Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Analyst ; 147(23): 5477-5485, 2022 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-36321954

RESUMEN

Lossy mode resonance (LMR)-based optical sensors change their wavelength upon contact with substances or gases. This allows developing applications to detect the refractive index of the surrounding medium and even the thickness of the biolayers deposited on the waveguide. In the same way, when acoustic sensors are in contact with a liquid, it is possible to determine parameters, especially mechanical ones such as shape of the particle or molecule, mass load, elastic constants and viscosity of the liquid. This work reports the development of a system that combines LMR with surface acoustic wave (SAW) technologies to characterize a liquid in terms of its refractive index and viscosity simultaneously. Conveniently prepared glucose solutions are used for sensor calibration. The refractive index of the solutions ranges from 1.33 to 1.41 and its viscosity ranges from 1.005 mPa·s to 9 mPa·s, respectively. A sensitivity of 332 nm per RIU has been achieved with the optical sensor while the acoustic sensor has shown a sensitivity of -1.5 dB/(mPa·s). This new combinational concept could be expanded to the development of more demanding applications such as chemical sensors or biosensors.

2.
Opt Express ; 28(1): 288-301, 2020 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-32118958

RESUMEN

The generation of lossy mode resonances (LMRs) with a setup based on lateral incidence of light in coverslips is a simple platform that can be used for sensing. Here the versatility of this platform is proved by studying the deposition of different coating materials. The devices were characterized with both SEM and AFM microscopy, as well as ellipsometry, which allowed obtaining the main parameters of the coatings (thickness, refractive index and extinction coefficient) and relating them with the different sensitivities to refractive index attained with each material. In this way it was possible to confirm and complete the basic rules observed with lossy mode resonance based optical fiber sensors towards the design of simpler and more compact applications in domains such as chemical sensors or biosensors.

3.
Opt Lett ; 45(17): 4738-4741, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32870845

RESUMEN

The full width at half maximum (FWHM) of lossy mode resonances (LMRs) in the optical spectrum depends on the homogeneity of the thin film deposited. In this Letter, a method for improving the FWHM is applied for an LMR generated by a D-shaped optical fiber in reflection configuration. For this purpose, three samples with different attenuation were deposited with DC sputtering thin films of SnO2-x, and a further controlled immersion of the samples in water was performed. A laser-cleaner method was used to improve the FWHM characteristics of one of the samples from 106 to 53 nm. This improvement can be applied to thin-film-based sensors where there is a problem with the inhomogeneity of the coating thickness. Moreover, with this technique, it was proved that a coated length of just 3-4 mm permits the generation of an LMR, with implications for the miniaturization of the final device.

4.
J Emerg Med ; 57(6): 780-790, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31591077

RESUMEN

BACKGROUND: Nontraumatic headache is a frequent complaint in the emergency department (ED). Cranial computed tomography (CT) is a widely available test for the diagnostic work-up, despite the risk of exposure to ionizing radiation. OBJECTIVES: We sought to develop and evaluate a cranial CT request computerized decision support system (CDSS) for adults with their first presentation of unusual severe nontraumatic headache in the ED. METHODS: Electronic database searches identified clinical decision and prediction rules and studies delineating risk factors in nontraumatic headache. A long list of risk factors extracted from these articles was reduced by a 30-member multidisciplinary expert panel (radiologists, emergency physicians, methodologists), using a 90% agreement threshold. This shortlist was used to develop the algorithm for the cranial CT request CDSS, which was implemented in March 2016. Impact evaluation compared CT scan frequency and diagnostic yield of pathologic findings before (March-August 2015) and after (March-August 2016) implementation. RESULTS: From the 10 selected studies, 10 risk factors were shortlisted to activate a request for cranial CT. Before implementation, 377 cranial CTs were ordered (15.3% of 2469 CT scans) compared with 244 after (9.5% of 2561 CT scans; pre-post difference 5.74%; 95% confidence interval [CI] 3.92-7.56%; p < 0.001), corresponding to a 37.6% relative reduction in the test ordering rate (95% CI 25.7-49.5%; p < 0.001). Despite the reduction in cranial CT scans, we did not observe an increase in pathological findings after introducing the decision support system (70 cases before [18.5%] vs. 35 cases after [14.3%]; pre-post difference -4.0% [95% CI -10.0 to 1.6%]; p = 0.170). CONCLUSION: In nontraumatic headache among adults seen in the ED, CDSS decreased the cranial CT request rate but the diagnostic yield did not improve.


Asunto(s)
Técnicas de Apoyo para la Decisión , Cefalea/diagnóstico por imagen , Tomografía Computarizada por Rayos X/clasificación , Distribución de Chi-Cuadrado , Servicio de Urgencia en Hospital/organización & administración , Servicio de Urgencia en Hospital/normas , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Cefalea/clasificación , Cefalea/etiología , Humanos , Masculino , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos
5.
Sensors (Basel) ; 19(3)2019 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-30708989

RESUMEN

Due to the risks that water contamination implies for human health and environmental protection, monitoring the quality of water is a major concern of the present era. Therefore, in recent years several efforts have been dedicated to the development of fast, sensitive, and selective sensors for the detection of heavy metal ions. In particular, fluorescent sensors have gained in popularity due to their interesting features, such as high specificity, sensitivity, and reversibility. Thus, this review is devoted to the recent advances in fluorescent sensors for the monitoring of these contaminants, and special focus is placed on those devices based on fluorescent aptasensors, quantum dots, and organic dyes.

6.
Sensors (Basel) ; 18(6)2018 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-29880731

RESUMEN

Here, we present a novel method to fabricate long period gratings using standard single mode optical fibers (SMF). These optical devices were fabricated in a three-step process, which consisted of etching the SMF, then coating it with a thin-film and, the final step, which involved removing sections of the coating periodically by laser ablation. Tin dioxide was chosen as the material for this study and it was sputtered using a pulsed DC sputtering system. Theoretical simulations were performed in order to select the appropriate parameters for the experiments. The responses of two different devices to different external refractive indices was studied, and the maximum sensitivity obtained was 6430 nm/RIU for external refractive indices ranging from 1.37 to 1.39.

7.
Sensors (Basel) ; 17(5)2017 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-28468267

RESUMEN

The refractive index of sputtered indium oxide nanocoatings has been altered just by changing the sputtering parameters, such as pressure. These induced changes have been exploited for the generation of a grating on the end facet of an optical fiber towards the development of wavelength-modulated optical fiber humidity sensors. A theoretical analysis has also been performed in order to study the different parameters involved in the fabrication of this optical structure and how they would affect the sensitivity of these devices. Experimental and theoretical results are in good agreement. A sensitivity of 150 pm/%RH was obtained for relative humidity changes from 20% to 60%. This kind of humidity sensors shows a maximum hysteresis of 1.3% relative humidity.

8.
Sensors (Basel) ; 17(4)2017 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-28422074

RESUMEN

A wide range of applications such as health, human comfort, agriculture, food processing and storage, and electronic manufacturing, among others, require fast and accurate measurement of humidity. Sensors based on optical fibers present several advantages over electronic sensors and great research efforts have been made in recent years in this field. The present paper reports the current trends of optical fiber humidity sensors. The evolution of optical structures developed towards humidity sensing, as well as the novel materials used for this purpose, will be analyzed. Well-known optical structures, such as long-period fiber gratings or fiber Bragg gratings, are still being studied towards an enhancement of their sensitivity. Sensors based on lossy mode resonances constitute a platform that combines high sensitivity with low complexity, both in terms of their fabrication process and the equipment required. Novel structures, such as resonators, are being studied in order to improve the resolution of humidity sensors. Moreover, recent research on polymer optical fibers suggests that the sensitivity of this kind of sensor has not yet reached its limit. Therefore, there is still room for improvement in terms of sensitivity and resolution.

9.
Sensors (Basel) ; 17(9)2017 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-28902137

RESUMEN

The diameter of long-period fiber gratings (LPFGs) fabricated in optical fibers with a low cutoff wavelength was be reduced by hydrofluoric acid etching, enhancing the sensitivity to refractive index by more than a factor of 3, to 2611 nm/refractive index unit in the range from 1.333 to 1.4278. The grating period selected for the LPFGs allowed access to the dispersion turning point at wavelengths close to the visible range of the optical spectrum, where optical equipment is less expensive. As an example of an application, a pH sensor based on the deposition of a polymeric coating was analyzed in two situations: with an LPFG without diameter reduction and with an LPFG with diameter reduction. Again, a sensitivity increase of a factor of near 3 was obtained, demonstrating the ability of this method to enhance the sensitivity of thin-film-coated LPFG chemical sensors.

10.
Sensors (Basel) ; 17(10)2017 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-29019945

RESUMEN

The measurement of chemical and biomedical parameters can take advantage of the features exclusively offered by optical fibre: passive nature, electromagnetic immunity and chemical stability are some of the most relevant ones. The small dimensions of the fibre generally require that the sensing material be loaded into a supporting matrix whose morphology is adjusted at a nanometric scale. Thanks to the advances in nanotechnology new deposition methods have been developed: they allow reagents from different chemical nature to be embedded into films with a thickness always below a few microns that also show a relevant aspect ratio to ensure a high transduction interface. This review reveals some of the main techniques that are currently been employed to develop this kind of sensors, describing in detail both the resulting supporting matrices as well as the sensing materials used. The main objective is to offer a general view of the state of the art to expose the main challenges and chances that this technology is facing currently.

11.
Opt Express ; 24(16): 17680-5, 2016 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-27505736

RESUMEN

This work presents a refractive index sensor based on a long period fiber grating (LPFG) made in a reduced cladding fiber whose low order cladding modes have the turning point at large wavelengths. The combination of these parameters results in an improved sensitivity of 8734 nm/refractive index unit (RIU) for the LP0,3 mode in the 1400-1650 wavelength range. This value is similar to that obtained with thin-film coated LPFGs, which permits to avoid the coating deposition step. The numerical simulations are in agreement with the experimental results.

12.
Thorax ; 70(9): 909-11, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25666436

RESUMEN

This study aimed to determine the effect of an evidence-based clinical decision support (CDS) algorithm on the use and yield of CT pulmonary angiography (CTPA) and on outcomes of patients evaluated in the emergency department (ED) for suspected PE. The study included 1363 consecutive patients evaluated for suspected PE in an ED during 12 months before and 12 months after initiation of CDS use. Introduction of CDS was associated with decreased CTPA use (55% vs 49%; absolute difference (AD), 6.3%; 95% CI 1.0% to 11.6%; p=0.02). The use of CDS was associated with fewer symptomatic venous thromboembolic events during follow-up in patients with an initial negative diagnostic evaluation for PE (0.7% vs 3.2%; AD 2.5%; 95% CI 0.9% to 4.6%; p<0.01).


Asunto(s)
Angiografía/métodos , Sistemas de Apoyo a Decisiones Clínicas , Embolia Pulmonar/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Algoritmos , Servicio de Urgencia en Hospital , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad
13.
Opt Express ; 23(3): 1930-7, 2015 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-25836065

RESUMEN

Integrated optical devices comprised of multiple material systems are able to achieve unique performance characteristics, enabling applications in sensing and in telecommunications. Due to ease of fabrication, the majority of previous work has focused on polymer-dielectric or polymer-semiconductor systems. However, the environmental stability of polymers is limited. In the present work, a hybrid device comprised of an indium tin oxide (ITO) coating on a silicon dioxide toroidal resonant cavity is fabricated. Finite element method simulations of the optical field in the multi-material device are performed, and the optical mode profile is significantly altered by the high index film. The quality factor is also measured and is material loss limited. Additionally, its performance as a temperature sensor is characterized. Due to the high thermo-optic coefficient of ITO and the localization of the optical field in the ITO layer, the hybrid temperature sensor demonstrates a nearly 3-fold improvement in performance over the conventional silica device.


Asunto(s)
Dispositivos Ópticos , Temperatura , Análisis de Elementos Finitos , Modelos Teóricos , Dispositivos Ópticos/estadística & datos numéricos , Dióxido de Silicio , Termómetros/estadística & datos numéricos , Compuestos de Estaño
14.
Opt Lett ; 40(21): 4867-70, 2015 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-26512470

RESUMEN

In this work, the modal transition induced by lossy mode resonances has been analyzed as a function of wavelength for thin-film coated cladding removed fibers. The wavelength dependence of the modal structure allows us to explain the resonance phenomenon. The numerical data obtained were calculated with a method based on the exact calculation of core modes. Theoretical simulations have been compared with experimental results showing good agreement.

15.
Appl Opt ; 53(18): 3913-9, 2014 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-24979423

RESUMEN

Thin-film coated single-mode-multimode-single-mode (SMS) structures have been analyzed both theoretically and experimentally with the aim of detecting different refractive indices. By adequate selection of the thickness of the thin film and of the diameter of the multimode segment in the SMS structure, a seven-fold improvement can be obtained in the sensitivity of the device to the surrounding medium refractive index, achieving a maximum sensitivity of 1199.18 nm/refractive index unit for the range of refractive indices from 1.321 to 1.382. Using layer-by-layer self-assembly for deposition, both on the cladding and on the tip of the multimode segment, allows the reflected power to increase, which avoids the application of a mirror on the tip of the multimode segment.

16.
Opt Express ; 21(25): 31668-77, 2013 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-24514739

RESUMEN

In this work an optical fiber tunable filter based on lossy guided-mode resonances (LGMR) is proposed. It consists of a multilayer structure deposited onto the surface of a plastic cladding removed multimode fiber. The first layer is used to generate the LGMR and to work as the first electrode as well; the second one to tune the filter and the outer layer forms the other electrode. The fabricated filter has demonstrated a good sensitivity to the applied voltage showing a change of the LGMR wavelength of 0.4 nm/V. Among other applications, this filter is intended to be used as electro-optic wavelength filter or modulator.

17.
Opt Express ; 21(10): 12668-82, 2013 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-23736487

RESUMEN

By coating a single-mode-multimode-single-mode (SMS) structure with a high refractive index thin-film it is possible to obtain a transition of modes for specific combinations of thin-film thickness, thin-film refractive index and surrounding medium refractive index, which permits to develop devices with a high sensitivity to specific parameters. In order to gain a better knowledge of the phenomenon the experimental results are corroborated numerically with the Transfer-Matrix-Method. The influence of losses in the thin-film has also been studied. The results obtained prove that a thin-film coated SMS structure is a simple and cost-effective platform for development of sensors and optical filters.


Asunto(s)
Membranas Artificiales , Refractometría/instrumentación , Refractometría/métodos , Resonancia por Plasmón de Superficie/instrumentación , Resonancia por Plasmón de Superficie/métodos , Diseño de Equipo , Análisis de Falla de Equipo
18.
Eur J Emerg Med ; 30(1): 40-46, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36542336

RESUMEN

Acute nontraumatic chest pain is a frequent reaso n for consultation in emergency departments and represents a diagnostic challenge. The objective is to estimate the risk of significant coronary artery disease (CAD) in patients with cardiogenic acute chest pain for whom the diagnosis of infarction was ruled out in the emergency department with a nondiagnostic ECG and negative high-sensitivity troponins. We prospectively recruited 1625 patients from emergency departments of seven Spanish hospitals. The outcome was presence of significant CAD determined by presence of ischaemia in functional tests or more than 70% stenosis in imaging tests. In this study, we developed a predictive model and evaluated its performance and clinical utility. The prevalence of significant CAD was 14% [227/1625; 95% confidence interval (CI), 12-16]. MAPAC Cardio-PreTest model included seven predictors: age, sex, smoking, history of hypertension, family history of CAD, history of hyperuricaemia, and type of chest pain. The optimism-adjusted model discrimination was C-statistic 0.654 (95% CI, 0.618-0.693). Calibration plot showed good agreement between the predicted and observed risks, and calibration slope was 0.880 (95% CI, 0.731-1.108) and calibration-in-the-large -0.001 (95% CI, -0.141 to 0.132). The model increased net benefit and improved risk classification over the recommended approach by the European Society of Cardiology [Net Reclassification Index (NRI) of events = 5.3%, NRI of nonevents = 7.0%]. MAPAC Cardio-PreTest model is an online prediction tool to estimate the individualised probability of significant CAD in patients with acute chest pain without a diagnosis of infarction in emergency department. The model was more useful than the current alternatives in helping patients and clinicians make individually tailored choices about the intensity of monitoring or additional coronary tests.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/epidemiología , Medición de Riesgo/métodos , Valor Predictivo de las Pruebas , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/epidemiología , Dolor en el Pecho/etiología , Servicio de Urgencia en Hospital , Infarto , Factores de Riesgo
19.
Sci Rep ; 11(1): 13228, 2021 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-34168261

RESUMEN

Multi-parameter detection is key in the domain of sensors. Here it is demonstrated that an indium tin oxide (ITO) nanocoating can be used to generate multiple lossy mode resonances (LMRs) in the optical spectrum. To achieve this, a nanocoating with a gradient in thickness is generated on the surface of a planar waveguide, permitting broadening of the LMR because the position of an LMR in the optical spectrum is directly related to the nanocoating thickness. The nanocoating with a gradient in thickness contributes multiple LMRs, each one centred at a different wavelength. With a further etching or deposition using a mask, a pattern of deposited and non-deposited regions can be created, resulting in isolation of the LMRs by preventing LMR overlap. This enables tracking of each central wavelength separately, which can be tuned through control of the gradient or nanocoating pattern. The array of LMR-based sensors is a photonics analogue to the interdigital concept in electronics, enabling multiple resonances to be used for multiparameter sensing.

20.
Sci Rep ; 11(1): 3669, 2021 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-33574474

RESUMEN

The incidence of light on the edge of a glass coverslip for a microscope slide, deposited with a thin film on both faces, permits exciting two resonances in each polarisation state of the input light, TE and TM. This dually nanocoated waveguide can be used for detecting simultaneously two different parameters on the basis of a further deposition of suitable materials on each face. As an example, the possibility of detecting temperature and humidity by using polydimethylsiloxane and agarose coatings, respectively, was demonstrated, which opens the path for the development of other dual-parameter sensors, and for even more parameters in cases in which each face of the coverslip is patterned. Moreover, the device was optimised in order to position two resonances in the near infrared (NIR) and two resonances in the visible region, with sensitivities of 0.34 nm/°C and 0.23 nm/%RH in the visible region and 1.16 nm/°C and 0.34 nm/%RH in the NIR, respectively, demonstrating the possibility of using the device in both spectral ranges and opening the path for the development of sensors based on multiple resonances, each one related to a different parameter to be detected.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA