Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
AJR Am J Roentgenol ; 222(5): e2330769, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38415578

RESUMEN

BACKGROUND. CT with adrenal-washout protocol (hereafter, adrenal-protocol CT) is commonly performed to distinguish adrenal adenomas from other adrenal tumors. However, the technique's utility among heterogeneous nodules is not well established, and the optimal method for placing ROIs in heterogeneous nodules is not clearly defined. OBJECTIVE. The purpose of our study was to determine the diagnostic performance of adrenal-protocol CT to distinguish adenomas from nonadenomas among heterogeneous adrenal nodules and to compare this performance among different methods for ROI placement. METHODS. This retrospective study included 164 patients (mean age, 59.1 years; 61 men, 103 women) with a total of 164 heterogeneous adrenal nodules evaluated using adrenal-protocol CT at seven institutions. All nodules had an available pathologic reference standard. A single investigator at each institution evaluated the CT images. ROIs were placed on portal venous phase images using four ROI methods: standard ROI, which refers to a single large ROI in the nodule's center; high ROI, a single ROI on the nodule's highest-attenuation area; low ROI, a single ROI the on nodule's lowest-attenuation area; and average ROI, the mean of the three ROIs on the nodule's superior, middle, and inferior thirds using the approach for the standard ROI. ROIs were then placed in identical locations on unenhanced and delayed phase images. Absolute washout was determined for all methods. RESULTS. The nodules comprised 82 adenomas and 82 nonadenomas (36 pheochromocytomas, 20 metastases, 12 adrenocortical carcinomas, and 14 nodules with other pathologies). The mean nodule size was 4.5 ± 2.8 (SD) cm (range, 1.6-23.0 cm). Unenhanced CT attenuation of 10 HU or less exhibited sensitivity and specificity for adenoma of 22.0% and 96.3% for standard-ROI, 11.0% and 98.8% for high-ROI, 58.5% and 84.1% for low-ROI, and 30.5% and 97.6% for average-ROI methods. Adrenal-protocol CT overall (unenhanced attenuation ≤ 10 HU or absolute washout of ≥ 60%) exhibited sensitivity and specificity for adenoma of 57.3% and 84.1% for the standard-ROI method, 63.4% and 51.2% for the high-ROI method, 68.3% and 62.2% for the low-ROI method, and 59.8% and 85.4% for the average-ROI method. CONCLUSION. Adrenal-protocol CT has poor diagnostic performance for distinguishing adenomas from nonadenomas among heterogeneous adrenal nodules regardless of the method used for ROI placement. CLINICAL IMPACT. Adrenal-protocol CT has limited utility in the evaluation of heterogeneous adrenal nodules.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Persona de Mediana Edad , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Diagnóstico Diferencial , Sensibilidad y Especificidad , Anciano , Adulto , Medios de Contraste , Adenoma/diagnóstico por imagen , Anciano de 80 o más Años
2.
Rev Endocr Metab Disord ; 24(1): 97-106, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35624403

RESUMEN

A high level of clinical suspicion is essential in the diagnosis and management of a suspected adrenal mass during pregnancy and the peripartum period. Timely recognition is important in order to improve fetal and maternal outcomes. Imaging is often performed to confirm a suspected adrenal lesion; however, increasing usage of diagnostic imaging during pregnancy and lactation has also increased awareness, concerns and confusion regarding the safety risks regarding fetal and maternal exposure to radiation and imaging intravenous contrast agents. This may lead to anxiety and avoidance of imaging examinations which can delay diagnosis and appropriate treatment. This article briefly reviews evidence-based recommended imaging modalities during pregnancy and the lactation period for the assessment of a suspected adrenal mass while recognizing that no examination should be withheld when the exam is necessary to confirm an important clinical suspicion. The imaging characteristics of the more common adrenal pathologies that may affect pregnant women are also discussed.


Asunto(s)
Lactancia , Complicaciones del Embarazo , Humanos , Embarazo , Femenino , Complicaciones del Embarazo/diagnóstico por imagen , Feto , Diagnóstico por Imagen/métodos
3.
AJR Am J Roentgenol ; 220(1): 86-94, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35920707

RESUMEN

BACKGROUND. Homogeneous microscopic fat within adrenal nodules on chemical-shift MRI (CS-MRI) is diagnostic of benign adrenal adenoma, but the clinical relevance of heterogeneous microscopic fat is not well established. OBJECTIVE. This study sought to determine the prevalence of malignancy in adrenal nodules with heterogeneous microscopic fat on dual-echo T1-weighted CS-MRI. METHODS. We performed a retrospective study of adult patients with adrenal nodules detected on MRI performed between August 2007 and November 2020 at seven institutions. Eligible nodules had a short-axis diameter of 10 mm or larger with heterogeneous microscopic fat (defined by an area of signal loss of < 80% on opposed-phase CS-MRI). Two radiologists from each center, blinded to reference standard results, determined the signal loss pattern (diffuse, two distinct parts, speckling pattern, central loss, or peripheral loss) within the nodules. The reference standard used was available for 283 nodules (pathology for 21 nodules, ≥ 1 year of imaging follow-up for 245, and ≥ 5 years of clinical follow-up for 17) in 282 patients (171 women and 111 men; mean age, 60 ± 12 [SD] years); 30% (86/282) patients had prior malignancy. RESULTS. The mean long-axis diameter was 18.7 ± 7.9 mm (range, 10-80 mm). No malignant nodules were found in patients without prior cancer (0/197; 95% CI, 0-1.5%). Four of the 86 patients with prior malignancy (hepatocellular carcinoma [HCC], renal cell carcinoma [RCC], lung cancer, or both colon cancer and RCC) (4.7%; 95% CI, 1.3-11.5%) had metastatic nodules. Detected patterns were diffuse heterogeneous signal loss (40% [114/283]), speckling (28% [80/283]), two distinct parts (18% [51/283]), central loss (9% [26/283]), and peripheral loss (4% [12/283]). Two metastases from HCC and RCC showed diffuse heterogeneous signal loss. Lung cancer metastasis manifested as two distinct parts, and the metastasis in the patient with both colon cancer and RCC showed peripheral signal loss. CONCLUSION. Presence of heterogeneous microscopic fat in adrenal nodules on CS-MRI indicates a high likelihood of benignancy, particularly in patients without prior cancer. This finding is also commonly benign in patients with cancer; however, caution is warranted when primary malignancies may contain fat or if the morphologic pattern of signal loss may indicate a collision tumor. CLINICAL IMPACT. In the absence of prior cancer, adrenal nodules with heterogeneous microscopic fat do not require additional imaging evaluation.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Carcinoma Hepatocelular , Carcinoma de Células Renales , Neoplasias del Colon , Neoplasias Renales , Neoplasias Hepáticas , Neoplasias Pulmonares , Adulto , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Carcinoma de Células Renales/patología , Estudios Retrospectivos , Prevalencia , Imagen por Resonancia Magnética/métodos , Diagnóstico Diferencial , Neoplasias Renales/patología , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen
4.
Radiographics ; 43(7): e220191, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37347698

RESUMEN

The radiologic diagnosis of adrenal disease can be challenging in settings of atypical presentations, mimics of benign and malignant adrenal masses, and rare adrenal anomalies. Misdiagnosis may lead to suboptimal management and adverse outcomes. Adrenal adenoma is the most common benign adrenal tumor that arises from the cortex, whereas adrenocortical carcinoma (ACC) is a rare malignant tumor of the cortex. Adrenal cyst and myelolipoma are other benign adrenal lesions and are characterized by their fluid and fat content, respectively. Pheochromocytoma is a rare neuroendocrine tumor of the adrenal medulla. Metastases to the adrenal glands are the most common malignant adrenal tumors. While many of these masses have classic imaging appearances, considerable overlap exists between benign and malignant lesions and can pose a diagnostic challenge. Atypical adrenal adenomas include those that are lipid poor; contain macroscopic fat, hemorrhage, and/or iron; are heterogeneous and/or large; and demonstrate growth. Heterogeneous adrenal adenomas may mimic ACC, metastasis, or pheochromocytoma, particularly when they are 4 cm or larger, whereas smaller versions of ACC, metastasis, and pheochromocytoma and those with washout greater than 60% may mimic adenoma. Because of its nonenhanced CT attenuation of less than or equal to 10 HU, a lipid-rich adrenal adenoma may be mimicked by a benign adrenal cyst, or it may be mimicked by a tumor with central cystic and/or necrotic change such as ACC, pheochromocytoma, or metastasis. Rare adrenal tumors such as hemangioma, ganglioneuroma, and oncocytoma also may mimic adrenal adenoma, ACC, metastasis, and pheochromocytoma. The authors describe cases of adrenal neoplasms that they have encountered in clinical practice and presented to adrenal multidisciplinary tumor boards. Key lessons to aid in diagnosis and further guide appropriate management are provided. © RSNA, 2023 Online supplemental material is available for this article. Quiz questions for this article are available through the Online Learning Center.


Asunto(s)
Adenoma , Neoplasias de la Corteza Suprarrenal , Neoplasias de las Glándulas Suprarrenales , Carcinoma Corticosuprarrenal , Quistes , Feocromocitoma , Humanos , Feocromocitoma/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Carcinoma Corticosuprarrenal/diagnóstico por imagen , Quistes/patología , Lípidos
5.
Radiology ; 303(1): 99-109, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35040671

RESUMEN

Background Urinary continence after radical prostatectomy (RP) is an important determinant of patient quality of life. Anatomic measures at prostate MRI have been previously associated with continence outcomes, but their predictive ability and interrater agreement are unclear in comprehensive clinical models. Purpose To evaluate the predictive ability and interrater agreement of MRI-based anatomic measurements of post-RP continence when combined with clinical multivariable models. Materials and Methods In this retrospective cohort study, continence outcomes were evaluated in men who underwent RP from August 2015 to October 2019. Preoperative MRI-based anatomic measures were obtained retrospectively by four abdominal radiologists. Before participation, these radiologists completed measure-specific training. Logistic regression models were developed with clinical variables alone, MRI variables alone, and combined variables for predicting continence at 3, 6, and 12 months after RP; some patient data were missing at each time point. Interrater agreement of MRI variables was assessed by using intraclass correlation coefficients (ICCs). Results A total of 586 men were included (mean age ± standard deviation: 63 years ± 7). The proportion of patients with incontinence was 0.2% (one of 589) at baseline, 27% (145 of 529) at 3 months, 14% (63 of 465) at 6 months, and 9% (37 of 425) at 12 months. Longer coronal membranous urethra length (MUL) improved the odds of post-RP continence at all time points (odds ratio per 1 mm: 0.86 [95% CI: 0.80, 0.93], P < .001; 0.86 [95% CI: 0.78, 0.95], P = .003; and 0.79 [95% CI: 0.67, 0.91], P = .002, respectively) in models that incorporated both clinical and MRI predictors. No other MRI variables were predictive. Age and baseline urinary function score were the only other predictive clinical variables at every time point. Interrater agreement was moderate (ICC, 0.62) for MUL among readers with measure-specific prostate MRI training and poor among those without the training (ICC, 0.38). Conclusion Preoperative MRI-measured coronal membranous urethra length was an independent predictor of urinary continence after prostatectomy. © RSNA, 2022 Online supplemental material is available for this article.


Asunto(s)
Próstata , Neoplasias de la Próstata , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Próstata/cirugía , Prostatectomía/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Calidad de Vida , Recuperación de la Función , Estudios Retrospectivos
6.
AJR Am J Roentgenol ; 219(5): 804-812, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35731098

RESUMEN

BACKGROUND. Washout CT is commonly used to evaluate indeterminate adrenal nodules, although its diagnostic performance is poorly established in true adrenal incidentalomas. OBJECTIVE. The purpose of this study was to compare, in patients without a known malignancy history, the prevalence of malignancy for incidental adrenal nodules with unenhanced attenuation more than 10 HU that do and do not show absolute washout of 60% or more, thereby determining the diagnostic performance of washout CT for differentiating benign from malignant incidental adrenal nodules. METHODS. This retrospective six-institution study included 299 patients (mean age, 57.3 years; 180 women, 119 men) without known malignancy or suspicion for functioning adrenal tumor who underwent washout CT, which showed a total of 336 adrenal nodules with a short-axis diameter of 1 cm or more, homogeneity, and unenhanced attenuation over 10 HU. The date of the first CT ranged across institutions from November 1, 2003, to January 1, 2017. Washout was determined for all nodules. Reference standard was pathology (n = 54), imaging follow-up (≥ 1 year) (n = 269), or clinical follow-up (≥ 5 years) (n = 13). RESULTS. Prevalence of malignancy among all nodules, nodules less than 4 cm, and nodules 4 cm or more was 1.5% (5/336; 95% CI, 0.5-3.4%), 0.3% (1/317; 95% CI, 0.0-1.7%), and 21.1% (4/19; 95% CI, 6.1-45.6%), respectively. Prevalence of malignancy was not significantly different for nodules smaller than 4 cm with (0% [0/241]; 95% CI, 0.0-1.2%) and without (1.3% [1/76]; 95% CI, 0.0-7.1%) washout of 60% or more (p = .08) or for nodules 4 cm or larger with (16.7% [1/6]; 95% CI, 0.4-64.1%) and without (23.1% [3/13]; 95% CI, 5.0-53.8%) washout of 60% or more (p = .75). Washout of 60% or more was observed in 75.5% (243/322; 95% CI, 70.4-80.1%) of benign nodules (excluding pheochromocytomas), 20.0% (1/5; 95% CI, 0.5-71.6%) of malignant nodules, and 33.3% (3/9; 95% CI, 7.5-70.1%) of pheochromocytomas. For differentiating benign nodules from malignant nodules and pheochromocytomas, washout of 60% or more had 77.5% sensitivity, 70.0% specificity, 98.8% PPV, and 9.2% NPV among nodules smaller than 4 cm. CONCLUSION. Prevalence of malignancy is low among incidental homogeneous adrenal nodules smaller than 4 cm with unenhanced attenuation more than 10 HU and does not significantly differ between those with and without washout of 60% or more; wash-out of 60% or more has suboptimal performance for characterizing nodules as benign. CLINICAL IMPACT. Washout CT has limited utility in evaluating incidental adrenal nodules in patients without known malignancy.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Feocromocitoma , Masculino , Humanos , Femenino , Persona de Mediana Edad , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/epidemiología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Prevalencia
7.
Eur Radiol ; 31(8): 5490-5497, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33492471

RESUMEN

OBJECTIVE: To evaluate the effect of intravenous iodinated contrast on estimated glomerular filtration rate (eGFR) when administered immediately after thermal ablation of clinically localized T1a (cT1a) renal cell carcinoma (RCC). METHODS: This HIPAA-compliant, dual-center retrospective study was performed under a waiver of informed consent. Three hundred forty-two consecutive patients with cT1a biopsy-proven RCC were treated with percutaneous ablation between January 2010 and December 2017. Immediate post-ablation contrast-enhanced CT was the routine standard of care at one institution (contrast group), but not the other (control group). One-month pre- and 6-month post-ablation eGFR were compared using the Wilcoxon signed-rank test or the Kruskal-Wallis test. Multivariate linear regression was used to determine the effect of contrast on eGFR. A 1:1 propensity score matching was performed for all patients with a logistic model using patient, tumor, and procedural covariates. RESULTS: In total, 246 patients (158 M; median age 69 years, IQR 62-74) were included. Median tumor diameter (2.4 vs 2.5, p = 0.23) and RENAL nephrometry scores (6 vs 6, p = 0.92), surrogates for ablation zone size, were similar. Baseline kidney function was similar for the control and contrast groups, respectively (median eGFR: 70 vs 74 mL/min/1.73 m2, p = 0.29). There was an expected mild decline in eGFR after ablation (control: 70 vs 60 mL/min/1.73 m2, p < 0.001; contrast: 75 vs 71 mL/min/1.73 m2, p = 0.001). Intravenous iodinated contrast was not associated with a decline in eGFR on multivariate linear regression (1.91, 95% CI - 3.43-7.24, p = 0.46) or 1:1 propensity score-matched model (- 0.33, 95% CI - 6.81-6.15, p = 0.92). CONCLUSION: Intravenous iodinated contrast administered during ablation of cT1a RCC has no effect on eGFR. KEY POINTS: • Intravenous iodinated contrast administered during thermal ablation of clinically localized T1a renal cell carcinoma has no effect on kidney function. • Thermal ablation of clinically localized T1a renal cell carcinoma results in a mild decline in kidney function. • A decline in kidney function is similar for radiofrequency and microwave ablation of clinically localized T1a renal cell carcinoma.


Asunto(s)
Carcinoma de Células Renales , Ablación por Catéter , Neoplasias Renales , Anciano , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/cirugía , Medios de Contraste , Tasa de Filtración Glomerular , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Microondas , Estudios Retrospectivos , Resultado del Tratamiento
8.
Oncologist ; 25(9): 765-771, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32329106

RESUMEN

BACKGROUND: Controversy exists over whether there has been a true increase in the occurrence of thyroid cancer or overdiagnosis secondary to imaging practices. Because cancer overdiagnosis is associated with detection of indolent disease, overdiagnosis can be associated with perceived improvement in survival. MATERIALS AND METHODS: Surveillance, Epidemiology, and End Results-Medicare linked database was used to determine the relationship between type of imaging leading to thyroid cancer diagnosis and survival. Disease-specific and overall survival were evaluated in 11,945 patients aged ≥66 years with differentiated thyroid cancer diagnosed between January 1, 2001, and September 30, 2015, who prior to their cancer diagnosis initially underwent thyroid ultrasound versus other imaging capturing the neck. Analyses were performed using the Kaplan-Meier method and Cox proportional hazards model with propensity score. RESULTS: Patients who underwent thyroid ultrasound as compared with other imaging had improved disease-specific and overall survival (p < .001, p < .001). However, those who underwent thyroid ultrasound were less likely to have comorbidities (p < .001) and more likely to be younger (p < .001), be female (p < .001), have localized cancer (p < .001), and have tumor size ≤1 cm (p < .001). After using propensity score analysis and adjusting for tumor characteristics, type of initial imaging still correlated with better overall survival but no longer correlated with better disease-specific survival. CONCLUSION: There is improved disease-specific survival in patients diagnosed with thyroid cancer after thyroid ultrasound as compared with after other imaging. However, better disease-specific survival is related to these patients being younger and healthier and having lower-risk cancer, suggesting that thyroid ultrasound screening contributes to cancer overdiagnosis. IMPLICATIONS FOR PRACTICE: The findings from this study have implications for patients, physicians, and policy makers. Patients who have thyroid ultrasound as their initial imaging are fundamentally different from those who are diagnosed after other imaging. Because patients undergoing ultrasound are younger and healthier and are diagnosed with lower-risk thyroid cancer, they are less likely to die of their thyroid cancer. However, being diagnosed with thyroid cancer can lead to cancer-related worry and create risks for harm from treatments. Thus, efforts are needed to reduce inappropriate use of ultrasound, abide by the U.S. Preventive Services Task Force recommendations, and apply nodule risk stratification tools when appropriate.


Asunto(s)
Medicare , Neoplasias de la Tiroides , Anciano , Femenino , Humanos , Modelos de Riesgos Proporcionales , Neoplasias de la Tiroides/diagnóstico por imagen , Ultrasonografía , Estados Unidos/epidemiología
9.
AJR Am J Roentgenol ; 214(4): 900-906, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32069084

RESUMEN

OBJECTIVE. The objective of our study was to compare diagnostic accuracy and reliability of the 2017 American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) and 2015 American Thyroid Association (ATA) classifications for thyroid nodules. MATERIALS AND METHODS. This study was a retrospective cohort study of 1947 consecutive thyroid nodules sampled with fine-needle aspiration (FNA) from 2007 to 2016. Reviewers assigned TI-RADS scores to all nodules while blinded to clinical outcome and histologic diagnosis and compared TI-RADS scores with nodule-specific ATA scores from the same cohort. Five blinded radiologists independently assigned TI-RADS scores to a subset of 151 nodules (interrater agreement). The primary outcome was a comparison of the diagnostic accuracy of the TI-RADS and ATA classifications using ROC curve analysis. The reference standard was cytopathologic diagnosis according to the Bethesda system. Interrater agreement was determined using intraclass correlation (ICC) and kappa statistics. RESULTS. Of 1947 sampled thyroid nodules, 31.8% (n = 620) met TI-RADS criteria for FNA, 28.0% (n = 545) met TI-RADS criteria for follow-up, and 40.2% (n = 782) met TIRADS criteria to be ignored. Applying the 2015 ATA criteria resulted in recommendations of immediate FNA procedures for more nodules than applying the 2017 TI-RADS (ATA vs TIRADS: 62.3% [1213/1947] vs 31.8% [620/1947], p < 0.0001). Diagnostic accuracies (AUCs: TI-RADS score, 0.684 [95% CI, 0.644-0.724]; ATA, 0.686 [95% CI, 0.646-0.725]) and false-negative rates (TI-RADS, 2.2% [43/1947]; ATA, 2.4% [47/1947]) for the two classifications were similar (p = 0.75). Overall interrater agreement was fair for both (ICCs: TI-RADS, 0.437 [95% CI, 0.357-0.520]; ATA classification, 0.460 [95% CI, 0.391-0.533]). CONCLUSION. The 2017 ACR TI-RADS and 2015 ATA classifications have similar diagnostic accuracies and interrater agreement, but TI-RADS results in fewer nodules being recommended for immediate FNAs and more nodules being recommended for imaging surveillance.


Asunto(s)
Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía/métodos , Biopsia con Aguja Fina , Reacciones Falso Negativas , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Estudios Retrospectivos , Sensibilidad y Especificidad , Sociedades Médicas , Estados Unidos
11.
J Urol ; 195(3): 574-80, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26523883

RESUMEN

PURPOSE: A previously published risk stratification algorithm based on renal mass biopsy and radiographic mass size was useful to designate surveillance vs the need for immediate treatment of small renal masses. Nonetheless, there were some incorrect assignments, most notably when renal mass biopsy indicated low risk malignancy but final pathology revealed high risk malignancy. We studied other factors that might improve the accuracy of this algorithm. MATERIALS AND METHODS: For 202 clinically localized small renal masses in a total of 200 patients with available R.E.N.A.L. (radius, exophytic/endophytic, nearness of tumor to collecting system or sinus, anterior/posterior, hilar tumor touching main renal artery or vein and location relative to polar lines) nephrometry score, preoperative renal mass biopsy and final pathology we assessed the accuracy of management assignment (surveillance vs treatment) based on the previously published risk stratification algorithm as confirmed by final pathology. Logistic regression was used to determine whether other factors (age, gender, R.E.N.A.L. score, R.E.N.A.L. score components and nomograms based on R.E.N.A.L. score) could improve assignment. RESULTS: Of the 202 small renal masses 53 (26%) were assigned to surveillance and 149 (74%) were assigned to treatment by the risk stratification algorithm. Of the 53 lesions assigned to surveillance 25 (47%) had benign/favorable renal mass biopsy histology while in 28 (53%) intermediate renal mass biopsy histology showed a mass size less than 2 cm. Nine of these 53 masses (17%) were incorrectly assigned to surveillance in that final pathology indicated the need for treatment (ie intermediate histology and a mass greater than 2 cm or unfavorable histology). Final pathology confirmed a correct assignment in all 149 masses assigned to treatment. None of the additional parameters assessed improved assignment with statistical significance. CONCLUSIONS: Age, gender, R.E.N.A.L. nephrometry score, R.E.N.A.L. score components and nomograms or combinations of these factors do not improve the predictive performance of a small renal mass management risk stratification algorithm based on renal mass biopsy and radiographic mass size.


Asunto(s)
Algoritmos , Neoplasias Renales/patología , Neoplasias Renales/terapia , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Biopsia , Femenino , Humanos , Neoplasias Renales/epidemiología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores Sexuales , Carga Tumoral , Espera Vigilante
13.
AJR Am J Roentgenol ; 205(2): 348-52, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26204286

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the accuracy of our autoinitialized cascaded level set 3D segmentation system as compared with the World Health Organization (WHO) criteria and the Response Evaluation Criteria In Solid Tumors (RECIST) for estimation of treatment response of bladder cancer in CT urography. MATERIALS AND METHODS: CT urograms before and after neoadjuvant chemo-therapy treatment were collected from 18 patients with muscle-invasive localized or locally advanced bladder cancers. The disease stage as determined on pathologic samples at cystectomy after chemotherapy was considered as reference standard of treatment response. Two radiologists measured the longest diameter and its perpendicular on the pre- and posttreatment scans. Full 3D contours for all tumors were manually outlined by one radiologist. The autoinitialized cascaded level set method was used to automatically extract 3D tumor boundary. The prediction accuracy of pT0 disease (complete response) at cystectomy was estimated by the manual, autoinitialized cascaded level set, WHO, and RECIST methods on the basis of the AUC. RESULTS: The AUC for prediction of pT0 disease at cystectomy was 0.78 ± 0.11 for autoinitialized cascaded level set compared with 0.82 ± 0.10 for manual segmentation. The difference did not reach statistical significance (p = 0.67). The AUCs using RECIST criteria were 0.62 ± 0.16 and 0.71 ± 0.12 for the two radiologists, both lower than those of the two 3D methods. The AUCs using WHO criteria were 0.56 ± 0.15 and 0.60 ± 0.13 and thus were lower than all other methods. CONCLUSION: The pre- and posttreatment 3D volume change estimates obtained by the radiologist's manual outlines and the autoinitialized cascaded level set segmentation were more accurate for irregularly shaped tumors than were those based on RECIST and WHO criteria.


Asunto(s)
Tomografía Computarizada por Rayos X/métodos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Urografía/métodos , Adulto , Anciano , Cistectomía , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Terapia Neoadyuvante , Invasividad Neoplásica , Estadificación de Neoplasias , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Resultado del Tratamiento , Neoplasias de la Vejiga Urinaria/tratamiento farmacológico , Neoplasias de la Vejiga Urinaria/patología , Neoplasias de la Vejiga Urinaria/cirugía , Organización Mundial de la Salud
14.
Pediatr Radiol ; 45(8): 1160-8, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25794486

RESUMEN

BACKGROUND: There is a paucity of literature describing and comparing the imaging features of adrenocortical adenomas and carcinomas in children and adolescents. OBJECTIVE: To document the CT and MRI features of adrenocortical neoplasms in a pediatric population and to determine whether imaging findings (other than metastatic disease) can distinguish adenomas from carcinomas. MATERIALS AND METHODS: We searched institutional medical records to identify pediatric patients with adrenocortical neoplasms. Pre-treatment CT and MRI examinations were reviewed by two radiologists in consensus, and pertinent imaging findings were documented. We also recorded relevant histopathological, demographic, clinical follow-up and survival data. We used the Student's t-test and Wilcoxon rank sum test to compare parametric and nonparametric continuous data, and the Fisher exact test to compare proportions. We used receiver operating characteristic (ROC) curve analyses to evaluate the diagnostic performances of tumor diameter and volume for discriminating carcinoma from adenoma. A P-value ≤0.05 was considered statistically significant. RESULTS: Among the adrenocortical lesions, 9 were adenomas, 15 were carcinomas, and 1 was of uncertain malignant potential. There were no differences in mean age, gender or sidedness between adenomas and carcinomas. Carcinomas were significantly larger than adenomas based on mean estimated volume (581 ml, range 16-2,101 vs. 54 ml, range 3-197 ml; P-value = 0.003; ROC area under the curve = 0.92) and mean maximum transverse plane diameter (9.9 cm, range 3.0-14.9 vs. 4.4 cm, range 1.9-8.2 cm; P-value = 0.0001; ROC area under the curve = 0.92). Carcinomas also were more heterogeneous than adenomas on post-contrast imaging (13/14 vs. 2/9; odds ratio [OR] = 45.5; P-value = 0.001). Six of 13 carcinomas and 1 of 8 adenomas contained calcification at CT (OR = 6.0; P-value = 0.17). Seven of 15 children with carcinomas exhibited metastatic disease at diagnosis, and three had inferior vena cava invasion. Median survival for carcinomas was 27 months. CONCLUSION: In our experience, pediatric adrenocortical carcinomas are larger, more heterogeneous, and more often calcified than adenomas, although there is overlap in their imaging appearances.


Asunto(s)
Neoplasias de la Corteza Suprarrenal/diagnóstico , Adenoma Corticosuprarrenal/diagnóstico , Carcinoma Corticosuprarrenal/diagnóstico , Adolescente , Corteza Suprarrenal/diagnóstico por imagen , Corteza Suprarrenal/patología , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Lactante , Imagen por Resonancia Magnética , Masculino , Variaciones Dependientes del Observador , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
15.
Radiology ; 272(1): 123-31, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24617733

RESUMEN

PURPOSE: To compare frequency and severity of arterial phase respiratory motion-related artifact following gadoxetate disodium and gadobenate dimeglumine in matched patients administered both contrast media at different times. MATERIALS AND METHODS: Institutional review board approval was obtained, with patient consent waived, for this retrospective, HIPAA-compliant study. Ninety patients underwent gadobenate dimeglumine-enhanced abdominal magnetic resonance (MR) followed by gadoxetate disodium-enhanced abdominal MR and were matched to 90 patients who were administered the same contrast media in reverse order (180 patients). Matching was based on length of time between paired examinations. Gadobenate dimeglumine dose was weight based (0.1 mmol per kilogram body weight). Gadoxetate disodium dose was typically fixed (10 or 20 mL [off label]). Three readers blinded to contrast agent assigned a respiratory motion-related artifact score (1 [none] to 5 [nondiagnostic]) for nonenhanced, arterial, venous, and late dynamic phases. Frequency of greater new arterial phase respiratory motion-related artifact in each within-patient pair and aggregate rate of new severe transient arterial phase respiratory motion-related artifact (scores ≤ 2, nonenhanced and venous and/or late dynamic phases; ≥ 4, arterial phase) were compared (McNemar test). RESULTS: For groups 1 and 2, respectively, mean dose (gadoxetate disodium, 16.6 mL vs 16.6 mL, P = .99; gadobenate dimeglumine, 18.0 mL vs 17.8 mL, P = .77) and mean time between examinations (191 days vs 191 days, P = .99) were not significantly different between matched populations. Gadoxetate disodium was associated with significantly higher incidence of new arterial phase respiratory motion-related artifact compared with gadobenate dimeglumine (39% vs 10%, P < .0001) and of new severe transient arterial phase respiratory motion-related artifact (18% vs 2%, P < .0001) in patients administered both agents at different times. CONCLUSION: Fixed off-label dose (10 or 20 mL) of gadoxetate disodium is associated with arterial phase respiratory motion-related artifact that is sometimes severe and occurs significantly more often than after gadobenate dimeglumine in patients who received both contrast media.


Asunto(s)
Artefactos , Medios de Contraste , Gadolinio DTPA , Hepatopatías/diagnóstico , Imagen por Resonancia Magnética/métodos , Respiración , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste/administración & dosificación , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Movimiento , Estudios Retrospectivos , Factores de Riesgo
16.
Abdom Imaging ; 39(1): 86-91, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24271078

RESUMEN

OBJECTIVE: Oncocytic adrenal neoplasms (OANs) are rare, but are an important subtype of adrenal tumors that is being diagnosed with increasing frequency. Unfortunately, the imaging characteristics of this tumor have not been well described. Our purpose was to identify CT features to differentiate OANs from adrenocortical carcinomas (ACC). MATERIALS AND METHODS: From 1991 to 2012, 18 patients with OANs were identified from our institution's pathology database. Twelve had CT examinations available for review. CT characteristics of five benign and seven malignant OANs were reviewed by two abdominal radiologists, and compared to ACC (n = 10). Morphologic characteristics and density measurements were recorded for each imaging phase. Absolute contrast washout was calculated and compared. RESULTS: Benign OANs were smaller [mean size 3.7 cm (range 2.6-5.3)] and more homogeneous than malignant OANs and demonstrated greater washout [mean washout percentage 72.3% (range 61-88)]. Malignant OANs demonstrated features similar to ACCs, including size [mean 9.4 cm (range 5.2-9.8)] and internal necrosis (n = 6). Mean enhancement washout percentage for malignant OANs was 12% (range -8 to 32). CONCLUSION: Benign OANs (oncocytomas) may be distinguished from lipid-rich adenomas on non-contrast CT but may be indistinguishable from lipid-poor adenomas. Malignant oncocytic neoplasms can demonstrate features similar to ACCs, including larger size, internal necrosis, and lower percentage enhancement washout.


Asunto(s)
Neoplasias de la Corteza Suprarrenal/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Carcinoma Corticosuprarrenal/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adolescente , Neoplasias de la Corteza Suprarrenal/patología , Neoplasias de las Glándulas Suprarrenales/patología , Carcinoma Corticosuprarrenal/patología , Adulto , Anciano , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
17.
Abdom Imaging ; 39(3): 533-42, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24535480

RESUMEN

PURPOSE: To determine whether the frequency of intra-observer measurement discrepancies ≥5 mm for solid renal masses varies by renal mass characteristics and CT contrast phase. MATERIALS AND METHODS: This HIPAA-compliant retrospective study was approved by our IRB. We selected single CT images performed during the nephrographic phase (NP) of renal enhancement in 97 patients, each with a single solid renal mass. Mass location, margin, heterogeneity, and growth pattern were assessed. Six readers measured each mass on two occasions >3 weeks apart. Readers also measured the masses on images in 50 patients who had corticomedullary phase (CMP) images obtained during the same study. Results were assessed using Chi-square/Fisher's exact and Wilcoxon Signed Rank tests, and logistic regression analyses. RESULTS: For NP to NP comparisons, intra-reader measurement differences ≥5 mm were seen for 3.7% (17/463) of masses <4 cm, but increased to 16.8% (20/119) for masses >4 cm (p < 0.0001). Masses with poorly defined margins (15.9% [22/138] vs. 3.4% [15/444] for well-defined margins, p < 0.0001) and heterogeneity (15.3% [22/144], vs. 5.0% [14/282] for minimally heterogeneous, vs. 0.6% [1/156] for homogeneous, p < 0.0001), were more frequently associated with measurement differences ≥5 mm. Differences ≥5 mm were more frequent when only CMP images were utilized (14% [42/299]), or when CMP images were compared with NP images (26% [77/299]). CONCLUSIONS: A ≥5 mm intra-reader variation in measured size of solid renal masses <4 cm is uncommon for NP to NP comparisons. Variation increases when masses are ≥4 cm, poorly defined, or heterogeneous; or when CMP images are utilized.


Asunto(s)
Medios de Contraste , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada Espiral/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Riñón/diagnóstico por imagen , Riñón/patología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Carga Tumoral
18.
Surg Radiol Anat ; 36(10): 1051-5, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24435023

RESUMEN

PURPOSE: The purpose of this study was to establish normative data for the CT appearance of inguinal lymph nodes. MATERIALS AND METHODS: After Institutional Review Board approval, search of the radiology information system identified 500 consecutive CT examinations of the pelvis. Patients were included if no lower extremity or perineum pathology, or history of malignancy at the time of CT examination, and a clinical note documenting no tumor at least 2 years after the CT. The final study group was 77 patients. CT examinations were retrospectively reviewed and bilateral inguinal lymph nodes were characterized by size (short axis and largest size in general), number, and presence of fat attenuation. RESULTS: The mean short-axis inguinal lymph node size was 5.4 mm (range 2.1-13.6 mm), measured at 8.8 mm two standard deviations above the mean. The mean number of superficial and deep inguinal lymph nodes was 10.7 (range 3-18) and 1.2 per patient (range 1-2), respectively. Superficial and deep inguinal nodes showed internal fat attenuation in 85 and 78% of nodes, and were oval in shape in 95 and 78%, respectively. CONCLUSION: Inguinal lymph nodes in asymptomatic patients have a mean short axis of 5.4 mm, a short axis of 8.8 mm at two standard deviations above the mean, and are multiple and symmetric in size and number (4-20 per patient). Normal inguinal lymph nodes were commonly oval in shape and contained fat, although such findings may be absent in smaller lymph nodes.


Asunto(s)
Conducto Inguinal/anatomía & histología , Conducto Inguinal/diagnóstico por imagen , Ganglios Linfáticos/anatomía & histología , Ganglios Linfáticos/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Estudios Retrospectivos , Adulto Joven
19.
Cancers (Basel) ; 16(13)2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-39001463

RESUMEN

Survival prediction post-cystectomy is essential for the follow-up care of bladder cancer patients. This study aimed to evaluate artificial intelligence (AI)-large language models (LLMs) for extracting clinical information and improving image analysis, with an initial application involving predicting five-year survival rates of patients after radical cystectomy for bladder cancer. Data were retrospectively collected from medical records and CT urograms (CTUs) of bladder cancer patients between 2001 and 2020. Of 781 patients, 163 underwent chemotherapy, had pre- and post-chemotherapy CTUs, underwent radical cystectomy, and had an available post-surgery five-year survival follow-up. Five AI-LLMs (Dolly-v2, Vicuna-13b, Llama-2.0-13b, GPT-3.5, and GPT-4.0) were used to extract clinical descriptors from each patient's medical records. As a reference standard, clinical descriptors were also extracted manually. Radiomics and deep learning descriptors were extracted from CTU images. The developed multi-modal predictive model, CRD, was based on the clinical (C), radiomics (R), and deep learning (D) descriptors. The LLM retrieval accuracy was assessed. The performances of the survival predictive models were evaluated using AUC and Kaplan-Meier analysis. For the 163 patients (mean age 64 ± 9 years; M:F 131:32), the LLMs achieved extraction accuracies of 74%~87% (Dolly), 76%~83% (Vicuna), 82%~93% (Llama), 85%~91% (GPT-3.5), and 94%~97% (GPT-4.0). For a test dataset of 64 patients, the CRD model achieved AUCs of 0.89 ± 0.04 (manually extracted information), 0.87 ± 0.05 (Dolly), 0.83 ± 0.06~0.84 ± 0.05 (Vicuna), 0.81 ± 0.06~0.86 ± 0.05 (Llama), 0.85 ± 0.05~0.88 ± 0.05 (GPT-3.5), and 0.87 ± 0.05~0.88 ± 0.05 (GPT-4.0). This study demonstrates the use of LLM model-extracted clinical information, in conjunction with imaging analysis, to improve the prediction of clinical outcomes, with bladder cancer as an initial example.

20.
Radiology ; 267(1): 94-105, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23360737

RESUMEN

PURPOSE: To determine whether intravenous low-osmolality iodinated contrast material is associated with post-computed tomography (CT) acute kidney injury (AKI). MATERIALS AND METHODS: Institutional review board approval was obtained and patient consent waived for this HIPAA-compliant retrospective study. CT examinations performed over a 10-year period in adult inpatients with sufficient serum creatinine (SCr) data were identified. A one-to-one propensity-matched matched cohort analysis with multivariate analysis of effects was performed with post-CT AKI as the primary outcome measure (10,121 unenhanced and 10,121 intravenous contrast-enhanced CT examinations in 20,242 patients). Propensity matching was performed with respect to likelihood of patient receiving intravenous contrast material (36 tested covariates). The primary endpoint was post-CT AKI by using Acute Kidney Injury Network SCr criteria; the secondary endpoint was post-CT AKI by using traditional SCr criteria for contrast material-induced nephrotoxicity (CIN; SCr increase ≥0.5 mg/dL [44.20 µmol/L] or ≥25%). Multivariate subgroup threshold analysis was performed (SCr <1.5 [<132.60 µmol/L]; ≥1.5 to ≥2.0 mg/dL [≥132.60 to ≥176.80 µmol/L]) and adjusted for assigned propensity scores. RESULTS: Intravenous low-osmolality iodinated contrast material had a significant effect on the development of post-CT AKI for patients with pre-CT SCr levels of 1.6 mg/dL (141.44 µmol/L) or greater (odds ratio, 1.45; 95% confidence interval [CI]: 1.11, 1.89;P = .007). This effect strengthened as pre-CT SCr increased. Patients with stable SCr less than 1.5 mg/dL (132.60 µmol/L) were not at risk for developing CIN (P = .25, power > 95%). Both endpoints demonstrated similar results (eg, SCr ≥1.6 mg/dL [141.44 µmol/L] by using traditional CIN criteria: odds ratio, 1.64; 95% CI: 1.18, 2.28; P = .003). Post-CT AKI was prevalent in both the unenhanced and contrast-enhanced CT subgroups, and it increased with increases in pre-CT SCr. Many risk factors contributed to development of post-CT AKI, regardless of iodinated contrast material. CONCLUSION: Intravenous low-osmolality iodinated contrast material is a nephrotoxic risk factor, but not in patients with a stable SCr level less than 1.5 mg/dL. Many factors other than contrast material can affect post-CT AKI rates.


Asunto(s)
Medios de Contraste/efectos adversos , Enfermedades Renales/inducido químicamente , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Medios de Contraste/química , Femenino , Humanos , Inyecciones Intravenosas , Yohexol/efectos adversos , Yohexol/análogos & derivados , Yopamidol/efectos adversos , Pruebas de Función Renal , Modelos Logísticos , Masculino , Persona de Mediana Edad , Concentración Osmolar , Puntaje de Propensión , Estudios Retrospectivos , Factores de Riesgo , Ácidos Triyodobenzoicos/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA