Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Cardiol Young ; 34(2): 262-267, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37317547

RESUMEN

BACKGROUND: Lifetime radiation exposure for paediatric orthotopic heart transplant (OHT) patients is significant with cardiac catheterisation as the dominant source. Interventional cardiac magnetic resonance is utilised to obtain simultaneous, radiation-free haemodynamics and flow/function measurements. We sought to compare invasive haemodynamic measurements and radiation exposure in traditional cardiac catheterisation, to comprehensive interventional cardiac magnetic resonance. METHODS: Twenty-eight OHT patients who underwent 67 interventional cardiac magnetic resonance procedures at Children's National Hospital were identified. Both invasive oximetry with peripheral oxygen saturation (Fick) and cardiac magnetic resonance phase contrast measurements of pulmonary and systemic blood flow were performed. Systemic and pulmonary blood flow from the two modalities was compared using Bland-Altman, concordance analysis, and inter-reader correlation. A mixed model was implemented to account for confounding variables and repeat encounters. Radiation dosage data were collected for a contemporaneous cohort of orthotopic heart transplant patients undergoing standard, X-ray-guided catheterisation. RESULTS: Simultaneous cardiac magnetic resonance and Fick have poor agreement in our study based on Lin's correlation coefficient of 0.68 and 0.73 for pulmonary and systemic blood flow, respectively. Bland-Altman analysis demonstrated a consistent over estimation of cardiac magnetic resonance cardiac output by Fick. The average indexed dose area product for patients undergoing haemodynamics with endomyocardial biopsy was 0.73 (SD ±0.6) Gy*m2/kg. With coronary angiography added, the indexed dose area product was 14.6 (SD ± 7.8) Gy*m2/kg. CONCLUSIONS: Cardiac magnetic resonancemeasurements of cardiac output/index in paediatric orthotopic heart transplant patients have poor concordance with Fick estimates; however, cardiac magnetic resonance has good internal validity and inter-reader reliability. Radiation doses are small for haemodynamics with biopsy and increase exponentially with angiography, identifying a new target for cardiac magnetic resonance imaging.


Asunto(s)
Trasplante de Corazón , Imagen por Resonancia Magnética , Niño , Humanos , Reproducibilidad de los Resultados , Cateterismo Cardíaco , Oximetría/métodos , Gasto Cardíaco/fisiología , Espectroscopía de Resonancia Magnética
2.
Inorg Chem ; 62(12): 4861-4871, 2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-36920788

RESUMEN

Efficient and stable lead-free halide double perovskites (DPs) have attracted great attention for the future generation of electronic devices. Herein, we have developed a doping approach to incorporate Fe3+ ions into the Cs2NaBiCl6 crystal unit and reveal a crystallographic and optoelectronic study of the Cs2NaBi1-xFexCl6 double perovskite. We report a simple solid-state mechanochemical method that has a solvent-free, one-step, green chemistry approach for the synthesis of Cs2NaBi1-xFexCl6 phosphor. The analysis of powder X-ray diffraction (XRD) data determines the contraction of the lattice due to the incorporation of Fe3+ cations, and this effect is well supported by X-ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FE-SEM), Raman spectroscopy, and solid-state nuclear magnetic resonance spectroscopy (ss-NMR). The band gap is reduced with increasing Fe content owing to the strong overlap of the Fe-3d orbitals with Cl-3p orbitals and shift of the valence band maxima (VBM) toward higher energies, as confirmed by ultraviolet photoelectron spectroscopy (UPS) and density functional theory (DFT) analyses. Photoluminescence (PL) studies of Cs2NaBi1-xFexCl6 phosphors exhibit a large Stokes shift, broadband emission, and increased PL intensity more than ten times for 15% of Fe content phosphor with enhancement in the average decay lifetimes (up to 38 ns) compared to pristine Cs2NaBiCl6 DP. These results indicate that the transition of dark self-trapping of excitons (STEs) into bright STEs enhances yellow emission. XRD, UV, and thermo-gravimetric analysis (TGA) confirmed that the Cs2NaB1-xFexCl6 DPs have good structural and thermal stabilities. Our findings indicate that the doping of Fe3+ cations into the Cs2NaBiCl6 lattice is a constructive strategy to enhance significantly the optoelectronic properties of these phosphors.

3.
J Cardiovasc Magn Reson ; 24(1): 58, 2022 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-36352454

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) allows for time-resolved three-dimensional phase-contrast (4D Flow) analysis of congenital heart disease (CHD). Higher spatial resolution in small infants requires thinner slices, which can degrade the signal. Particularly in infants, the choice of contrast agent (ferumoxytol vs. gadolinium) may influence 4D Flow CMR accuracy. Thus, we investigated the accuracy of 4D Flow CMR measurements compared to gold standard 2D flow phase contrast (PC) measurements in ferumoxytol vs. gadolinium-enhanced CMR of small CHD patients with shunt lesions. METHODS: This was a retrospective study consisting of CMR studies from complex CHD patients less than 20 kg who had ferumoxytol or gadolinium-enhanced 4D Flow and standard two-dimensional phase contrast (2D-PC) flow collected. 4D Flow clinical software (Arterys) was used to measure flow in great vessels, systemic veins, and pulmonary veins. 4D Flow accuracy was defined as percent difference or correlation against conventional measurements (2D-PC) from the same vessels. Subgroup analysis was performed on two-ventricular vs single-ventricular CHD, arterial vs venous flow, as well as low flows (defined as < 1.5 L/min) in 1V CHD. RESULTS: Twenty-one ferumoxytol-enhanced and 23 gadolinium-enhanced CMR studies were included, with no difference in age (2.1 ± 1.6 vs. 2.3 ± 1.9 years, p = 0.70), patient body surface area (0.50 ± 0.2 vs. 0.52 ± 0.2 m2, p = 0.67), or vessel diameter (11.4 ± 5.2 vs. 12.4 ± 5.6 mm, p = 0.22). Ten CMR studies with single ventricular CHD were included. Overall, ferumoxytol-enhanced 4D flow CMR measurements demonstrated less percent difference to 2D-PC when compared to gadolinium-enhanced 4D Flow CMR studies. In subgroup analyses of arterial vs. venous flows (high velocity vs. low velocity) and low flow in single ventricle CHD, ferumoxytol-enhanced 4D Flow CMR measurements had stronger correlation to 2D-PC CMR. The contrast-to-noise ratio (CNR) in ferumoxytol-enhanced studies was higher than the CNR in gadolinium-enhanced studies. CONCLUSIONS: Ferumoxytol-enhanced 4D Flow CMR has improved accuracy when compared to gadolinium 4D Flow CMR, particularly for infants with small vessels in CHD.


Asunto(s)
Gadolinio , Cardiopatías Congénitas , Niño , Lactante , Humanos , Óxido Ferrosoférrico , Estudios Retrospectivos , Velocidad del Flujo Sanguíneo , Valor Predictivo de las Pruebas , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Ventrículos Cardíacos , Espectroscopía de Resonancia Magnética , Reproducibilidad de los Resultados
4.
J Cardiovasc Magn Reson ; 24(1): 51, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36192743

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) is emerging as an important tool for cardiac allograft assessment. Native T1 mapping may add value in identifying rejection and in assessing graft dysfunction and myocardial fibrosis burden. We hypothesized that CMR native T1 values and features of textural analysis of T1 maps would identify acute rejection, and in a secondary analysis, correlate with markers of graft dysfunction, and with fibrosis percentage from endomyocardial biopsy (EMB). METHODS: Fifty cases with simultaneous EMB, right heart catheterization, and 1.5 T CMR with breath-held T1 mapping via modified Look-Locker inversion recovery (MOLLI) in 8 short-axis slices and subsequent quantification of mean and peak native T1 values, were performed on 24 pediatric subjects. A single mid-ventricular slice was used for image texture analysis using nine gray-level co-occurrence matrix features. Digital quantification of Masson trichrome stained EMB samples established degree of fibrosis. Markers of graft dysfunction, including serum brain natriuretic peptide levels and hemodynamic measurements from echocardiography, catheterization, and CMR were collated. Subjects were divided into three groups based on degree of rejection: acute rejection requiring new therapy, mild rejection requiring increased ongoing therapy, and no rejection with no change in treatment. Statistical analysis included student's t-test and linear regression. RESULTS: Peak and mean T1 values were significantly associated with acute rejection, with a monotonic trend observed with increased grade of rejection. Texture analysis demonstrated greater spatial heterogeneity in T1 values, as demonstrated by energy, entropy, and variance, in cases requiring treatment. Interestingly, 2 subjects who required increased therapy despite low grade EMB results had abnormal peak T1 values. Peak T1 values also correlated with increased BNP, right-sided filling pressures, and capillary wedge pressures. There was no difference in histopathological fibrosis percentage among the 3 groups; histopathological fibrosis did not correlate with T1 values or markers of graft dysfunction. CONCLUSION: In pediatric heart transplant patients, native T1 values identify acute rejection requiring treatment and may identify graft dysfunction. CMR shows promise as an important tool for evaluation of cardiac grafts in children, with T1 imaging outperforming biopsy findings in the assessment of rejection.


Asunto(s)
Trasplante de Corazón , Niño , Fibrosis , Rechazo de Injerto/diagnóstico por imagen , Rechazo de Injerto/patología , Trasplante de Corazón/efectos adversos , Humanos , Imagen por Resonancia Magnética , Miocardio/patología , Péptido Natriurético Encefálico , Valor Predictivo de las Pruebas , Donantes de Tejidos
5.
Cardiol Young ; 32(5): 718-726, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34348808

RESUMEN

BACKGROUND: A novel paediatric disease, multi-system inflammatory syndrome in children, has emerged during the 2019 coronavirus disease pandemic. OBJECTIVES: To describe the short-term evolution of cardiac complications and associated risk factors in patients with multi-system inflammatory syndrome in children. METHODS: Retrospective single-centre study of confirmed multi-system inflammatory syndrome in children treated from 29 March, 2020 to 1 September, 2020. Cardiac complications during the acute phase were defined as decreased systolic function, coronary artery abnormalities, pericardial effusion, or mitral and/or tricuspid valve regurgitation. Patients with or without cardiac complications were compared with chi-square, Fisher's exact, and Wilcoxon rank sum. RESULTS: Thirty-nine children with median (interquartile range) age 7.8 (3.6-12.7) years were included. Nineteen (49%) patients developed cardiac complications including systolic dysfunction (33%), valvular regurgitation (31%), coronary artery abnormalities (18%), and pericardial effusion (5%). At the time of the most recent follow-up, at a median (interquartile range) of 49 (26-61) days, cardiac complications resolved in 16/19 (84%) patients. Two patients had persistent mild systolic dysfunction and one patient had persistent coronary artery abnormality. Children with cardiac complications were more likely to have higher N-terminal B-type natriuretic peptide (p = 0.01), higher white blood cell count (p = 0.01), higher neutrophil count (p = 0.02), severe lymphopenia (p = 0.05), use of milrinone (p = 0.03), and intensive care requirement (p = 0.04). CONCLUSION: Patients with multi-system inflammatory syndrome in children had a high rate of cardiac complications in the acute phase, with associated inflammatory markers. Although cardiac complications resolved in 84% of patients, further long-term studies are needed to assess if the cardiac abnormalities (transient or persistent) are associated with major cardiac events.


Asunto(s)
COVID-19 , Anomalías Cardiovasculares , Enfermedad de la Arteria Coronaria , Derrame Pericárdico , COVID-19/complicaciones , Niño , Preescolar , Humanos , Derrame Pericárdico/etiología , Estudios Retrospectivos , SARS-CoV-2 , Síndrome de Respuesta Inflamatoria Sistémica
6.
Phys Chem Chem Phys ; 23(15): 9553-9560, 2021 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-33885069

RESUMEN

Cu2ZnGeSe4 (CZGSe) is a promising earth-abundant and non-toxic semiconductor material for large-scale thin-film solar cell applications. Herein, we have employed a joint computational and experimental approach to characterize and assess the structural, optoelectronic, and heterojunction band offset and alignment properties of a CZGSe solar absorber. The CZGSe films were successfully prepared using DC-sputtering and e-beam evaporation systems and confirmed by XRD and Raman spectroscopy analyses. The CZGSe films exhibit a bandgap of 1.35 eV, as estimated from electrochemical cyclic voltammetry (CV) measurements and validated by first-principles density functional theory (DFT) calculations, which predicts a bandgap of 1.38 eV. A fabricated device based on the CZGSe as a light absorber and CdS as a buffer layer yields power conversion efficiency (PCE) of 4.4% with VOC of 0.69 V, FF of 37.15, and Jsc of 17.12 mA cm-2. Therefore, we suggest that interface and band offset engineering represent promising approaches to improve the performance of CZGSe devices by predicting a type-II staggered band alignment with a small conduction band offset of 0.18 eV at the CZGSe/CdS interface.

7.
J Cardiovasc Magn Reson ; 22(1): 11, 2020 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-32013998

RESUMEN

INTRODUCTION: Pediatric z scores are necessary to describe size and structure of the heart in growing children, however, development of an accurate z score calculator requires robust normal datasets, which are difficult to obtain with cardiovascular magnetic resonance (CMR) in children. Motion-corrected (MOCO) cines from re-binned, reconstructed real-time cine offer a free-breathing, rapid acquisition resulting in cines with high spatial and temporal resolution. In combination with child-friendly positioning and entertainment, MOCO cine technique allows for rapid cine volumetry in patients of all ages without sedation. Thus, our aim was to prospectively enroll normal infants and children birth-12 years for creation and validation of a z score calculator describing normal right ventricular (RV) and left ventricular (LV) size. METHODS: With IRB approval and consent/assent, 149 normal children successfully underwent a brief noncontrast CMR on a 1.5 T scanner including MOCO cines in the short axis, and RV and LV volumes were measured. 20% of scans were re-measured for interobserver variability analyses. A general linear modeling (GLM) framework was employed to identify and properly represent the relationship between CMR-based assessments and anthropometric data. Scatter plots of model fit and Akaike's information criteria (AIC) results were used to guide the choice among alternative models. RESULTS: A total of 149 subjects aged 22 days-12 years (average 5.1 ± 3.6 years), with body surface area (BSA) range 0.21-1.63 m2 (average 0.8 ± 0.35 m2) were scanned. All ICC values were > 95%, reflecting excellent agreement between raters. The model that provided the best fit of volume measure to the data included BSA with higher order effects and gender as independent variables. Compared with earlier z score models, there is important additional growth inflection in early toddlerhood with similar z score prediction in later childhood. CONCLUSIONS: Free-breathing, MOCO cines allow for accurate, reliable RV and LV volumetry in a wide range of infants and children while awake. Equations predicting fit between LV and RV normal values and BSA are reported herein for purposes of creating z scores. TRIAL REGISTRATION: clinicaltrials.gov NCT02892136, Registered 7/21/2016.


Asunto(s)
Desarrollo Infantil , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/crecimiento & desarrollo , Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Función Ventricular Derecha , Factores de Edad , Niño , Preescolar , Femenino , Voluntarios Sanos , Humanos , Lactante , Recién Nacido , Masculino , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Valores de Referencia , Reproducibilidad de los Resultados , Vigilia
8.
Pediatr Radiol ; 50(12): 1709-1716, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32696111

RESUMEN

BACKGROUND: The benefits of cardiac magnetic resonance imaging (MRI) in the pediatric population must be balanced with the risk and cost of anesthesia. Segmented imaging using multiple averages attempts to avoid breath-holds requiring general anesthesia; however, cardiorespiratory artifacts and prolonged scan times limit its use. Thus, breath-held imaging with general anesthesia is used in many pediatric centers. The advent of free-breathing, motion-corrected (MOCO) cines by real-time re-binned reconstruction offers reduced anesthesia exposure without compromising image quality. OBJECTIVE: This study evaluates sedation utilization in our pediatric cardiac MR practice before and after clinical introduction of free-breathing MOCO imaging for cine and late gadolinium enhancement. MATERIALS AND METHODS: In a retrospective study, patients referred for a clinical cardiac MR who would typically be offered sedation for their scan (n=295) were identified and divided into two eras, those scanned before the introduction of MOCO cine and late gadolinium enhancement sequences and those scanned following their introduction. Anesthesia use was compared across eras and disease-specific cohorts. RESULTS: The incidence of non-sedation studies performed in children nearly tripled following the introduction of MOCO imaging (25% [pre-MOCO] to 69% [post-MOCO], P<0.01), with the greatest effect in patients with simple congenital heart disease. Eleven percent of the post-MOCO cohort comprised infants younger than 3 months of age who could forgo sedation with the combination of MOCO imaging and a "feed-and-bundle" positioning technique. CONCLUSION: Implementation of cardiac MR with MOCO cine and late gadolinium enhancement imaging in a pediatric population is associated with significantly decreased sedation utilization.


Asunto(s)
Anestesia/estadística & datos numéricos , Medios de Contraste , Gadolinio , Cardiopatías/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Niño , Estudios de Cohortes , Femenino , Corazón/diagnóstico por imagen , Humanos , Masculino , Respiración , Estudios Retrospectivos , Tiempo
9.
Cardiol Young ; 30(6): 852-859, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32456723

RESUMEN

BACKGROUND: Monitoring for acute allograft rejection improves outcomes after cardiac transplantation. Endomyocardial biopsy is the gold standard test defining rejection, but carries risk and has limitations. Cardiac magnetic resonance T2 mapping may be able to predict rejection in adults, but has not been studied in children. Our aim was to evaluate T2 mapping in identifying paediatric cardiac transplant patients with acute rejection. METHODS: Eleven paediatric transplant patients presenting 18 times were prospectively enrolled for non-contrast cardiac magnetic resonance at 1.5 T followed by endomyocardial biopsy. Imaging included volumetry, flow, and T2 mapping. Regions of interest were manually selected on the T2 maps using the middle-third technique in the left ventricular septal and lateral wall in a short-axis and four-chamber slice. Mean and maximum T2 values were compared with Student's t-tests analysis. RESULTS: Five cases of acute rejection were identified in three patients, including two cases of grade 2R on biopsy and three cases of negative biopsy treated for clinical symptoms attributed to rejection (new arrhythmia, decreased exercise capacity). A monotonic trend between increasing T2 values and higher biopsy grades was observed: grade 0R T2 53.4 ± 3 ms, grade 1R T2 54.5 ms ± 3 ms, grade 2R T2 61.3 ± 1 ms. The five rejection cases had significantly higher mean T2 values compared to cases without rejection (58.3 ± 4 ms versus 53 ± 2 ms, p = 0.001). CONCLUSIONS: Cardiac magnetic resonance with quantitative T2 mapping may offer a non-invasive method for screening paediatric cardiac transplant patients for acute allograft rejection. More data are needed to understand the relationship between T2 and rejection in children.


Asunto(s)
Rechazo de Injerto/diagnóstico por imagen , Trasplante de Corazón/efectos adversos , Imagen por Resonancia Cinemagnética , Miocardio/patología , Enfermedad Aguda , Adolescente , Niño , Preescolar , Femenino , Rechazo de Injerto/patología , Humanos , Modelos Logísticos , Masculino , Valor Predictivo de las Pruebas , Trasplante Homólogo , Resultado del Tratamiento , Estados Unidos
10.
Catheter Cardiovasc Interv ; 94(3): 399-408, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31062506

RESUMEN

OBJECTIVES: To determine whether X-ray fused with MRI (XFM) is beneficial for select transcatheter congenital heart disease interventions. BACKGROUND: Complex transcatheter interventions often require three-dimensional (3D) soft tissue imaging guidance. Fusion imaging with live X-ray fluoroscopy can potentially improve and simplify procedures. METHODS: Patients referred for select congenital heart disease interventions were prospectively enrolled. Cardiac MRI data was overlaid on live fluoroscopy for procedural guidance. Likert scale operator assessments of value were recorded. Fluoroscopy time, radiation exposure, contrast dose, and procedure time were compared to matched cases from our institutional experience. RESULTS: Forty-six patients were enrolled. Pre-catheterization, same day cardiac MRI findings indicated intervention should be deferred in nine patients. XFM-guided cardiac catheterization was performed in 37 (median age 8.7 years [0.5-63 years]; median weight 28 kg [5.6-110 kg]) with the following prespecified indications: pulmonary artery (PA) stenosis (n = 13), aortic coarctation (n = 12), conduit stenosis/insufficiency (n = 9), and ventricular septal defect (n = 3). Diagnostic catheterization showed intervention was not indicated in 12 additional cases. XFM-guided intervention was performed in the remaining 25. Fluoroscopy time was shorter for XFM-guided intervention cases compared to matched controls. There was no significant difference in radiation dose area product, contrast volume, or procedure time. Operator Likert scores indicated XFM provided useful soft tissue guidance in all cases and was never misleading. CONCLUSIONS: XFM provides operators with meaningful three-dimensional soft tissue data and reduces fluoroscopy time in select congenital heart disease interventions.


Asunto(s)
Cateterismo Cardíaco , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/terapia , Imagen por Resonancia Magnética , Radiografía Intervencional , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Toma de Decisiones Clínicas , Medios de Contraste/administración & dosificación , Femenino , Fluoroscopía , Humanos , Lactante , Imagen por Resonancia Magnética/efectos adversos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación , Radiografía Intervencional/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Adulto Joven
11.
Paediatr Anaesth ; 29(1): 8-15, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30375141

RESUMEN

Cardiac catheterization is an integral part of medical management for pediatric patients with congenital heart disease. Owing to age and lack of cooperation in children who need this procedure, general anesthesia is typically required. These patients have increased anesthesia risk secondary to cardiac pathology. Furthermore, multiple catheterization procedures result in exposure to harmful ionizing radiation. Magnetic resonance imaging-guided right-heart catheterization offers decreased radiation exposure and diagnostic imaging benefits over traditional fluoroscopy but potentially increases anesthetic complexity and risk. We describe our early experience with anesthetic techniques and challenges for pediatric magnetic resonance imaging-guided right-heart catheterization.


Asunto(s)
Anestesia General/métodos , Cateterismo Cardíaco/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Adolescente , Procedimientos Quirúrgicos Cardíacos/métodos , Niño , Preescolar , Femenino , Fluoroscopía , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Humanos , Masculino , Adulto Joven
12.
Pediatr Radiol ; 49(1): 68-75, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30244412

RESUMEN

BACKGROUND: Myocardial strain is an important measure of cardiac function and can be assessed on cardiac magnetic resonance (MR) through the current gold standard of breath-held segmented steady-state free precession (SSFP) cine imaging. Novel free-breathing techniques have been validated for volumetry and systolic function, allowing for evaluation of sicker and younger children who cannot reliably hold their breath. It is unclear whether strain measurements can be reliably performed on free-breathing, motion-corrected, re-binning cine images. OBJECTIVE: To compare strain analysis from motion-corrected retrospective re-binning images to the breath-held SSFP cine images to explore their validity. MATERIALS AND METHODS: Twenty-five children and young adults, ages (2.1-18.6 years) underwent breath-held and motion-corrected retrospective re-binning cine techniques during the same MR examination on a 1.5-tesla magnet. We measured endocardial end-systolic global circumferential strain and endocardial averaged segmental strain using commercial software (MEDIS QStrain 2.1). We used Pearson correlation coefficients to test agreement across techniques. RESULTS: Analysis was possible in all 25 breath-held and motion-corrected retrospective re-binning studies. Global circumferential strain and endocardial averaged segmental strain obtained by motion-corrected retrospective re-binning compared favorably to breath-held studies. Global circumferential strain linear regression models demonstrated acceptable agreement, with coefficients of determination of 0.75 for breath-held compared to motion-corrected retrospective re-binning (P<0.001) and for endocardial averaged segmental strain comparisons yielded 0.77 for breath-held vs. motion-corrected retrospective re-binning (P<0.001). Bland-Altman assessment demonstrated minimal bias for breath-held compared to motion-corrected retrospective re-binning (mean 2.4 and 1.9, respectively, for global circumferential strain and endocardial averaged segmental strain). CONCLUSION: Free-breathing imaging by motion-corrected retrospective re-binning cine imaging provides adequate spatial and temporal resolution to measure myocardial deformation when compared to the gold-standard breath-held SSFP cine imaging in children with normal or borderline systolic function.


Asunto(s)
Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Adolescente , Contencion de la Respiración , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Estudios Retrospectivos
13.
Pediatr Cardiol ; 40(1): 79-88, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30136135

RESUMEN

Cardiac MR traditionally requires breath-holding for cine imaging. Younger or less stable patients benefit from free-breathing during cardiac MR but current free-breathing cine images can be spatially blurred. Motion corrected re-binning (MOC) is a novel approach that acquires and then reformats real-time images over multiple cardiac cycles with high spatial resolution. The technique was previously limited by reconstruction time but distributed computing has reduced these times. Using this technique, left ventricular volumetry has compared favorably to breath-held balanced steady-state free precession cine imaging (BH), the current gold-standard, however, right ventricular volumetry validation remains incomplete, limiting the applicability of MOC in clinical practice. Fifty subjects underwent cardiac MR for evaluation of right ventricular size and function by end-diastolic (EDV) and end-systolic (ESV) volumetry. Measurements using MOC were compared to those using BH. Pearson correlation coefficients and Bland-Altman plots tested agreement across techniques. Total scan plus reconstruction times were tested for significant differences using paired t-test. Volumes obtained by MOC compared favorably to BH (R = 0.9911 for EDV, 0.9690 for ESV). Combined acquisition and reconstruction time (previously reported) were reduced 37% for MOC, requiring a mean of 5.2 min compared to 8.2 min for BH (p < 0.0001). Right ventricular volumetry compares favorably to BH using MOC image reconstruction, but is obtained in a fraction of the time. Combined with previous validation of its use for the left ventricle, this novel method now offers an alternative imaging approach in appropriate clinical settings.


Asunto(s)
Contencion de la Respiración , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Niño , Preescolar , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Masculino , Reproducibilidad de los Resultados , Volumen Sistólico
14.
Am J Perinatol ; 36(S 02): S22-S28, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31238354

RESUMEN

Despite numerous advances in medical and surgical management, congenital heart disease (CHD) remains the number one cause of death in the first year of life from congenital malformations. The current strategies used to approach improving outcomes in CHD are varied. This article will discuss the recent impact of pulse oximetry screening for critical CHD, describe the contributions of advanced cardiac imaging in the neonate with CHD, and highlight the growing importance of quality improvement and safety programs in the cardiac intensive care unit.


Asunto(s)
Cardiopatías Congénitas/diagnóstico , Corazón/diagnóstico por imagen , Tamizaje Neonatal/métodos , Unidades de Cuidados Coronarios/normas , Ecocardiografía , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Recién Nacido , Unidades de Cuidado Intensivo Neonatal/normas , Imagen por Resonancia Magnética , Tamizaje Neonatal/normas , Oximetría , Mejoramiento de la Calidad , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
Cardiol Young ; 28(2): 329-333, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28847332

RESUMEN

An asymptomatic 6-year-old boy with a history of right lung hypoplasia was referred for cardiology evaluation. Echocardiography demonstrated right pulmonary artery hypoplasia with flow reversal in that vessel. The right pulmonary veins were not visualised in the echocardiogram. Cardiac catheterisation confirmed the diagnosis of scimitar syndrome with a characteristic large vertical vein; however, the right pulmonary veins were found to be atretic with no connection to the heart with decompression through the azygos vein. In all, four systemic to pulmonary arterial collaterals were identified, supplying the right lung, which were occluded using embolization coils. This case demonstrates the potential for progressive stenosis and atresia of the so-called "scimitar vein" without previous surgical instrumentation, and that this can occur without haemodynamic embarrassment or development of pulmonary vascular disease.


Asunto(s)
Anomalías Múltiples , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Arteria Pulmonar/anomalías , Venas Pulmonares/anomalías , Síndrome de Cimitarra/cirugía , Niño , Angiografía por Tomografía Computarizada , Humanos , Masculino , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Síndrome de Cimitarra/diagnóstico
16.
J Cardiovasc Electrophysiol ; 28(5): 517-522, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28245348

RESUMEN

BACKGROUND: Arrhythmia ablation with current techniques is not universally successful. Inadequate ablation lesion formation may be responsible for some arrhythmia recurrences. Periprocedural visualization of ablation lesions may identify inadequate lesions and gaps to guide further ablation and reduce risk of arrhythmia recurrence. METHODS: This feasibility study assessed acute postprocedure ablation lesions by MRI, and correlated these findings with clinical outcomes. Ten pediatric patients who underwent ventricular tachycardia ablation were transferred immediately postablation to a 1.5T MRI scanner and late gadolinium enhancement (LGE) imaging was performed to characterize ablation lesions. Immediate and mid-term arrhythmia recurrences were assessed. RESULTS: Patient characteristics include median age 14 years (1-18 years), median weight 52 kg (11-81 kg), normal cardiac anatomy (n = 6), d-transposition of great arteries post arterial switch repair (n = 2), anomalous coronary artery origin post repair (n = 1), and cardiac rhabdomyoma (n = 1). All patients underwent radiofrequency catheter ablation of ventricular arrhythmia with acute procedural success. LGE was identified at the reported ablation site in 9/10 patients, all arrhythmia-free at median 7 months follow-up. LGE was not visible in 1 patient who had recurrence of frequent premature ventricular contractions within 2 hours, confirmed on Holter at 1 and 21 months post procedure. CONCLUSIONS: Ventricular ablation lesion visibility by MRI in the acute post procedure setting is feasible. Lesions identifiable with MRI may correlate with clinical outcomes. Acute MRI identification of gaps or inadequate lesions may provide the unique temporal opportunity for additional ablation therapy to decrease arrhythmia recurrence.


Asunto(s)
Ablación por Catéter , Ventrículos Cardíacos/cirugía , Imagen por Resonancia Magnética , Taquicardia Ventricular/cirugía , Adolescente , Factores de Edad , Ablación por Catéter/efectos adversos , Niño , Preescolar , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recurrencia , Factores de Riesgo , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
17.
J Cardiovasc Magn Reson ; 19(1): 65, 2017 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-28874164

RESUMEN

BACKGROUND: Children with heart disease may require repeated X-Ray cardiac catheterization procedures, are more radiosensitive, and more likely to survive to experience oncologic risks of medical radiation. Cardiovascular magnetic resonance (CMR) is radiation-free and offers information about structure, function, and perfusion but not hemodynamics. We intend to perform complete radiation-free diagnostic right heart catheterization entirely using CMR fluoroscopy guidance in an unselected cohort of pediatric patients; we report the feasibility and safety. METHODS: We performed 50 CMR fluoroscopy guided comprehensive transfemoral right heart catheterizations in 39 pediatric (12.7 ± 4.7 years) subjects referred for clinically indicated cardiac catheterization. CMR guided catheterizations were assessed by completion (success/failure), procedure time, and safety events (catheterization, anesthesia). Pre and post CMR body temperature was recorded. Concurrent invasive hemodynamic and diagnostic CMR data were collected. RESULTS: During a twenty-two month period (3/2015 - 12/2016), enrolled subjects had the following clinical indications: post-heart transplant 33%, shunt 28%, pulmonary hypertension 18%, cardiomyopathy 15%, valvular heart disease 3%, and other 3%. Radiation-free CMR guided right heart catheterization attempts were all successful using passive catheters. In two subjects with septal defects, right and left heart catheterization were performed. There were no complications. One subject had six such procedures. Most subjects (51%) had undergone multiple (5.5 ± 5) previous X-Ray cardiac catheterizations. Retained thoracic surgical or transcatheter implants (36%) did not preclude successful CMR fluoroscopy heart catheterization. During the procedure, two subjects were receiving vasopressor infusions at baseline because of poor cardiac function, and in ten procedures, multiple hemodynamic conditions were tested. CONCLUSIONS: Comprehensive CMR fluoroscopy guided right heart catheterization was feasible and safe in this small cohort of pediatric subjects. This includes subjects with previous metallic implants, those requiring continuous vasopressor medication infusions, and those requiring pharmacologic provocation. Children requiring multiple, serial X-Ray cardiac catheterizations may benefit most from radiation sparing. This is a step toward wholly CMR guided diagnostic (right and left heart) cardiac catheterization and future CMR guided cardiac intervention. TRIAL REGISTRATION: ClinicalTrials.gov NCT02739087 registered February 17, 2016.


Asunto(s)
Cateterismo Cardíaco/métodos , Cardiopatías/diagnóstico , Imagen por Resonancia Magnética Intervencional , Exposición a la Radiación/prevención & control , Adolescente , Factores de Edad , Niño , Estudios de Factibilidad , Femenino , Cardiopatías/fisiopatología , Hemodinámica , Humanos , Masculino , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos , Factores de Tiempo
19.
J Cardiovasc Magn Reson ; 18: 10, 2016 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-26915830

RESUMEN

BACKGROUND: Traditional cine imaging for cardiac functional assessment requires breath-holding, which can be problematic in some situations. Free-breathing techniques have relied on multiple averages or real-time imaging, producing images that can be spatially and/or temporally blurred. To overcome this, methods have been developed to acquire real-time images over multiple cardiac cycles, which are subsequently motion corrected and reformatted to yield a single image series displaying one cardiac cycle with high temporal and spatial resolution. Application of these algorithms has required significant additional reconstruction time. The use of distributed computing was recently proposed as a way to improve clinical workflow with such algorithms. In this study, we have deployed a distributed computing version of motion corrected re-binning reconstruction for free-breathing evaluation of cardiac function. METHODS: Twenty five patients and 25 volunteers underwent cardiovascular magnetic resonance (CMR) for evaluation of left ventricular end-systolic volume (ESV), end-diastolic volume (EDV), and end-diastolic mass. Measurements using motion corrected re-binning were compared to those using breath-held SSFP and to free-breathing SSFP with multiple averages, and were performed by two independent observers. Pearson correlation coefficients and Bland-Altman plots tested agreement across techniques. Concordance correlation coefficient and Bland-Altman analysis tested inter-observer variability. Total scan plus reconstruction times were tested for significant differences using paired t-test. RESULTS: Measured volumes and mass obtained by motion corrected re-binning and by averaged free-breathing SSFP compared favorably to those obtained by breath-held SSFP (r = 0.9863/0.9813 for EDV, 0.9550/0.9685 for ESV, 0.9952/0.9771 for mass). Inter-observer variability was good with concordance correlation coefficients between observers across all acquisition types suggesting substantial agreement. Both motion corrected re-binning and averaged free-breathing SSFP acquisition and reconstruction times were shorter than breath-held SSFP techniques (p < 0.0001). On average, motion corrected re-binning required 3 min less than breath-held SSFP imaging, a 37% reduction in acquisition and reconstruction time. CONCLUSIONS: The motion corrected re-binning image reconstruction technique provides robust cardiac imaging that can be used for quantification that compares favorably to breath-held SSFP as well as multiple average free-breathing SSFP, but can be obtained in a fraction of the time when using cloud-based distributed computing reconstruction.


Asunto(s)
Cardiopatías/diagnóstico , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Respiración , Volumen Sistólico , Función Ventricular Izquierda , Flujo de Trabajo , Adulto , Algoritmos , Nube Computacional , Estudios de Factibilidad , Femenino , Cardiopatías/patología , Cardiopatías/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto Joven
20.
J Cardiovasc Magn Reson ; 18(1): 72, 2016 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-27788681

RESUMEN

BACKGROUND: Duchenne muscular dystrophy (DMD) is an X-linked, inherited disorder causing dilated cardiomyopathy with variable onset and progression. Currently we lack objective markers of the effect of therapies targeted towards preventing progression of subclinical cardiac disease. Thus, our aim was to compare the ability of native T1 and extracellular volume (ECV) measurements to differentiate risk of myocardial disease in DMD and controls. METHODS: Twenty boys with DMD and 16 age/gender-matched controls without history predisposing to cardiac fibrosis, but with a clinical indication for cardiovascular magnetic resonance (CMR) evaluation, underwent CMR with contrast. Data points collected include left ventricular ejection fraction (LVEF), left ventricular mass, and presence of late gadolinium enhancement (LGE). Native T1, and ECV regional mapping were obtained using both a modified Look-Locker (MOLLI) and saturation recovery single shot sequence (SASHA) on a 1.5T scanner. Using ordinal logistic regression models, controlling for age and LVEF, LGE-free septal we evaluated the ability native T1 and ECV assessments to differentiate levels of cardiomyopathy. RESULTS: Twenty DMD subjects aged 14.4 ± 4 years had an LVEF of 56.3 ± 7.4 %; 12/20 had LGE, all confined to the lateral wall. Sixteen controls aged 16.1 ± 2.2 years had an LVEF 60.4 ± 5.1 % and no LGE. Native T1 and ECV values were significantly higher in the DMD group (p < 0.05) with both MOLLI and SASHA imaging techniques. Native T1 demonstrated a 50 % increase in the ability to predict disease state (control, DMD without fibrosis, DMD with fibrosis). ECV demonstrated only the ability to predict presence of LGE, but could not distinguish between controls and DMD without fibrosis. CONCLUSIONS: LGE-spared regions of boys with DMD have significantly different native T1 and ECV values compared to controls. Native T1 measurements can identify early changes in DMD patients without the presence of LGE and help predict disease severity more effectively than ECV. Native T1 may be a novel outcome measure for early cardiac therapies in DMD and other cardiomyopathies.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Distrofia Muscular de Duchenne/complicaciones , Adolescente , Cardiomiopatía Dilatada/etiología , Cardiomiopatía Dilatada/fisiopatología , Estudios de Casos y Controles , Medios de Contraste/administración & dosificación , Diagnóstico Diferencial , Diseño de Equipo , Humanos , Interpretación de Imagen Asistida por Computador , Modelos Logísticos , Imagen por Resonancia Magnética/instrumentación , Masculino , Distrofia Muscular de Duchenne/diagnóstico , Compuestos Organometálicos/administración & dosificación , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Volumen Sistólico , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA