Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Arthroplasty ; 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38604278

RESUMEN

BACKGROUND: Femoral neck fractures (FNFs) in elderly patients are associated with major morbidity and mortality. The influence of postoperative discharge location on recovery and outcomes after arthroplasty for hip fractures is not well understood. METHODS: A multisite retrospective cohort from 9 academic centers identified patients who had FNF treated with hemiarthroplasty or total hip arthroplasty between 2010 and 2019. Patients who had diagnoses of dementia, stroke, age > 80 years, or high energy fracture were excluded. Discharge location was identified, including home-based health services (HHS), inpatient rehabilitation (IPR), or a skilled nursing facility (SNF). Rates of reoperation, periprosthetic joint infection (PJI), and mortality were compared between cohorts. Multivariate logistic regressions were performed, adjusting for age, American Society of Anesthesiologists (ASA) score, body mass index, sex, and tobacco use. Statistical significance was defined as P < .05. RESULTS: A total of 672 patients (315 HHS, 144 IPR, and 213 SNF) were included in this study. The average follow-up was 30 months. The SNF cohort was significantly older (P < .0001) with higher ASA scores (P < .0001) than the HHS cohort. In a logistic regression model adjusting for age, ASA score, and body mass index, the SNF cohort had higher mortality rates than the HHS cohort (P = .0296) and were more likely to have PJI within 90 days (odds ratio = 4.55, 95% confidence interval = 1.40, 4.74) and within 1 year (odds ratio = 3.08, 95% confidence interval = 1.08, 8.78). Time to PJI was significantly shorter in the SNF cohort (SNF 38 versus HHS 231 days, P = .0155). No differences were seen in dislocation or reoperation rates between the SNF and HHS cohorts. No differences were seen in complication rates between the IPR and HHS cohorts. CONCLUSIONS: Discharge to a SNF after arthroplasty for FNF is associated with increased mortality and higher rates of PJI. Hip fracture care pathways that uniformly discharge patients to SNFs may need to be re-evaluated, and surgeons should consider discharge to home with HHS when possible.

2.
Arch Orthop Trauma Surg ; 144(3): 1211-1220, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38265463

RESUMEN

INTRODUCTION: This study described a deformity induced by medial plating of supracondylar distal femur fractures using plates that are precontoured for other anatomic locations. MATERIALS AND METHODS: OTA/AO 33A fractures were created in 12 sawbone femurs and fixed with either a proximal humerus locking plate (PH), an ipsilateral lateral tibial plateau plate (LTP), or an ipsilateral medial distal tibial plate (MDT). A motion capture system measured changes in length and rotation of the distal femur as the plate was applied. Each plate underwent four trials and the mean and standard deviation (SD) for each measurement was reported. An analysis of variance with post hoc Tukey test compared malreduction measures between plate types. RESULTS: All plates consistently created a varus deformity. There was lateral lengthening with a compensatory medial shortening and an increase in the lateral distal femoral angle. The distal fracture fragment was laterally translated, and internally rotated. The PH plate had significantly greater lateral length (27.39 mm SD 4.78, p = 0.007), shorter medial length (13.57 mm SD 4.99, p = 0.028), greater lateral translation (28.82 mm SD 5.70, p = 0.010) and greater widening of the lateral distal femoral angle (28.54° SD 4.98, p < 0.001) than the LTP and MDT plates. The MDT plate had significantly greater angulation anteriorly (8.40° SD 1.07, p < 0.001) and laterally (7.63° SD 3.10, p = 0.002) than the PH and LTP plates. There was no significant difference between plates in internal rotation (PH: 3.07° SD 2.79; LTP: 2.05° SD 1.05; MDT 3.81° SD 3.56; p = 0.659). CONCLUSION: When dual plating supracondylar distal femur fractures, poor plate positioning and a mismatch between plate contour and the slope of the medial distal femur can lead to varus angulation, internal rotation, and lateral translation or a "reverse golf club deformity". After comparing three types of precontoured plates, the authors recommend initial evaluation of the ipsilateral proximal tibial plate when placing a plate along the medial distal femur. LEVEL OF EVIDENCE: IV.


Asunto(s)
Fracturas Femorales Distales , Fracturas del Fémur , Golf , Humanos , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas , Fémur , Placas Óseas
3.
J Arthroplasty ; 38(7 Suppl 2): S284-S288, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37075907

RESUMEN

BACKGROUND: Traditionally, nondisplaced geriatric femoral neck fractures (FNFs) have undergone operative fixation, while displaced geriatric FNFs have undergone hip arthroplasty. The purpose of this study was to evaluate differences between outcomes in patients with nondisplaced (Garden I and II) fractures and displaced (Garden III and IV) fractures that were treated with arthroplasty. METHODS: This was a retrospective review of patients who had a minimum of 1 year follow-up from nine academic medical centers who underwent arthroplasty for FNFs between 2010 and 2020. Chi-square, Fisher's Exact, and t-tests were used to compare demographics and outcomes between patients who had a displaced fracture and those who had a nondisplaced fracture. We included 1,620 patients, with 131 in the nondisplaced cohort and 1,497 in the displaced cohort. The mean follow-up in the study was 26.4 months. Both groups were similar in terms of demographic variables. RESULTS: At 1-year follow-up, the overall reoperation rate was 7% and was not different between patients who had nondisplaced compared to displaced FNFs who underwent arthroplasty. Heterotopic ossification (HO) was significantly higher in displaced (23.6%) versus nondisplaced fractures (11.7%) (P = .0021). Operative times and blood loss were higher in nondisplaced than displaced fractures that underwent arthroplasty. CONCLUSION: Hip arthroplasty is an excellent treatment option for nondisplaced and displaced geriatric FNFs with relatively low and similar reoperation rates at 1 year. Compared to previously published reoperation rates of internal fixation of nondisplaced FNFs, hip arthroplasty is a reasonable treatment option for nondisplaced FNFs to potentially decrease reoperations in a frail patient population.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo , Fracturas del Cuello Femoral , Humanos , Anciano , Complicaciones Posoperatorias/etiología , Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/efectos adversos , Estudios Retrospectivos , Reoperación , Resultado del Tratamiento , Artroplastia de Reemplazo de Cadera/efectos adversos
4.
Arch Orthop Trauma Surg ; 143(3): 1237-1242, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34757461

RESUMEN

OBJECTIVES: In patients with rotational ankle fracture, we compare the rate of venous thromboembolism development between patients who received chemoprophylaxis vs those patients that received none. DESIGN: Retrospective cohort study. SETTING: Level I trauma center. PATIENTS/PARTICIPANTS: Between 2014 and 2018, we identified 483 patients with rotational ankle fracture that had no VTE risk factors, were under 70 years of age, and had an isolated injury. INTERVENTION: Chemoprophylaxis vs no chemoprophylaxis after open reduction internal fixation of a rotational ankle fracture. MAIN OUTCOME MEASUREMENTS: Development of VTE was the primary outcome. Secondary outcomes included wound problems, infection, hematoma, or non-union. RESULTS: There were 313 patients that received no prophylaxis and 170 patients that received chemoprophylaxis after operative fixation of an isolated ankle fracture. Demographics including age, gender, body mass index, and ASA class were similar between groups. The rate of DVT/PE was 3.5% in those without DVT prophylaxis, and 4.1% in those on DVT prophylaxis with no significant differences found (p = 0.8). There was no significant difference in wound complication (no VTE prophylaxis-3.7% vs VTE prophylaxis-2.5%, p = 0.7) or infection rates (no VTE prophylaxis-3.8% vs VTE prophylaxis 4.1%, p = 1.0) between groups. CONCLUSIONS: No difference was detected in the rate of symptomatic DVT or PE in patients based on chemoprophylaxis. Our results support the conclusion that the use of chemoprophylaxis may remain surgeon preference and based on patient risk factors for VTE development. LEVEL OF EVIDENCE: Level III-retrospective cohort study.


Asunto(s)
Fracturas de Tobillo , Embolia Pulmonar , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/tratamiento farmacológico , Fracturas de Tobillo/complicaciones , Embolia Pulmonar/etiología , Estudios Retrospectivos , Factores de Riesgo , Anticoagulantes/uso terapéutico
5.
Artículo en Inglés | MEDLINE | ID: mdl-37289243

RESUMEN

PURPOSE: To describe and evaluate the serendipitous pelvic binder stress radiographs of lateral compression type (LC) pelvic ring injuries. METHODS: This was a retrospective case series performed at a single, level I academic trauma center from 2016 to 2018. All patients presenting with a minimally displaced LC pelvic ring injury were reviewed (< 10 cm displacement on static pelvic radiographs). Patients with X-rays (XR) in a pelvic binder (EMS stress) and with the pelvic binder removed were included. Pelvic ring stability was determined by attending surgeon evaluation of EMS stress radiographs versus static XR of the pelvis. Patients were treated non-operatively and allowed to weight bear or taken to the operating room for exam under anesthesia (EUA) and potential operative fixation. Clinical success of treatment was determined by evaluation of further displacement at the completion of their most recent follow-up. RESULTS: Thirty-seven patients of the initial 398 reviewed met inclusion criteria. Fourteen of 37 patients (38%) were categorized as stable with no significant pelvis displacement seen on EMS stress and were treated non-operatively without further sequelae (4.6 months mean follow-up). The remaining 23/37 (62%) were treated operatively. Occult instability was identified on EMS stress in 14 (61%) of those 23 patients and the remainder were determined to be unstable based upon fracture pattern or EUA. All patients went on to successful treatment without significant pelvic deformity (7.8 months mean follow-up). CONCLUSION: The EMS stress XR is a valuable, opportunistic evaluation in LC pelvic ring injuries. This evaluation is a useful diagnostic adjunct to alert the provider that additional stress imaging may be indicated to evaluate for occult pelvic ring instability.

6.
J Arthroplasty ; 37(4): 742-747.e2, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34968650

RESUMEN

BACKGROUND: The benefit of total hip arthroplasty (THA) for treatment of osteoarthritis (OA) and femoral neck fractures (FNFs) in the geriatric population is well established. We compare perioperative complications and cost of THA for treatment of OA to hemiarthroplasty (HA) and THA for treatment of FNF. METHODS: Data from the Centers for Medicare & Medicaid Services were used to identify all patients 65 years and older undergoing primary hip arthroplasty between 2013 and 2017. Patients were divided into 3 cohorts: THA for OA (n = 326,313), HA for FNF (n = 223,811), and THA for FNF (n = 25,995). Generalized regressions were used to compare group mortality, 90-day readmission, thromboembolic events, and 90-day episode costs, controlling for age, gender, race, and comorbidities. RESULTS: Compared to patients treated for OA, FNF patients were older and had significantly more comorbidities (all P < .001). Even among the youngest age group (65-69 years) without comorbidities, FNF was associated with a greater risk of mortality at 90 days (THA-FNF odds ratio [OR] 9.3, HA-FNF OR 27.0, P < .001), 1 year (THA-FNF OR 7.8, HA-FNF OR 19.0, P < .001) and 5 years (THA-FNF hazard ratio 4.5, HA-FNF hazard ratio 10.0, P < .001). The average 90-day direct cost was $12,479 and $14,036 greater among THA and HA for FNF respectively compared to THA for OA (all P < .001). CONCLUSION: Among Centers for Medicare & Medicaid Services hip arthroplasty patients, those with an FNF had significantly higher rates of mortality, thromboembolic events, readmission, and greater direct cost. Reimbursement models for arthroplasty should account for the distinctly different perioperative complication and resource utilization for FNF patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Cuello Femoral , Hemiartroplastia , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Cuello Femoral/cirugía , Hemiartroplastia/efectos adversos , Humanos , Medicare , Estudios Retrospectivos , Estados Unidos/epidemiología
7.
Arch Orthop Trauma Surg ; 142(10): 2597-2609, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34097123

RESUMEN

INTRODUCTION: Distal femur fractures are challenging injuries historically associated with high rates of nonunion and varus collapse with operative management. As a result, clinical and research interest in dual plating (DP) of distal femur fractures has seen a dramatic increase in recent years. The purpose of this study was to systematically review the literature regarding vascular anatomy and biomechanics of distal femur fractures treated with DP constructs. MATERIALS AND METHODS: A systematic literature review of two medical databases (PubMed & Scopus) was performed to identify peer-reviewed studies on the anatomy and biomechanics regarding DP of distal femur fractures. A total of 1,001 papers were evaluated and 14 papers met inclusion criteria (6 anatomy and 8 biomechanics). Methodological quality scores were used to assess quality and potential bias in the included studies. RESULTS: In the biomechanical studies, DP constructs demonstrated greater axial and rotational stiffness, as well as less displacement and fewer incidences of failure compared to all other constructs. Vascular studies showed that the femoral artery crosses the mid-shaft femur approximately 16.0-18.8 cm proximal to the adductor tubercle and it is located on average 16.6-31.1 mm from the femoral shaft at this location, suggesting that medial plate application can be achieved safely in the distal femur. The methodological quality of the included studies was good for biomechanical studies (Traa score 79.1; range 53-92.5) and excellent for anatomical studies (QUACs score 81.9; range 69.0-88.5). CONCLUSIONS: Existing biomechanics literature suggests that DP constructs are mechanically stronger than other constructs commonly used in the treatment of distal femur fractures. Furthermore, medial distal femoral anatomy allows for safe application of DP constructs, even in a minimally invasive fashion. Dual plating should be considered for patients with distal femur fractures that have risk factors for instability, varus collapse, or nonunion.


Asunto(s)
Fracturas del Fémur , Fijación Interna de Fracturas , Fenómenos Biomecánicos , Placas Óseas , Fracturas del Fémur/patología , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/métodos , Humanos
8.
J Arthroplasty ; 36(5): 1799-1803, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33303328

RESUMEN

BACKGROUND: Distortion is an intrinsic phenomenon associated with image-intensified fluoroscopy that is both poorly understood and infrequently appreciated by orthopedic surgeons. Little information exists regarding its potential influence on intraoperative parameters during orthopedic surgery, let alone during direct anterior (DA) total hip arthroplasty (THA). The purpose of this study was to quantify the amount of potential error caused by fluoroscopic distortion during DA THA. METHODS: Intra-operative fluoroscopic pelvic images from 74 DA THAs were reviewed by two independent readers. All images were obtained using the same fluoroscopic C-arm unit with a radiopaque grid attached to the image intensifier. The vertical distortion from a straight central horizontal line at the peripheries of images were measured and summed to yield the combined vertical distortion similar to how a surgeon calculates a side to side comparison of limb lengths. Simple linear regression was used to evaluate associations between total distortion and patient demographics, operating theaters, and various operative parameters. RESULTS: The average combined distortion was 10.0mm (range 2.0-20.0mm). There was a significant difference in the average distortion observed in different theaters (P < .001). There was no association between distortion and patient demographics or fluoroscopic time (all, P > .05). CONCLUSION: Fluoroscopic distortion is unpredictable and can cause a substantial amount of error when comparing limb lengths during DA THA. This is a critical finding as this amount of inaccuracy could lead to unintended implant positioning and limb-length discrepancies if unaccounted for.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Fluoroscopía , Prótesis de Cadera/efectos adversos , Humanos , Estudios Retrospectivos
9.
Clin Orthop Relat Res ; 478(12): 2859-2865, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32530895

RESUMEN

BACKGROUND: Precise reduction of a syndesmosis after disruption is critical to improve patient physical function. Intraoperative lateral radiographs of the unaffected ankle are often used in clinical practice as a template for anatomic syndesmotic reduction because sagittal plane malreduction is common. However, there is little data to suggest fibular station, or the position of the fibula in the AP plane on the lateral radiograph, is symmetric side-to-side in patients. QUESTIONS/PURPOSES: (1) Is the position of the fibula in the AP plane (fibular station) on lateral ankle radiographs symmetric in an individual? (2) Do the measurements used to judge the position of the fibula on lateral radiographs have good inter- and intraobserver reliability? METHODS: Over the period from August 2016 to October 2018, we identified 478 patients who presented to an orthopaedic clinic with forefoot and midfoot complaints. Skeletally mature patients with acceptable bilateral lateral ankle radiographs, which are common radiographs obtained for new patients to clinic for any complaint, were included. Based on that, 52% (247 of 478 patients) were included with most (22%, 107 patients) excluded for poor lateral radiographs. The most common diagnosis in the patient cohort was midfoot OA (14%, 35 patients). The median (range) age of the included patients was 54 years (15 to 88), and 65% (159 of 247) of the patients were female. Fibular station, defined as the position of the fibula in the AP plane, and fibular length were measured using a digital ruler and goniometer on lateral radiographs. A paired t-test was used to determine if no difference in fibular station existed between the left and right ankles. With 247 paired-samples, with 80% power and an alpha level of 0.05, we could detect a difference between sides of 0.008 for the posterior ratio, 0.010 for the anterior ratio, and 0.012 for fibular length. Two readers, one fellowship-trained orthopaedic traumatologist and one PGY-4, measured 40 patients to determine the inter- and intraobserver reliability by intraclass correlation coefficient (ICC). RESULTS: The posterior fibular station (mean right 0.147 [σ = 0.056], left 0.145 [σ = 0.054], difference = 0.03 [95% CI 0 to 0.06]; p = 0.59), anterior fibular station (right 0.294 [σ = 0.062], left 0.299 [σ = 0.061], difference = 0.04 [95% CI 0 to 0.08]; p = 0.20), and fibular length (right 0.521 [σ = 0.080], left 0.522 [σ = 0.078], difference = 0.05 [95% CI 0.01 to 0.09]; p = 0.87) ratios did not differ with the numbers available between ankles. Inter- and intraobserver reliability were excellent for the posterior ratio (ICC = 0.928 and ICC = 0.985, respectively) and the anterior ratio (ICC = 0.922 and ICC = 0.929, respectively) and moderate-to-good for the fibular length ratio (ICC = 0.732 and ICC = 0.887, respectively). CONCLUSION: The use of lateral radiographs of the contralateral uninjured ankle appears to be a valid template for determining the position of the fibula in the sagittal plane. However, further prospective studies are required to determine the efficacy of this method in reducing the syndesmosis over other methods that exists. LEVEL OF EVIDENCE: Level III, diagnostic study.


Asunto(s)
Puntos Anatómicos de Referencia , Traumatismos del Tobillo/diagnóstico por imagen , Articulación del Tobillo/diagnóstico por imagen , Peroné/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Traumatismos del Tobillo/fisiopatología , Traumatismos del Tobillo/cirugía , Articulación del Tobillo/fisiopatología , Articulación del Tobillo/cirugía , Femenino , Peroné/fisiopatología , Peroné/cirugía , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Radiografía , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven
10.
J Arthroplasty ; 35(7): 1900-1905, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32241649

RESUMEN

BACKGROUND: Periprosthetic joint infection (PJI) is a devastating complication after total joint arthroplasty, carrying significant economic and personal burden. The goal of this study is to use an established database to analyze socioeconomic variables and assess their relationship to PJI. Additionally, we sought to evaluate whether socioeconomic factors, along with other known risk factors of PJI, when controlled for in a statistical model affected the familial risk of PJI. METHODS: With approval from our Institutional Review Board we performed a population-based retrospective cohort study on all primary total joint arthroplasty cases of the hip or knee (n = 85,332), within a statewide database, between January 1996 and December 2013. We excluded 9854 patients due to age <18 years, missing data, history of PJI prior to index procedure, and no evidence of 2-year follow-up (excluding those with PJI). Cases that developed PJI following the index procedure (n = 2282) were compared to those that did not (n = 73,196). RESULTS: After adjusting for covariates, patients with Medicaid as a primary payer were at greater risk for experiencing PJI (relative risk 1.40, 95% confidence interval [CI] 1.08-1.82, P = .01). There was no difference in risk between the groups associated with education level or median household income (all, P > .05). First-degree relatives of patients who develop PJI (hazard ratio 1.66, 95% CI 1.23-2.24, P = .001) and first-degree and second-degree relatives combined (hazard ratio 1.39, 95% CI 1.09-1.77, P = .007) were at greater risk despite controlling for the above socioeconomic factors. CONCLUSION: Our study provides further support that genetic factors may underlie PJI as we did observe significant familial risk even after accounting for socioeconomic factors and payer status. We did not find a correlation between education level or household income and PJI; however, Medicaid payees were at increased risk. Continued study is needed to define a possible heritable disposition to PJI in an effort to optimize treatment and possibly prevent this complication.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Adolescente , Artroplastia de Reemplazo de Cadera/efectos adversos , Humanos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos , Factores de Riesgo , Clase Social
11.
Injury ; 55(4): 111375, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38290908

RESUMEN

INTRODUCTION: Understanding minimal clinically important differences (MCID) in patient reported outcome measurement are important in improving patient care. The purpose of this study was to determine the MCID of Patient-Reported Outcome Measurement System (PROMIS) Physical Function (PF) domain for patients who underwent operative fixation of a tibial plateau fracture. METHODS: All patients with tibial plateau fractures that underwent operative fixation at a single level 1 trauma center were identified by Current Procedural Terminology codes. Patients without PROMIS PF scores or an anchor question at two-time points postoperatively were excluded. Anchor-based and distribution-based MCIDs were calculated. RESULTS: The MCID for PROMIS PF scores was 4.85 in the distribution-based method and 3.93 (SD 14.01) in the anchor-based method. There was significantly more improvement in the score from the first postoperative score (<7 weeks) to the second postoperative time (<78 weeks) in the improvement group 10.95 (SD 9.95) compared to the no improvement group 7.02 (SD 9.87) in the anchor-based method (P < 0.001). The percentage of patients achieving MCID at 7 weeks, 3 months, 6 months, and 1 year were 37-42 %, 57-62 %, 80-84 %, and 95-87 %, respectively. DISCUSSION: This study identified MCID values for PROMIS PF scores in the tibial plateau fracture population. Both MCID scores were similar, resulting in a reliable value for future studies and clinical decision-making. An MCID of 3.93 to 4.85 can be used as a clinical and investigative standard for patients with operative tibial plateau fractures.


Asunto(s)
Fracturas de la Tibia , Fracturas de la Meseta Tibial , Humanos , Medición de Resultados Informados por el Paciente , Diferencia Mínima Clínicamente Importante , Fracturas de la Tibia/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
12.
J Orthop Trauma ; 38(1): 49-55, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37559208

RESUMEN

OBJECTIVE: To identify technical factors associated with nonunion after operative treatment with lateral locked plating. DESIGN: Retrospective cohort study. SETTING: Ten Level I trauma centers. PATIENT SELECTION CRITERIA: Adult patients with supracondylar distal femur fractures (OTA/AO type 33A or C) treated with lateral locked plating from 2010 through 2019. OUTCOME MEASURES AND COMPARISONS: Surgery for nonunion stratified by risk for nonunion. RESULTS: The cohort included 615 patients with supracondylar distal femur fractures. The median patient age was 61 years old (interquartile range: 46 -72years) and 375 (61%) were female. Observed were nonunion rates of 2% in a low risk of nonunion group (n = 129), 4% in a medium-risk group (n = 333), and 14% in a high-risk group (n = 153). Varus malreduction with an anatomic lateral distal femoral angle greater than 84 degrees, was associated with double the odds of nonunion compared to those without such varus [odds ratio, 2.1; 95% confidence interval (CI), 1.1-4.2; P = 0.03]. Malreduction by medial translation of the articular block increased the odds of nonunion, with 30% increased odds per 4 mm of medial translation (95% CI, 1.0-1.6; P = 0.03). Working length increased the odds of nonunion in the medium risk group, with an 18% increase in nonunion per 10-mm increase in working length (95% CI, 1.0-1.4; P = 0.01). Increased proximal screw density was protective against nonunion (odds ratio, 0.71; 95% CI, 0.53-0.92; P = 0.02) but yielded lower mRUST scores with each 0.1 increase in screw density associated with a 0.4-point lower mRUST (95% CI, -0.55 to -0.15; P < 0.001). Lateral plate length and type of plate material were not associated with nonunion. ( P > 0.05). CONCLUSIONS: Malreduction is a surgeon-controlled variable associated with nonunion after lateral locked plating of supracondylar distal femur fractures. Longer working lengths were associated with nonunion, suggesting that bridge plating may be less likely to succeed for longer fractures. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas Femorales Distales , Fracturas del Fémur , Adulto , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Factores de Riesgo , Fijación Interna de Fracturas/efectos adversos , Placas Óseas/efectos adversos , Fémur
13.
Clin Biomech (Bristol, Avon) ; 101: 105854, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36542910

RESUMEN

BACKGROUND: Large animal fracture models that allow for anatomic fracture fixation are currently lacking. It was hypothesized that a compressed air impaction system can generate a reproducible tibial plafond fracture and be adjustable to create fractures consistent with high and low energy fractures seen in humans. METHODS: Pilot testing of the impaction system was done by impacting polyurethane foam blocks at varying compressed air pressures. A guillotine impaction test was performed on the same foam blocks to create an energy conversion. A total of 12 porcine hindlimb hindlimbs were subjected to low-energy (42.2 J) and high-energy (73.9 J) impact to create tibial plafond fractures. FINDINGS: Guillotine impaction test demonstrated strong correlations between potential energy and foam block impaction depth (R2 = 0.99). Compressed air impaction system test strongly correlated with foam block impaction depth (R2 = 0.99). All six porcine hindlimbs in the low-energy group developed simple coronal split tibial plafond fractures. All six porcine hindlimbs in the high-energy group developed complex, multi-fragmentary tibial plafond fractures. INTERPRETATION: This porcine fracture model created tibial plafond fracture patterns with similar fracture morphology as human patients without violation of the soft tissue structures or adjacent joints. This model would allow for anatomic fixation, the study of post-traumatic osteoarthritis, or the delivery of locally targeted therapeutics to the ankle joint.


Asunto(s)
Fracturas de Tobillo , Fracturas de la Tibia , Humanos , Animales , Porcinos , Fracturas de la Tibia/cirugía , Fracturas de Tobillo/cirugía , Fijación de Fractura , Fijación Interna de Fracturas , Estudios Retrospectivos
14.
J Am Acad Orthop Surg ; 31(8): e451-e458, 2023 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-36727708

RESUMEN

INTRODUCTION: Lateral compression type 1 (LC1) pelvic ring injuries represent a heterogeneous group of fractures with controversial surgical indications. Recently, multiple institutions have suggested the safety and reliability of an emergency department (ED) stress to evaluate for occult instability. The purpose of this study was to correlate ED stress examination of LC1 pelvis fractures against a validated fracture instability scoring system. METHODS: This was a retrospective review of a consecutive series of 70 patients presenting with minimally displaced LC1 fractures at a level 1 academic trauma center. All patients were stressed in the ED radiology suite, and displacement was measured by comparing calibrated stress radiographs with static radiographs (>10 mm displacement defined positivity). ED stress results were compared with radiographic scores assigned according to the validated Beckmann scoring system (score <7: stable-nonsurgical recommendation; score 7 to 9: indeterminant recommendation; and score >9: unstable-surgical recommendation). RESULTS: Thirteen patients had a positive ED stress examination, and 57 patients stressed negative. The mean displacement was significantly different between the three groups (Beckmann 5 to 6: 3.31 mm, SD = 2.4; Beckmann 7 to 9: 4.23 mm, SD = 3.2; Beckmann 10+: 12.1 mm, SD = 8.6; P < 0.001). Zero of 18 patients in the stable group stressed positive, and only 3 of 38 patients in the indeterminant group stressed positive (7.9%). Finally, 10 of 14 patients in the unstable group stressed positive (71.4%; P < 0.001) . Sacral displacement ( P = 0.001), superior ramus location ( P < 0.02), and sacral columns ( P < 0.001) significantly predicted ED stress positivity in multivariate analysis. CONCLUSIONS: Comparison of a validated instability scoring system with ED stress examination of minimally displaced LC1 fractures in awake and hemodynamically stable patients showed excellent correlation. This suggests that the ED stress examination is a useful diagnostic adjunct. LC1 fracture characteristics should be analyzed to determine which pelvic fracture characteristics determine occult instability before stress examination. LEVEL OF EVIDENCE: Level III diagnostic.


Asunto(s)
Fracturas Óseas , Fracturas por Compresión , Huesos Pélvicos , Humanos , Reproducibilidad de los Resultados , Huesos Pélvicos/lesiones , Pelvis , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/cirugía , Estudios Retrospectivos , Centros Traumatológicos
15.
OTA Int ; 6(1): e227, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36760659

RESUMEN

Introduction: Lateral locked plating (LLP) development has improved outcomes for distal femur fractures. However, there is still a modest rate of nonunion in fractures treated with LLP alone, with higher nonunion risk in high-energy fractures, intra-articular involvement, poor bone quality, severe comminution, or bone loss. Several recent studies have demonstrated both the safety and the biomechanical advantage of dual medial and lateral plating (DP). The purpose of this study was to evaluate the clinical outcomes of DP for native distal femoral fractures by performing a systematic review of the literature. Methods: Studies reporting clinical outcomes for DP of native distal femur fractures were identified and systematically reviewed. Publications without full-text manuscripts, those solely involving periprosthetic fractures, or fractures other than distal femur fractures were excluded. Fracture type, mean follow-up, open versus closed fracture, number of bone grafting procedures, nonunion, reoperation rates, and complication data were collected. Methodologic study quality was assessed using the Coleman methodology score. Results: The initial electronic review and reverse inclusion protocol identified 1484 publications. After removal of duplicates and abstract review to exclude studies that did not discuss clinical treatment of femur fractures with dual plating, 101 potential manuscripts were identified and manually reviewed. After final review, 12 studies were included in this study. There were 199 fractures with average follow-up time of 13.72 months. Unplanned reoperations and nonunion occurred in 19 (8.5%) and 9 (4.5%) cases, respectively. The most frequently reported complications were superficial infection (n = 6, 3%) and deep infection (n = 5, 2.5%) postoperatively. Other complications included delayed union (n = 6, 3%) not requiring additional surgical treatment and knee stiffness in four patients (2%) necessitating manipulation under anesthesia or lysis of adhesions. The average Coleman score was 50.5 (range 13.5-72), suggesting that included studies were of moderate-to-poor quality. Conclusions: Clinical research interest in DP of distal femoral fractures has markedly increased in the past few decades. The current data suggest that DP of native distal femoral fractures is associated with favorable nonunion and reoperation rates compared with previously published rates associated with LLP alone. In the current review, DP of distal femoral fractures was associated with acceptable rates of complications and generally good functional outcomes. More high-quality, directly comparable research is necessary to validate the conclusions of this review.

16.
J Orthop Trauma ; 37(1): 44-49, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-35947746

RESUMEN

OBJECTIVES: Compare accessible area of the posterior tibial plateau through a modified posteromedial (PM) approach before and after tenotomy of the medial head gastrocnemius. We report the outcomes of 8 patients who underwent gastrocnemius tenotomy during PM approach. METHODS: A modified PM approach was performed on 10 cadaveric legs, and the surgically accessible area was outlined. Next, a medial head gastrocnemius mid substance tenotomy was completed, and the accessible area was again outlined. Tibia specimens were imaged in a micro-CT scanner to measure accessible surface area and linear distance along the joint line. In addition, 8 patients who underwent tenotomy for tibial plateau fracture had outcomes recorded. RESULTS: The modified PM approach with tenotomy provided significantly more access to the posterior plateau than without tenotomy. The modified PM approach before tenotomy allowed access to 1774 mm 2 (SD = 274) of the posterior plateau surface and 2350 mm 2 (SD = 421, P < 0.0001) with tenotomy. A linear distance of 38 mm (SD = 7) and 57 mm (SD = 7, P < 0.00001) was achieved before and after tenotomy, respectively. In the clinical series, the average knee arc of motion was 116 degrees (95-135). CONCLUSIONS: The modified PM approach with medial head gastrocnemius tenotomy significantly improves surgical access to the posterior plateau. Patients who received tenotomy have acceptable functional outcomes. This cadaveric study provides an alternative approach for treatment of posterolateral tibial plateau fractures which may mitigate damage to neurovascular structures.


Asunto(s)
Tibia , Fracturas de la Tibia , Humanos , Fijación Interna de Fracturas/métodos , Tenotomía , Resultado del Tratamiento , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Cadáver
17.
J Orthop Trauma ; 37(10): 485-491, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37296092

RESUMEN

OBJECTIVE: Compare mortality and complications of distal femur fracture repair among elderly patients who receive operative fixation versus distal femur replacement (DFR). DESIGN: Retrospective comparison. SETTING: Medicare beneficiaries. PATIENTS/PARTICIPANTS: Patients 65 years of age and older with distal femur fracture identified using Center for Medicare & Medicaid Services data from 2016 to 2019. INTERVENTION: Operative fixation (open reduction with plating or intramedullary nail) or DFR. MAIN OUTCOME MEASUREMENTS: Mortality, readmissions, perioperative complications, and 90-day cost were compared between groups using Mahalanobis nearest-neighbor matching to account for differences in age, sex, race, and the Charlson Comorbidity Index. RESULTS: Most patients (90%, 28,251/31,380) received operative fixation. Patients in the fixation group were significantly older (81.1 vs. 80.4 years, P < 0.001), and there were more an open fractures (1.6% vs. 0.5%, P < 0.001). There were no differences in 90-day (difference: 1.2% [-0.5% to 3%], P = 0.16), 6-month (difference: 0.6% [-1.5% to 2.7%], P = 0.59), and 1-year mortality (difference: -3.3% [-2.9 to 2.3], P = 0.80). DFR had greater 90-day (difference: 5.4% [2.8%-8.1%], P < 0.001), 6-month (difference: 6.5% [3.1%-9.9%], P < 0.001), and 1-year readmission (difference: 5.5% [2.2-8.7], P = 0.001). DFR had significantly greater rates of infection, pulmonary embolism, deep vein thrombosis, and device-related complication within 1 year from surgery. DFR ($57,894) was significantly more expensive than operative fixation ($46,016; P < 0.001) during the total 90-day episode. CONCLUSIONS: Elderly patients with distal femur fracture have a 22.5% 1-year mortality rate. DFR was associated with significantly greater infection, device-related complication, pulmonary embolism, deep vein thrombosis, cost, and readmission within 90 days, 6 months, and 1 year of surgery. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas Femorales Distales , Fracturas del Fémur , Embolia Pulmonar , Trombosis de la Vena , Humanos , Anciano , Estados Unidos/epidemiología , Fracturas del Fémur/cirugía , Readmisión del Paciente , Estudios Retrospectivos , Medicare , Fémur/cirugía , Fijación Interna de Fracturas/efectos adversos
18.
Foot Ankle Int ; 44(4): 317-321, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36932665

RESUMEN

BACKGROUND: The time frame in which patients can expect functional improvement after open reduction internal fixation (ORIF) of pilon fractures is unclear. The purpose of this study was to determine the trajectory and rate at which patients' physical function improves up to 2 years postinjury. METHODS: The patients studied sustained a unilateral, isolated pilon fractures (AO/OTA 43B/C) and followed at a level 1 trauma center over a 5-year period (2015-2020). Patient-Reported Outcomes Measurement Information Systems (PROMIS) Physical Function (PF) scores from these patients at defined follow-up times of immediately, 6 weeks, 3 months, 6 months, 1 year, and 2 years after surgery defined the cohorts and were retrospectively studied. RESULTS: There were 160 patients with PROMIS scores immediately postoperatively, 143 patients at 6 weeks, 146 patients at 12 weeks, 97 at 24 weeks, 84 at 1 year, and 45 at 2 years postoperatively. The average PROMIS PF score was 28 immediately postoperatively, 30 at 6 weeks, 36 at 3 months, 40 at 6 months, 41 at 1 year, and 39 at 2 years. There was a significant difference between PROMIS PF scores between 6 weeks and 3 months (P < .001), and between 3 and 6 months (P < .001). Otherwise, no significant differences were detected between consecutive time points. CONCLUSION: Patients with isolated pilon fractures demonstrate the majority of their improvement in terms of physical function between 6 weeks and 6 months postoperatively. No significant difference was detected in PF scores after 6 months postoperatively up to 2 years. Furthermore, the mean PROMIS PF score of patients 2 years after recovery was approximately 1 SD below the population average. This information is helpful in counseling patients and setting expectations for recovery after pilon fractures. LEVEL OF EVIDENCE: Level III, prognostic.


Asunto(s)
Fracturas de Tobillo , Fracturas de la Tibia , Humanos , Estudios Retrospectivos , Fijación Interna de Fracturas , Resultado del Tratamiento , Fracturas de la Tibia/cirugía , Fracturas de Tobillo/cirugía
19.
Injury ; 54(7): 110797, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37169695

RESUMEN

INTRODUCTION: The Reamer Irrigator Aspirator (RIA) is frequently used as a tool for bone graft harvesting procedures. The initial use of this instrument for bone grafting was met with significant blood loss and high transfusion rates. However, the RIA remains an excellent tool to obtain large volumes of viable autologous graft. The aim of this study was to investigate how changes in the technical use of the RIA may affect blood loss. MATERIALS AND METHODS: We conducted a retrospective chart review of all patients who underwent RIA bone graft harvest over a 12-year study period. The patients were divided into two cohorts based upon changes in the technique used to obtain autograft harvest with the RIA. The traditional cohort (2008-2012) connected the RIA to dilation and curettage suction and selected reamer size based on radiographic parameters. The modified cohort (2012-2020) connected the RIA to wall suction, used improved techniques for reamer head sizing, and more diligence was paid toward the time the RIA was suctioning in the canal. Demographic information, surgical details, pre- and post-operative hematocrit (HCT), transfusion rate, intra-operative blood loss, reported volume of graft harvested, and iatrogenic fracture were recorded. RESULTS: 201 patients were included in the study with 61 patients in the traditional and 140 patients in the modified cohorts respectively. The average age was 51 years (range: 18-97) with 107 (53%) males. There was no difference in the demographic data between the two cohorts. No difference was noted between the traditional and modified cohorts in terms of the amount of average graft harvested (54cc vs 51cc; p = 0.34) or major complications (1 vs 2; p = 0.91). However, when comparing the traditional versus modified cohorts the traditional group demonstrated a larger average blood loss (675cc vs 500cc; p=<0.01) and HCT drop (13.7 vs 9.5; p=<0.01) with a higher transfusion rate (44% vs 19%; p = 0.001). CONCLUSION: This series demonstrated a significant improvement in blood loss and transfusion with modified techniques used to obtain autologous bone graft with the RIA. Importantly, these techniques do not appear to limit bone graft harvest yield and can therefore be efficiently implemented without limiting the utility of the RIA.


Asunto(s)
Trasplante Óseo , Fracturas Óseas , Masculino , Humanos , Persona de Mediana Edad , Femenino , Trasplante Óseo/métodos , Estudios Retrospectivos , Recolección de Tejidos y Órganos , Fracturas Óseas/cirugía , Trasplante Autólogo/métodos , Irrigación Terapéutica
20.
BMJ Open ; 13(3): e069070, 2023 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-36944463

RESUMEN

INTRODUCTION: Orthopaedic trauma and fracture care commonly cause perioperative anaemia and associated functional iron deficiency due to a systemic inflammatory state. Modern, strict transfusion thresholds leave many patients anaemic; managing this perioperative anaemia is an opportunity to impact outcomes in orthopaedic trauma surgery. The primary outcome of this pilot study is feasibility for a large randomised controlled trial (RCT) to evaluate intravenous iron therapy (IVIT) to improve patient well-being following orthopaedic injury. Measurements will include rate of participant enrolment, screening failure, follow-up, missing data, adverse events and protocol deviation. METHODS AND ANALYSIS: This single-centre, pilot, double-blind RCT investigates the use of IVIT for acute blood loss anaemia in traumatically injured orthopaedic patients. Patients are randomised to receive either a single dose infusion of low-molecular weight iron dextran (1000 mg) or placebo (normal saline) postoperatively during their hospital stay for trauma management. Eligible subjects include adult patients admitted for lower extremity or pelvis operative fracture care with a haemoglobin of 7-11 g/dL within 7 days postoperatively during inpatient care. Exclusion criteria include history of intolerance to intravenous iron supplementation, active haemorrhage requiring ongoing blood product resuscitation, multiple planned procedures, pre-existing haematologic disorders or chronic inflammatory states, iron overload on screening or vulnerable populations. We follow patients for 3 months to measure the effect of iron supplementation on clinical outcomes (resolution of anaemia and functional iron deficiency), patient-reported outcomes (fatigue, physical function, depression and quality of life) and translational measures of immune cell function. ETHICS AND DISSEMINATION: This study has ethics approval (Oregon Health & Science University Institutional Review Board, STUDY00022441). We will disseminate the findings through peer-reviewed publications and conference presentations. TRIAL REGISTRATION NUMBER: NCT05292001; ClinicalTrials.gov.


Asunto(s)
Anemia , Deficiencias de Hierro , Ortopedia , Adulto , Humanos , Proyectos Piloto , Anemia/tratamiento farmacológico , Anemia/etiología , Hierro/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA