Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 19(3): 227-233, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29664225

RESUMEN

BACKGROUND: Metal artifacts caused by high-density implants lead to incorrectly reconstructed Hounsfield units in computed tomography images. This can result in a loss of accuracy in dose calculation in radiation therapy. This study investigates the potential of the metal artifact reduction algorithms, Augmented Likelihood Image Reconstruction and linear interpolation, in improving dose calculation in the presence of metal artifacts. MATERIALS AND METHODS: In order to simulate a pelvis with a double-sided total endoprosthesis, a polymethylmethacrylate phantom was equipped with two steel bars. Artifacts were reduced by applying the Augmented Likelihood Image Reconstruction, a linear interpolation, and a manual correction approach. Using the treatment planning system Eclipse™, identical planning target volumes for an idealized prostate as well as structures for bladder and rectum were defined in corrected and noncorrected images. Volumetric modulated arc therapy plans have been created with double arc rotations with and without avoidance sectors that mask out the prosthesis. The irradiation plans were analyzed for variations in the dose distribution and their homogeneity. Dosimetric measurements were performed using isocentric positioned ionization chambers. RESULTS: Irradiation plans based on images containing artifacts lead to a dose error in the isocenter of up to 8.4%. Corrections with the Augmented Likelihood Image Reconstruction reduce this dose error to 2.7%, corrections with linear interpolation to 3.2%, and manual artifact correction to 4.1%. When applying artifact correction, the dose homogeneity was slightly improved for all investigated methods. Furthermore, the calculated mean doses are higher for rectum and bladder if avoidance sectors are applied. CONCLUSION: Streaking artifacts cause an imprecise dose calculation within irradiation plans. Using a metal artifact correction algorithm, the planning accuracy can be significantly improved. Best results were accomplished using the Augmented Likelihood Image Reconstruction algorithm.


Asunto(s)
Metales , Órganos en Riesgo/diagnóstico por imagen , Fantasmas de Imagen , Próstata/diagnóstico por imagen , Prótesis e Implantes , Interpretación de Imagen Radiográfica Asistida por Computador/normas , Planificación de la Radioterapia Asistida por Computador/normas , Algoritmos , Artefactos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Órganos en Riesgo/efectos de la radiación , Pelvis/diagnóstico por imagen , Pelvis/efectos de la radiación , Próstata/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Recto/diagnóstico por imagen , Recto/efectos de la radiación , Procesamiento de Señales Asistido por Computador/instrumentación , Tomografía Computarizada por Rayos X/métodos
2.
J Appl Clin Med Phys ; 18(1): 243-250, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28291909

RESUMEN

BACKGROUND: The quality of CT slices can be drastically reduced in the presence of high-density objects such as metal implants within the patients' body due to the occurrence of streaking artifacts. Consequently, a delineation of anatomical structures might not be possible, which strongly influences clinical examination. PURPOSE: The aim of the study is to clinically evaluate the retrieval of attenuation values and structures by the recently proposed Augmented Likelihood Image Reconstruction (ALIR) and linear interpolation in the presence of metal artifacts. MATERIAL AND METHODS: A commercially available phantom was equipped with two steel inserts. At a position between the metal rods, which shows severe streaking artifacts, different human tissue-equivalent inserts are alternately mounted. Using a single-source computer tomograph, raw data with and without metal rods are acquired for each insert. Images are reconstructed using the ALIR algorithm and a filtered back projection with and without linear interpolation. Mean and standard deviation are compared for a region of interest in the ALIR reconstructions, linear interpolation results, uncorrected images with metal rods, and the images without metal rods, which are used as a reference. Furthermore, the reconstructed shape of the inserts is analyzed by comparing different profiles of the image. RESULTS: The measured mean and standard deviation values show that for all tissue classes, the metal artifacts could be reduced using the ALIR algorithm and the linear interpolation. Furthermore, the HU values for the different classes could be retrieved with errors below the standard deviation in the reference image. An evaluation of the shape of the inserts shows that the reconstructed object fits the shape of the insert accurately after metal artifact correction. Moreover, the evaluation shows a drop in the standard deviation for the ALIR reconstructed images compared to the reference images while reducing artifacts and keeping the shape of the inserts, which indicates a noise reduction ability of the ALIR algorithm. CONCLUSION: HU values, which are distorted by metal artifacts, can be retrieved accurately with the ALIR algorithm and the linear interpolation approach. After metal artifact correction, structures, which are not perceptible in the original images due to streaking artifacts, are reconstructed correctly within the image using the ALIR algorithm. Furthermore, the ALIR produced images with a reduced noise level compared to reference images and artifact images. Linear interpolation results in a distortion of the investigated shapes and features remaining streaking artifacts.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Metales , Fantasmas de Imagen , Prótesis e Implantes , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Artefactos , Humanos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Procesamiento de Señales Asistido por Computador
3.
Int J Nanomedicine ; 19: 2137-2148, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38476277

RESUMEN

Purpose: Magnetic particle imaging (MPI) is an emerging medical imaging modality that is on the verge of clinical use. In recent years, cardiovascular applications have shown huge potential like, e.g., intraprocedural imaging guidance of stent placement through MPI. Due to the lack of signal generation, nano-modifications have been necessary to visualize commercial medical instruments until now. In this work, it is investigated if commercial interventional devices can be tracked with MPI without any nano-modification. Material and Methods: Potential MPI signal generation of nine endovascular metal stents was tested in a commercial MPI scanner. Two of the stents revealed sufficient MPI signal. Because one of the two stents showed relevant heating, the imaging experiments were carried out with a single stent model (Boston Scientific/Wallstent-Uni Endoprothesis, diameter: 16 mm, length: 60 mm). The nitinol stent and its delivery system were investigated in seven different scenarios. Therefore, the samples were placed at 49 defined spatial positions by a robot in a meandering pattern during MPI scans. Image reconstruction was performed, and the mean absolute errors (MAE) between the signals' centers of mass (COM) and ground truth positions were calculated. The stent material was investigated by magnetic particle spectroscopy (MPS) and vibrating sample magnetometry (VSM). To detect metallic components within the delivery system, nondestructive testing via computed tomography was performed. Results: The tracking of the stent and its delivery system was possible without any nano-modification. The MAE of the COM were 1.49 mm for the stent mounted on the delivery system, 3.70 mm for the expanded stent and 1.46 mm for the delivery system without the stent. The results of the MPS and VSM measurements indicate that besides material properties eddy currents seem to be responsible for signal generation. Conclusion: It is possible to image medical instruments with dedicated designs without modifications by means of MPI. This enables a variety of applications without compromising the mechanical and biocompatible properties of the instruments.


Asunto(s)
Stents , Tomografía Computarizada por Rayos X , Procesamiento de Imagen Asistido por Computador/métodos , Magnetismo , Fenómenos Magnéticos
4.
Nanotheranostics ; 8(2): 163-178, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38444740

RESUMEN

Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted thermometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object transfer from one system to another. Here, we present the design, development and evaluation process for integrable MFH platforms, which extends a commercial MPI scanner with the functionality of MFH. Methods: The biggest issue of integrating magnetic fluid hyperthermia platforms into a magnetic particle imaging system is the magnetic coupling of the devices, which induces high voltage in the imaging system, and is harming its components. In this paper, we use a self-compensation approach derived from heuristic algorithms to protect the magnetic particle imaging scanner. The integrable platforms are evaluated regarding electrical and magnetic characteristics, cooling capability, field strength, the magnetic coupling to a replica of the magnetic particle imaging system's main solenoid and particle heating. Results: The MFH platforms generate suitable magnetic fields for the magnetic heating of particles and are compatible with a commercial magnetic particle imaging scanner. In combination with the imaging system, selective heating with a gradient field and steerable heating positioning using the MPI focus fields are possible. Conclusion: The proposed MFH platforms serve as a therapeutic tool to unlock the MFH functionality of a commercial magnetic particle imaging scanner, enabling its use in future preclinical trials of MPI-guided, spatially selective magnetic hyperthermia therapy.


Asunto(s)
Hipertermia Inducida , Campos Magnéticos
5.
Magn Reson Med ; 69(6): 1761-7, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22829518

RESUMEN

Magnetic particle imaging has emerged as a new technique for the visualization and quantification of superparamagnetic iron oxide nanoparticles. It seems to be a very promising application for cardiovascular interventional radiology. A prerequisite for interventions is the artifact-free visualization of the required instruments and implants. Various commercially available catheters, guide wires, and a catheter experimentally coated with superparamagnetic iron oxide nanoparticles were tested regarding their signal characteristics using magnetic particle spectroscopy to evaluate their performance in magnetic particle imaging. The results indicate that signal-generating and non-signal-generating instruments can be distinguished. Furthermore, coating or loading non-signal-generating instruments with superparamagnetic iron oxide nanoparticles seems to be a promising approach, but optimized nanoparticles need yet to be developed.


Asunto(s)
Artefactos , Catéteres Cardíacos , Dextranos , Imagen por Resonancia Magnética Intervencional/instrumentación , Nanopartículas de Magnetita , Medios de Contraste , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Cardiovasc Intervent Radiol ; 46(3): 392-399, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36513764

RESUMEN

PURPOSE: Magnetic particle imaging (MPI) is a tomographic imaging modality with the potential for cardiovascular applications. In this context, the extent to which stents are heated should be estimated from safety perspective. Furthermore, the influence of the measurement parameters and stent distance to the isocenter of the MPI scanner on stent heating were evaluated. MATERIALS AND METHODS: Nine different endovascular stents and stent grafts were tested in polyvinyl-chloride tubes. The stents had diameters from 10 to 31 mm, lengths between 25 and 100 mm and were made from stainless steel, nitinol or cobalt-chromium. The temperature differences were recorded with fiber-optic thermometers. All measurements were performed in a preclinical commercial MPI scanner. The measurement parameters were varied (drive field strengths: 3, 6, 9, 12 mT and selection field gradients: 0, 1.25 and 2.5 T/m). Furthermore, measurements with different distances to the scanner's isocenter were performed (100 to 0 mm). RESULTS: All stents showed heating (maximum 53.1 K, minimum 4.6 K). The stent diameter directly correlated with the temperature increase. The drive field strength influenced the heating of the stents, whereas the selection field gradient had no detectable impact. The heating of the stents decreased with increasing distance from the scanner's isocenter and thus correlated with the loss of the scanner's magnetic field. CONCLUSION: Stents can cause potentially harmful heating in MPI. In addition to the stent diameter and design, the drive field strength and the distance to the MPI scanner's isocenter must be kept in mind as influencing parameters.


Asunto(s)
Procedimientos Endovasculares , Calefacción , Stents , Tomografía , Humanos , Fenómenos Magnéticos , Reparación Endovascular de Aneurismas
7.
Radiology ; 265(3): 933-8, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22996744

RESUMEN

PURPOSE: To evaluate the feasibility of different approaches of instrument visualization for cardiovascular interventions guided by using magnetic particle imaging (MPI). MATERIALS AND METHODS: Two balloon (percutaneous transluminal angioplasty) catheters were used. The balloon was filled either with diluted superparamagnetic iron oxide (SPIO) ferucarbotran (25 mmol of iron per liter) or with sodium chloride. Both catheters were inserted into a vessel phantom that was filled oppositional to the balloon content with sodium chloride or diluted SPIO (25 mmol of iron per liter). In addition, the administration of a 1.4-mL bolus of pure SPIO (500 mmol of iron per liter) followed by 5 mL of sodium chloride through a SPIO-labeled balloon catheter into the sodium chloride-filled vessel phantom was recorded. Images were recorded by using a preclinical MPI demonstrator. All images were acquired by using a field of view of 3.6 × 3.6 × 2.0 cm. RESULTS: By using MPI, both balloon catheters could be visualized with high temporal (21.54 msec per image) and sufficient spatial (≤ 3 mm) resolution without any motion artifacts. The movement through the field of view, the inflation and deflation of the balloon, and the application of the SPIO bolus were visualized at a rate of 46 three-dimensional data sets per second. CONCLUSION: Visualization of SPIO-labeled instruments for cardiovascular intervention at high temporal resolution as well as monitoring the application of a SPIO-based tracer by using labeled instruments is feasible. Further work is necessary to evaluate different labeling approaches for diagnostic catheters and guidewires and to demonstrate their navigation in the vascular system after administration of contrast material. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120424/-/DC1.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Medios de Contraste/administración & dosificación , Dextranos/administración & dosificación , Imagen por Resonancia Magnética/métodos , Nanopartículas de Magnetita/administración & dosificación , Artefactos , Medios de Contraste/química , Dextranos/química , Estudios de Factibilidad , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional , Nanopartículas de Magnetita/química , Fantasmas de Imagen , Cloruro de Polivinilo , Cloruro de Sodio/administración & dosificación , Cloruro de Sodio/química
8.
Med Phys ; 39(11): 7042-54, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23127095

RESUMEN

PURPOSE: In computed tomography imaging metal objects in the region of interest introduce inconsistencies during data acquisition. Reconstructing these data leads to an image in spatial domain including star-shaped or stripe-like artifacts. In order to enhance the quality of the resulting image the influence of the metal objects can be reduced. Here, a metal artifact reduction (MAR) approach is proposed that is based on a recomputation of the inconsistent projection data using a fully three-dimensional Fourier-based interpolation. The success of the projection space restoration depends sensitively on a sensible continuation of neighboring structures into the recomputed area. Fortunately, structural information of the entire data is inherently included in the Fourier space of the data. This can be used for a reasonable recomputation of the inconsistent projection data. METHODS: The key step of the proposed MAR strategy is the recomputation of the inconsistent projection data based on an interpolation using nonequispaced fast Fourier transforms (NFFT). The NFFT interpolation can be applied in arbitrary dimension. The approach overcomes the problem of adequate neighborhood definitions on irregular grids, since this is inherently given through the usage of higher dimensional Fourier transforms. Here, applications up to the third interpolation dimension are presented and validated. Furthermore, prior knowledge may be included by an appropriate damping of the transform during the interpolation step. This MAR method is applicable on each angular view of a detector row, on two-dimensional projection data as well as on three-dimensional projection data, e.g., a set of sequential acquisitions at different spatial positions, projection data of a spiral acquisition, or cone-beam projection data. RESULTS: Results of the novel MAR scheme based on one-, two-, and three-dimensional NFFT interpolations are presented. All results are compared in projection data space and spatial domain with the well-known one-dimensional linear interpolation strategy. CONCLUSIONS: In conclusion, it is recommended to include as much spatial information into the recomputation step as possible. This is realized by increasing the dimension of the NFFT. The resulting image quality can be enhanced considerably.


Asunto(s)
Artefactos , Imagenología Tridimensional/métodos , Metales , Tomografía Computarizada por Rayos X/métodos , Análisis de Fourier , Humanos , Fantasmas de Imagen
9.
Med Phys ; 39(7): 4444-59, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22830777

RESUMEN

PURPOSE: A novel unconditionally stable, explicit numerical method is introduced to the field of modeling brain cancer progression on a tissue level together with an inverse problem (IP) based on optimal control theory that allows for automated model calibration with respect to observations in clinical imaging data. METHODS: Biophysical models of cancer progression on a tissue level are in general based on the assumption that the spatiotemporal spread of cancerous cells is determined by cell division and net migration. These processes are typically described in terms of a parabolic partial differential equation (PDE). In the present work a parallelized implementation of an unconditionally stable, explicit Euler (EE(⋆)) time integration method for the solution of this PDE is detailed. The key idea of the discussed EE(⋆) method is to relax the strong stability requirement on the spectral radius of the coefficient matrix by introducing a subdivision regime for a given outer time step. The performance is related to common implicit numerical methods. To quantify the numerical error, a simplified model that has a closed form solution is considered. To allow for a systematic, phenomenological validation a novel approach for automated model calibration on the basis of observations in medical imaging data is developed. The resulting IP is based on optimal control theory and manifests as a large scale, PDE constrained optimization problem. RESULTS: The numerical error of the EE(⋆) method is at the order of standard implicit numerical methods. The computing times are well below those obtained for implicit methods and by that demonstrate efficiency. Qualitative and quantitative analysis in 12 patients demonstrates that the obtained results are in strong agreement with observations in medical imaging data. Rating simulation success in terms of the mean overlap between model predictions and manual expert segmentations yields a success rate of 75% (9 out of 12 patients). CONCLUSIONS: The discussed EE(⋆) method provides desirable features for image-based model calibration or hybrid image registration algorithms in which the model serves as a biophysical prior. This is due to (i) ease of implementation, (ii) low memory requirements, (iii) efficiency, (iv) a straightforward interface for parameter updates, and (v) the fact that the method is inherently matrix-free. The explicit time integration method is confirmed via experiments for automated model calibration. Qualitative and quantitative analysis demonstrates that the proposed framework allows for recovering observations in medical imaging data and by that phenomenological model validity.


Asunto(s)
Neoplasias Encefálicas/patología , Neoplasias Encefálicas/fisiopatología , Encéfalo/patología , Encéfalo/fisiopatología , Glioma/patología , Glioma/fisiopatología , Modelos Biológicos , Animales , Simulación por Computador , Humanos , Invasividad Neoplásica
10.
Nanomaterials (Basel) ; 12(10)2022 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-35630979

RESUMEN

The purpose of this work was to develop instrument markers that are visible in both magnetic particle imaging (MPI) and magnetic resonance imaging (MRI). The instrument markers were based on two different magnetic nanoparticle types (synthesized in-house KLB and commercial Bayoxide E8706). Coatings containing one of both particle types were fabricated and measured with a magnetic particle spectrometer (MPS) to estimate their MPI performance. Coatings based on both particle types were then applied on a segment of a nonmetallic guidewire. Imaging experiments were conducted using a commercial, preclinical MPI scanner and a preclinical 1 tesla MRI system. MPI image reconstruction was performed based on system matrices measured with dried KLB and Bayoxide E8706 coatings. The bimodal markers were clearly visible in both methods. They caused circular signal voids in MRI and areas of high signal intensity in MPI. Both the signal voids as well as the areas of high signal intensity were larger than the real marker size. Images that were reconstructed with a Bayoxide E8706 system matrix did not show sufficient MPI signal. Instrument markers with bimodal visibility are essential for the perspective of monitoring cardiovascular interventions with MPI/MRI hybrid systems.

11.
IEEE Trans Med Imaging ; 41(11): 3301-3308, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35709119

RESUMEN

Vascular interventions are a promising application of Magnetic Particle Imaging enabling a high spatial and temporal resolution without using ionizing radiation. The possibility to visualize the vessels as well as the devices, especially at the same time using multi-contrast approaches, enables a higher accuracy for diagnosis and treatment of vascular diseases. Different techniques to make devices MPI visible have been introduced so far, such as varnish markings or filling of balloons. However, all approaches include challenges for in vivo applications, such as the stability of the varnishing or the visibility of tracer filled balloons in deflated state. In this contribution, we present for the first time a balloon catheter that is molded from a granulate incorporating nanoparticles and can be visualized sufficiently in MPI. Computed tomography is used to show the homogeneous distribution of particles within the material. Safety measurements confirm that the incorporation of nanoparticles has no negative effect on the balloon. A dynamic experiment is performed to show that the inflation as well as deflation of the balloon can be imaged with MPI.


Asunto(s)
Diagnóstico por Imagen , Nanopartículas de Magnetita , Diagnóstico por Imagen/métodos , Catéteres , Fenómenos Magnéticos
12.
Radiologie (Heidelb) ; 62(6): 496-503, 2022 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-35925059

RESUMEN

BACKGROUND: Magnetic particle imaging offers far-reaching potential with a unique range of applications. OBJECTIVES: Identification of application scenarios with added value for clinical use. METHODS: Overview of previous application scenarios in phantom and small animal models, evaluation of dual-use potential. RESULTS: With its unique application profile, magnetic particle imaging offers a solution for clinical use where common, established imaging techniques reach their limits. As a tracer imaging technique, it is particularly characterized by its high speed, sensitivity and contrast-to-noise ratio. The low magnetic fields and low power consumption allow imaging to be mobile and taken to locations that were previously inaccessible. CONCLUSION: Magnetic particle imaging has seen rapid development in recent years. The applications demonstrated in the small animal model and phantom were able to support the versatility and added value of the method. With the availability of human imaging systems, the technology must face clinical verification studies.


Asunto(s)
Diagnóstico por Imagen , Campos Magnéticos , Animales , Humanos , Fantasmas de Imagen
13.
Med Phys ; 38(7): 4321-8, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21859033

RESUMEN

PURPOSE: In computed tomography (CT), metal objects in the region of interest introduce data inconsistencies during acquisition. Reconstructing these data results in an image with star shaped artifacts induced by the metal inconsistencies. To enhance image quality, the influence of the metal objects can be reduced by different metal artifact reduction (MAR) strategies. For an adequate evaluation of new MAR approaches a ground truth reference data set is needed. In technical evaluations, where phantoms can be measured with and without metal inserts, ground truth data can easily be obtained by a second reference data acquisition. Obviously, this is not possible for clinical data. Here, an alternative evaluation method is presented without the need of an additionally acquired reference data set. METHODS: The proposed metric is based on an inherent ground truth for metal artifacts as well as MAR methods comparison, where no reference information in terms of a second acquisition is needed. The method is based on the forward projection of a reconstructed image, which is compared to the actually measured projection data. RESULTS: The new evaluation technique is performed on phantom and on clinical CT data with and without MAR. The metric results are then compared with methods using a reference data set as well as an expert-based classification. It is shown that the new approach is an adequate quantification technique for artifact strength in reconstructed metal or MAR CT images. CONCLUSIONS: The presented method works solely on the original projection data itself, which yields some advantages compared to distance measures in image domain using two data sets. Beside this, no parameters have to be manually chosen. The new metric is a useful evaluation alternative when no reference data are available.


Asunto(s)
Algoritmos , Artefactos , Metales , Prótesis e Implantes , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Alemania , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/normas
14.
Med Phys ; 38(9): 5200-7, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21978064

RESUMEN

PURPOSE: The concept of a magnetic field-free line (FFL), with regard to the novel tomographic modality magnetic particle imaging (MPI), was recently introduced. Theoretical approaches predict the improvement of sensitivity of MPI by a factor of ten replacing the conventionally used field-free point (FFP) by a FFL. In this work, an experimental apparatus for generating an arbitrarily rotated and translated FFL field is described and tested. METHODS: A theoretical motivation for the implemented setup is provided and the required currents are derived in dependency of the coil sensitivities. A prototype of a FFL field generator is manufactured and the fields are measured using a Hall effect sensor. An evaluation of the generated fields is performed via comparison to simulated data. RESULTS: To utilize the FFL concept for MPI, the setup generating the fields needs to be feasible in praxis with respect to power loss. Furthermore, rotating and translating the FFL, while keeping the setup static in space, is a crucial aspect for conveying FFL imaging to clinical applications. The implemented setup copes with both of these challenges and allows for experimental generation as well as evaluation of the required fields. The generated fields agree to within 3.5% of model predictions. CONCLUSIONS: This work transfers the FFL concept from theoretical considerations to the implementation of an experimental setup generating the required fields. The high agreement of the measured fields with simulated data indicates the feasibility of magnetic field generation for the implementation of FFL imaging in MPI.


Asunto(s)
Magnetismo , Rotación , Tomografía/instrumentación
15.
Int J Nanomedicine ; 16: 213-221, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33469281

RESUMEN

PURPOSE: Endovascular stents are medical devices, which are implanted in stenosed blood vessels to ensure sufficient blood flow. Due to a high rate of in-stent re-stenoses, there is the need of a noninvasive imaging method for the early detection of stent occlusion. The evaluation of the stent lumen with computed tomography (CT) and magnetic resonance imaging (MRI) is limited by material-induced artifacts. The purpose of this work is to investigate the potential of the tracer-based modality magnetic particle imaging (MPI) for stent lumen visualization and quantification. METHODS: In this in vitro study, 21 endovascular stents were investigated in a preclinical MPI scanner. Therefore, the stents were implanted in vessel phantoms. For the signal analysis, the phantoms were scanned without tracer material, and the signal-to-noise-ratio was analyzed. For the evaluation of potential artifacts and the lumen quantification, the phantoms were filled with diluted tracer agent. To calculate the stent lumen diameter a calibrated threshold value was applied. RESULTS: We can show that it is possible to visualize the lumen of a variety of endovascular stents without material induced artifacts, as the stents do not generate sufficient signals in MPI. The stent lumen quantification showed a direct correlation between the calculated and nominal diameter (r = 0.98). CONCLUSION: In contrast to MRI and CT, MPI is able to visualize and quantify stent lumina very accurately.


Asunto(s)
Procedimientos Endovasculares , Fenómenos Magnéticos , Procesamiento de Señales Asistido por Computador , Stents , Artefactos , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Relación Señal-Ruido , Tomografía Computarizada por Rayos X
16.
Sci Rep ; 11(1): 14082, 2021 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-34234207

RESUMEN

Cerebral aneurysms are potentially life threatening and nowadays treated by a catheter-guided coiling or by a neurosurgical clipping intervention. Here, we propose a helically shaped magnetic micro-robot, which can be steered by magnetic fields in an untethered manner and could be applied for a novel coiling procedure. This is shown by navigating the micro-robot through an additively manufactured phantom of a human cerebral aneurysm. The magnetic fields are applied with a magnetic particle imaging (MPI) scanner, which allows for the navigation and tomographic visualization by the same machine. With MPI the actuation process can be visualized with a localization accuracy of 0.68 mm and an angiogram can be acquired both without any radiation exposure. First in-vitro phantom experiments are presented, showing an idea of a robot conducted treatment of cerebral aneurysms.


Asunto(s)
Diagnóstico por Imagen/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Fantasmas de Imagen , Procedimientos Quirúrgicos Robotizados , Humanos , Hipertermia Inducida , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Procedimientos Quirúrgicos Robotizados/métodos , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
17.
Cardiovasc Intervent Radiol ; 44(7): 1109-1115, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33723668

RESUMEN

PURPOSE: To evaluate heating of a redilatable stent for the treatment of aortic coarctation in neonates and small children in the new imaging modality magnetic particle imaging and established magnetic resonance imaging. MATERIALS AND METHODS: The cobalt-chromium stent (BabyStent, OSYPKA AG, Rheinfelden, Germany) has a stent design which allows for redilatation and adjustment of the diameter from 6 to 16 mm for a use in aortic coarctation. The stent loses its radial integrity while opening at predetermined breaking points at a diameter of 14 mm or 16 mm, respectively. We measured the temperature increase in the stent at different diameters during 7-min magnetic particle imaging and magnetic resonance imaging scans with fiber optic thermometers under static conditions surrounded by air. In magnetic particle imaging, stents with diameters from 6 to 16 mm were tested while in magnetic resonance imaging only stents with diameters of 6 mm and 14 mm were investigated exemplarily. RESULT: In magnetic particle imaging, the measured temperature differences increased up to 4.7 K with growing diameters, whereas the opened stents with discontinuous struts at 14 and 16 mm showed only minimal heating of max. 0.5 K. In contrast to magnetic particle imaging, our measurements showed no heating of the stents during magnetic resonance imaging under identical conditions. CONCLUSION: The BabyStent did show only slight heating in magnetic particle imaging and no detectable temperature increase in magnetic resonance imaging.


Asunto(s)
Coartación Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Calefacción/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Stents , Coartación Aórtica/diagnóstico , Humanos , Resultado del Tratamiento
18.
Med Phys ; 37(7): 3538-40, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20831060

RESUMEN

PURPOSE: Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was introduced. The purpose of this article is to improve the efficiency of the FFL coil geometry even further. METHODS: In order to reduce the electrical power loss of the setup, an additional Maxwell coil pair is introduced that is tailored to generate the static part of the FFL field. RESULTS: Using the proposed coil assembly, the electrical power loss for the generation of a rotating FFL is considerably reduced compared to previously known coil setups. Furthermore, the quality of the generated FFL is significantly increased. CONCLUSIONS: The proposed coil assembly is almost as efficient as an equivalent FFP scanner. Furthermore, the assembly cannot only be used for FFL imaging but for FFP imaging as well. Hence, the findings of this article denote an important step toward the first practical implementation of the FFL coil geometry.


Asunto(s)
Magnetismo/instrumentación , Estudios de Factibilidad
19.
Med Phys ; 37(2): 485-91, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20229857

RESUMEN

PURPOSE: Magnetic particle imaging (MPI) is a new quantitative imaging technique capable of determining the spatial distribution of superparamagnetic nanoparticles at high temporal and spatial resolution. For reconstructing this spatial distribution, the particle dynamics and the scanner properties have to be known. To date, they are obtained in a tedious calibration procedure by measuring the magnetization response of a small delta sample shifted through the measuring field. Recently, first reconstruction results using a 1D model-based system function were published, showing comparable image quality as obtained with a measured system function. In this work, first 2D model-based reconstruction results of measured MPI data are presented. METHODS: To simulate the system function, various parameters have to be modeled, namely, the magnetic field, the particle magnetization, the voltage induced in the receive coils, and the transfer function of the receive chain. To study the accuracy of the model-based approach, 2D MPI data are measured and reconstructed with modeled and measured system functions. RESULTS: It is found that the model-based system function is sufficiently accurate to allow for reconstructing experimental data. The resulting image quality is close to that obtained with a measurement-based reconstruction. CONCLUSIONS: The model-based system function approach addresses a major drawback of the measurement-based procedure, namely, the long acquisition time. In this work, the acquisition of the measurement-based system function took 45 min, while the model-based system function was obtained in only 15 s. For 3D data, where the acquisition of the measurement-based system function takes more than 6 h, the need for an efficient system function generation is even more obvious.


Asunto(s)
Medios de Contraste/química , Óxido Ferrosoférrico/química , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Modelos Químicos , Simulación por Computador , Medios de Contraste/efectos de la radiación , Campos Electromagnéticos , Óxido Ferrosoférrico/efectos de la radiación , Magnetismo/métodos
20.
Sci Rep ; 10(1): 18432, 2020 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-33116183

RESUMEN

Image reconstruction in magnetic particle imaging is often performed using a system matrix based approach. The acquisition of a system matrix is a time-consuming calibration which may take several weeks and thus, is not feasible for a clinical device. Due to hardware characteristics of the receive chain, a system matrix may not even be used in similar devices but has to be acquired for each imager. In this work, a dedicated device is used for measuring a hybrid system matrix. It is shown that the measurement time of a 3D system matrix is reduced by 96%. The transfer function of the receive chains is measured, which allows the use of the same system matrix in multiple devices. Equivalent image reconstruction results are reached using the hybrid system matrix. Furthermore, the inhomogeneous sensitivity profile of receive coils is successfully applied to a hybrid system matrix. It is shown that each aspect of signal acquisition in magnetic particle imaging can be taken into account using hybrid system matrices. It is favourable to use a hybrid system matrix for image reconstruction in terms of measurement time, signal-to-noise ratio and discretisation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA