasias de la Mama/diagnóstico , Mama/patología , Carcinoma Lobular/diagnóstico , Adenocarcinoma in Situ/epidemiología , Adulto , Anciano , Neoplasias de la Mama/epidemiología , Carcinoma Lobular/epidemiología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Persona de Mediana Edad , Estadificación de Neoplasias/métodos , Estudios Retrospectivos , Vacio
12.
J Clin Med ; 13(15)2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39124573

RESUMEN

Radiological interpretations, while essential, are not infallible and are best understood as expert opinions formed through the evaluation of available evidence. Acknowledging the inherent possibility of error is crucial, as it frames the discussion on improving diagnostic accuracy and patient care. A comprehensive review of error classifications highlights the complexity of diagnostic errors, drawing on recent frameworks to categorize them into perceptual and cognitive errors, among others. This classification underpins an analysis of specific error types, their prevalence, and implications for clinical practice. Additionally, we address the psychological impact of radiological practice, including the effects of mental health and burnout on diagnostic accuracy. The potential of artificial intelligence (AI) in mitigating errors is discussed, alongside ethical and regulatory considerations in its application. This research contributes to the body of knowledge on radiological errors, offering insights into preventive strategies and the integration of AI to enhance diagnostic practices. It underscores the importance of a nuanced understanding of errors in radiology, aiming to foster improvements in patient care and radiological accuracy.

13.
Diagnostics (Basel) ; 14(1)2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38201413

RESUMEN

The primary aim of our study was to assess the main mammographic and ultrasonographic features of invasive male breast malignancies. The secondary aim was to evaluate whether a specific radiological presentation would be associated with a worse receptor profile. Radiological images (mammography and/or ultrasound) of all patients who underwent surgery for male invasive breast cancer in our institution between 2008 and 2023 were retrospectively analyzed by two breast radiologists in consensus. All significant features of radiological presentation known in the literature were re-evaluated. Fifty-six patients were selected. The mean age at surgery of patients was 69 years (range: 35-81); in 82% of cases (46 patients), the histologic outcome was invasive ductal carcinoma. A total of 28 out of 56 (50%) patients had preoperative mammography; in 9/28 cases (32%), we found a mass with microcalcifications on mammography. The mass presented high density in 25 out of 28 patients (89%); the mass showed irregular margins in 15/28 (54%) cases. A total of 46 out of 56 patients had preoperative ultrasounds. The lesion showed a solid mass in 41/46 (89%) cases. In 5/46 patients (11%), the lesion was a mass with a mixed (partly liquid-partly solid) structure. We did not find any statistically significant correlation between major types of radiological presentation and tumor receptor arrangement. Knowledge of the main radiologic presentation patterns of malignant male breast neoplasm can help better manage this type of disease, which is rare but whose incidence is increasing.

14.
Insights Imaging ; 15(1): 37, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38332410

RESUMEN

Contrast-enhanced mammography (CEM) is a relatively recent diagnostic technique increasingly being utilized in clinical practice. Until recently, there was a lack of standardized reporting for CEM findings. However, this has changed with the publication of a supplement in the Breast Imaging Reporting and Data System (BI-RADS). A comprehensive understanding of CEM is essential for further enhancing its role in both screening and managing patients with breast malignancies. CEM can also be beneficial for problem-solving, improving the management of uncertain breast findings. Practitioners in this field should become more cognizant of how and when to employ this technique and interpret the various CEM findings. This paper aims to outline the key findings in the updated version of the BI-RADS specifically dedicated to CEM. Additionally, it will present some clinical cases commonly encountered in clinical practice.Critical relevance statement Standardized reporting and a thorough understanding of CEM findings are pivotal for advancing the role of CEM in screening and managing breast cancer patients. This standardization contributes significantly to integrating CEM as an essential component of daily clinical practice.Key points • A complete knowledge and understanding of the findings outlined in the new BI-RADS CEM are necessary for accurate reporting.• BI-RADS CEM supplement is intuitive and practical to use.• Standardization of the CEM findings enables more accurate patient management.

15.
Cancers (Basel) ; 16(4)2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38398228

RESUMEN

This retrospective study investigates the histopathological outcomes, upgrade rates, and disease-free survival (DFS) of high-risk breast lesions, including atypical ductal hyperplasia (ADH or DIN1b) and lobular in situ neoplasms (LIN), following Vacuum-Assisted Breast Biopsy (VABB) and surgical excision. The study addresses the challenge posed by these lesions due to their association with synchronous or adjacent Breast Cancer (BC) and increased future BC risk. The research, comprising 320 patients who underwent stereotactic VABB, focuses on 246 individuals with a diagnosis of ADH (120) or LIN (126) observed at follow-up. Pathological assessments, categorized by the UK B-coding system, were conducted, and biopsy samples were compared with corresponding excision specimens to determine upgrade rates for in situ or invasive carcinoma. Surgical excision was consistently performed for diagnosed ADH or LIN. Finally, patient follow-ups were assessed and compared between LIN and ADH groups to identify recurrence signs, defined as histologically confirmed breast lesions on either the same or opposite side. The results reveal that 176 (71.5%) patients showed no upgrade post-surgery, with ADH exhibiting a higher upgrade rate to in situ pathology than LIN1 (Atypical Lobular Hyperplasia, ALH)/LIN2 (Low-Grade Lobular in situ Carcinoma, LCIS) (38% vs. 20%, respectively, p-value = 0.002). Considering only patients without upgrade, DFS at 10 years was 77%, 64%, and 72% for ADH, LIN1, and LIN2 patients, respectively (p-value = 0.92). The study underscores the importance of a multidisciplinary approach, recognizing the evolving role of VABB. It emphasizes the need for careful follow-up, particularly for lobular lesions, offering valuable insights for clinicians navigating the complex landscape of high-risk breast lesions. The findings advocate for heightened awareness and vigilance in managing these lesions, contributing to the ongoing refinement of clinical strategies in BC care.

16.
Diagnostics (Basel) ; 13(12)2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37370892

RESUMEN

PURPOSE: This study aimed to investigate the use of contrast-free magnetic resonance imaging (MRI) as an innovative screening method for detecting breast cancer in high-risk asymptomatic women. Specifically, the researchers evaluated the diagnostic performance of diffusion-weighted imaging (DWI) in this population. METHODS: MR images from asymptomatic women, carriers of a germline mutation in either the BRCA1 or BRCA2 gene, collected in a single center from January 2019 to December 2021 were retrospectively evaluated. A radiologist with experience in breast imaging (R1) and a radiology resident (R2) independently evaluated DWI/ADC maps and, in case of doubts, T2-WI. The standard of reference was the pathological diagnosis through biopsy or surgery, or ≥1 year of clinical and radiological follow-up. Diagnostic performances were calculated for both readers with a 95% confidence interval (CI). The agreement was assessed using Cohen's kappa (κ) statistics. RESULTS: Out of 313 women, 145 women were included (49.5 ± 12 years), totaling 344 breast MRIs with DWI/ADC maps. The per-exam cancer prevalence was 11/344 (3.2%). The sensitivity was 8/11 (73%; 95% CI: 46-99%) for R1 and 7/11 (64%; 95% CI: 35-92%) for R2. The specificity was 301/333 (90%; 95% CI: 87-94%) for both readers. The diagnostic accuracy was 90% for both readers. R1 recalled 40/344 exams (11.6%) and R2 recalled 39/344 exams (11.3%). Inter-reader reproducibility between readers was in moderate agreement (κ = 0.43). CONCLUSIONS: In female carriers of a BRCA1/2 mutation, breast DWI supplemented with T2-WI allowed breast cancer detection with high sensitivity and specificity by a radiologist with extensive experience in breast imaging, which is comparable to other screening tests. The findings suggest that DWI and T2-WI have the potential to serve as a stand-alone method for unenhanced breast MRI screening in a selected population, opening up new perspectives for prospective trials.

17.
Acad Radiol ; 30(10): 2243-2251, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36898907

RESUMEN

RATIONALE AND OBJECTIVES: The new version of the Contrast Enhanced Mammography (CEM) Breast imaging Reporting and Data System (BIRADs) encourages investigations of a new enhancement descriptor: "Lesion Conspicuity" (LC). The study aims to assess the diagnostic performance and the relationship with the receptor profile of this new enhancement descriptor. MATERIALS AND METHODS: Three hundred twenty-five patients with 381 breast lesions who underwent CEM before histological assessmentwere selected. Four radiologists, blinded to each other, categorized LC into the following levels: absent, low, moderate, and high. Considering moderate and high evaluations as predictive of malignancy, the diagnostic performance of CEM was calculated using histological results of the biopsy as the gold standard. The association between LC values and the receptor profile of the neoplasms was also evaluated. RESULTS: The median age at the CEM examination was 50 years (IQR: 45-59). Considering the value of LC of the most experienced radiologist with the interpretation of Low Energy images (LE), we obtained a sensitivity (SE) of 91.9% (95% CI: 88.6%-95.2%) and a specificity (SP) of 67.2% (95% CI: 58.9%-75.5%). An association between "high" lesion conspicuity with ER/PgR not expressed (p = 0.025), with Ki-67>20% (p = 0.033), and with Grading G3 (p = 0.020) was observed. CONCLUSION: The new feature of enhancement, "Lesion Conspicuity", demonstrated satisfactory performance in predicting the malignancy of lesions and significant correlation with the receptor profile of malignant breast neoplasms.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Humanos , Persona de Mediana Edad , Femenino , Mamografía/métodos , Neoplasias de la Mama/patología , Biopsia , Radiólogos
18.
Healthcare (Basel) ; 11(4)2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36833045

RESUMEN

The aim of this study was to evaluate the diagnostic performance of contrast-enhanced spectral mammography (CESM) in predicting breast lesion malignancy due to microcalcifications compared to lesions that present with other radiological findings. Three hundred and twenty-one patients with 377 breast lesions that underwent CESM and histological assessment were included. All the lesions were scored using a 4-point qualitative scale according to the degree of contrast enhancement at the CESM examination. The histological results were considered the gold standard. In the first analysis, enhancement degree scores of 2 and 3 were considered predictive of malignity. The sensitivity (SE) and positive predictive value (PPV) were significative lower for patients with lesions with microcalcifications without other radiological findings (SE = 53.3% vs. 82.2%, p-value < 0.001 and PPV = 84.2% vs. 95.2%, p-value = 0.049, respectively). On the contrary, the specificity (SP) and negative predictive value (NPV) were significative higher among lesions with microcalcifications without other radiological findings (SP = 95.8% vs. 84.2%, p-value = 0.026 and NPV = 82.9% vs. 55.2%, p-value < 0.001, respectively). In a second analysis, degree scores of 1, 2, and 3 were considered predictive of malignity. The SE (80.0% vs. 96.8%, p-value < 0.001) and PPV (70.6% vs. 88.3%, p-value: 0.005) were significantly lower among lesions with microcalcifications without other radiological findings, while the SP (85.9% vs. 50.9%, p-value < 0.001) was higher. The enhancement of microcalcifications has low sensitivity in predicting malignancy. However, in certain controversial cases, the absence of CESM enhancement due to its high negative predictive value can help to reduce the number of biopsies for benign lesions.

19.
Cancers (Basel) ; 15(21)2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37958452

RESUMEN

Mammary Paget disease (MPD) is a rare condition primarily affecting adult women, characterized by unilateral skin changes in the nipple-areolar complex (NAC) and frequently associated with underlying breast carcinoma. Histologically, MPD is identified by large intraepidermal epithelial cells (Paget cells) with distinct characteristics. Immunohistochemical profiles aid in distinguishing MPD from other skin conditions. Clinical evaluation and imaging techniques, including magnetic resonance imaging (MRI), are recommended if MPD is suspected, although definitive diagnosis always requires histological examination. This review delves into the historical context, epidemiology, pathogenesis, clinical manifestations, and diagnosis of MPD, emphasizing the need for early detection. The classification of MPD based on pathogenesis is explored, shedding light on its varied presentations. Treatment options, including mastectomy and breast-conserving surgery, are discussed with clear guidelines for different scenarios. Adjuvant therapies are considered, particularly in cases with underlying breast cancer. Prognostic factors are outlined, underlining the importance of early intervention. Looking to the future, emerging techniques, like liquid biopsy, new immunohistochemical and molecular markers, and artificial intelligence-based image analysis, hold the potential to transform MPD diagnosis and treatment. These innovations offer hope for early detection and improved patient care, though validation through large-scale clinical trials is needed.

20.
Healthcare (Basel) ; 11(11)2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37297735

RESUMEN

Breast cancer is the most common forms of cancer and a leading cause of mortality in women. Early and correct diagnosis is, therefore, essential to save lives. The development of diagnostic imaging applied to the breast has been impressive in recent years and the most used diagnostic test in the world is mammography, a low-dose X-ray technique used for imaging the breast. In the first half of the 20th century, the diagnosis was in practice only clinical, with consequent diagnostic delay and an unfavorable prognosis in the short term. The rise of organized mammography screening has led to a remarkable reduction in mortality through the early detection of breast malignancies. This historical review aims to offer a complete panorama of the development of mammography and breast imaging during the last century. Through this study, we want to understand the foundations of the pillar of radiology applied to the breast through to the most modern applications such as contrast-enhanced mammography (CEM), artificial intelligence, and radiomics. Understanding the history of the development of diagnostic imaging applied to the breast can help us understand how to better direct our efforts toward an increasingly personalized and effective diagnostic approach. The ultimate goal of imaging applied to the detection of breast malignancies should be to reduce mortality from this type of disease as much as possible. With this paper, we want to provide detailed documentation of the main steps in the evolution of breast imaging for the diagnosis of breast neoplasms; we also want to open up new scenarios where the possible current and future applications of imaging are aimed at being more precise and personalized.