Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Eur Radiol ; 27(12): 5316-5324, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28656461

RESUMEN

OBJECTIVES: Objectives of this study were to compare radial time-resolved phase contrast magnetic resonance imaging (4D Flow-MRI) with perivascular ultrasound (pvUS) and to explore a porcine model of acute pre-hepatic portal hypertension (PHTN). METHODS: Abdominal 4D Flow-MRI and pvUS in portal and splenic vein, hepatic and both renal arteries were performed in 13 pigs of approximately 60 kg. In six pigs, measurements were repeated after partial portal vein (PV) ligature. Inter- and intra-reader comparisons and statistical analysis including Bland-Altman (BA) comparison, paired Student's t tests and linear regression were performed. RESULTS: PvUS and 4D Flow-MRI measurements agreed well; flow before partial PV ligature was 322 ± 30 ml/min in pvUS and 297 ± 27 ml/min in MRI (p = 0.294), and average BA difference was 25 ml/min [-322; 372]. Inter- and intra-reader results differed very little, revealed excellent correlation (R 2 = 0.98 and 0.99, respectively) and resulted in BA differences of -5 ml/min [-161; 150] and -2 ml/min [-28; 25], respectively. After PV ligature, PV flow decreased from 356 ± 50 to 298 ± 61 ml/min (p = 0.02), and hepatic arterial flow increased from 277 ± 36 to 331 ± 65 ml/min (p = n.s.). CONCLUSION: The successful in vivo comparison of radial 4D Flow-MRI to perivascular ultrasound revealed good agreement of abdominal blood flow although with considerable spread of results. A model of pre-hepatic PHTN was successfully introduced and acute responses monitored. KEY POINTS: • Radial 4D Flow-MRI in the abdomen was successfully compared to perivascular ultrasound. • Inter- and intra-reader testing demonstrated excellent reproducibility of upper abdominal 4D Flow-MRI. • A porcine model of acute pre-hepatic portal hypertension was successfully introduced. • 4D Flow-MRI successfully monitored acute changes in a model of portal hypertension.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Hipertensión Portal/diagnóstico , Circulación Hepática/fisiología , Angiografía por Resonancia Magnética/métodos , Vena Porta/diagnóstico por imagen , Ultrasonografía/métodos , Animales , Modelos Animales de Enfermedad , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/fisiopatología , Hipertensión Portal/fisiopatología , Masculino , Vena Porta/fisiopatología , Reproducibilidad de los Resultados , Porcinos
2.
J Biomech Eng ; 137(4): 044501, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25587800

RESUMEN

Pulmonary arteries (PAs) distend to accommodate increases in cardiac output. PA distensibility protects the right ventricle (RV) from excessive increases in pressure. Loss of PA distensibility plays a critical role in the fatal progression of pulmonary arterial hypertension (PAH) toward RV failure. However, it is unclear how PA distensibility is distributed across the generations of PA branches, mainly because of the lack of appropriate in vivo methods to measure distensibility of vessels other than the large, conduit PAs. In this study, we propose a novel approach to assess the distensibility of individual PA branches. The metric of PA distensibility we used is the slope of the stretch ratio-pressure relationship. To measure distensibility, we combined invasive measurements of mean PA pressure with angiographic imaging of the PA network of six healthy female dogs. Stacks of 2D images of the PAs, obtained from either contrast enhanced magnetic resonance angiography (CE-MRA) or computed tomography digital subtraction angiography (CT-DSA), were used to reconstruct 3D surface models of the PA network, from the first bifurcation down to the sixth generation of branches. For each branch of the PA, we calculated radial and longitudinal stretch between baseline and a pressurized state obtained via acute embolization of the pulmonary vasculature. Our results indicated that large and intermediate PA branches have a radial distensibility consistently close to 2%/mmHg. Our axial distensibility data, albeit affected by larger variability, suggested that the PAs distal to the first generation may not significantly elongate in vivo, presumably due to spatial constraints. Results from both angiographic techniques were comparable to data from established phase-contrast (PC) magnetic resonance imaging (MRI) and ex vivo mechanical tests, which can only be used in the first branch generation. Our novel method can be used to characterize PA distensibility in PAH patients undergoing clinical right heart catheterization (RHC) in combination with MRI.


Asunto(s)
Ensayo de Materiales , Fenómenos Mecánicos , Arteria Pulmonar , Animales , Fenómenos Biomecánicos , Presión Sanguínea , Perros , Femenino , Imagen por Resonancia Magnética , Arteria Pulmonar/fisiología , Estrés Mecánico
3.
AJNR Am J Neuroradiol ; 28(3): 531-2, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17353330

RESUMEN

BACKGROUND AND PURPOSE: The canine vein pouch aneurysm model is widely used for testing and development of devices directed at the endovascular treatment of aneurysms. Our purpose was to determine the incidence of spontaneous thrombosis and rupture of these aneurysms. MATERIALS AND METHODS: A retrospective review of laboratory records of canine vein pouch aneurysms made during a 6-year period was performed. The aneurysm and parent artery dimensions as well as incidences of spontaneous thrombosis and rupture were noted. RESULTS: During the interval studied, 326 vein patch aneurysms were made in 310 canines. Of these, 102 were sidewall (lateral) and 224 were bifurcation aneurysms. Spontaneous occlusion occurred in 9 of the sidewall aneurysms and in only 1 of the bifurcation aneurysms. None of the aneurysms ruptured. CONCLUSION: Spontaneous occlusion of the sidewall canine vein patch aneurysm occurred less than 10% of the time; in the bifurcation aneurysms, it almost never occurred. These characteristics enhance the value of this model for use in testing of devices intended for the endovascular treatment of aneurysms.


Asunto(s)
Aneurisma/epidemiología , Aneurisma/terapia , Modelos Animales de Enfermedad , Perros , Embolización Terapéutica , Aneurisma/diagnóstico por imagen , Aneurisma Roto/epidemiología , Angiografía de Substracción Digital , Animales , Incidencia , Trombosis/epidemiología , Venas
4.
AJNR Am J Neuroradiol ; 28(1): 111-5, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17213435

RESUMEN

BACKGROUND AND PURPOSE: Noninvasive assessment of the hemodynamic significance of carotid stenosis is often performed with MR angiography and supplemented with carotid Doppler sonography. Phase contrast with vastly undersampled isotropic projection reconstruction (PC-VIPR), a novel MR imaging technique, accelerates phase-contrast MR flow imaging and provides both images of the vessels and measurements of blood-flow velocities. For this study, we determined the accuracy of PC-VIPR blood-flow velocity measurements to determine pressure gradients across an experimental carotid stenosis. MATERIALS AND METHODS: A focal stenosis was surgically created in each common carotid artery of 6 canines. Digital subtraction angiography (DSA) was performed, and the degree of stenosis was determined using the North American Symptomatic Carotid Endarterectomy Trial methodology. A microcatheter was positioned in the carotid artery proximal and distal to the stenosis, and pressures were measured in the vessel through the catheter. PC-VIPR was then performed on a 1.5T MR imaging scanner with parameters producing 0.8-mm isotropic voxel resolution. From the velocity measurements, pressure gradients were calculated from the Navier-Stokes relationship to compare with the pressures measured by a catheter. RESULTS: Carotid stenoses in the 50%-85% range were produced in the 12 arteries. Pressure gradients across the stenoses ranged from 6 to 26 mm Hg. The pressure gradient calculated from the PC-VIPR data correlated (r = 0.91, P < .0001) with the actual pressure measurements. CONCLUSION: With PC-VIPR, a novel MR imaging technique, the hemodynamic effect of a stenosis on flow and pressure can be evaluated.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Estenosis Carotídea/fisiopatología , Modelos Animales de Enfermedad , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Animales , Presión Sanguínea/fisiología , Arteria Carótida Común/patología , Arteria Carótida Común/fisiopatología , Estenosis Carotídea/patología , Diástole/fisiología , Perros , Femenino , Sístole/fisiología
5.
AJNR Am J Neuroradiol ; 28(9): 1710-4, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17885239

RESUMEN

BACKGROUND AND PURPOSE: Currently, more reliable parameters to predict the risk of aneurysmal rupture are needed. Intra-aneurysmal pressure gradients and flow maps could provide additional information regarding the risk of rupture. Our hypothesis was that phase contrast with vastly undersampled isotropic projection reconstruction (PC-VIPR), a novel 3D MR imaging sequence, could accurately assess intra-aneurysmal pressure gradients in a canine aneurysmal model when compared with invasive measurements. MATERIALS AND METHODS: A total of 13 surgically created aneurysms in 8 canines were included in this study. Pressure measurements were performed in the parent vessel, aneurysm neck, and 5 regions within the aneurysmal sac with a microcatheter. PC-VIPR sequence was used to obtain cardiac-gated velocity measurements in a region covering the entire aneurysm. The velocity and pressure gradient maps derived from the PC-VIPR data were then coregistered with the anatomic DSA images and compared with catheter measurements. RESULTS: In 7 of the bifurcation aneurysms, the velocity flow maps demonstrated a recirculation flow pattern with a small neck-to-dome pressure gradient (mean, +0.5 mm Hg). In 1 bifurcation aneurysm, a flow jet extending from the neck to the dome with significantly greater pressure gradient (+50.2 mm Hg) was observed. All sidewall aneurysms had low flow in the sac with intermediate pressure gradients (mean, +8.3 mm Hg). High statistical correlation existed between PC-VIPR aneurysmal pressures and microcatheter pressure measurements (R = 0.82, P < .01). CONCLUSION: PC-VIPR can provide anatomic as well as noninvasive quantitative and qualitative hemodynamic information in the canine aneurysm model. The PC-VIPR intra-aneurysmal pressure measurements correlated well with catheter measurements.


Asunto(s)
Algoritmos , Velocidad del Flujo Sanguíneo , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Aneurisma Intracraneal/diagnóstico , Aneurisma Intracraneal/fisiopatología , Presión Intracraneal , Imagen por Resonancia Magnética/métodos , Animales , Anisotropía , Perros , Femenino , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
AJNR Am J Neuroradiol ; 27(2): 354-5, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16484409

RESUMEN

In dogs, a wire with a pressure-sensitive transducer was inserted percutaneously into the subarachnoid space and manipulated under fluoroscopic monitoring in the posterior fossa or upper cervical spinal canal. Pressure recordings from the wire showed fluctuations in pressure corresponding to the cardiac cycle. When a balloon was distended in the foramen magnum, maximum and minimum pressures increased. Continuous monitoring of CSF pressure remote from the site of cannulation was feasible with a wire-based pressure transducer.


Asunto(s)
Malformación de Arnold-Chiari/fisiopatología , Presión del Líquido Cefalorraquídeo/fisiología , Modelos Animales de Enfermedad , Contracción Miocárdica/fisiología , Transductores de Presión , Animales , Malformación de Arnold-Chiari/diagnóstico , Perros , Electrocardiografía , Diseño de Equipo , Fluoroscopía , Foramen Magno , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Canal Medular , Espacio Subaracnoideo , Ventriculostomía/instrumentación
7.
AJNR Am J Neuroradiol ; 34(11): 2131-8, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23703149

RESUMEN

BACKGROUND AND PURPOSE: Assessment of perfusion parameters is important in the selection of patients who are most likely to benefit from revascularization after an acute ischemic stroke. The aim of this study was to evaluate the feasibility of measuring cerebral perfusion parameters with the use of a novel high-speed C-arm CT acquisition in conjunction with a single intravenous injection of contrast. MATERIALS AND METHODS: Seven canines had experimentally induced focal ischemic regions confirmed by CT perfusion imaging. Four hours after ischemic injury creation, each subject underwent cerebral perfusion measurements with the use of standard perfusion CT, immediately followed by the use of C-arm CT. Cerebral blood flow and cerebral blood volume maps measured by C-arm CT were quantitatively and qualitatively compared with those measured by perfusion CT for 6 of the 7 canine subjects. RESULTS: Results from independent observer evaluations of perfusion CT and C-arm perfusion maps show strong agreement between observers for identification of ischemic lesion location. Significant percentage agreement between observers for lesion detection and identification of perfusion mismatch between CBV and CBF maps indicate that the maps for both perfusion CT and C-arm are easy to interpret. Quantitative region of interest-based evaluation showed a strong correlation between the perfusion CT and C-arm CBV and CBF maps (R(2) = 0.68 and 0.85). C-arm measurements for both CBV and CBF were consistently overestimated when compared with perfusion CT. CONCLUSIONS: Qualitative and quantitative measurements of CBF and CBV with the use of a C-arm CT acquisition and a single intravenous injection of contrast agent are feasible. Future improvements in flat detector technology and software algorithms probably will enable more accurate quantitative perfusion measurements with the use of C-arm CT.


Asunto(s)
Algoritmos , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/fisiopatología , Angiografía Cerebral/métodos , Circulación Cerebrovascular , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Velocidad del Flujo Sanguíneo , Volumen Sanguíneo , Determinación del Volumen Sanguíneo/métodos , Medios de Contraste/administración & dosificación , Perros , Inyecciones Intravenosas , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
AJNR Am J Neuroradiol ; 33(9): 1696-701, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22627802

RESUMEN

BACKGROUND AND PURPOSE: Measurement of perfusion parameters is typically done using an intravenous injection of contrast medium. This purpose of this study was to evaluate the feasibility of measuring regional and global CBV using C-arm CT with IA injections of contrast medium. MATERIALS AND METHODS: Twelve canines were studied. CBV measurement was performed using standard PCT, and then using C-arm CT with IV and IA contrast. Values obtained using C-arm CT were compared with those using PCT. RESULTS: C-arm CT CBV maps using IA injections required less contrast than ones with IV injections. PCT and C-arm CT using IV and AA injections provided comparable maps. In controls, C-arm CT with a CCA or VA injection provided comparable maps to PCT. In animals with a stroke, a CCA or VA injection did not provide maps comparable to ones made with PCT. IV and AA C-arm CT showed excellent quantitative agreement with PCT, while CCA and VA C-arm CT studies did not. CONCLUSIONS: Measurement of global CBV using C-arm CT in conjunction with either an IV or an AA injection was feasible in controls and dogs with a stroke. Measurement of regional CBV with C-arm CT using either CCA or VA injection, in normal canines, provided CBV maps qualitatively comparable with those obtained with PCT; the absolute CBV values from these maps were in poor agreement with PCT measurements. Valid measurement of CBV using C-arm CT requires all tissue in a target region to be fully and equally opacified during any acquisition. Using CCA or VA injections, it was impossible to document if and when this had been achieved. CBV measurements using these routes of injection were therefore not reliable.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Volumen Sanguíneo/fisiología , Isquemia Encefálica/fisiopatología , Arterias Cerebrales/fisiología , Circulación Cerebrovascular/fisiología , Imagen de Perfusión/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Animales , Isquemia Encefálica/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Perros , Inyecciones Intraarteriales , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
AJNR Am J Neuroradiol ; 33(3): 507-12, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22194362

RESUMEN

BACKGROUND AND PURPOSE: To our knowledge, no reproducible animal model of a giant bifurcation type aneurysm has been described. It was our aim to develop a 1-stage and reproducible model of a venous pouch giant aneurysm in canines. MATERIALS AND METHODS: Nine canines were involved. Bilateral CCAs were exposed. The left CCA was divided and its distal segment was swung to the right side. Using the right CCA and the distal segment of the left CCA, either a bifurcation or a terminal arterial structure was constructed. Bilateral external jugular veins were also exposed. A 30-mm vein segment was harvested from each side. Each vein graft was split and unfolded to make 2 venous sheets. These sheets were then joined top-to-bottom so as to form a single cylinder in such a way that original adventitial side of the venous sheets was on the exterior surface. In 2 instances, pieces of polytetrafluoroethylene were employed along with the venous sheets. The combined vein graft was then incorporated into the arterial anastomosis. Lastly, the top of the venous pouch was closed. No medications for anticoagulant or antiplatelet were used throughout the study period. Follow-up imaging studies were performed. RESULTS: It took 2.5 hours on average for 2 operators to create an aneurysm. Eight of the 9 aneurysms were patent at follow-up. The cause of the spontaneous thrombosis was unclear despite autopsy. All the aneurysms had a maximum diameter >20 mm. CONCLUSIONS: We demonstrated and illustrated a 1-stage and reproducible procedure to create a model of a venous pouch bifurcation giant aneurysm in canines.


Asunto(s)
Modelos Animales de Enfermedad , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/fisiopatología , Animales , Circulación Cerebrovascular , Perros , Estudios de Factibilidad , Humanos , Radiografía
10.
AJNR Am J Neuroradiol ; 31(8): 1508-11, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20488903

RESUMEN

BACKGROUND AND PURPOSE: Imaging is a key element in the study of many rodent models of human diseases. The application of DSA has been limited in these studies in part because of a lack of a method that allows serial intra-arterial examinations to be performed during an extended period of time. It was our intent to develop and test a method for performing sequential arterial catheterizations and DSA in rats. MATERIALS AND METHODS: Using a transfemoral approach, we subjected 12 adult male Harvey rats to 3 sequential DSA examinations during a 6- to 8-week period. At each examination, 2 selective arterial catheterizations and a DSA were performed. Animals were monitored for ill effects, and images from the 3 examinations were compared for quality and the presence of any arterial injury. RESULTS: Ten of the 12 rats survived all 3 examinations. There were no adverse effects noted and no evidence of arterial injury from the examinations. CONCLUSIONS: With the technique described, it is possible to perform serial arterial catheterizations and DSA in rats. This technique will be useful as an adjunct in the use of rodents for the study of human diseases.


Asunto(s)
Angiografía de Substracción Digital/métodos , Cateterismo/métodos , Angiografía Cerebral/métodos , Angiografía de Substracción Digital/mortalidad , Animales , Cateterismo/mortalidad , Angiografía Cerebral/mortalidad , Circulación Cerebrovascular , Modelos Animales de Enfermedad , Arteria Femoral , Masculino , Morbilidad , Ratas , Ratas Endogámicas , Roedores
11.
AJNR Am J Neuroradiol ; 31(3): 536-40, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20053809

RESUMEN

BACKGROUND AND PURPOSE: CBV is a key parameter in distinguishing penumbra from ischemic core. The purpose of this study was to compare CBV measurements acquired with standard PCT with ones obtained with C-arm CT in a canine stroke model. MATERIALS AND METHODS: Under an institutionally approved protocol, unilateral MCA strokes were created in 10 canines. Four hours later, DWI was used to confirm the presence of an infarct. CBV maps acquired with PCT were compared with ones acquired by using C-arm CT. Three experienced observers, blinded to the technique used for acquisition, evaluated the CBV maps. RESULTS: An ischemic stroke was achieved in 9 of the 10 animals. Areas of reduced CBV were detected in 70%-75% of the PCT studies and in 83%-87% of the C-arm CT examinations, with false-positives in 1.7% and 3.3%, respectively. False-negatives were found in 25% of the PCT and 12.2% of the C-arm CT studies. In all studies, there was a significant difference between the absolute CBV values in normal and abnormal tissue (P < .005) and no significant difference between PCT and C-arm CT CBV values in either the normal or the abnormal parenchyma (P > .05). CONCLUSIONS: CBV measurements made with C-arm CT compare well with ones made with PCT. While further work is required both to fully validate the technique and to define its ultimate clinical value, it appears that it offers a feasible method for assessing CBV in the angiography suite.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Isquemia Encefálica/diagnóstico por imagen , Circulación Cerebrovascular , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Enfermedad Aguda , Animales , Angiografía Cerebral/métodos , Angiografía Cerebral/normas , Modelos Animales de Enfermedad , Perros , Reacciones Falso Negativas , Reacciones Falso Positivas , Tomografía Computarizada por Rayos X/normas
12.
AJNR Am J Neuroradiol ; 30(5): 917-22, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19299488

RESUMEN

BACKGROUND AND PURPOSE: Cerebral blood volume (CBV) is an important parameter in estimating the viability of brain tissue following an ischemic event. We tested the hypothesis that C-arm CT measurements of CBV would correlate well with those made with perfusion CT (PCT). MATERIALS AND METHODS: CBV was measured in 12 canines by using PCT and C-arm CT. Two measurements with each technique were made on each animal; a different injection protocol was used for each of these techniques. PCT was performed by using a 64-section V-scanner. C-arm CT was performed by using a biplane Artis dBA system. PCT images were transferred to a commercially available workstation for postprocessing and analysis; C-arm CT images were transferred to a commercially available workstation for postprocessing and analysis by using prototype software. From each animal, 2 sections from each technique were selected for analysis. RESULTS: There was good agreement of both the color maps and absolute numbers between the 2 techniques. The maximum and mean deviations of values between the 2 techniques for the first 5 animals were 30.20% and 7.82%; for the second 7 animals, these values were 26.79% and 7.40%. The maximum and mean deviations between the 2 C-arm CT studies performed on the first 5 animals were 33.15% and 12.24%; for the second 7 animals, these values were 41.15% and 10.89%. CONCLUSIONS: In these healthy animals, measurement of CBV with C-arm CT compared well with measurements made with PCT.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Encéfalo/irrigación sanguínea , Encéfalo/fisiología , Angiografía Cerebral/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Perros
13.
AJNR Am J Neuroradiol ; 30(7): 1337-41, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19461063

RESUMEN

BACKGROUND AND PURPOSE: Recent advances in flat panel detector angiographic equipment have provided the opportunity to obtain physiologic and anatomic information from angiographic examinations. To exploit this possibility, one must understand the factors that affect the bolus geometry of an intra-arterial injection of contrast medium. It was our purpose to examine these factors in a canine model. MATERIALS AND METHODS: Under an institutionally approved protocol conforming to Guide for the Care and Use of Laboratory Animals of the National Institutes of Health, 7 canines were placed under general anesthesia with isoflurane and propofol. Through a 5F catheter placed into the right common carotid artery, a series of biplane angiographic acquisitions was obtained to examine the effects caused by variation in the volume of injection, the rate of injection, the duration of injection, the concentration of contrast medium, and the catheter position on arterial, capillary, and venous opacification. The results of each injection protocol were determined from analysis of a time-contrast concentration curve derived from locations over an artery, in brain parenchyma, and over a vein. The curve was generated from 2D digital subtraction angiography acquisitions by using prototype software. The area under the curve, the amplitude of the curve, and the time to peak (TTP) were analyzed separately for each injection parameter. RESULTS: Changes in the injection protocols resulted in predictable changes in the time-concentration curves. The injection parameter that contributed most to maximum opacification was the volume of contrast medium injected. When the injection rate was fixed and the volume was varied, there was an increase in opacification (maximal) proportional to the injected volume. The injected volume also had an indirect (secondary) impact on the temporal characteristics of the opacification. The time-concentration curve became wider, and the peak was shifted to the right as the injection duration increased. The impact of injected volume on maximal opacification was significant (P < .0001), regardless of the site of measurement (artery, tissue, and vein); however, the impact on the temporal characteristics of the time-concentration curve reached statistical significance only in measurements made in the artery and the vein (P < .05), but not in the tissue (P > .1). The impact of injected volume on maximal opacification became nonproportional in the tissue and vein when the volume was very large (>12 mL). Increasing the concentration of contrast medium resulted in a nonproportional increase in the height of the time-concentration curves (P < .05). Injection rate had an impact on both maximal opacification and TTP. The impact on TTP occurred only when the injection rate was very slow (1 mL/s). Changes of concentration had a similar impact on the time-concentration curve. Catheter position did not cause significant alterations in the shape of the curves. CONCLUSIONS: There were predictable effects from modification of injection parameters on the contrast bolus geometry and on time-concentration curves as measured in an artery, brain parenchyma, or a vein. The amplitude, TTP, and area under the time-concentration curve depend mainly and proportionally on the amount of iodine traversing the vasculature per second. Other injection parameters were of less importance in defining bolus geometry. These findings mimic those observed in studies of parameters affecting bolus geometry following an intravenous injection.


Asunto(s)
Angiografía de Substracción Digital/métodos , Arterias/metabolismo , Capilares/metabolismo , Angiografía Cerebral/métodos , Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Venas/metabolismo , Animales , Capilares/diagnóstico por imagen , Perros , Inyecciones Intraarteriales , Tasa de Depuración Metabólica , Organización y Administración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA