Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Shoulder Elbow Surg ; 33(5): 1004-1016, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38286183

RESUMEN

BACKGROUND: Previously, we reported early (2-year) findings from a randomized controlled trial comparing a second-generation uncemented trabecular metal-backed (TM) glenoid vs. cemented polyethylene glenoid (POLY) in patients undergoing a total shoulder arthroplasty. The purpose of the current study is to report disease-specific quality of life, clinical, patient-reported, and radiographic outcomes at midterm (5-year) from this trial. METHODS: Five surgeons from 3 centers participated. Patients 18-79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Randomization to an uncemented TM or cemented POLY glenoid was performed intra-operatively after adequate bone stock was confirmed. Study intervals were baseline, 2- and 5-year postoperative. The primary outcome was the Western Ontario Osteoarthritis Shoulder (WOOS) quality of life score. Secondary outcomes included the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, EuroQol-5 Dimensions, and 12-Item Short Form Health Survey scores and clinical and radiographic examinations. Radiographic images were reviewed for metal debris according to Endrizzi. Mixed effects repeated measures analysis of variance for within- and between-group comparisons were performed. RESULTS: Of the 104 patients who consented, 93 were randomized (46 TM; 47 POLY). There were no differences between groups at baseline (TM: mean age 66.5 years [standard deviation (SD) 6.4], 24 male and 22 female; and POLY: mean age 68.4 years [SD 5.5], 23 male / 24 female). Mean (SD) WOOS scores at baseline and 2 and 5 years were as follows: TM, 32 (21), 92 (13), and 93 (11); POLY, 27 (15), 93 (11), and 93 (10), respectively. No statistical or clinically relevant differences were noted with patient-reported outcomes between groups. Metal debris was observed in 11 (23.9%) patients, but outcomes were not negatively impacted, and debris severity was minor (grades 1 and 2). Complication rates were similar between groups (TM: 7 of 46 [15.2%], and POLY: 8 of 47 [17.0%]; P = .813). No aseptic glenoid failures were reported, but 1 patient in the TM group required revision because of infection. CONCLUSIONS: Our short-term (2-year) findings were maintained with longer follow-up. At 5 years postoperation, there were no statistically or clinically significant differences between an uncemented second-generation TM glenoid and a cemented polyethylene glenoid with respect to disease-specific quality of life or patient-reported outcomes. No glenoid implant failures were reported, and complication rates were similar between groups. Only one complication was glenoid related (1 infection in the TM group). Metal debris was observed in 23.9% of patients with a TM glenoid but did not negatively influence implant survival, patient-reported outcomes, or shoulder function.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Prótesis Articulares , Osteoartritis , Articulación del Hombro , Humanos , Masculino , Femenino , Anciano , Artroplastía de Reemplazo de Hombro/métodos , Polietileno , Artroplastia de Reemplazo/métodos , Calidad de Vida , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento , Osteoartritis/diagnóstico por imagen , Osteoartritis/cirugía , Metales , Diseño de Prótesis , Estudios de Seguimiento , Estudios Retrospectivos
2.
Microsurgery ; 41(8): 709-715, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34533855

RESUMEN

BACKGROUND: Post-mastectomy free-flap breast reconstruction is becoming increasingly common in the United States. However, predicting which patients may suffer complications remains challenging. We sought to apply the validated modified frailty index (mFI) to free-flap breast reconstruction in breast cancer patients and determine its utility in predicting negative outcomes. METHODS: We conducted a retrospective study using National Surgical Quality Improvement Project (NSQIP). All patients who had a CPT code of 19364, indicative of free tissue transfer for breast cancer reconstruction, were included. Data on preoperative characteristics and postoperative outcomes were collected. Patients were separated based on the number of mFI factors present into three categories: 0, 1, and > 2 factors. Preoperative demographics, clinical status, and other comorbidities were also studied. Negative outcomes were compared using multivariate logistic regression. RESULTS: 11,852 patients (mean age 50.9 ± 9.5) were found; 24.2% had complications, comparable to previous literature. mFI is predictive of all types of negative outcomes. 22.5% of all patients with 0 mFI, 27.7% of patients with 1 mFI and 34.2% of patients with at least two mFI had a negative outcome. The most common factors contributing to the mFI were history of hypertension (24.8%) and diabetes (6.1%). mFI was found to be an isolated risk factor for negative outcomes, along with steroid use, American Society of Anesthesiology (ASA) classification, body mass index, and immediate, and bilateral operations. CONCLUSIONS: This NSQIP-based study for patients undergoing free flap breast reconstruction shows that the mFI holds predictive value regarding negative outcomes. This provides more information to properly counsel patients before free flap breast reconstruction surgery.


Asunto(s)
Fragilidad , Mamoplastia , Adulto , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Mejoramiento de la Calidad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Estados Unidos/epidemiología
3.
J Craniofac Surg ; 32(4): 1413-1416, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34842403

RESUMEN

PURPOSE: Safety-net hospitals (SNHs) are vital in the care of trauma populations, but little is known about the burden of facial trauma presenting to SNHs. The authors sought to characterize the presentation and treatment of facial fractures across SNHs and determine the association between SNH care and healthcare utilization in patients undergoing fracture repair. METHODS: Adult patients presenting with a facial fracture as their primary admitting diagnosis from the year 2012 to 2015 were identified in the National Inpatient Sample. The "safety-net burden" of each hospital was defined based on the proportion of Medicaid and self-pay discharges. Patient factors analyzed were sex, race, age, income level, insurance status, fracture location, and comorbidities. Hospital factors analyzed were safety-net burden, teaching status, geographic region, bed size, and ownership status. The main outcomes were length of stay (LOS), hospital costs, time to repair, and postoperative complications. RESULTS: Of 78,730 patients, 27,080 (34.4%) were treated at SNHs and 24,844 (31.6%) were treated at non-SNHs. Compared to non-SNHs, patients treated at SNHs were more likely to undergo operative repair at SNHs (65.8% versus 53.9%, P < 0.001). Overall mean LOS was comparable between non-SNH and SNH (3.43 versus 3.38 days, P = 0.611), as was mean hospital cost ($15,487 versus $15,169, P = 0.434). On multivariate linear regression, safety-net status was not a predictor of increased LOS, cost, or complications. However, safety-net status was significantly associated with lower odds of undergoing repair within 48 hours of admission (odds ratio 0.783, 95% confidence interval = 0.680-0.900, P = 0.001). CONCLUSIONS: Safety-net hospitals are able to treat facial trauma patients with greater injury burden and lower socioeconomic resources without increased healthcare utilization. Healthcare reform must address the financial challenges that endanger these institutions to ensure timely treatment of all patients.


Asunto(s)
Pacientes Internos , Proveedores de Redes de Seguridad , Adulto , Hospitales , Humanos , Tiempo de Internación , Medicaid , Estados Unidos/epidemiología
4.
Eur J Nucl Med Mol Imaging ; 40(8): 1283-91, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23674205

RESUMEN

Integration of optical imaging technologies can further strengthen the field of radioguided surgery. Rather than using two separate chemical entities to achieve this extension, hybrid imaging agents can be used that contain both radionuclear and optical properties. Two types of such hybrid imaging agents are available: (1) hybrid imaging agents generated by Cerenkov luminescence imaging (CLI) of ß-emitters and (2) hybrid imaging agents that contain both a radioactive moiety and a fluorescent dye. One major challenge clinicians are now facing is to determine the potential value of these approaches. With this tutorial review we intend to clarify the differences between the two approaches and highlight the clinical potential of hybrid imaging during image-guided surgery applications.


Asunto(s)
Mediciones Luminiscentes/métodos , Imagen Multimodal/métodos , Medicina Nuclear/métodos , Imagen Óptica/métodos , Tomografía de Emisión de Positrones , Colorantes Fluorescentes , Humanos , Imagen Multimodal/instrumentación , Cirugía Asistida por Computador
5.
Nanotechnology ; 24(7): 075703, 2013 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-23358577

RESUMEN

UNLABELLED: In this work we present a detailed study on the influence of surface modifications for luminescent silver (Ag) clusters. Ag clusters (25 atoms) capped with dihydrolipoic acid show a distinct absorbance spectrum with several sharp transitions, and relative broad deep red luminescence with a quantum yield of 5% combined with a remarkably long luminescence lifetime of ~3 µs at room temperature. Both pH and the presence of coordinating ligands influence the absorbance spectra and fluorescence intensity. A strong increase in luminescence intensity up to 45% quantum yield could be induced by coordination with PEG ligands. CONCLUSION: the surface coordination of the Ag clusters strongly influences the optical properties.

6.
Sex Med ; 10(5): 100545, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35914381

RESUMEN

INTRODUCTION: Permanent genital hair removal is required before gender-affirming vaginoplasty to prevent hair-related complications. No previous studies have directly compared the relative efficacy, costs, and patient experiences with laser hair removal (LHR) vs electrolysis treatments. Food and Drug Administration (FDA) oversight of medical devices is poorly understood and commonly misrepresented, adversely affecting patient care. AIM: This study compares treatment outcomes of electrolysis and LHR for genital hair removal and investigates FDA regulation of electrolysis and LHR devices. METHODS: Penile-inversion vaginoplasty and shallow-depth vaginoplasty patients completed surveys about their preoperative hair removal, including procedure type, number/frequency of sessions, cost, and discomfort. Publicly available FDA-review documents and databases were reviewed. MAIN OUTCOMES MEASURE: Compared to electrolysis, LHR was associated with greater efficiency, decreased cost, decreased pain, and improved patient satisfaction. RESULTS: Of 52 total (44 full-depth and 8 shallow-depth) vaginoplasty patients, 22 of 52 underwent electrolysis only, 15 of 52 underwent laser only, and 15 of 52 used both techniques. Compared to patients that underwent LHR only, patients that underwent only electrolysis required a significantly greater number of treatment sessions (mean 24.3 electrolysis vs 8.1 LHR sessions, P < .01) and more frequent sessions (every 2.4 weeks for electrolysis vs 5.3 weeks for LHR, P < .01) to complete treatment (defined as absence of re-growth over 2 months). Electrolysis sessions were significantly longer than LHR sessions (152 minutes vs 26 minutes, P < .01). Total treatment costs for electrolysis ($5,161) were significantly greater than for laser ($981, P < .01). Electrolysis was associated with greater pain and significantly increased need for pretreatment analgesia, which further contributed to higher net costs for treatment with electrolysis vs laser. Many LHR and electrolysis devices have been FDA-cleared for safety, but the FDA does not assess or compare clinical efficacy or efficiency. CLINICAL IMPLICATIONS: For patients with dark-pigmented hair, providers should consider LHR as the first-line treatment option for preoperative hair removal before gender-affirming vaginoplasty. STRENGTH AND LIMITATIONS: This is the first study to compare electrolysis and LHR for genital hair removal. The discussion addresses FDA review/oversight of devices, which is commonly misrepresented. Limitations include the survey format for data collection. CONCLUSION: When compared with electrolysis, LHR showed greater treatment efficiency (shorter and fewer treatment sessions to complete treatment), less pain, greater tolerability, and lower total cost. Our data suggests that, for patients with dark genital hair, providers should consider recommending laser as the first-line treatment for permanent genital hair removal before vaginoplasty. Yuan N, Feldman A, Chin P, et al. Comparison of Permanent Hair Removal Procedures before Gender-Affirming Vaginoplasty: Why We Should Consider Laser Hair Removal as a First-Line Treatment for Patients Who Meet Criteria. Sex Med 2022;10:100545.

7.
Chembiochem ; 12(12): 1897-903, 2011 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-21739561

RESUMEN

The chemokine receptor 4 (CXCR4) is over-expressed in 23 types of cancer in which it plays a role in, among others, the metastatic spread. For this reason it is a potential biomarker for the field of diagnostic oncology. The antagonistic Ac-TZ14011 peptide, which binds to CXCR4, has been conjugated to luminescent iridium dyes to allow for CXCR4 visualization. The iridium dyes are cyclometalated octahedral iridium(III) 2-phenylpyridine complexes that can be functionalized with one, two or three targeting Ac-TZ14011 peptides. Confocal microscopy and fluorescence lifetime imaging microscopy (FLIM) showed that the peptide-iridium complex conjugates can be used to visualize CXCR4 expression in tumor cells. The CXCR4 receptor affinity and specific cell binding of the mono-, di- and trimeric peptide derivatives were assessed by using flow cytometry. The three derivatives possessed nanomolar receptor affinity and could distinguish between cell lines with different CXCR4 expression levels. This yields the first example of a neutral iridium(III) complex functionalized with peptides for FLIM-based visualization of a cancer associated membrane receptor.


Asunto(s)
Neoplasias de la Mama/metabolismo , Complejos de Coordinación/síntesis química , Colorantes Fluorescentes/síntesis química , Iridio/química , Imagen Molecular/métodos , Péptidos/metabolismo , Receptores CXCR4/metabolismo , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Complejos de Coordinación/metabolismo , Complejos de Coordinación/farmacología , Femenino , Citometría de Flujo , Colorantes Fluorescentes/metabolismo , Colorantes Fluorescentes/farmacología , Expresión Génica , Humanos , Iridio/metabolismo , Cinética , Ligandos , Luminiscencia , Microscopía Fluorescente , Péptidos/química , Unión Proteica , Piridinas/química , Receptores CXCR4/química , Receptores CXCR4/genética
8.
Bone Jt Open ; 2(9): 728-736, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34488426

RESUMEN

AIMS: To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component. METHODS: Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed. RESULTS: A total of 93 patients were randomized (46 TM; 47 POLY). No significant or clinically important differences were found with patient-reported outcomes at 24-month follow-up. Regarding the glenoid components, there were no complications or revision surgeries in either group. Grade 1 metal debris was observed in three (6.5%) patients with TM glenoids at 24 months but outcomes were not negatively impacted. CONCLUSION: Early results from this RCT showed no differences in disease-specific QOL, radiographs, complication rates, or shoulder function between uncemented second-generation TM and cemented POLY glenoids at 24 months postoperatively. Revision surgeries and reoperations were reported in both groups, but none attributed to glenoid implant failure. At 24 months postoperatively, Grade 1 metal debris was found in 6.5% of patients with a TM glenoid but did not negatively influence patient-reported outcomes. Longer-term follow-up is needed and is underway. Cite this article: Bone Jt Open 2021;2(9):728-736.

9.
J Clin Med ; 10(24)2021 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-34945069

RESUMEN

BACKGROUND: Malpositioning of the glenoid component in total shoulder arthroplasty (TSA) remains the primary source of loosening. The purpose of this study is firstly, to quantify postoperative glenoid component position in patients having a TSA and secondly, to explore whether glenoid component radiolucency is associated with glenoid position, clinical outcomes and patient-reported measures in the short-term (two year) follow-up period. METHODS: This study was a sub-study of a larger clinical trial that included patients who underwent a TSA and who were randomized into two different glenoid types with a minimum two-year follow-up period. Post-operative radiographic assessments (six weeks and two years) were used to measure glenoid component position (version, inclination, offset) and humeral head centering anterior-posterior (AP) and superior-inferior (SI), and to assess glenoid component radiolucent scoring (modified Lazarus). Pre-operative X-rays were used to measure glenoid version, inclination and Walch classification. Patient-reported measures (PROMs) included the EQ-5D health slider and the Western Ontario Osteoarthritis (WOOS) and American Shoulder and Elbow Surgeons (ASES) score and were captured at baseline and two years postoperative. Clinical outcomes including range of motion and complications were also documented. Statistical analysis included t-tests and regression modeling. RESULTS: Ninety-one patients with an average age of 69.9 ± 6.2 years were included in this study. Glenoid component position improved significantly in version (-19.4 ± 8.6° to -17.7 ± 8.5°; p < 0.045) and inclination (11.5 ± 7.1° to 5.9 ± 6.3°; p < 0.00001) from preoperative to six weeks postoperative. Glenoid component offset in SI and humeral head centering in AP remained unchanged throughout the follow-up. Radiolucency (Lazarus classification) was recorded in 21 cases (17.3%) with a Lazarus score of 1 (15 cases) and 2 (6 cases). The EQ-5D health slider, WOOS and ASES, and ROM confirmed continuous improvements from the preoperative scores to the two-year follow-up (p < 0.05). Regression models showed no correlation between glenoid component radiolucency at two years and the postoperative week six glenoid component position; however, female gender was a significant variable. CONCLUSION: Glenoid component changes from its original native glenoid were observed following TSA. Glenoid inclination was improved more than version from baseline, and the humeral head remained well-centered in AP and SI at two years. Radiolucency of the glenoid at two years is not negatively associated with PROMs or component position; however, female gender was identified as a significant predictor and warrants further investigation. Complications are not associated with glenoid position or radiolucency, but longer-term follow-up is required.

10.
Nanotechnology ; 21(48): 482001, 2010 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-21063057

RESUMEN

One clinical precedent for the use of nanosized imaging agents is the localization of the tumor draining sentinel lymph nodes. In this application, radiocolloids such as (99m)Tc-NanoColl are currently used to plan the surgical procedure and to provide acoustic guidance during the intervention. Additional injections of dyes are common to provide optical surgical guidance. Bimodal imaging agents, which are both radioactive and fluorescent, have the potential to be used for both surgical planning and intraoperative fluorescence guidance towards the sentinel lymph nodes. This review provides an overview of the radioactive, fluorescent, and size properties of (non-targeted) bimodal nanoparticles, and their (potential) value in sentinel lymph node detection.


Asunto(s)
Diagnóstico por Imagen/métodos , Cuidados Intraoperatorios/métodos , Nanopartículas , Cuidados Preoperatorios/métodos , Biopsia del Ganglio Linfático Centinela/métodos , Animales , Fluorescencia , Humanos , Radioisótopos
11.
Nanotechnology ; 21(14): 145101, 2010 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-20220222

RESUMEN

We evaluated cellular responses to polymer-treated gold nanorods, which were synthesized using the standard wet-chemistry method that utilizes hexadecyltrimethylammonium bromide (CTAB). The nanorod dispersions were coated with either polystyrene sulfonate (PSS) or polyethylene glycol (PEG). Two sizes of nanorods were tested, with optical responses peaking at 628 and 773 nm. The cells were from mammary adenocarcinoma (SKBR3), Chinese Hamster Ovary (CHO), mouse myoblast (C2C12) and Human Leukemia (HL60) cell lines. Their mitochondrial function following exposure to the nanorods were assessed using the MTS assay. We found PEGylated particles to have superior biocompatibility compared with PSS-coated nanorods, which showed substantial cytotoxicity. Electron microscopy showed no cellular uptake of PEGylated particles compared with their PSS counterparts. PEGylated gold nanorods also exhibited better dispersion stability in the presence of cell growth medium; PSS-coated rods tended to flocculate or cluster. In the case of the PSS particles, toxicity correlated with surface area across the two sizes of nanorods studied.


Asunto(s)
Oro/química , Nanotubos/química , Nanotubos/toxicidad , Polímeros/química , Animales , Apoptosis/efectos de los fármacos , Línea Celular , Supervivencia Celular/efectos de los fármacos , Medios de Cultivo/farmacología , Oro/toxicidad , Humanos , Modelos Químicos , Nanotubos/ultraestructura , Polímeros/toxicidad , Propiedades de Superficie/efectos de los fármacos
12.
Nanotechnology ; 21(35): 355101, 2010 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-20689167

RESUMEN

Specific removal of the sentinel lymph node (SLN) during breast cancer surgery presents physicians with the opportunity to detect early metastatic disease. To increase the accuracy of intraoperative SLN detection, new methods with higher sensitivity and specificity are required. We have quantitatively compared conventional preoperative lymphoscintigraphy with albumin radiocolloids ((99m)Tc-NanoColl) with optical intraoperative guidance using the near infrared dye indocyanine green (ICG) in an orthotopic mouse model for metastatic breast cancer. Furthermore, we have applied a self-assembled multimodal complex, in which ICG is non-covalently bound to the albumin radiocolloid, to attain identical dynamics of the radioactive and optical components. The SLN specificity of the multimodal complex is similar to conventional lymphoscintigraphy, while the fluorescent signal-to-noise ratio is improved by 86% compared to ICG alone. In addition, the multimodal complex permits scintigraphic validation of the fluorescent findings. The multimodal ICG-(99m)Tc-NanoColl complex can be used both for lymphoscintigraphy by preoperative single photon emission computed tomography/computed tomography and for surgical navigation by intraoperative fluorescence imaging.


Asunto(s)
Ganglios Linfáticos/diagnóstico por imagen , Neoplasias Mamarias Experimentales/diagnóstico por imagen , Cintigrafía/métodos , Biopsia del Ganglio Linfático Centinela/métodos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Tomografía Computarizada de Emisión de Fotón Único/métodos , Animales , Femenino , Ganglios Linfáticos/metabolismo , Neoplasias Mamarias Experimentales/patología , Neoplasias Mamarias Experimentales/cirugía , Ratones , Reproducibilidad de los Resultados , Agregado de Albúmina Marcado con Tecnecio Tc 99m/farmacocinética , Imagen de Cuerpo Entero/métodos
13.
Endocr Pathol ; 31(4): 377-384, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32671653

RESUMEN

The ThyroSeq next-generation sequencing test refines the risk of malignancy in cytologically indeterminate thyroid nodules. Specific genetic alterations have distinct cancer probabilities and clinical phenotypes. There is limited data on the association between specific genetic alterations and histopathologic features. The aim of this study was to evaluate specific ThyroSeq alterations in prognosticating high-risk histopathologic characteristics. We performed a retrospective single-institution study of all patients diagnosed with indeterminate thyroid nodules (May 2016-December 2019) who had a mutation identified with ThyroSeq v2 or v3 and underwent surgical resection. Specific genetic alterations were correlated with surgical histopathology. The main outcomes were risk of malignancy and structural recurrence risk based on histopathologic features and the 2015 American Thyroid Association (ATA) risk stratification. Of the 78 nodules, 50 (64%) were thyroid cancer or noninvasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) on surgical histopathology. Nodules with high-risk TERT or TP53 combination mutations (TERT/TP53) and those with BRAF-like mutations were associated with a 100% probability of cancer and higher rates of extrathyroidal extension and regional nodal involvement than nodules with RAS-like mutations. Among nodules with RAS-like mutations, there was an even distribution between benign, NIFTP, and malignant results, the latter of which were all ATA low risk for structural disease recurrence. Overall, TERT/TP53 and BRAF-like ThyroSeq mutations are associated with an increased cancer probability and risk of recurrence defined by histopathologic features, while RAS-like mutations are associated with lower cancer probability and indolent disease. Individualized management, including extent of surgery, should be considered based on specific genetic alterations found in cytologically indeterminate thyroid nodules.


Asunto(s)
Nódulo Tiroideo/diagnóstico , Nódulo Tiroideo/genética , Nódulo Tiroideo/patología , Adenocarcinoma Folicular/diagnóstico , Adenocarcinoma Folicular/genética , Adenocarcinoma Folicular/patología , Adulto , Anciano , Estudios de Cohortes , Femenino , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Masculino , Persona de Mediana Edad , Mutación , Estudios Retrospectivos , Análisis de Secuencia de ADN/métodos
14.
Angiogenesis ; 12(1): 17-24, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19067197

RESUMEN

Molecular imaging of angiogenesis is urgently needed for diagnostic purposes such as early detection, monitoring of (angiostatic) therapy and individualized therapy. Multimodality molecular imaging is a promising and refined technique to study tumor angiogenesis, which has so far been largely unexplored due to the lack of suitable multimodal contrast agents. Here, we report on the application of a novel alphavbeta3-specific quantum dot-based nanoparticle, which has been optimized for both optical and magnetic resonance detection of tumor angiogenesis. Upon intravenous injection of RGD-pQDs in tumor-bearing mice, intravital microscopy allowed the detection of angiogenically activated endothelium at cellular resolution with a small scanning window and limited penetration depth, while magnetic resonance imaging was used to visualize angiogenesis at anatomical resolution throughout the entire tumor. Fluorescence imaging allowed whole-body investigation of angiogenic activity. Using these quantum dots and the aforementioned imaging modalities, the angiogenic tumor vasculature was readily detected with the highest angiogenic activity occurring in the periphery of the tumor. This nanoparticle may be employed for multimodality imaging of a variety of diseases that are accompanied by activation of endothelial cells. Furthermore, the current technology might be developed for molecular imaging of other pathophysiological processes.


Asunto(s)
Diagnóstico por Imagen , Integrina alfaVbeta3/metabolismo , Neoplasias/irrigación sanguínea , Neovascularización Patológica/metabolismo , Puntos Cuánticos , Animales , Pollos , Membrana Corioalantoides/irrigación sanguínea , Imagen por Resonancia Magnética , Ratones , Microscopía Fluorescente , Oligopéptidos/metabolismo
15.
Arthroscopy ; 25(2): 200-7, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19171281

RESUMEN

PURPOSE: The purposes of this study were to (1) perform a systematic review of randomized controlled trials evaluating graft tensioning in anterior cruciate ligament (ACL) reconstruction, and (2) determine the scientific quality of published randomized controlled trials evaluating graft tensioning in ACL reconstruction. METHODS: The search strategy included a computerized literature search, a citation search, and a manual search of key journals and conference proceedings. Eligible studies were randomized controlled trials evaluating the effect of graft tensioning on the outcomes of ACL reconstruction. Two reviewers independently performed the literature searches. The validity of the trials was scored using the Detsky quality scale. Consensus was achieved by a study committee of 3 investigators. RESULTS: Five randomized controlled trials met the inclusion criteria. The mean standardized Detsky score was 61.3 +/- 15.2%. Only 2 of the studies scored >or=75%. All trials consisted of autogenous graft sources, with 3 involving a bone-patellar tendon-bone graft, 1 involving a 5-strand semitendinosus-polyester (5STP) graft, and 1 involving a semitendinosus-gracilis-polyester (STGP) graft. CONCLUSIONS: Based on the evidence in this systematic review, there is a trend that suggests that 80 N of tension is the most effective amount of tension to apply during ACL reconstruction using hamstring-polyester graft sources. For ACL reconstruction using semitendinosus-gracilis or patellar tendon graft sources, there is no clear trend in terms of statistically significant or clinically relevant differences in terms of the amount of applied tension to apply to the graft during graft fixation. We are unable to provide recommendations as to the amount of tension to apply to 4-strand semitendinosus-gracilis autografts without polyester augmentation because there has been no randomized clinical trial conducted to determine the most effective amount of tension to apply when using this graft source.


Asunto(s)
Ligamento Cruzado Anterior/cirugía , Artroscopía/métodos , Procedimientos de Cirugía Plástica/métodos , Estrés Mecánico , Adulto , Lesiones del Ligamento Cruzado Anterior , Artroscopía/efectos adversos , Artroscopía/estadística & datos numéricos , Trasplante Óseo/métodos , Femenino , Humanos , Inestabilidad de la Articulación/prevención & control , Inestabilidad de la Articulación/cirugía , Masculino , Meniscos Tibiales/cirugía , Evaluación de Resultado en la Atención de Salud , Ligamento Rotuliano/trasplante , Poliésteres , Prótesis e Implantes , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Procedimientos de Cirugía Plástica/efectos adversos , Procedimientos de Cirugía Plástica/estadística & datos numéricos , Tendones/trasplante , Lesiones de Menisco Tibial , Trasplante Autólogo , Adulto Joven
16.
J Am Chem Soc ; 129(48): 14880-6, 2007 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-17994737

RESUMEN

In this work we present the preparation of highly luminescent anisotropic CdTe/CdSe colloidal heteronanocrystals. The reaction conditions used (low temperature, slow precursor addition, and surfactant composition) resulted in a tunable shape from prolate to branched CdTe/CdSe nanocrystals. Upon CdSe shell growth the heteronanocrystals show a gradual evolution from type-I to type-II optical behavior. These heteronanocrystals show a remarkably high photoluminescence quantum yield (up to 82%) and negligible thermally induced quenching up to temperatures as high as 373 K.

17.
J Shoulder Elbow Surg ; 16(6): 697-700, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17950628

RESUMEN

This study reanalyzes a group of patients who had anterior acromioplasty between 1975 and 1979, whose results were reported in 1990 at a mean 8-year follow-up, to identify any continuing problems or new complications, to assess the frequency of further surgery, and to define long-term outcome. Thirty-two patients were included. The mean follow-up was 25 years (range, 21 to 27 years). All had the impingement syndrome. At surgery, there was tendon and bursal inflammation with fibrosis in 28 shoulders and a small rotator cuff tear in 4. Five shoulders have required additional surgery: distal clavicle excision in one, revision anterior acromioplasty in one, and repair of a new rotator cuff tear in three. Of the shoulders, 23 (72%) were reported as having no or slight pain. Positive patient satisfaction was expressed in 28 (88%). Comparisons were made to the opposite shoulder in this older patient group. The mean within-patient difference between the operative shoulder and the opposite shoulder on the Simple Shoulder Test was 0.4, with scores of 8.9 for the operative side and 9.3 for the opposite side (P = .47). The mean difference in the American Shoulder and Elbow Surgeon's score was 8.6 points, with scores of 75 for the operative side and 83 for the opposite side (P = .02). The results of open acromioplasty for the impingement syndrome are usually maintained over time. Acromioplasty does not always prevent the need for subsequent rotator cuff surgery, but the rate of reoperation has remained relatively low in the long follow-up period.


Asunto(s)
Acromion/cirugía , Procedimientos Ortopédicos/métodos , Síndrome de Abducción Dolorosa del Hombro/cirugía , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
18.
IEEE Trans Neural Syst Rehabil Eng ; 25(10): 1864-1873, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28410110

RESUMEN

Rehabilitation robots have become increasingly popular for stroke rehabilitation. However, the high cost of robots hampers their implementation on a large scale. This paper implements the concept of a modular and reconfigurable robot, reducing its cost and size by adopting different therapeutic end effectors for different training movements using a single robot. The challenge is to increase the robot's portability and identify appropriate kinds of modular tools and configurations. Because literature on the effectiveness of this kind of rehabilitation robot is still scarce, this paper presents the design of a portable and reconfigurable rehabilitation robot and describes its use with a group of post-stroke patients for wrist and forearm training. Seven stroke subjects received training using a reconfigurable robot for 30 sessions, lasting 30 min per session. Post-training, statistical analysis showed significant improvement of 3.29 points (16.20%, p = 0.027) on the Fugl-Meyer assessment scale for forearm and wrist components. Significant improvement of active range of motion was detected in both pronation-supination (75.59%, p = 0.018) and wrist flexion-extension (56.12%, p = 0.018) after the training. These preliminary results demonstrate that the developed reconfigurable robot could improve subjects' wrist and forearm movement.


Asunto(s)
Mano/fisiopatología , Robótica , Rehabilitación de Accidente Cerebrovascular/instrumentación , Rehabilitación de Accidente Cerebrovascular/métodos , Muñeca , Anciano , Anciano de 80 o más Años , Femenino , Antebrazo/fisiopatología , Juegos Experimentales , Humanos , Masculino , Persona de Mediana Edad , Fuerza Muscular , Seguridad del Paciente , Satisfacción del Paciente , Educación y Entrenamiento Físico , Rango del Movimiento Articular , Accidente Cerebrovascular/fisiopatología , Rehabilitación de Accidente Cerebrovascular/efectos adversos , Resultado del Tratamiento , Realidad Virtual
19.
Nanoscale ; 8(47): 19901-19909, 2016 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-27878182

RESUMEN

Luminescent Ag clusters are prepared with lipoic acid (LA) as the ligand. Using a combination of mass spectrometry, optical spectroscopy and analytical ultracentrifugation, the clusters are found to be highly monodisperse with mass 5.6 kDa. We assign the chemical composition [Ag29(LA)12]3- to the clusters, where LA likely binds in a bidentate fashion. The Ag29 clusters show slow degradation, retaining their deep red emission for at least 18 months if stored in the dark. Purification or exposure to light results in faster degradation. No other cluster species are observed during the degradation process. Once degraded, the clusters could easily be regenerated using NaBH4, which is not usually observed for thiolate-capped Ag clusters.

20.
Am J Nucl Med Mol Imaging ; 2(2): 151-62, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23133810

RESUMEN

Optical guidance provided by luminescent marker seeds may be suitable for intraoperative determination of appropriate resection margins. In phantom studies we compared the tissue penetration of several organic dyes and inorganic particles (quantum dots; QDs) after incorporation in experimental marker seeds. The tissue penetration of (near infra-) red organic dyes was much better than the penetration of dyes and QDs with an emission in the visible range. By combining 3 dyes in a single marker seed we were able to distinguish four depth ranges. The difference in tissue penetration between the dyes and QDS enabled depth estimation via a 'traffic light' approach.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA