RESUMEN
Recombinant protein polymers were synthesized and examined under various loading conditions to assess the mechanical stability and deformation responses of physically cross-linked, hydrated, protein polymer networks designed as triblock copolymers with central elastomeric and flanking plastic-like blocks. Uniaxial stress-strain properties, creep and stress relaxation behavior, as well as the effect of various mechanical preconditioning protocols on these responses were characterized. Significantly, we demonstrate for the first time that ABA triblock protein copolymers when redesigned with substantially larger endblock segments can withstand significantly greater loads. Furthermore, the presence of three distinct phases of deformation behavior was revealed upon subjecting physically cross-linked protein networks to step and cyclic loading protocols in which the magnitude of the imposed stress was incrementally increased over time. We speculate that these phases correspond to the stretch of polypeptide bonds, the conformational changes of polypeptide chains, and the disruption of physical cross-links. The capacity to select a genetically engineered protein polymer that is suitable for its intended application requires an appreciation of its viscoelastic characteristics and the capacity of both molecular structure and conditioning protocols to influence these properties.
Asunto(s)
Reactivos de Enlaces Cruzados , Poliproteínas/síntesis química , Ingeniería de Proteínas , Elasticidad , Elastómeros , Mecánica , Conformación Proteica , Proteínas Recombinantes/síntesis químicaRESUMEN
A stabilized, membrane-mimetic film was produced on the luminal surface of an ePTFE vascular graft by in situ photopolymerization of an acrylate functonalized phospholipid using a fiber optic diffusing probe. The phospholipid monomer was synthesized, prepared as unilamellar vesicles, and fused onto close-packed octadecyl chains that were components of an amphiphilic terpolymer anchored onto the polyelectrolyte multilayer (PEM) by electrostatic interactions. Scanning electron microscopy (SEM) confirmed that gelatin impregnation of the graft followed by the subsequent biomimetic film coating filled in the fibril and node structure of the luminal surface of the ePTFE graft and was smooth. The lipid film displayed an initial advancing contact angle of 44 degrees , which increased to 55 degrees after being subjected to a wall shear rate of 500s(-1) for 24h at 37 degrees C in phosphate buffered saline (PBS). Fourier transform (FT-IR) spectroscopy was used to characterize the stages of biomimetic film assembly and confirmed the stability of the film under shear flow conditions. In vivo assessment using a baboon femoral arteriovenous shunt model demonstrated minimal platelet and fibrinogen deposition over a 1-h blood-contacting period. The results of this study confirm the versatility of a biomimetic film coating system by successfully transferring the methodology previously developed for planar substrates to the luminal surface of an ePTFE vascular graft.
Asunto(s)
Materiales Biomiméticos/química , Prótesis Vascular , Membranas Artificiales , Fosfolípidos/química , Politetrafluoroetileno/química , Animales , Derivación Arteriovenosa Quirúrgica , Gelatina/química , Gelatina/ultraestructura , Microscopía Electrónica de Rastreo , Papio , Fotoquímica , Espectroscopía Infrarroja por Transformada de FourierRESUMEN
Synthesis and characterization of cinnamated Type I collagen and its related mechanical properties after photomediated crosslinking were investigated in detail. Using an EDC/NHS conjugation method, collagen was chemically modified to incorporate a photosensitive cinnamate moiety. The cinnamated collagen was fully characterized by 1H NMR, UV-vis, and circular dichroism (CD) spectroscopy, as well as by rheological and mechanical analyses. Cinnamated collagens with varying degrees of derivatization retained collagen triple helical structure. The rheological spectra of collagen solutions demonstrate that the storage modulus decreases with increasing cinnamate content, owing to a decrease in physical crosslinking. The kinetics of the crosslinking process in both hydrated gels and dry films were monitored by UV-vis spectroscopy and confirmed that crosslinking was complete within 60 min of irradiation. The uniaxial stress-strain behavior of crosslinked collagen films, including Young's modulus and ultimate tensile strength, was comparable to values reported for glutaraldehyde-crosslinked monomeric collagen films. These data demonstrate that derivatization of collagen with photosensitive cinnamate moieties provides a facile route for solid-state crosslinking, thereby improving the mechanical properties of collagen and enhancing the potential applicability of collagen-based materials in tissue engineering and drug delivery.
Asunto(s)
Cinamatos/química , Cinamatos/efectos de la radiación , Colágeno Tipo I/química , Colágeno Tipo I/efectos de la radiación , Reactivos de Enlaces Cruzados/química , Fotoquímica/métodos , Materiales Biocompatibles/análisis , Materiales Biocompatibles/química , Materiales Biocompatibles/efectos de la radiación , Cinamatos/análisis , Colágeno Tipo I/análisis , Reactivos de Enlaces Cruzados/efectos de la radiación , Implantes de Medicamentos/química , Elasticidad/efectos de la radiación , Luz , Ensayo de Materiales , Resistencia al Corte , Resistencia a la Tracción/efectos de la radiación , Ingeniería de Tejidos/métodosRESUMEN
A bioinspired microhairy sensor is developed to enable ultraconformability on nonflat surfaces and significant enhancement in the signal-to-noise ratio of the retrieved signals. The device shows ≈12 times increase in the signal-to-noise ratio in the generated capacitive signals, allowing the ultraconformal microhair pressure sensors to be capable of measuring weak pulsations of internal jugular venous pulses stemming from a human neck.
Asunto(s)
Biomimética/instrumentación , Frecuencia Cardíaca , Piel , Animales , Humanos , Relación Señal-Ruido , PorcinosRESUMEN
A critical challenge in tissue regeneration is to develop constructs that effectively integrate with the host tissue. Here, we describe a composite, laser micromachined, collagen-alginate construct containing human mesenchymal stem cells (hMSCs) for tissue repair applications. Collagen type I was fashioned into laminated collagen sheets to form a mechanically robust fascia that was subsequently laser micropatterned with pores of defined dimension and spatial distribution as a means to modulate mechanical behavior and promote tissue integration. Significantly, laser micromachined patterned constructs displayed both substantially greater compliance and suture retention strength than non-patterned constructs. hMSCs were loaded in an RGD-functionalized alginate gel modified to degrade in vivo. Over a 7 day observation period in vitro, high cell viability was observed with constant levels of VEGF, PDGF-ß and MCP-1 protein expression. In a full thickness abdominal wall defect model, the composite construct prevented hernia recurrence in Wistar rats over an 8-week period with de novo tissue and vascular network formation and the absence of adhesions to underlying abdominal viscera. As compared to acellular constructs, constructs containing hMSCs displayed greater integration strength (cell seeded: 0.92 ± 0.19 N/mm vs. acellular: 0.59 ± 0.25 N/mm, p=0.01), increased vascularization (cell seeded: 2.7-2.1/hpf vs. acellular: 1.7-2.1/hpf, p<0.03), and increased infiltration of macrophages (cell seeded: 2021-3630 µm(2)/hpf vs. acellular: 1570-2530 µm(2)/hpf, p<0.05). A decrease in the ratio of M1 macrophages to total macrophages was also observed in hMSC-populated samples. Laser micromachined collagen-alginate composites containing hMSCs can be used to bridge soft tissue defects with the capacity for enhanced tissue repair and integration. STATEMENT OF SIGNIFICANCE: Effective restoration of large soft tissue defects caused by trauma or treatment complications represents a critical challenge in the clinic. In this study, a novel composite construct was engineered and evaluated for stem cell delivery and tissue repair. Laser micromachining was used to fabricate patterned, microporous constructs designed with pores of defined size and distribution as a means to tune mechanical responses, accommodate and protect incorporated cells, and enhance tissue integration. The construct was embedded within an engineered alginate gel containing hMSCs. Upon repair of a full thickness abdominal wall defect in a rat model, the composite construct modulated host innate immunity towards a reparative phenotypic response, promoted neovascularization and associated matrix production, and increased the strength of tissue integration.
Asunto(s)
Fascia/química , Regeneración Tisular Dirigida/instrumentación , Hernia/terapia , Herniorrafia/instrumentación , Trasplante de Células Madre Mesenquimatosas/instrumentación , Andamios del Tejido , Alginatos/química , Animales , Materiales Biomiméticos/síntesis química , Colágeno/química , Diseño de Equipo , Análisis de Falla de Equipo , Fascia/trasplante , Femenino , Ácido Glucurónico/química , Regeneración Tisular Dirigida/métodos , Hernia/patología , Herniorrafia/métodos , Ácidos Hexurónicos/química , Humanos , Ratas , Ratas Wistar , Ingeniería de Tejidos/instrumentación , Resultado del TratamientoRESUMEN
The unique biomechanical properties of native tissue are governed by the organization and composition of integrated collagen and elastin networks. An approach for fabricating spatially aligned, fiber-reinforced composites with adjustable collagen fiber dimensions, layouts, and distribution within an elastin-like protein matrix yielding a biocomposite with controllable mechanical responses is reported. Microtransfer molding is employed for the fabrication of hollow and solid collagen fibers with straight or crimped fiber geometries. Collagen fibers (width: 2-50 µm, thickness: 300 nm to 3 µm) exhibit a Young's modulus of 126 ± 61 MPa and an ultimate tensile strength of 7 ± 3.2 MPa. As fiber networks within composite structures, straight fiber layouts display orthotropic responses with Young's modulus ranging from 0.95 ± 0.35 to 10.4 ± 0.5 MPa and tensile strength from 0.22 ± 0.08 to 0.87 ± 0.5 MPa with increasing fraction of collagen fibers (1-10%, v/v). In contrast, composites based on crimped fiber layouts exhibit strain-dependent stiffness with an increase in Young's modulus from 0.7 ± 0.14 MPa to 3.15 ± 0.49 MPa, at a specific transition strain. Through controlling the microstructure of engineered collagen fiber networks, a facile means is established to control macroscale mechanical responses of composite protein-based materials.
Asunto(s)
Materiales Biocompatibles/química , Colágeno/química , Matriz Extracelular/química , Animales , Fenómenos Biomecánicos , Módulo de Elasticidad , Elastina/química , Escherichia coli/metabolismo , Ratas , Ratas Sprague-Dawley , Proteínas Recombinantes/metabolismo , Resistencia a la Tracción , Ingeniería de Tejidos/métodosRESUMEN
Recombinant elastin-like protein polymers are increasingly being investigated as component materials of a variety of implantable medical devices. This is chiefly a result of their favorable biological properties and the ability to tailor their physical and mechanical properties. In this report, we explore the potential of modulating the water content, mechanical properties, and drug release profiles of protein films through the selection of different crosslinking schemes and processing strategies. We find that the selection of crosslinking scheme and processing strategy has a significant influence on all aspects of protein polymer films. Significantly, utilization of a confined, fixed volume, as well as vapor-phase crosslinking strategies, decreased protein polymer equilibrium water content. Specifically, as compared to uncrosslinked protein gels, water content was reduced for genipin (15.5%), glutaraldehyde (GTA, 24.5%), GTA vapor crosslinking (31.6%), disulfide (SS, 18.2%) and SS vapor crosslinking (25.5%) (P<0.05). Distinct crosslinking strategies modulated protein polymer stiffness, strain at failure and ultimate tensile strength (UTS). In all cases, vapor-phase crosslinking produced the stiffest films with the highest UTS. Moreover, both confined, fixed volume and vapor-phase approaches influenced drug delivery rates, resulting in decreased initial drug burst and release rates as compared to solution phase crosslinking. Tailored crosslinking strategies provide an important option for modulating the physical, mechanical and drug delivery properties of protein polymers.
Asunto(s)
Reactivos de Enlaces Cruzados/farmacología , Elastina/farmacología , Células Endoteliales de la Vena Umbilical Humana/citología , Fenómenos Mecánicos/efectos de los fármacos , Sirolimus/farmacología , Disulfuros/farmacología , Sistemas de Liberación de Medicamentos , Fibronectinas/farmacología , Glutaral/farmacología , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Humanos , Iridoides/farmacología , Agua/químicaRESUMEN
Noting the abundance and importance of collagen as a biomaterial, we have developed a facile method for the production of a dense fibrillar extracellular matrix mimicking collagen-elastin hybrids with tunable mechanical properties. Through the use of excimer-laser technology, we have optimized conditions for the ablation of collagen lamellae without denaturation of protein, maintenance of fibrillar ultrastructure and preservation of native D-periodicity. Strengths of collagen-elastin hybrids ranged from 0.6 to 13 MPa, elongation at break from 9 to 70% and stiffness from 2.9 to 94 MPa, allowing for the design of a wide variety of tissue specific scaffolds. Further, large (centimeter scale) lamellae can be fabricated and embedded with recombinant elastin to generate collagen-elastin hybrids. Exposed collagen in hybrids act as cell adhesive sites for rat mesenchymal stem cells that conform to ablate waveforms. The ability to modulate these features allows for the generation of a class of biopolymers that can architecturally and physiologically replicate native tissue.
Asunto(s)
Biopolímeros/química , Colágeno/química , Ingeniería de Tejidos/métodos , Animales , Anisotropía , Materiales Biocompatibles/química , Rastreo Diferencial de Calorimetría , Adhesión Celular , Supervivencia Celular , Elastina/química , Rayos Láser , Células Madre Mesenquimatosas/citología , Nanofibras/química , Presión , Ratas , Proteínas Recombinantes/química , Estrés Mecánico , Temperatura , Tendones/químicaRESUMEN
Recombinant, elastin-like protein (ELP) polymers are of significant interest for the engineering of compliant, resilient soft tissues due to a wide range of tunable mechanical properties, biostability, and biocompatibility. Here, we enhance endothelial cell (EC) and mesenchymal stem cell compatibility with ELP constructs by addition of fibronectin (Fn) to the surface or bulk of ELP hydrogels. We find that cell adhesion, proliferation, and migration can be modulated by Fn addition. Adsorption of Fn to the hydrogel surface is more efficient than bulk blending. Surface immobilization of Fn by genipin crosslinking leads to stability without loss of bioactivity. Gels of varying mechanical modulus do not alter cell adhesion, proliferation, and migration in the range we investigate. However, more compliant gels promote an EC morphology suggesting tubulogenesis or network formation, whereas stiffer gels promote cobblestone morphology. Multilayer structures consisting of thin ELP sheets reinforced with collagen microfiber are fabricated and laminated through the culture of MSCs at layer interfaces. High cell viability in the resulting three-dimensional constructs suggests the applicability of Fn to the design of strong, resilient artificial blood vessels and other soft tissue replacements.
Asunto(s)
Materiales Biocompatibles/síntesis química , Elastina/química , Fibronectinas/química , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Animales , Vasos Sanguíneos , Adhesión Celular , Movimiento Celular , Proliferación Celular , Colágeno/química , Células Endoteliales/fisiología , Matriz Extracelular/fisiología , Técnica del Anticuerpo Fluorescente , Hidrogeles , Fenómenos Mecánicos , Células Madre Mesenquimatosas , PorcinosRESUMEN
Through the use of mechanical reinforcement of collagen matrices, mechanically strong and compliant 3D tissue mimetic scaffolds can be generated that act as scaffolds for soft tissue engineering. Collagen has been widely used for the development of materials for repair, augmentation or replacement of damaged or diseased tissue. Herein we describe a facile method for the layer-by-layer fabrication of robust planar collagen fiber constructs. Collagen gels cast in a phosphate buffer were dried to form dense collagen mats. Subsequent gels were layered and dried atop mats to create multilayer constructs possessing a range of tunable strengths (0.5 - 11 MPa) and stiffness (1 - 115 MPa). Depending on processing conditions and crosslinking of constructs, strain to failure ranged between 9 to 48%. Collagen mats were constructed into hernia patches that prevented hernia recurrence in Wistar rats.
RESUMEN
Tissue-engineered vascular grafts require long fabrication times, in part due to the requirement of cells from a variety of cell sources to produce a robust, load-bearing extracellular matrix. Herein, we propose a design strategy for the fabrication of tubular conduits comprising collagen fiber networks and elastin-like protein polymers to mimic native tissue structure and function. Dense fibrillar collagen networks exhibited an ultimate tensile strength (UTS) of 0.71±0.06 MPa, strain to failure of 37.1±2.2% and Young's modulus of 2.09±0.42 MPa, comparing favorably to a UTS and a Young's modulus for native blood vessels of 1.4-11.1 MPa and 1.5±0.3 MPa, respectively. Resilience, a measure of recovered energy during unloading of matrices, demonstrated that 58.9±4.4% of the energy was recovered during loading-unloading cycles. Rapid fabrication of multilayer tubular conduits with maintenance of native collagen ultrastructure was achieved with internal diameters ranging between 1 and 4mm. Compliance and burst pressures exceeded 2.7±0.3%/100 mmHg and 830±131 mmHg, respectively, with a significant reduction in observed platelet adherence as compared to expanded polytetrafluoroethylene (ePTFE; 6.8±0.05×10(5) vs. 62±0.05×10(5) platelets mm(-2), p<0.01). Using a rat aortic interposition model, early in vivo responses were evaluated at 2 weeks via Doppler ultrasound and CT angiography with immunohistochemistry confirming a limited early inflammatory response (n=8). Engineered collagen-elastin composites represent a promising strategy for fabricating synthetic tissues with defined extracellular matrix content, composition and architecture.
Asunto(s)
Aorta/citología , Aorta/cirugía , Prótesis Vascular , Colágeno Tipo I/química , Elastina/química , Nanofibras/química , Ingeniería de Tejidos/instrumentación , Animales , Bioprótesis , Sistema Libre de Células , Módulo de Elasticidad , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Nanofibras/ultraestructura , Ratas , Ratas Sprague-Dawley , Estrés Mecánico , Resistencia a la TracciónRESUMEN
Biosynthetic strategies for the production of recombinant elastin-like protein (ELP) triblock copolymers have resulted in elastomeric protein hydrogels, formed through rapid physical crosslinking upon warming of concentrated solutions. However, the strength of physically crosslinked networks can be limited, and options for non-toxic chemical crosslinking of these networks are not optimal. In this report, we modify two recombinant elastin-like proteins with aldehyde and hydrazide functionalities. When combined, these modified recombinant proteins self-crosslink through hydrazone bonding without requiring initiators or producing by-products. Crosslinked materials are evaluated for water content and swelling upon hydration, and subject to tensile and compressive mechanical tests. Hydrazone crosslinking is a viable method for increasing the mechanical strength of elastin-like protein polymers, in a manner that is likely to lend itself to the biocompatible in situ formation of chemically and physically crosslinked ELP hydrogels.
Asunto(s)
Reactivos de Enlaces Cruzados/química , Elastina/química , Hidrazonas/química , Hidrogeles/química , Ensayo de Materiales , Animales , Fuerza Compresiva , Humanos , Proteínas Recombinantes/químicaRESUMEN
Recombinant elastin-like protein (ELP) polymers display several favorable characteristics for tissue repair and replacement as well as drug delivery applications. However, these materials are derived from peptide sequences that do not lend themselves to cell adhesion, migration, or proliferation. This report describes the chemoselective ligation of peptide linkers bearing the bioactive RGD sequence to the surface of ELP hydrogels. Initially, cystamine is conjugated to ELP, followed by the temperature-driven formation of elastomeric ELP hydrogels. Cystamine reduction produces reactive thiols that are coupled to the RGD peptide linker via a terminal maleimide group. Investigations into the behavior of endothelial cells and mesenchymal stem cells on the RGD-modified ELP hydrogel surface reveal significantly enhanced attachment, spreading, migration and proliferation. Attached endothelial cells display a quiescent phenotype.
Asunto(s)
Materiales Biocompatibles/metabolismo , Elastina/metabolismo , Maleimidas/metabolismo , Péptidos/metabolismo , Compuestos de Sulfhidrilo/metabolismo , Secuencia de Aminoácidos , Animales , Materiales Biocompatibles/farmacología , Adhesión Celular/efectos de los fármacos , Movimiento Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Células Cultivadas , Células Endoteliales de la Vena Umbilical Humana/citología , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato/farmacología , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/metabolismo , Microscopía Confocal , Datos de Secuencia Molecular , Oligopéptidos/farmacología , Péptidos/química , Péptidos/farmacología , Sus scrofaRESUMEN
Ischemic heart disease is a leading cause of death, with few options to retain ventricular function following myocardial infarction. Hematopoietic-derived progenitor cells contribute to angiogenesis and tissue repair following ischemia reperfusion injury. Motivated by the role of bone marrow extracellular matrix (BM-ECM) in supporting the proliferation and regulation of these cell populations, we investigated BM-ECM injection in myocardial repair. In BM-ECM isolated from porcine sternum, we identified several factors important for myocardial healing, including vascular endothelial growth factor, basic fibroblast growth factor-2, and platelet-derived growth factor-BB. We further determined that BM-ECM serves as an adhesive substrate for endothelial cell proliferation. Bone marrow ECM was injected in a rat model of myocardial infarction, with and without a methylcellulose carrier gel. After one day, reduced infarct area was noted in rats receiving BM-ECM injection. After seven days we observed improved fractional shortening, decreased apoptosis, and significantly lower macrophage counts in the infarct border. Improvements in fractional shortening, sustained through 21 days, as well as decreased fibrotic area, enhanced angiogenesis, and greater c-kit-positive cell presence were associated with BM-ECM injection. Notably, the concentrations of BM-ECM growth factors were 10(3)-10(8) fold lower than typically required to achieve a beneficial effect, as reported in pre-clinical studies that have administered single growth factors alone.
Asunto(s)
Médula Ósea/metabolismo , Matriz Extracelular/metabolismo , Pruebas de Función Cardíaca , Isquemia Miocárdica/fisiopatología , Animales , Apoptosis , Células de la Médula Ósea/citología , Adhesión Celular , Proliferación Celular , Células Endoteliales de la Vena Umbilical Humana , Humanos , Masculino , Metilcelulosa/química , Isquemia Miocárdica/terapia , Ratas , Ratas Sprague-Dawley , Reología , Trasplante de Células Madre , Sus scrofaRESUMEN
Vascular disease results in the decreased utility and decreased availability of autologus vascular tissue for small diameter (< 6 mm) vessel replacements. While synthetic polymer alternatives to date have failed to meet the performance of autogenous conduits, tissue-engineered replacement vessels represent an ideal solution to this clinical problem. Ongoing progress requires combined approaches from biomaterials science, cell biology, and translational medicine to develop feasible solutions with the requisite mechanical support, a non-fouling surface for blood flow, and tissue regeneration. Over the past two decades interest in blood vessel tissue engineering has soared on a global scale, resulting in the first clinical implants of multiple technologies, steady progress with several other systems, and critical lessons-learned. This review will highlight the current inadequacies of autologus and synthetic grafts, the engineering requirements for implantation of tissue-engineered grafts, and the current status of tissue-engineered blood vessel research.
RESUMEN
Artificial composites designed to mimic the structure and properties of native extracellular matrix may lead to acellular materials for soft tissue repair and replacement, which display mechanical strength, stiffness, and resilience resembling native tissue. We describe the fabrication of thin lamellae consisting of continuous collagen microfiber embedded at controlled orientations and densities in a recombinant elastin-like protein polymer matrix. Multilamellar stacking affords flexible, protein-based composite sheets whose properties are dependent upon both the elastomeric matrix and collagen content and organization. Sheets are produced with properties that range over 13-fold in elongation to break (23-314%), six-fold in Young's modulus (5.3-33.1 MPa), and more than two-fold in tensile strength (1.85-4.08 MPa), exceeding that of a number of native human tissues, including urinary bladder, pulmonary artery, and aorta. A sheet approximating the mechanical response of human abdominal wall fascia is investigated as a fascial substitute for ventral hernia repair. Protein-based composite patches prevent hernia recurrence in Wistar rats over an 8-week period with new tissue formation and sustained structural integrity.
Asunto(s)
Colágeno/química , Elastina/química , Regeneración Tisular Dirigida/métodos , Andamios del Tejido/química , Pared Abdominal/patología , Pared Abdominal/cirugía , Animales , Materiales Biocompatibles/química , Dermis/trasplante , Módulo de Elasticidad , Elastina/genética , Humanos , Masculino , Microscopía Electrónica de Rastreo , Microscopía Electrónica de Transmisión , Ingeniería de Proteínas , Ratas , Ratas Wistar , Proteínas Recombinantes/genética , Resistencia a la TracciónRESUMEN
Collagen and elastin networks contribute to highly specialized biomechanical responses in numerous tissues and species. Biomechanical properties such as modulus, elasticity, and strength ultimately affect tissue function and durability, as well as local cellular behavior. In the case of vascular bypass grafts, compliance at physiologic pressures is correlated with increased patency due to a reduction in anastomotic intimal hyperplasia. In this report, we combine extracellular matrix (ECM) protein analogues to yield multilamellar vascular grafts comprised of a recombinant elastin-like protein matrix reinforced with synthetic collagen microfibers. Structural analysis revealed that the fabrication scheme permits a range of fiber orientations and volume fractions, leading to tunable mechanical properties. Burst strengths of 239-2760 mm Hg, compliances of 2.8-8.4%/100 mm Hg, and suture retention strengths of 35-192 gf were observed. The design most closely approximating all target criteria displayed a burst strength of 1483 +/- 143 mm Hg, a compliance of 5.1 +/- 0.8%/100 mm Hg, and a suture retention strength of 173 +/- 4 gf. These results indicate that through incorporation of reinforcing collagen microfibers, recombinant elastomeric protein-based biomaterials can play a significant role in load bearing tissue substitutes. We believe that similar composites can be incorporated into tissue engineering schemes that seek to integrate cells within the structure, prior to or after implantation in vivo.
Asunto(s)
Materiales Biocompatibles/química , Prótesis Vascular , Colágeno/química , Elastina/química , Proteínas de la Matriz Extracelular/química , Proteínas Recombinantes/química , Materiales Biocompatibles/metabolismo , Fenómenos Biomecánicos , Colágeno/síntesis química , Elastina/genética , Elastina/metabolismo , Proteínas de la Matriz Extracelular/genética , Proteínas de la Matriz Extracelular/metabolismo , Microscopía Electrónica de Rastreo , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Ingeniería de Tejidos/métodosRESUMEN
The universal structural role of collagen fiber networks has motivated the development of collagen gels, films, coatings, injectables, and other formulations. However, reported synthetic collagen fiber fabrication schemes have either culminated in short, discontinuous fiber segments at unsuitably low production rates, or have incompletely replicated the internal fibrillar structure that dictates fiber mechanical and biological properties. We report a continuous extrusion system with an off-line phosphate buffer incubation step for the manufacture of synthetic collagen fiber. Fiber with a cross-section of 53+ or - 14 by 21 + or - 3 microm and an ultimate tensile strength of 94 + or - 19 MPa was continuously produced at 60 m/hr from an ultrafiltered monomeric collagen solution. The effect of collagen solution concentration, flow rate, and spinneret size on fiber size was investigated. The fiber was further characterized by microdifferential scanning calorimetry, transmission electron microscopy (TEM), second harmonic generation (SHG) analysis, and in a subcutaneous murine implant model. Calorimetry demonstrated stabilization of the collagen triple helical structure, while TEM and SHG revealed a dense, axially aligned D-periodic fibril structure throughout the fiber cross-section. Implantation of glutaraldehyde crosslinked and noncrosslinked fiber in the subcutaneous tissue of mice demonstrated limited inflammatory response and biodegradation after a 6-week implant period.
Asunto(s)
Materiales Biocompatibles/química , Materiales Biocompatibles/síntesis química , Colágenos Fibrilares/química , Colágenos Fibrilares/síntesis química , Animales , Fenómenos Biomecánicos , Rastreo Diferencial de Calorimetría , Reactivos de Enlaces Cruzados , Colágenos Fibrilares/ultraestructura , Glutaral , Masculino , Ensayo de Materiales , Ratones , Ratones Endogámicos C57BL , Microscopía Electrónica de Transmisión , Estructura Molecular , Prótesis e Implantes , Multimerización de Proteína , Ratas , Resistencia a la TracciónRESUMEN
Electrospinning was employed to fabricate 3-D fiber networks from a recombinant amphiphilic elastin-mimetic tri-block protein polymer and the effects of moderate thermal conditioning (60 degrees C, 4 h) on network mechanical responses investigated. Significantly, while cryo-high resolution scanning electron microscopy (cryo-HRSEM) revealed that the macroscopic and microscopic morphology of the network structure was unchanged, solid-state (1)H-NMR spectroscopy demonstrated enhanced interphase mixing of hydrophobic and hydrophilic blocks. Significantly, thermal annealing triggered permanent changes in network swelling behavior (28.75 +/- 2.80 non-annealed vs. 13.55 +/- 1.39 annealed; P < 0.05) and uniaxial mechanical responses, including Young's modulus (0.170 +/- 0.010 MPa non-annealed vs. 0.366 +/- 0.05 MPa annealed; P < 0.05) and ultimate tensile strength (0.079 +/- 0.008 MPa vs. 0.119 +/- 0.015 MPa; P < 0.05). To our knowledge, these investigations are the first to note that mechanical responses of protein polymers can be permanently altered through a temperature-induced change in microphase mixing.
Asunto(s)
Proteínas/química , Materiales Biocompatibles/química , Elastina/química , Espectroscopía de Resonancia Magnética , Ensayo de Materiales , Polímeros/síntesis química , Polímeros/química , Proteínas Recombinantes/química , Propiedades de Superficie , Temperatura , Resistencia a la TracciónRESUMEN
Noncoronary atherosclerotic vascular disease, including symptomatic lower extremity peripheral arterial disease (PAD), promises to extract a steadily rising medical and economic toll over the coming decades. Although drug-eluting stents have led to substantial advances in the management of coronary atherosclerosis, endovascular treatment of noncoronary, peripheral arterial lesions continues to yield high restenosis rates and early clinical failures. In this report, we review recent developments in microfabrication and nanotechnology strategies that offer new opportunities for improving stent-based technology for the treatment of more extensive and complex lesions. In this regard, stents with microfabricated reservoirs for controlled temporal and spatial drug release have already been successfully applied to coronary lesions. Microfabricated needles to pierce lesions and deliver therapeutics deep within the vascular wall represent an additional microscale approach. At the nanoscale, investigators have primarily sought to alter the strut surface texture or coat the stent to enhance inductive or conductive schemes for endothelialization and host artery integration. Nanotechnology research that identifies promising strategies to limit restenosis through targeted drug delivery after angioplasty and stenting is also reviewed.