RESUMEN
The aim of this study was to adapt impedance methodology to study esophagogastric junction (EGJ) sphincter opening and compare opening patterns of the EGJ during deglutitive LES relaxation (dLESR) and transient LES relaxation (tLESR). We studied eight healthy subjects with a novel 12-lumen combined impedance/manometry catheter, the main element of which was a 6 cm sleeve sensor with six side hole sensors and six impedance rings spaced at 1 cm increments along its length. Subjects underwent an air infusion protocol after standard assessment and data tracings and isocontour plots were analysed to assess opening characteristics of the EGJ during dLESRs and tLESRs. Our results revealed that during dLESR the opening pattern was top to bottom, occurred in 0-2.7 s and in 29 of 35 (83%) cases the leading edge of the bolus was liquid. Opening during tLESR began between -7.8 and +8.6 s relative to the onset of nadir LES relaxation. The opening pattern during tLESR was bottom to top, occurred in 0-7.7 s, and in 22 of 29 (76%) the leading edge was liquid. These results support that impedance monitoring can be adapted to identify sphincter opening, to distinguish sphincter opening from sphincter relaxation, and to determine luminal contents during the opening period.
Asunto(s)
Deglución/fisiología , Esfínter Esofágico Inferior/fisiología , Unión Esofagogástrica/fisiología , Pletismografía de Impedancia/instrumentación , Pletismografía de Impedancia/métodos , Adulto , Cateterismo/instrumentación , Femenino , Humanos , Masculino , ManometríaRESUMEN
This study characterized oesophageal shortening during secondary peristalsis and transient lower oesophageal sphincter relaxation (TLOSR) in an attempt to determine its contribution to the opening mechanism. Eight healthy subjects (four males, 26 +/- 1 years) had metal clips affixed at 0, +3, and +8 cm relative to the squamocolumnar junction (SCJ), defining two distal oesophageal segments. Axial clip movement was assessed with concurrent videofluoroscopy and manometry during primary peristalsis, secondary peristalsis and TLOSR. Clip-defined oesophageal segment length change was measured at 0.5-s intervals. The magnitude of the most distal segment shortening was least with TLOSR, greatest with primary peristalsis and intermediate with secondary peristalsis. Conversely, maximal overall oesophageal shortening during TLOSR, evidenced by SCJ movement, was similar to that during primary peristalsis. In 3/12 TLOSRs, the moment of LOS opening and gas reflux was optimally imaged; SCJ excursion was 0.3 +/- 0.1 cm prior to LOS opening and 1.4 +/- 0.7 cm immediately after gas reflux. The segmental pattern of oesophageal shortening was distinct during primary peristalsis, secondary peristalsis and TLOSR. During TLOSR, significant elevation of the SCJ occurred only after LOS opening, suggesting that this was a consequence of oesophageal distension induced by gas reflux rather than a component of the opening mechanism.
Asunto(s)
Unión Esofagogástrica/fisiología , Esófago/fisiología , Relajación Muscular/fisiología , Adulto , Análisis de Varianza , Femenino , Humanos , Masculino , Contracción Muscular/fisiología , Peristaltismo/fisiologíaRESUMEN
BACKGROUND AND AIMS: High-resolution manometry (HRM) is a recent development in oesophageal measurement; its value in the clinical setting remains a matter of controversy. (i) We compared the accuracy with which bolus transport could be predicted from conventional manometry and HRM. (ii) The clinical value of HRM was assessed in a series of patients with endoscopy-negative dysphagia in whom conventional investigations had been non-diagnostic. METHOD: (i) Control subjects and patients with endoscopy-negative dysphagia underwent concurrent HRM and video-fluoroscopy. Ninety-five records were reviewed using HRM with spatiotemporal plot and conventional line plots of the pressure data derived from the same recording. (ii) The HRM and notes of patients with endoscopy-negative dysphagia and abnormal bolus transport were analysed to identify additional information provided by the new technique. RESULTS: (i) Receiver operating characteristic analysis demonstrated that HRM predicts the presence of abnormal bolus transport more accurately than conventional manometry. (ii) HRM identified clinically important motor dysfunction not detected by manometry and radiography. These included localized disturbances of peristalsis and abnormal movement of the lower oesophageal sphincter during oesophageal spasm. CONCLUSION: The HRM predicts bolus movement more accurately than conventional manometry and identifies clinically relevant oesophageal dysfunction not detected by other investigations including conventional manometry.
Asunto(s)
Trastornos de Deglución/diagnóstico , Esófago/fisiología , Manometría/métodos , Peristaltismo/fisiología , Adulto , Trastornos de Deglución/fisiopatología , Esfínter Esofágico Inferior/fisiología , Femenino , Humanos , Masculino , Persona de Mediana EdadRESUMEN
Whereas previous studies have shown that ultrasonic backscatter and Doppler power from blood are affected by flow turbulence, turbulence level has only been inferred from the flow Reynolds number and not directly measured. In this study, both ultrasonic Doppler power and flow turbulence intensity were measured in situ to quantify the relationship between Doppler power and flow turbulence. Three grid meshes of different geometries were used in a steady-flow mock loop to generate controlled levels of flow turbulence in porcine red blood cell saline suspensions. Doppler power was measured by a 10-MHz PW Doppler flowmeter, and the turbulence intensity by using constant-temperature hot film anemometry. We showed that Doppler power is affected by turbulence and hematocrit in a complex way. At a fixed hematocrit, Doppler power increases nonlinearly with turbulence intensity and, at fixed turbulence intensity, Doppler power peaks at an optimal hematocrit level that increases with turbulence level. The shape factor, introduced by Lucas and Twersky (1987) to take into account effects of shape and orientation of the scatterers in a dense distribution of small and tenuous scatterers, was estimated by fitting the experimental data to the theoretical model. The results indicate that shape factor decreases with increasing turbulence intensity.
Asunto(s)
Eritrocitos/fisiología , Flujometría por Láser-Doppler , Ultrasonografía Doppler , Animales , Velocidad del Flujo Sanguíneo , Tamaño de la Célula , Eritrocitos/diagnóstico por imagen , Hematócrito , Modelos Teóricos , Reproducibilidad de los Resultados , PorcinosRESUMEN
BACKGROUND: Anesthetics are commonly applied in animal studies of gastrointestinal (GI) function. Different anesthetics alter smooth-muscle motility in different ways. The aim of this study is to quantify and compare non-invasively with magnetic resonance imaging (MRI) the motility patterns of the rat gut when anesthetized with inactin vs isoflurane anesthetics in the fed state. METHODS: Rats were given an oral gavage of MRI contrast agent for improved visualization of the GI tract. Two-dimensional images through the jejunum of the pre- and postanesthetized rat in the fed state were acquired every 168 ms. Image registration, segmentation, and postprocessing algorithms were applied to produce spatio-temporal maps that were used to quantify peristaltic and segmental motions in the jejunum region interspersed between periods of inactivity. KEY RESULTS: There were significantly longer periods of inactivity in the rats treated with isoflurane than in those treated with inactin (179.9 ± 22.4 s vs 17.7 ± 10.3 s). The speed of propagation and wavelength of peristalsis, and the frequency and speed of pattern switching of segmental motility, were higher (p < 0.05) in rats treated with inactin. CONCLUSIONS & INFERENCES: Isoflurane and inactin anesthetics produce significantly different motility behavior with the rat's GI tract in the fed state. Isoflurane anesthetic, results in a reduced frequency of occurrence of motility periods and an overall reduced level of motility in comparison with inactin.
Asunto(s)
Anestésicos por Inhalación/farmacología , Motilidad Gastrointestinal/efectos de los fármacos , Isoflurano/farmacología , Tiopental/análogos & derivados , Animales , Imagen por Resonancia Magnética , Ratas , Tiopental/farmacologíaRESUMEN
Gastric emptying (GE) may be driven by tonic contraction of the stomach ('pressure pump') or antral contraction waves (ACW) ('peristaltic pump'). The mechanism underlying GE was studied by contrasting the effects of clonidine (alpha(2)-adrenergic agonist) and sumatriptan (5-HT(1) agonist) on gastric function. Magnetic resonance imaging provided non-invasive assessment of gastric volume responses, ACW and GE in nine healthy volunteers. Investigations were performed in the right decubitus position after ingestion of 500 mL of 10% glucose (200 kcal) under placebo [0.9% NaCl intravenous (IV) and subcutaneous (SC)], clonidine [0.01 mg min(-1) IV, max 0.1 mg (placebo SC)] or sumatriptan [6 mg SC (placebo IV)]. Total gastric volume (TGV) and gastric content volume (GCV) were assessed every 5 min for 90 min, interspersed with dynamic scan sequences to measure ACW activity. During gastric filling, TGV increased with GCV indicating that meal volume dictates initial relaxation. Gastric contents volume continued to increase over the early postprandial period due to gastric secretion surpassing initial gastric emptying. Clonidine diminished this early increase in GCV, reduced gastric relaxation, decreased ACW frequency compared with placebo. Gastric emptying (GE) rate increased. Sumatriptan had no effect on initial GCV, but prolonged gastric relaxation and disrupted ACW activity. Gastric emptying was delayed. There was a negative correlation between gastric relaxation and GE rate (r(2 )=49%, P < 0.001), whereas the association between ACW frequency and GE rate was inconsistent and weak (r2=15%, P = 0.05). These findings support the hypothesis that nutrient liquid emptying is primarily driven by the 'pressure pump' mechanism.
Asunto(s)
Clonidina/farmacología , Vaciamiento Gástrico/efectos de los fármacos , Motilidad Gastrointestinal/efectos de los fármacos , Periodo Posprandial/fisiología , Estómago/anatomía & histología , Sumatriptán/farmacología , Agonistas alfa-Adrenérgicos/farmacología , Adulto , Presión Sanguínea/fisiología , Vaciamiento Gástrico/fisiología , Motilidad Gastrointestinal/fisiología , Frecuencia Cardíaca/fisiología , Humanos , Imagen por Resonancia Magnética , Manometría , Tamaño de los Órganos/efectos de los fármacos , Peristaltismo/efectos de los fármacos , Peristaltismo/fisiología , Antro Pilórico/anatomía & histología , Antro Pilórico/fisiología , Agonistas de Receptores de Serotonina/farmacología , Estómago/fisiologíaRESUMEN
Distinct contraction waves (CWs) exist above and below the transition zone (TZ) between the striated and smooth muscle oesophagus. We hypothesize that bolus transport is impaired in patients with abnormal spatio-temporal coordination and/or contractile pressure in the TZ. Concurrent high resolution manometry and digital fluoroscopy were performed in healthy subjects and patients with reflux oesophagitis; a condition associated with ineffective oesophageal contractility and clearance. A detailed analysis of space-time variations in bolus movement, intra-bolus and intra-luminal pressure was performed on 17 normal studies and nine studies in oesophagitis patients with impaired bolus transit using an interactive computer based system. Compared with normal controls, oesophagitis patients had greater spatial separation between the upper and lower CW tails [median 5.2 cm (range 4.4-5.6) vs 3.1 cm (2.2-3.7)], the average relative pressure within the TZ region (TZ strength) was lower [30.8 mmHg (28.3-36.5) vs 45.8 mmHg (36.1-55.7), P < 0.001], and the risk of bolus retention was higher (90%vs 12%; P < 0.01). The presence of bolus retention was associated with a wider spatial separation of the upper and lower CWs (>3 cm, the upper limit of normal; P < 0.002), independent of the presence of oesophagitis. We conclude that bolus retention in the TZ is associated with excessively wide spatial separation between the upper and lower CWs and lower TZ muscle squeeze. These findings provide a physio-mechanical basis for the occurrence of bolus retention at the level of the aortic arch, and may underlie impaired clearance with reflux oesophagitis.
Asunto(s)
Trastornos de Deglución/patología , Esófago , Fluoroscopía/métodos , Manometría/métodos , Deglución/fisiología , Esofagitis Péptica/patología , Esofagitis Péptica/fisiopatología , Esófago/anatomía & histología , Esófago/fisiología , Humanos , Peristaltismo/fisiologíaRESUMEN
The discussion centers on the use of mechanical principles, mathematical modeling, and concurrent manometric and videofluoroscopic data to study the esophageal function. Basic principles of mechanics indicate that intrabolus pressure must be distinguished from the direct contractile squeeze of the circular muscle on the manometric assembly. Because these two regions are mechanically distinct, pressure amplitude is not a proper indicator of the forces characterizing esophageal bolus transport. In the application of computer simulations to the transport of a fluid bolus through the aortic arch regions, it was discovered that separate contraction waves must exist in the upper and lower esophageal segments when bolus retention occurs. Through detailed analysis of enhanced concurrent manometric and videofluoroscopic data in human volunteers, we have found that a dual-wave characteristic across the transition zone is a normal reflection of the change in muscle types, each muscle type producing a separate contraction wave. In normal transport, these two contraction waves are properly coordinated spatially and temporally. However, during bolus retention, a mismatch in space and time between these two waves takes place. Analysis suggests that this mismatch is neurological rather than histological in origin, and occurs primarily within the lower smooth-muscle segment.
Asunto(s)
Esófago/fisiología , Peristaltismo/fisiología , Deglución/fisiología , Trastornos de Deglución/diagnóstico , Trastornos de Deglución/diagnóstico por imagen , Esófago/diagnóstico por imagen , Femenino , Fluoroscopía , Humanos , Masculino , ManometríaRESUMEN
Intraperitoneal injection of CaCl2 in intact, sham-stanniectomized, and stanniectomized American eels, Anguilla rostrata (LeSueur), resulted in a rapid elevation of plasma calcium level which was more marked and of longer duration in the stanniectomized eels. The same treatment reduced whole body calcium influx (JinCa2+) in the intact and sham-stanniectomized groups for the first but not the second of two 4 hr flux periods. The same treatment did not affect JinCa2+ in the stanniectomized eels. We conclude that calcium loading in eels with intact stannius corpuscles (CS) results in the release of a CS hormone (stanniocalcin) which inhibits the uptake of calcium from the environment and that this facilitates the return to normocalcemia. These data provide direct evidence for a relationship between stanniocalcin release in vivo and a hypocalcemic response and the first evidence concerning the functional turnover time of this hormone.
Asunto(s)
Anguilla/sangre , Calcio/sangre , Glándulas Endocrinas/fisiología , Hormonas , Animales , Calcio/metabolismo , Glándulas Endocrinas/cirugía , Glicoproteínas/fisiología , Hipercalcemia/metabolismoRESUMEN
A unified discussion of the mechanics of the swallowing process, and its interpretation through manometric measurements of intraluminal pressure, are presented in this paper. The goals of the discussions are to provide the reader with basic knowledge of pharyngeal, esophageal, and sphincter mechanics; to relate the mechanical processes to intraluminal pressure recordings; and to clarify the relationship between intraluminal pressure and esophageal muscle contractile behavior. The esophageal phase of bolus transport, in particular, is discussed in some detail due to the relatively simple geometry and the straightforward description of peristalsis and muscle mechanics in this region. Several important issues are emphasized in the discussion. For example, pressure variation within a static bolus is fundamentally different from that within a moving bolus. Manometric recordings must be interpreted accordingly. The importance of differentiating between "hydrodynamic pressure," which is pressure measured within a fluid bolus, and "contact pressure," which is the direct squeeze of the luminal wall on the manometric port in a region devoid of bolus fluid, is discussed in some detail. We argue that pressure "amplitude" does not, in principle, give any indication of the forces required to drive the fluid bolus forward. What should be sought is the variation of intrabolus pressure relative to the contact pressure, particularly during periods in which the contractile segment fails to obliterate the esophageal lumen. Examples of intraluminal pressure recording in the esophagus, using manometry and mathematical models, are presented to demonstrate both the possibilities and the difficulties of interpreting manometric recordings in the absence of concurrent radiographic imaging. We discover that in regions of nearly complete luminal closure, the pressure signature and bolus geometry are strongly coupled during peristaltic transport, providing the possibility that in these regions quantitative measures of muscle performance might be developed without the need for radiographic imaging. On the other hand, the ambiguity in the interpretation of manometric recordings that often accompanies dysphagic conditions suggests that as more sophisticated interpretations are sought, manometry concurrent with radiography will play a more prominent role in patient evaluation.
Asunto(s)
Deglución/fisiología , Esófago/fisiología , Manometría , Faringe/fisiología , Fenómenos Biofísicos , Biofisica , Trastornos de Deglución/diagnóstico , Esófago/diagnóstico por imagen , Modelos Biológicos , Peristaltismo/fisiología , Faringe/diagnóstico por imagen , Presión , RadiografíaRESUMEN
Mathematical modeling and computer simulations are combined with concurrent manometric and videofluoroscopic data to analyze the contractile behavior of the esophageal wall during normal and abnormal esophageal bolus transport. The study focuses on axial variations in intraluminal pressure in relationship to deformations of the esophageal wall during the transport process. Four case studies of esophageal bolus transport described by Kahrilas et al. (Gastroenterology 94: 73-80, 1988), one normal and three abnormal, are analyzed in detail by capturing the major elements of both the videofluoroscopic and concurrent manometric data in the mathematical model. In all cases a strong correlation between the deformations of the luminal wall and the axial variations of intraluminal pressure is observed. Simulation of normal bolus transport shows that, whereas only gentle variations in intrabolus pressure occur in the main body of the bolus due to weak frictional forces there, large frictional forces force a rapid rise in pressure near the bolus tail induced by circular muscle squeeze. Of particular interest is the analysis of incomplete clearance of bolus fluid in the aortic arch region. The only physically correct model consistent both with the videofluoroscopic and the manometric data implies the existence of two separate contraction waves, one above and one below the transition zone.(ABSTRACT TRUNCATED AT 250 WORDS)
Asunto(s)
Simulación por Computador , Esófago/fisiología , Esófago/fisiopatología , Modelos Biológicos , Animales , Transporte Biológico , Fluoroscopía , Humanos , Manometría , Peristaltismo , Valores de Referencia , TelevisiónRESUMEN
Detailed viscosity measurements have been made of barium sulfate mixtures over a wide range of viscosities for use in radiography of the esophagus, stomach, and duodenum. A new methodology was developed for more accurate estimation of viscosity in non-Newtonian fluids in conventional cylinder-type viscometers. As base cases, the variation of viscosity with shear rate was measured for standard commercial mixes of e.z.hd (250% w/v) and a diluted mixture of liquid e.z.paque (40% w/v). These suspensions are strongly shear thinning at low shear rates. Above about 3s-1 the viscosity is nearly constant, but relatively low. To increase the viscosity of the barium sulfate mixture, Knott's strawberry syrup was mixed to different proportions with e.z.hd powder. In this way viscosity was systematically increased to values 130,000 times that of water. For these mixtures the variation of viscosity with temperature, and the change in mixture density with powder-syrup ratio are documented. From least-square fits through the data, simple mathematical formulas are derived for approximate calculation of viscosity as a function of mixture ratio and temperature. These empirical formulas should be useful in the design of "test kits" for systematic study for pharyngeal and esophageal motility, and clinical analysis of motility disorders as they relate to bolus consistency.
Asunto(s)
Sulfato de Bario , Deglución , Esófago/diagnóstico por imagen , Faringe/diagnóstico por imagen , Esófago/fisiología , Humanos , Peristaltismo , Faringe/fisiología , Radiografía , ViscosidadRESUMEN
We analyzed local longitudinal shortening by combining concurrent ultrasonography and manometry with basic principles of mechanics. We applied the law of mass conservation to quantify local axial shortening of the esophageal wall from ultrasonically measured cross-sectional area concurrently with measured intraluminal pressure, from which correlations between local contraction of longitudinal and circular muscle are inferred. Two clear phases of local longitudinal shortening were observed during bolus transport. During luminal filling by bolus fluid, the muscle layer distends and the muscle thickness decreases in the absence of circular or longitudinal muscle contraction. This is followed by local contraction, first in longitudinal muscle, then in circular muscle. Maximal longitudinal shortening occurs nearly coincidently with peak intraluminal pressure. Longitudinal muscle contraction begins before and ends after circular muscle contraction. Larger longitudinal shortening is correlated with higher pressure amplitude, suggesting that circumferential contractile forces are enhanced by longitudinal muscle shortening. We conclude that a peristaltic wave of longitudinal muscle contraction envelops the wave of circular muscle contraction as it passes through the middle esophagus, with peak longitudinal contraction aligned with peak circular muscular contraction. Our results suggest that the coordination of the two waves may be a physiological response to the mechanical influence of longitudinal shortening, which increases contractile force while reducing average muscle fiber tension by increasing circular muscle fiber density locally near the bolus tail.
Asunto(s)
Esófago/fisiología , Contracción Muscular/fisiología , Músculo Liso/fisiología , Deglución , Esófago/diagnóstico por imagen , Humanos , Músculo Liso/diagnóstico por imagen , Peristaltismo , Estadística como Asunto , UltrasonografíaRESUMEN
We applied high-resolution manometry with spatiotemporal data interpolation and simultaneous videofluoroscopy to normal pharyngeal swallows to correlate specific features in the space-time intraluminal pressure structure with physiological events and normal deglutitive transsphincteric bolus flow to define normal biomechanical properties of the pharyngo-esophageal (PE) segment. Pressures were recorded by microperfused catheter, and the two-dimensional space-time data sets were plotted as isocontours. On these were superimposed bolus trajectories, anatomic segment movements, and hyo-laryngeal trajectories from concurrent videofluoroscopy. Correlation of the highly reproducible space-time-pressure structure with radiographic images confirmed that primary deglutitive PE segment functions (pressure profile, laryngeal elevation, axial sphincter motion, timing of relaxation, contraction) are accurately discernible from single isocontour pressure visualization. Pressure during bolus flow was highly dependent on axial location within PE segment and time instant. The intrabolus pressure domain, corresponding to the space-time region between bolus head and tail trajectories, demonstrated significant bolus volume dependence. High-resolution manometry accurately, comprehensively, and highly reproducibly depicts the PE segment space-time-pressure structure and specific physiological events related to upper esophageal sphincter opening and transsphincteric flow during normal swallowing. Intrabolus pressure variations are highly dependent on position within the PE segment and time.
Asunto(s)
Deglución/fisiología , Esófago/fisiología , Faringe/fisiología , Adulto , Unión Esofagogástrica/fisiología , Femenino , Humanos , Hueso Hioides/fisiología , Laringe/fisiología , Masculino , Manometría , Movimiento (Física) , Presión , Factores de TiempoRESUMEN
The mechanics of phrenic ampullary emptying were analyzed to determine whether this structure functions in a manner similar to the tubular esophagus or a hiatal hernia. Simultaneous videofluoroscopy and intraluminal manometry of the gastroesophageal junction were done during barium swallows in 18 normal volunteers. Esophageal emptying was studied without any external influences, during abdominal compression with a cuff inflated to 100 mmHg, during a Müller maneuver, and after medication with atropine. The key finding of the study was that ampullary emptying was distinct from esophageal bolus transport in several ways: the propagation velocity of the clearing wave was slower, the maximal contact pressures achieved after luminal closure were lower and unaffected by atropine or outflow obstruction, and ampulary emptying was driven by a hydrostatic pressure difference between the ampulla and stomach rather than by a peristaltic contraction. Increased bolus volume slightly enlarged the ampulla. Taken together, these findings suggest that ampullary emptying occurs, in part, as a result of the restoration of esophageal length (presumably by tension from the phrenoesophageal membrane) rather than as a result of an aborally propagated contraction. As such, a normal phrenic ampulla is analogous to a small reducing hiatal hernia. We speculate that overt hernia formation occurs as a result of progressive degeneration of the phrenoesophageal membrane.
Asunto(s)
Tejido Elástico/fisiología , Unión Esofagogástrica/fisiología , Esófago/fisiología , Hernia Hiatal/etiología , Adulto , Deglución/fisiología , Fluoroscopía , Humanos , Masculino , Manometría , Peristaltismo/fisiología , Presión , TelevisiónRESUMEN
The findings of concurrent esophageal videofluoroscopy and manometry in 15 patients with major disturbances of esophageal motor function were evaluated and the data were analyzed from a fluid mechanical perspective. Each of 153 fluoroscopic barium swallow sequences was analyzed on a swallow-by-swallow basis. Two distinct pressure domains were identified: intrabolus pressure and pressure within a bolus-free contracting esophageal segment. Analyses in terms of these pressure domains showed specific and consistent correlations between the radiographic and manometric findings. Radiography was insensitive to contractions occurring in esophageal segments devoid of bolus fluid, whereas manometry was insensitive to contractions that did not occlude the lumen. It is concluded that using fluid mechanical principles of bolus transport allows meaningful comparison of esophageal motility as recorded by radiography and intraluminal manometry. However, the inherent limitations in the range of physical phenomena recorded by each modality make these techniques complementary for evaluating esophageal motor function.
Asunto(s)
Trastornos de la Motilidad Esofágica/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Deglución/fisiología , Trastornos de la Motilidad Esofágica/diagnóstico por imagen , Trastornos de la Motilidad Esofágica/fisiopatología , Femenino , Fluoroscopía/métodos , Humanos , Masculino , Manometría , Persona de Mediana Edad , Contracción Muscular/fisiología , Peristaltismo/fisiología , PresiónRESUMEN
This study analyzed the effect of fundoplication on the mechanics of liquid and solid bolus transit across the esophagogastric junction (EGJ). The squamocolumnar junction was endoscopically clipped in seven controls, seven hiatal hernia patients, and seven patients after laparoscopic Nissen fundoplication. Concurrent manometry and fluoroscopy were done during swallows of liquid barium and a 13-mm-diameter marshmallow. The EGJ opening, pressure gradients, transit efficacy, and axial motion were measured. The axial motion of the EGJ was reduced in the fundoplication and hiatal hernia patients. The opening dimensions at the squamocolumnar junction were similar among groups, but in each case the constriction limiting flow to the stomach was at the hiatus and this was substantially narrowed with fundoplication. As a result, liquid intrabolus pressure was increased and marshmallow transit frequently required multiple swallows. We conclude that fundoplication limits the axial mobility of the EGJ and leads to a restricted hiatal opening. These alterations decrease the efficacy of solid and liquid transit into the stomach and are potential causes of dysphagia in this population.
Asunto(s)
Deglución/fisiología , Unión Esofagogástrica/fisiopatología , Fundoplicación , Adulto , Fenómenos Biomecánicos , Ingestión de Líquidos/fisiología , Ingestión de Alimentos/fisiología , Fluoroscopía , Hernia Hiatal/fisiopatología , Humanos , Manometría , Persona de Mediana Edad , Periodo Posoperatorio , Valores de Referencia , Factores de TiempoRESUMEN
INTRODUCTION: Dysphagia is common after Nissen fundoplication but the relationship between dysphagia and bolus transit is poorly defined. This study compared bolus transit of fundoplication patients to normal individuals. METHODS: Twelve fundoplication patients and 20 healthy volunteers rated their ability to swallow eight bolus consistencies from no difficulty (0) to extreme difficulty (3) to compute a dysphagia score (range = 0-24). A 16-lumen manometric assembly was positioned across the esophagogastric junction (EGJ) and subjects were imaged fluoroscopically in a supine posture while swallowing 5 cc liquid barium and a 5-cc marshmallow-like viscoelastic barium bolus. Videofluoroscopic images were analyzed for total esophageal transit time and the fraction of time required to cross the EGJ. Manometric tracings were analyzed for the intrabolus pressure proximal to the EGJ, intragastric pressure, and distal peristaltic amplitude for each bolus. RESULTS: Dysphagia scores for fundoplication patients were significantly higher (7.3 +/- 5.1, range = 1-17) than for normals (0.5 +/- 0.6, range = 0-2). This correlated with longer total transit times for liquids and solids (r = 0.60, P < 0.01) and a greater percentage of transit time attributable to the EGJ transit. Retrograde flow at the EGJ (escape of bolus proximally up the esophagus) and peristaltic dysfunction were more frequent in fundoplication patients. However, no differences existed in manometric parameters between groups. CONCLUSIONS: Fundoplication impairs both liquid and solid esophageal bolus transit. Dysphagia perceived by fundoplication patients correlated with increased transit time, particularly across the EGJ. Combined quantitative evaluation with manometry and fluoroscopy reveals functional defects in fundoplication subjects, which are not evident by either modality alone.
Asunto(s)
Trastornos de Deglución/diagnóstico , Esófago/fisiopatología , Fundoplicación , Complicaciones Posoperatorias/diagnóstico , Adulto , Anciano , Bario , Deglución/fisiología , Técnicas de Diagnóstico del Sistema Digestivo , Ingestión de Líquidos , Ingestión de Alimentos , Elasticidad , Humanos , Persona de Mediana Edad , Estrés Fisiológico , Factores de TiempoRESUMEN
Patients with a prominent cricopharyngeal bar visible on radiography are generally considered to have spasm of the cricopharyngeus, which is the major muscle component of the upper esophageal sphincter. This condition has been termed "cricopharyngeal achalasia." The aim of this study was to determine the pathogenesis of cricopharyngeal bars. Concurrent videofluoroscopic and manometric examinations of the pharynx and upper esophageal sphincter were performed in a cohort of six patients with prominent cricopharyngeal bars and in eight control volunteers. In each subject, swallows of 2-30-mL barium boluses were recorded. The patients with cricopharyngeal bars showed (a) normal peristaltic contraction in the pharynx, (b) normal axial upper esophageal sphincter pressure and relaxation, (c) normal flow rate across the upper esophageal sphincter, and (d) normal duration of upper esophageal sphincter opening for different bolus volumes. The major abnormalities in the patients with cricopharyngeal bars were (a) reduced maximal dimensions of the upper esophageal sphincter during the transsphincteric flow of barium and (b) increased intrabolus pressure upstream to the upper esophageal sphincter. Thus, the increase in intrabolus pressure preserved normal transsphincteric flow rates even though the upper esophageal sphincter did not open normally. Overall, the constellation of findings in the patients studied suggests that the underlying pathogenesis of their cricopharyngeal bar was reduced muscle compliance wherein the relaxed cricopharyngeus did not distend normally during swallowing.
Asunto(s)
Cartílago Cricoides/fisiopatología , Laringe/fisiopatología , Faringe/fisiopatología , Adulto , Anciano , Bario , Fenómenos Biomecánicos , Cartílago Cricoides/diagnóstico por imagen , Cartílago Cricoides/fisiología , Deglución , Femenino , Humanos , Laringe/diagnóstico por imagen , Laringe/fisiología , Masculino , Manometría , Persona de Mediana Edad , Relajación Muscular , Faringe/diagnóstico por imagen , Faringe/fisiología , Presión , RadiografíaRESUMEN
The relative contributions to gastric emptying from common cavity antroduodenal pressure difference ("pressure pump") vs. propagating high-pressure waves in the distal antrum ("peristaltic pump") were analyzed in humans by high-resolution manometry concurrently with time-resolved three-dimensional magnetic resonance imaging during intraduodenal nutrient infusion at 2 kcal/min. Gastric volume, space-time pressure, and contraction wave histories in the antropyloroduodenal region were measured in seven healthy subjects. The subjects fell into two distinct groups with an order of magnitude difference in levels of antral pressure activity. However, there was no significant difference in average rate of gastric emptying between the two groups. Antral pressure history was separated into "propagating high-pressure events" (HPE), "nonpropagating HPEs," and "quiescent periods." Quiescent periods dominated, and average pressure during quiescent periods remained unchanged with decreasing gastric volume, suggesting that common cavity pressure levels were maintained by increasing wall muscle tone with decreasing volume. When propagating HPEs moved to within 2-3 cm of the pylorus, pyloric resistance was found statistically to increase with decreasing distance between peristaltic waves and the pylorus. We conclude that transpyloric flow tends to be blocked when antral contraction waves are within a "zone of influence" proximal to the pylorus, suggesting physiological coordination between pyloric and antral contractile activity. We further conclude that gastric emptying of nutrient liquids is primarily through the "pressure pump" mechanism controlled by pyloric opening during periods of relative quiescence in antral contractile wave activity.