Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Small ; : e2402988, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38982943

RESUMEN

Zero-excess Li-metal batteries (ZE-LMBs) have emerged as the ultimate battery platform, offering an exceptionally high energy density. However, the absence of Li-hosting materials results in uncontrolled dendritic Li deposition on the Cu current collector, leading to chronic loss of Li inventory and severe electrolyte decomposition, limiting its full utilization upon cycling. This study presents the application of ultrathin (≈50 nm) coatings comprising six metallic layers (Cu, Ag, Au, Pt, W, and Fe) on Cu substrates in order to provide insights into the design of Li-depositing current collectors for stable ZE-LMB operation. In contrast to non-alloy Cu, W, and Fe coatings, Ag, Au, and Pt coatings can enhance surface lithiophilicity, effectively suppressing Li dendrite growth, thereby improving Li reversibility. Considering the distinct Li-alloying behaviors, particularly solid-solution and/or intermetallic phase formation, Pt-coated Cu current collectors maintain surface lithiophilicity over repeated Li plating/stripping cycles by preserving the original coating layer, thereby attaining better cycling performance of ZE-LMBs. This highlights the importance of selecting suitable Li-alloy metals to sustain surface lithiophilicity throughout cycling to regulate dendrite-less Li plating and improve the electrochemical stability of ZE-LMBs.

2.
Jpn J Clin Oncol ; 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711392

RESUMEN

BACKGROUND: The incidence and risk factors of peripherally inserted central catheter-related thrombosis in patients with breast cancer have not been fully elucidated. METHOD: Meta-analysis was performed by searching all studies on the incidence of peripherally inserted central catheter-associated thrombosis and risk factors for its formation in breast cancer patients from the establishment of the database to May 2023, including PubMed, Embase, Web of Science, China Knowledge Network, China Biomedical Literature Service System (SinoMed) and Wanfang databases. Then the incidence of peripherally inserted central catheter-related thrombosis and risk factors for its formation were analyzed in breast cancer patients. RESULTS: A total of 15 articles were included, involving 8635 patients. The total incidence of peripherally inserted central catheter-related thrombosis in breast cancer patients was 7.0% (95% confidence interval: 4.0-13.0%) and 12.9% (95% confidence interval: 7.0-22.5%) after correction. Thirty-two risk factors were included, and eight risk factors could be combined. Among these risk factors, there were statistically significant differences (P < 0.05) in body mass index ≥ 25 (odds ratio = 6.319, 95% confidence interval: 2.733-14.613; P < 0.001), D-dimer >500 ng/ml (odds ratio = 1.436, 95% confidence interval: 1.113-1.854; P = 0.005), increased fibrinogen (odds ratio = 4.733, 95% confidence interval: 1.562-14.346; P = 0.006), elevated platelet count (odds ratio = 4.134, 95% confidence interval: 2.694-6.346; P < 0.001) and catheter malposition (odds ratio = 8.475, 95% confidence interval: 2.761-26.011; P < 0.001). CONCLUSION: The incidence rate of peripherally inserted central catheter-related thrombosis in breast cancer patients was 7.0% (95% confidence interval: 4.0-13.0%). Body mass index ≥ 25, D-dimer >500 ng/ml, elevated fibrinogen, elevated platelet count and catheter malposition were risk factors for peripherally inserted central catheter-related thrombosis in breast cancer patients.

3.
Sci Rep ; 14(1): 17026, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39043821

RESUMEN

Electroadhesive forces are crucial in various applications, including grasping devices, electro-sticky boards, electrostatic levitation, and climbing robots. However, the design of electroadhesive devices relies on speculative or empirical error approaches. Therefore, we present a theoretical model comprising predictive coplanar electrodes and protective layers for analyzing the electrostatic fields between an object and electroadhesive device. The model considers the role of protective layer and the air gap between the electrode surface and the object. To exert a higher electroadhesive force, the higher permeability of the protective layer is required. However, a high permeability of the protective layer is hard to withstand high applied voltage. To overcome this, two materials with different permeabilities were employed as protective layers-a low-permeability inner layer and a high-permeability outer layer-to maintain a high voltage and generate a large electroadhesive force. Because a low-permeability inner layer material was selected, a more permeable outer layer material was considered. A theoretical analysis revealed complex relationships between various design parameters. The impact of key design parameters and working environments on the electroadhesion behavior was further investigated. This study reveals the fundamental principles of electroadhesion and proposes prospective methods to enhance the design of electroadhesive devices for various engineering applications.

4.
Small Methods ; 7(11): e2300748, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37712206

RESUMEN

With the growing popularity of Li-ion batteries in large-scale applications, building a safer battery has become a common goal of the battery community. Although the small errors inside the cells trigger catastrophic failures, tracing them and distinguishing cell failure modes without knowledge of cell anatomy can be challenging using conventional methods. In this study, a real-time, non-invasive magnetic field imaging (MFI) analysis that can signal the battery current-induced magnetic field and visualize the current flow within Li-ion cells is developed. A high-speed, spatially resolved MFI scan is used to derive the current distribution pattern from cells with different tab positions at a current load. Current maps are collected to determine possible cell failures using fault-simulated batteries that intentionally possess manufacturing faults such as lead-tab connection failures, electrode misalignment, and stacking faults (electrode folding). A modified MFI analysis exploiting the magnetic field interference with the countercurrent-carrying plate enables the direct identification of defect spots where abnormal current flow occurs within the pouch cells.

5.
Sci Rep ; 12(1): 3540, 2022 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-35241755

RESUMEN

The organizational principles of the community architecture of human brain networks are still mostly unknown. Here, we found that brain networks have a moderate degree of community segregation but are specifically organized to achieve high community overlap while maintaining their segregated community structures. These properties are distinct from other real-world complex networks. Additionally, we found that human subjects with a higher degree of community overlap in their brain networks show greater dynamic reconfiguration and cognitive flexibility.


Asunto(s)
Encéfalo , Red Nerviosa , Encéfalo/fisiología , Mapeo Encefálico/métodos , Humanos , Imagen por Resonancia Magnética
6.
Nat Commun ; 12(1): 280, 2021 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-33436582

RESUMEN

Developing effective drugs for Alzheimer's disease (AD), the most common cause of dementia, has been difficult because of complicated pathogenesis. Here, we report an efficient, network-based drug-screening platform developed by integrating mathematical modeling and the pathological features of AD with human iPSC-derived cerebral organoids (iCOs), including CRISPR-Cas9-edited isogenic lines. We use 1300 organoids from 11 participants to build a high-content screening (HCS) system and test blood-brain barrier-permeable FDA-approved drugs. Our study provides a strategy for precision medicine through the convergence of mathematical modeling and a miniature pathological brain model using iCOs.


Asunto(s)
Enfermedad de Alzheimer/tratamiento farmacológico , Enfermedad de Alzheimer/patología , Encéfalo/patología , Evaluación Preclínica de Medicamentos , Redes Reguladoras de Genes , Organoides/patología , Enfermedad de Alzheimer/genética , Cinamatos/farmacología , Cinamatos/uso terapéutico , Redes Reguladoras de Genes/efectos de los fármacos , Ensayos Analíticos de Alto Rendimiento , Humanos , Células Madre Pluripotentes Inducidas/metabolismo , Modelos Biológicos , Reproducibilidad de los Resultados , Factores de Riesgo
7.
iScience ; 13: 154-162, 2019 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-30844695

RESUMEN

The brain controls various cognitive functions in a robust and efficient way. What is the control architecture of brain networks that enables such robust and optimal control? Is this brain control architecture distinct from that of other complex networks? Here, we developed a framework to delineate a control architecture of a complex network that is compatible with the behavior of the network and applied the framework to structural brain networks and other complex networks. As a result, we revealed that the brain networks have a distributed and overlapping control architecture governed by a small number of control nodes, which may be responsible for the robust and efficient brain functions. Moreover, our artificial network evolution analysis showed that the distributed and overlapping control architecture of the brain network emerges when it evolves toward increasing both robustness and efficiency.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA