Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Card Fail ; 29(4): 463-472, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36243338

RESUMEN

BACKGROUND: Congestion is central to the pathophysiology of heart failure (HF); thus, tracking congestion is crucial for the management of patients with HF. In this study we aimed to compare changes in inferior vena cava diameter (IVCD) with venous pressure following manipulation of volume status during ultrafiltration in patients with cardiac dysfunction. METHODS AND RESULTS: Patients with stable hemodialysis and with systolic or diastolic dysfunction were studied. Central venous pressure (CVP) and peripheral venous pressure (PVP) were measured before and after hemodialysis. IVCD and PVP were measured simultaneously just before dialysis, 3 times during dialysis and immediately after dialysis. Changes in IVCD and PVP were compared at each timepoint with ultrafiltration volumes. We analyzed 30 hemodialysis sessions from 20 patients. PVP was validated as a surrogate for CVP. Mean ultrafiltration volume was 2102 ± 667 mL. IVCD discriminated better ultrafiltration volumes ≤ 500 mL or ≤ 750 mL than PVP (AUC 0.80 vs 0.62, and 0.80 vs 0.56, respectively; both P< 0.01). IVCD appeared to track better ultrafiltration volume (P< 0.01) and hemoconcentration (P< 0.05) than PVP. Changes in IVCD were of greater magnitude than those of PVP (average change from predialysis: -58 ± 30% vs -28 ± 21%; P< 0.001). CONCLUSIONS: In patients undergoing ultrafiltration, changes in IVCD tracked changes in volume status better than venous pressure.


Asunto(s)
Cardiopatías , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Vena Cava Inferior/diagnóstico por imagen , Presión Venosa Central/fisiología , Diálisis Renal , Presión Venosa
2.
Echocardiography ; 39(4): 637-642, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35277896

RESUMEN

A 56-year-old patient with rheumatic heart disease and atrial fibrillation underwent mitral valve replacement with a mechanical prosthesis. The 3D perioperative echocardiogram showed an intermittent immobile medial disk without hemodynamic repercussion in the intensive care unit. The patient was taken back to the operating room and surgeons could not identify the cause. An enlarged left atrium and the size of the prosthetic valve was thought to have precipitated this condition. The heart team decided a biological prosthetic valve replacement would be performed. This case emphasizes the important role of the perioperative 3D echocardiogram in the detection of immediate surgical complications.


Asunto(s)
Ecocardiografía Tridimensional , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Cardiopatía Reumática , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/etiología , Estenosis de la Válvula Mitral/cirugía , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA