Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
AJR Am J Roentgenol ; 208(3): 552-563, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28225687

RESUMEN

OBJECTIVE: The purpose of this study is to determine whether image quality was maintained when a weight-based protocol incorporating tube potential selection was used to select lower iodine contrast volumes for aortic CT angiography (CTA). MATERIALS AND METHODS: Patients with potentially decreased renal function underwent CTA performed with the iodinated contrast volume determined using a table incorporating different tube potentials and patient weights. The image quality of CTA examinations performed with a reduced iodine volume (hereafter known as "low-iodine CTA examinations"), internal control CTA examinations (i.e., prior examinations), and size-matched control CTA examinations was evaluated in separate reading sessions conducted by three vascular radiologists who were blinded as to the contrast volume and tube potential used. Side-by-side unblinded comparison of the examinations was also performed. Aortic attenuation and the contrast-to-noise ratio were measured. Comparisons were performed using the Wilcoxon signed rank test. RESULTS: Fifty low-iodine CTA examinations, 36 internal control CTA examinations, and 50 size-matched control CTA examinations were performed. Contrast volumes were 63% lower when the protocol based on tube potential and patient weight was used (mean contrast volume, 49 mL for low-iodine CTA vs 133 mL for internal control CTA and 138 mL for size-matched control CTA). The mean volume CT dose index was 15.1 mGy for low-iodine CTA versus 18.8 mGy for internal control CTA (p < 0.001), and 15.3 mGy for low-iodine CTA versus 17.1 mGy for size-matched control CTA (p = 0.11). Of the image quality and diagnostic confidence evaluations for low-iodine CTA examinations, over 97% had acceptable image quality and diagnostic confidence for blinded (50/50) and unblinded (35/36) comparisons. Aortic attenuation was similar between groups (p = 0.13-0.71). CONCLUSION: A weight-based protocol that incorporates tube potential selection allows the use of substantially lower volumes of iodinated contrast material in aortic CTA while maintaining acceptable image quality.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Aortografía/métodos , Angiografía por Tomografía Computarizada/métodos , Yodo/administración & dosificación , Intensificación de Imagen Radiográfica/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Medios de Contraste/administración & dosificación , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Integración de Sistemas , Adulto Joven
2.
Dent Mater ; 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39304479

RESUMEN

OBJECTIVES: To evaluate the influence of microstructure and chemical composition on the optical properties of CAD-CAM lithium disilicate glass-ceramics. METHODS: Samples (n = 5; 1.0 mm thickness) of shades A1, A2, and A3 were fabricated from CAD-CAM ceramic blocks (Ivoclar Vivadent): IPS e.max® CAD LT (emLT) and HT (emHT). Samples were polished to 1.0 ± 0.01 mm in thickness. The optical properties (R- reflectance; T- transmittance; µs'- reduced scattering and µa- absorption coefficients) from the post-crystallized samples were determined using the inverse adding-doubling (IAD) method based on integrating-sphere measurements. Additionally, scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques were used to evaluate the microstructural properties. Energy-dispersive X-ray (EDX) was employed to analyze the chemical composition. The chemical and structural characterization were performed before and after crystallization of the ceramic samples. RESULTS: emLT showed higher values of µs'and lower values of µa and T than emHT for each shade in all wavelengths (p < 0.003). Considering T for emHT, there were no statistical differences for shades A1 and A2 at 488 nm and 514.5 nm (p > 0.003) and shades A1 and A3 at 457.9 nm (p > 0.003). emLT showed particle length ranging from 0.74 to 2.78 µm (mean = 1.57 µm and RF-relative frequency = 28 %) and particle width ranging from 0.21 to 0.74 µm (mean = 0.30 µm and RF = 31 %). emHT showed particle length ranging from 0.83 to 3.08 µm (mean = 1.86 µm and RF = 21 %) and particle width ranging from 0.24 to 1.12 µm (mean = 0.56 µm and RF = 28 %). In comparison with emHT, emLT showed greater vol% for C, K, and Zr and lower vol% for O and Al. SIGNIFICANCE: The optical properties of CAD-CAM lithium disilicate glass-ceramics are influenced by the chemical composition and, consequently, by the material microstructure.

3.
Materials (Basel) ; 16(4)2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36837057

RESUMEN

Transparent conductive electrodes have become essential components of numerous optoelectronic devices. However, their optical properties are typically characterized by the direct transmittance achieved by making use of spectrophotometers, avoiding an in-depth knowledge of the processes involved in radiation attenuation. A different procedure based on the Double Integration Sphere combined with the numerical Inverse Adding-Doubling (IAD) method is employed in this work to provide a comprehensive description of the physical processes limiting the light transmittance in commercial indium tin oxide (ITO) deposited on flexible PET samples, highlighting the noticeable contribution of light scattering on the total extinction of radiation. Moreover, harnessing their flexibility, the samples were subjected to different mechanical stresses to assess their impact on the material's optical and electrical properties.

4.
Biomedicines ; 10(7)2022 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-35884945

RESUMEN

The most recent generation of bioengineered human skin allows for the efficient treatment of patients with severe skin defects. Despite UV sunlight can seriously affect human skin, the optical behavior in the UV range of skin models is still unexplored. In the present study, absorbance and transmittance of the UGRSKIN bioartificial skin substitute generated with human skin cells combined with fibrin-agarose biomaterials were evaluated for: UV-C (200−280 nm), -B (280−315 nm), and -A (315−400 nm) spectral range after 7, 14, 21 and 28 days of ex vivo development. The epidermis of the bioartificial skin substitute was able to mature and differentiate in a time-dependent manner, expressing relevant molecules able to absorb most of the incoming UV radiation. Absorbance spectral behavior of the skin substitutes showed similar patterns to control native skin (VAF > 99.4%), with values 0.85−0.90 times lower than control values at 7 and 14- days and 1.05−1.10 times the control values at 21- and 28-days. UV absorbance increased, and UV transmission decreased with culture time, and comparable results to the control were found at 21 and 28 days. These findings support the use of samples corresponding to 21 or 28 days of development for clinical purposes due to their higher histological similarities with native skin, but also because of their absorbance of UV radiation.

5.
Micromachines (Basel) ; 13(11)2022 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-36363950

RESUMEN

A full comprehension of colorimetric relationships within and between teeth is key for aesthetic success of a dental restoration. In this sense, hyperspectral imaging can provide point-wise reliable measurements of the tooth surface, which can serve for this purpose. The aim of this study was to use a hyperspectral imaging system for the colorimetric characterization of 4 in-vivo maxillary anterior teeth and to cross-check the results with similar studies carried out with other measuring systems in order to validate the proposed capturing protocol. Hyperspectral reflectance images (Specim IQ), of the upper central (UCI) and lateral incisors (ULI), were captured on 30 participants. CIE-L*a*b* values were calculated for the incisal (I), middle (M) and cervical (C) third of each target tooth. ΔEab* and ΔE00 total color differences were computed between different tooth areas and adjacent teeth, and evaluated according to the perceptibility (PT) and acceptability (AT) thresholds for dentistry. Non-perceptible color differences were found between UCIs and ULIs. Mean color differences between UCI and ULI exceeded AT (ΔEab* = 7.39-7.42; ΔE00 = 5.71-5.74) in all cases. Large chromatic variations between I, M and C areas of the same tooth were registered (ΔEab* = 5.01-6.07 and ΔE00 = 4.07-5.03; ΔEab* = 5.80-8.16 and ΔE00 = 4.37-5.15; and ΔEab* = 5.42-5.92 and ΔE00 = 3.87-4.16 between C and M, C and I and M and I, respectively). The use of a hyperspectral camera has proven to be a reliable and effective method for color evaluation of in-vivo natural teeth.

6.
J Dent ; 105: 103560, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33352224

RESUMEN

OBJECTIVE: To determine in-vivo chromatic and whiteness changes produced by short-term dental dehydration. METHODS: Spectral reflectance of 452 upper incisors (226 centrals and 226 laterals) of 113 participants were measured using a spectroradiometer at baseline and after short-term dehydration (minutes 2, 4, 6, 8 and 10). CIE L*a*b* color coordinates (L*, a*, b*, C*ab and hab) and whiteness index for dentistry (WID) were calculated. Color differences (ΔE00, ΔEab*) and whiteness differences (ΔWID) were computed and interpreted based on their respective 50:50% perceptibility (PT) and acceptability thresholds (AT). Statistical analysis was performed using the related samples Wilcoxon signed-rank test. RESULTS: L* showed an increasing trend with dehydration, while a*, b*, C*ab and hab have a decreasing tendency. All chromatic coordinates showed statistically significant differences (p < 0.003) at each interval of dehydration compared with baseline, except a* for all teeth. For ΔE00 and ΔEab* values were higher than PT after 2 min of teeth dehydration and higher than AT after 6 and 8 min, respectively. The percentage of teeth exceeding corresponding PT was higher than 50% after 2 min. WID index increased with dehydration time, while whiteness differences were clinically perceptible after 4 min. Statistically significant differences were found for WID between all dehydration intervals (except 8-10 min). The percentage of teeth exceeding whiteness PT was higher than 50% after 6 min of teeth dehydration. CONCLUSIONS: Short-term dental dehydration produces clinically unacceptable changes in tooth color and clinically perceptible increase in tooth whiteness level. CLINICAL SIGNIFICANCE: Clinical shade matching must be done within the first two minutes of any clinical procedure that requires precise chromatic determination but implies a risk of tooth dehydration.


Asunto(s)
Deshidratación , Incisivo , Color , Percepción de Color , Humanos , Incisivo/diagnóstico por imagen
7.
Appl Opt ; 49(3): 422-9, 2010 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-20090806

RESUMEN

Tooth bleaching is becoming increasingly popular among patients and dentists since it is a relatively noninvasive approach for whitening and lightening teeth. Instruments and visual assessment with respect to commercial shade guides are currently used to evaluate tooth color. However, the association between these procedures is imprecise and the degree of color change after tooth bleaching is known to vary substantially between studies; there are currently no objective guidelines to predict the effectiveness of a tooth-bleaching treatment. We propose a new methodology based on fuzzy logic as a natural means of representing the imprecision present when modeling the color change produced by a tooth-bleaching treatment on the basis of a tooth's initial chromatic values. This system has the advantage of producing a set of interpretable fuzzy rules that can subsequently be used by scientists and dental practitioners. The fuzzy system obtained has the special characteristic whereby the rule antecedents correspond to prebleaching shades of the well-known Vita commercial shade guide. Additionally, the rule consequents directly correspond with the expected CIELAB postbleaching values for each Vita shade, thanks to a modification of the system's inference structure. Finally, the values of these postbleaching CIELAB coordinates have been associated with Vita shades by evaluating their respective membership functions, thereby approximating which posttreatment Vita shades are to be expected for each prebleaching shade.


Asunto(s)
Color , Blanqueamiento de Dientes , Adulto , Anciano , Femenino , Lógica Difusa , Humanos , Masculino , Persona de Mediana Edad , Fenómenos Ópticos , Decoloración de Dientes/patología , Decoloración de Dientes/terapia , Adulto Joven
8.
Biomaterials ; 121: 205-219, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28092777

RESUMEN

Ideally, biomaterials designed to play specific physical and physiological roles in vivo should comprise components and microarchitectures analogous to those of the native tissues they intend to replace. For that, implantable biomaterials need to be carefully designed to have the correct structural and compositional properties, which consequently impart their bio-function. In this study, we showed that the control of such properties can be defined from the bottom-up, using smart surface templates to modulate the structure, composition, and bio-mechanics of human transplantable tissues. Using multi-functional peptide amphiphile-coated surfaces with different anisotropies, we were able to control the phenotype of corneal stromal cells and instruct them to fabricate self-lifting tissues that closely emulated the native stromal lamellae of the human cornea. The type and arrangement of the extracellular matrix comprising these corneal stromal Self-Lifting Analogous Tissue Equivalents (SLATEs) were then evaluated in detail, and was shown to correlate with tissue function. Specifically, SLATEs comprising aligned collagen fibrils were shown to be significantly thicker, denser, and more resistant to proteolytic degradation compared to SLATEs formed with randomly-oriented constituents. In addition, SLATEs were highly transparent while providing increased absorption to near-UV radiation. Importantly, corneal stromal SLATEs were capable of constituting tissues with a higher-order complexity, either by creating thicker tissues through stacking or by serving as substrate to support a fully-differentiated, stratified corneal epithelium. SLATEs were also deemed safe as implants in a rabbit corneal model, being capable of integrating with the surrounding host tissue without provoking inflammation, neo-vascularization, or any other signs of rejection after a 9-months follow-up. This work thus paves the way for the de novo bio-fabrication of easy-retrievable, scaffold-free human tissues with controlled structural, compositional, and functional properties to replace corneal, as well as other, tissues.


Asunto(s)
Materiales Biomiméticos/química , Córnea/citología , Córnea/crecimiento & desarrollo , Sustancia Propia/citología , Sustancia Propia/fisiopatología , Trasplante de Córnea/métodos , Ingeniería de Tejidos/métodos , Células Cultivadas , Epitelio Corneal/citología , Humanos , Impresión Tridimensional
9.
Dent Mater ; 32(5): e105-12, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26994880

RESUMEN

OBJECTIVES: To evaluate relevant optical properties of esthetic direct restorative materials focusing on whitened and translucent shades. METHODS: Enamel (E), body (B), dentin (D), translucent (T) and whitened (Wh) shades for E (WhE) and B (WhB) from a restorative system (Filtek Supreme XTE, 3M ESPE) were evaluated. Samples (1 mm thick) were prepared. Spectral reflectance (R%) and color coordinates (L*, a*, b*, C* and h°) were measured against black and white backgrounds, using a spectroradiometer, in a viewing booth, with CIE D65 illuminant and d/0° geometry. Scattering (S) and absorption (K) coefficients and transmittance (T%) were calculated using Kubelka-Munk's equations. Translucency (TP) and opalescence (OP) parameters and whiteness index (W*) were obtained from differences of CIELAB color coordinates. R%, S, K and T% curves from all shades were compared using VAF (Variance Accounting For) coefficient with Cauchy-Schwarz inequality. Color coordinates and optical parameters were statistically analyzed using one-way ANOVA, Tukey's test with Bonferroni correction (α=0.0007). RESULTS: Spectral behavior of R% and S were different for T shades. In addition, T shades showed the lowest R%, S and K values, as well as the highest T%, TP an OP values. In most cases, WhB shades showed different color and optical properties (including TP and W*) than their corresponding B shades. WhE shades showed similar mean W* values and higher mean T% and TP values than E shades. SIGNIFICANCE: When using whitened or translucent composites, the final color is influenced not only by the intraoral background but also by the color and optical properties of multilayers used in the esthetic restoration.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Color , Esmalte Dental , Dentina , Humanos
10.
J Dent ; 43(6): 726-34, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25748670

RESUMEN

OBJECTIVES: To evaluate colour differences between (1) CAD-CAM ceramic systems considering shades A1, A2 and A3 and the corresponding nominal shade of VC (Vita Classical shade guide) and (2) shades A1-A2, A2-A3 and A1, A2 and A3 within the same ceramic system. METHODS: Samples of shades A1, A2 and A3 were fabricated (n=5) from CAD-CAM ceramic blocks (IPS e.max(®) CAD LT and HT, IPS Empress(®) CAD LT and HT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. Spectral reflectance and colour coordinates were measured using a spectroradiometer inside a viewing booth using the CIE D65 illuminant and the d/0° geometry. Spectral reflectance curves were compared using VAF coefficient and were statistically analyzed using Kruskal-Wallis and the Mann-Whitney U test (α=0.05). Colour coordinates were statistically analyzed using one-way ANOVA, Tukey's test with Bonferroni correction (α=0.001). All colour differences (ΔEab(*) and ΔE00) were analyzed through comparisons with the PT - perceptibility and AT - acceptability thresholds for dental ceramics. RESULTS: ΔE between ceramic systems and its corresponding shade ranged from 6.32 to 13.42 (ΔEab(*)) and 4.48 to 9.30 (ΔE00). ΔE between shades A1-A2, A2-A3 and A1, A2 and A3 ranged, respectively, 1.93-4.82, 1.22-5.59 and 3.63-8.84 (ΔEab(*)); 1.54-3.87, 1.03-3.90 and 2.95-6.51 (ΔE00). CONCLUSIONS: Considering the corresponding nominal shade from VC, none of the ceramic systems showed colour differences below the AT. In addition, some ceramic systems showed colour differences below AT (shades A1-A2 and A2-A3) and below PT (shades A2-A3). CLINICAL SIGNIFICANCE: Careful adjustments should be made to the final shade of CAD-CAM ceramic restorations to reach a clinically acceptable shade match.


Asunto(s)
Cerámica/química , Resinas Compuestas/química , Diseño Asistido por Computadora , Materiales Dentales/química , Coloración de Prótesis , Color , Colorimetría/instrumentación , Colorimetría/métodos , Porcelana Dental/química , Diseño de Prótesis Dental , Propiedades de Superficie
11.
Dent Mater ; 31(1): 60-7, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25499249

RESUMEN

OBJECTIVES: To use the Kubelka-Munk theory to evaluate the scattering (S), absorption (K) and transmittance (T) of non-colored and colored dental zirconia systems and human (HD) and bovine (BD) dentins. METHODS: Two zirconia systems were used: ZC- ZirCAD (Ivoclar Vivadent) and LV-LAVA (3M ESPE). Specimens from each ceramic system were divided into 3 groups (n=5): ZC1 and LV1 (non-colored); ZC2 and LV2 colored to shade A1, and ZC3 and LV3 colored to shade A3. Five human and bovine anterior teeth were flattened and polished through 1200 grit SiC paper to expose the superficial buccal dentin. All samples were prepared to a final thickness of 0.5 mm. Diffuse reflectance was measured against white and black backgrounds, using a spectroradiometer in a viewing booth with D65 illuminant and d/0° geometry. S and K coefficients and T were calculated using Kubelka-Munk's equations. Data was statistically analyzed using Kruskal-Wallis, Mann-Whitney tests, and VAF coefficient. RESULTS: Spectral distributions of S, K and T were wavelength dependent. The spectral behavior of S and T was similar to HD (VAF≥96.80), even though they were statistically different (p≤0.05). The spectral behavior of K was also similar to HD, except for LV1 (VAF=38.62), yet all ceramics were statistically different from HD (p≤0.05). HD and BD showed similar values of S and T (p>0.05). SIGNIFICANCE: The dental professional should consider the optical behavior differences between the zirconia systems evaluated and the human dentin to achieve optimal esthetics in restorative dentistry.


Asunto(s)
Cerámica/química , Dentina/química , Circonio/química , Animales , Bovinos , Color , Estética Dental , Humanos , Óptica y Fotónica , Dispersión de Radiación
12.
J Dent ; 41 Suppl 3: e31-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23507398

RESUMEN

OBJECTIVE: To assess dentine caries removal effectiveness (CRE) and minimal invasiveness potential (MIP) of carbide and polymer burs. METHODS: Sectioned carious molars were photographed. Digital images were taken, before and after caries removal, using a Digital Single Lens Reflex camera. The following regions of interest were measured using visual criteria: Residual Infected Dentine (RI), Residual Affected Dentine (RA), Removal Sound Dentine (RA), Prepared Cavity (PC) and Removed Sound Dentine (RS). CRE was determined on basis of: relative residual infected dentine (RI/II), relative residual carious-affected dentine (RA/IA) and total relative residual dentine (RI+RA/II-IA). MIP was determined on basis of: infected dentine cavity size (PC/II), total relative cavity size (PC/II+IA), and corrected relative cavity size (PC-RS/II+IA). RESULTS: The polymer bur showed the highest preservation of carious-affected dentine after excavation, when the RA/IA ratio was studied. Both kind of burs showed similar values after assessing the RI/II and RI+RA/II-IA ratios. The infected dentine relative cavity size (PC/II) was higher when the carbide bur was used. Both burs attained similar PC/II+IA and PC-RS/II+IA ratios. CONCLUSIONS: Polymer burs accomplished the concept of minimal-invasive dentistry, showing its self-limiting ability. The minimal-invasiveness potential showed that carbide burs resulted in the worst compromise between effective and selective infected-caries removal.


Asunto(s)
Caries Dental/terapia , Preparación de la Cavidad Dental/instrumentación , Dentina/patología , Procesamiento de Imagen Asistido por Computador/métodos , Fotograbar/métodos , Calibración , Carbono/química , Diseño de Equipo , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Diente Molar/patología , Fotograbar/instrumentación , Polímeros/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA