Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Adv Drug Deliv Rev ; 197: 114824, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37068660

RESUMEN

Mental illnesses including anxiety disorders, autism spectrum disorder, post-traumatic stress disorder, schizophrenia, depression, and others exact an immense toll on the healthcare system and society at large. Depression alone impacts 21 million adults and costs over $200 billion annually in the United States. However, pharmaceutical strategies to treat mental illnesses are lagging behind drug development in many other disease areas. Because many of the shortcomings of therapeutics for mental illness relate to delivery problems, drug delivery technologies have the potential to radically improve the effectiveness of therapeutics for these diseases. This review describes the current pharmacotherapeutic approaches to treating mental illnesses as well as drug delivery approaches that have improved existing therapies. Approaches to improve drug bioavailability, provide controlled release of therapeutics, and enable drug targeting to the central nervous system (CNS) will be highlighted. Moreover, next-generation delivery approaches such as environmentally-controlled release and interval/sequential drug release will be addressed. Based on the evolving landscape of the treatment of mental illnesses, the nascent field of drug delivery in mental health has tremendous potential for growth in terms of both economic and patient impact.


Asunto(s)
Trastorno del Espectro Autista , Trastornos Mentales , Farmacia , Adulto , Humanos , Estados Unidos , Preparaciones de Acción Retardada , Trastornos Mentales/tratamiento farmacológico , Sistemas de Liberación de Medicamentos
2.
J Biomed Mater Res A ; 111(6): 790-800, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36606344

RESUMEN

There is an urgent unmet medical need to develop therapeutic options for the ~50% of depression patients suffering from treatment-resistant depression, which is difficult to treat with existing psycho- and pharmaco-therapeutic options. Classical psychedelics, such as the 5HT2A agonists, have re-emerged as a treatment paradigm for depression. Recent clinical trials highlight the potential effectiveness of 5HT2A agonists to improve mood and psychotherapeutic growth in treatment-resistant depression patients, even in those who have failed a median of four previous medications in their lifetime. Moreover, microdosing could be a promising way to achieve long-term alleviation of depression symptoms without a hallucinogenic experience. However, there are a gamut of practical barriers that stymie further investigation of microdosing 5HT2A agonists, including: low compliance with the complicated dosing regimen, high risk of diversion of controlled substances, and difficulty and cost administering the long-term treatment regimens in controlled settings. Here, we developed a drug delivery system composed of multilayered cellulose acetate phthalate (CAP)/Pluronic F-127 (P) films for the encapsulation and interval delivery of 5HT2A agonists from a fully biodegradable and biocompatible implant. CAPP film composition, thickness, and layering strategies were optimized, and we demonstrated three distinct pulses from the multilayered CAPP films in vitro. Additionally, the pharmacokinetics and biodistribution of the 5HT2A agonist 2,5-Dimethoxy-4-iodoamphetamine (DOI) were quantified following the subcutaneous implantation of DOI-loaded single and multilayered CAPP films. Our results demonstrate, for the first time, the interval delivery of psychedelics from an implantable drug delivery system and open the door to future studies into the therapeutic potential of psychedelic delivery.


Asunto(s)
Alucinógenos , Humanos , Polímeros , Distribución Tisular , Preparaciones Farmacéuticas
3.
Abdom Radiol (NY) ; 43(12): 3307-3316, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29700590

RESUMEN

PURPOSE: To evaluate precision of a software-based liver surface nodularity (LSN) score derived from CT images. METHODS: An anthropomorphic CT phantom was constructed with simulated liver containing smooth and nodular segments at the surface and simulated visceral and subcutaneous fat components. The phantom was scanned multiple times on a single CT scanner with adjustment of image acquisition and reconstruction parameters (N = 34) and on 22 different CT scanners from 4 manufacturers at 12 imaging centers. LSN scores were obtained using a software-based method. Repeatability and reproducibility were evaluated by intraclass correlation (ICC) and coefficient of variation. Using abdominal CT images from 68 patients with various stages of chronic liver disease, inter-observer agreement and test-retest repeatability among 12 readers assessing LSN by software- vs. visual-based scoring methods were evaluated by ICC. RESULTS: There was excellent repeatability of LSN scores (ICC:0.79-0.99) using the CT phantom and routine image acquisition and reconstruction parameters (kVp 100-140, mA 200-400, and auto-mA, section thickness 1.25-5.0 mm, field of view 35-50 cm, and smooth or standard kernels). There was excellent reproducibility (smooth ICC: 0.97; 95% CI 0.95, 0.99; CV: 7%; nodular ICC: 0.94; 95% CI 0.89, 0.97; CV: 8%) for LSN scores derived from CT images from 22 different scanners. Inter-observer agreement for the software-based LSN scoring method was excellent (ICC: 0.84; 95% CI 0.79, 0.88; CV: 28%) vs. good for the visual-based method (ICC: 0.61; 95% CI 0.51, 0.69; CV: 43%). Test-retest repeatability for the software-based LSN scoring method was excellent (ICC: 0.82; 95% CI 0.79, 0.84; CV: 12%). CONCLUSION: The software-based LSN score is a quantitative CT imaging biomarker with excellent repeatability, reproducibility, inter-observer agreement, and test-retest repeatability.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Hígado/diagnóstico por imagen , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA