Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Phys Rev Lett ; 105(10): 101601, 2010 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-20867509

RESUMEN

We have extracted QCD matrix elements from our data on doubly polarized inelastic scattering of electrons on nuclei. We find the higher twist matrix element d˜2, which arises strictly from quark-gluon interactions, to be unambiguously nonzero. The data also reveal an isospin dependence of higher twist effects if we assume that the Burkhardt-Cottingham sum rule is valid. The fundamental Bjorken sum rule obtained from the a0 matrix element is satisfied at our low momentum transfer.

2.
Appl Radiat Isot ; 66(4): 421-34, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18222090

RESUMEN

Within the EURopean Illicit TRAfficking Countermeasures Kit (EURITRACK) project, the gamma-ray spectra produced in a series of materials by 14-MeV tagged-neutron beams have been collected in the inspection portal equipped with large volume NaI(Tl) detectors, in order to build a database of signatures for various elements: C, N, O, Na, Al, Si, Cl, K, Ca, Cr, Fe, Ni, Cu, Zn, Pb. The measured spectra have been compared with prediction from Monte Carlo simulations to verify the consistency of the relevant nuclear data inputs. This library of measured 14-MeV neutron-induced gamma-ray spectra is currently used in a data processing algorithm to unfold the energy spectra of the transported goods into elementary contributions, thus allowing material identification.

3.
Appl Radiat Isot ; 70(7): 1367-9, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22100378

RESUMEN

In neutron Time-of-Flight (TOF) measurements performed with fast organic scintillation detectors, both pulse arrival time and amplitude are relevant. Monte Carlo simulation can be used to calculate the time-energy dependant neutron flux at the detector position. To convert the flux into a pulse height spectrum, one must calculate the detector response function for mono-energetic neutrons. MCNP can be used to design TOF systems, but standard MCNP versions cannot reliably calculate the energy deposited by fast neutrons in the detector since multiple scattering effects must be taken into account in an analog way, the individual recoil particles energy deposit being summed with the appropriate scintillation efficiency. In this paper, the energy response function of 2″×2″ and 5″×5″ liquid scintillation BC-501 A (Bicron) detectors to fast neutrons ranging from 20 keV to 5.0 MeV is computed with GEANT4 to be coupled with MCNPX through the "MCNP Output Data Analysis" software developed under ROOT (Carasco, 2010).

4.
Appl Radiat Isot ; 70(7): 1261-3, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22406218

RESUMEN

The French Alternative Energies and Atomic Energy Commission (CEA) and National Radioactive Waste Management Agency (ANDRA) are conducting an R&D program to improve the characterization of long-lived and medium activity (LL-MA) radioactive waste packages. In particular, the amount of toxic elements present in radioactive waste packages must be assessed before they can be accepted in repository facilities in order to avoid pollution of underground water reserves. To this aim, the Nuclear Measurement Laboratory of CEA-Cadarache has started to study the performances of Prompt Gamma Neutron Activation Analysis (PGNAA) for elements showing large capture cross sections such as mercury, cadmium, boron, and chromium. This paper reports a comparison between Monte Carlo calculations performed with the MCNPX computer code using the ENDF/B-VII.0 library and experimental gamma rays measured in the REGAIN PGNAA cell with small samples of nickel, lead, cadmium, arsenic, antimony, chromium, magnesium, zinc, boron, and lithium to verify the validity of a numerical model and gamma-ray production data. The measurement of a ∼20kg test sample of concrete containing toxic elements has also been performed, in collaboration with Forschungszentrum Jülich, to validate the model in view of future performance studies for dense and large LL-MA waste packages.

5.
Appl Radiat Isot ; 70(7): 1186-92, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21782459

RESUMEN

Fast neutron interrogation with the associated particle technique can be used to identify explosives in cargo containers (EURITRACK FP6 project) and unexploded ordnance on the seabed (UNCOSS FP7 project), by detecting gamma radiations induced by 14 MeV neutrons produced in the 2H(3H,α)n reaction. The origin of the gamma rays can be determined in 3D by the detection of the alpha particle, which provides the direction of the opposite neutron and its time-of-flight. Gamma spectroscopy provides the relative counts of carbon, nitrogen, and oxygen, which are converted to chemical fractions to differentiate explosives from other organic substances. To this aim, Monte Carlo calculations are used to take into account neutron moderation and gamma attenuation in cargo materials or seawater. This paper presents an experimental verification that C, N, and O counts are correctly reproduced by numerical simulation. A quantitative comparison is also reported for silicon, iron, lead, and aluminium.

6.
Appl Radiat Isot ; 69(5): 732-43, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21295986

RESUMEN

Gamma-ray spectra produced in carbon, nitrogen, oxygen, sodium, aluminium, silicon, chlorine, calcium, chromium, iron, nickel, copper, zinc, and lead by 14 MeV tagged neutrons have been collected with NaI(Tl) detectors of the EURITRACK system, which low-energy threshold has been reduced to 0.6 MeV to detect gamma rays of major elements like iron. The spectra have been compared with Monte Carlo simulations to check the tabulated gamma-ray production data. A quantitative approach to subtract the scattered neutron background is also reported.

8.
Plant Cell Rep ; 14(12): 748-52, 1995 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24186705

RESUMEN

Some conditions related to the transient expression of ß-glucuronidase in biolistically-treated Coffea spp. tissues were investigated, and subsequently used in a promoter study. Bombardments were performed on different types of tissue (leaves, somatic embryos and suspension cultures) of genotypes of C. arabica, C. canephora and Arabusta, using 4 different promoter sequences. Tobacco leaves were used as a comparison. In general, similar large variation and mean values of transient expression were observed between coffee and tobacco leaves. With regard to the coffee tissues effect, transient expression was best detectable and most frequently observed with bombarded leaves of microcuttings. Disturbing endogenous light blue staining was found with control treatments of somatic embryos. For the three coffee species tested, the most effective promoter was the EF1α-A1 promoter of Arabidopsis thaliana.

9.
Genome ; 47(6): 1071-81, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15644965

RESUMEN

Primer sets were developed from 85 Coffea arabica sequences in addition to 25 already published primer sets. They were subsequently used for amplification in six African Coffea species: Coffea canephora (CAN), Coffea eugenioides (EUG), Coffea heterocalyx (HET), Coffea liberica (LIB), Coffea sp. Moloundou (MOL) and Coffea pseudozanguebariae (PSE). The amplification percentages for these 110 primer pairs ranged from 72.7% for LIB to 86.4% for PSE. Good transferability was thus obtained within the Coffea genus. When focusing on the two species CAN and PSE, high genetic diversity, high polymorphic locus rates (above 80%) and a mean allele number per polymorphic locus of more than 3 were noted. The estimated null allele percentage was -11% for PSE and -9% for CAN. Sixty three percent (CAN) and 79.5% (PSE) of the fixation index (Fis) values were positive. The within-species polymorphism information content (PIC) distribution showed two modes for both species. Although the two species shared 30 polymorphic loci, no correlation between CAN and PSE PIC values was obtained. All of these data are discussed in relation to the polymorphism level and the potential use of these SSRs for subsequent analysis of genetic diversity or genetic mapping.


Asunto(s)
Coffea/genética , Secuencias Repetitivas de Ácidos Nucleicos , Alelos , Mapeo Cromosómico , Cartilla de ADN/química , Cartilla de ADN/genética , ADN de Plantas/química , Marcadores Genéticos , Variación Genética , Genoma de Planta , Filogenia , Reacción en Cadena de la Polimerasa , Polimorfismo Genético , Programas Informáticos , Factores de Tiempo
10.
Phys Rev Lett ; 93(18): 182501, 2004 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-15525158

RESUMEN

We have carried out an (e,e'p) experiment at high momentum transfer and in parallel kinematics to measure the strength of the nuclear spectral function S(k,E) at high nucleon momenta k and large removal energies E. This strength is related to the presence of short-range and tensor correlations, and was known hitherto only indirectly and with considerable uncertainty from the lack of strength in the independent-particle region. This experiment locates by direct measurement the correlated strength predicted by theory.

11.
Phys Rev Lett ; 92(4): 042301, 2004 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-14995367

RESUMEN

The electric form factor of the neutron was determined from measurements of the d-->(e-->,e'n)p reaction for quasielastic kinematics. Polarized electrons were scattered off a polarized deuterated ammonia (15ND3) target in which the deuteron polarization was perpendicular to the momentum transfer. The scattered electrons were detected in a magnetic spectrometer in coincidence with neutrons in a large solid angle detector. We find G(n)(E)=0.0526+/-0.0033(stat)+/-0.0026(sys) and 0.0454+/-0.0054+/-0.0037 at Q(2)=0.5 and 1.0 (GeV/c)(2), respectively.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA