Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 203
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Surg Endosc ; 38(7): 3556-3563, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38727831

RESUMEN

BACKGROUND: Near-infrared fluorescence (NIRF) angiography with intraoperative administration of indocyanine green (ICG) has rapidly disseminated in clinical practice. Another clinically approved, and widely available dye, methylene blue (MB), has up to now not been used for this purpose. Recently, we demonstrated promising results for the real-time evaluation of intestinal perfusion using this dye. The primary aim of this study was to perform a quantitative analysis of bowel perfusion assessment for both ICG and MB. METHODS: Four mature female Landrace pigs underwent laparotomy under general anesthesia. An ischemic bowel loop with five regions of interest (ROIs) with varying levels of perfusion was created in each animal. An intravenous (IV) injection of 0.25 mg/kg-0.50 mg/kg MB was administered after 10 min, followed by NIRF imaging in MB mode and measurement of local lactate levels in all corresponding ROIs. This procedure was repeated in ICG mode (IV dose of 0.2 mg/kg) after 60 min. The quest spectrum fluorescence camera (Quest Medical Imaging, Middenmeer, The Netherlands) was used for NIRF imaging of both MB and ICG. RESULTS: Intraoperative NIRF imaging of bowel perfusion assessment with MB and ICG was successful in all studied animals. Ingress (i/s) levels were calculated and correlated with local lactate levels. Both MB and ICG ingress values showed a significant negative correlation (r = - 0.7709; p = < 0.001; r = - 0.5367, p = 0.015, respectively) with local lactate levels. This correlation was stronger for MB compared to ICG, although ICG analysis showed higher absolute ingress values. CONCLUSION: Our fluorescence quantification analysis validates the potential to use MB for bowel perfusion assessment besides the well-known and widely used ICG. Further human studies are necessary to translate our findings to clinical applications.


Asunto(s)
Colorantes , Verde de Indocianina , Azul de Metileno , Animales , Femenino , Colorantes/administración & dosificación , Porcinos , Intestinos/irrigación sanguínea , Intestinos/diagnóstico por imagen , Angiografía con Fluoresceína/métodos , Imagen Óptica/métodos
2.
Surg Endosc ; 38(7): 3758-3772, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38789623

RESUMEN

BACKGROUND: Hyperspectral imaging (HSI), combined with machine learning, can help to identify characteristic tissue signatures enabling automatic tissue recognition during surgery. This study aims to develop the first HSI-based automatic abdominal tissue recognition with human data in a prospective bi-center setting. METHODS: Data were collected from patients undergoing elective open abdominal surgery at two international tertiary referral hospitals from September 2020 to June 2021. HS images were captured at various time points throughout the surgical procedure. Resulting RGB images were annotated with 13 distinct organ labels. Convolutional Neural Networks (CNNs) were employed for the analysis, with both external and internal validation settings utilized. RESULTS: A total of 169 patients were included, 73 (43.2%) from Strasbourg and 96 (56.8%) from Verona. The internal validation within centers combined patients from both centers into a single cohort, randomly allocated to the training (127 patients, 75.1%, 585 images) and test sets (42 patients, 24.9%, 181 images). This validation setting showed the best performance. The highest true positive rate was achieved for the skin (100%) and the liver (97%). Misclassifications included tissues with a similar embryological origin (omentum and mesentery: 32%) or with overlaying boundaries (liver and hepatic ligament: 22%). The median DICE score for ten tissue classes exceeded 80%. CONCLUSION: To improve automatic surgical scene segmentation and to drive clinical translation, multicenter accurate HSI datasets are essential, but further work is needed to quantify the clinical value of HSI. HSI might be included in a new omics science, namely surgical optomics, which uses light to extract quantifiable tissue features during surgery.


Asunto(s)
Aprendizaje Profundo , Imágenes Hiperespectrales , Humanos , Estudios Prospectivos , Imágenes Hiperespectrales/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Abdomen/cirugía , Abdomen/diagnóstico por imagen , Cirugía Asistida por Computador/métodos
3.
Liver Transpl ; 29(11): 1226-1233, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37728488

RESUMEN

An ischemia-reperfusion injury (IRI) results from a prolonged ischemic insult followed by the restoration of blood perfusion, being a common cause of morbidity and mortality, especially in liver transplantation. At the maximum of the potential damage, IRI is characterized by 2 main phases. The first is the ischemic phase, where the hypoxia and vascular stasis induces cell damage and the accumulation of damage-associated molecular patterns and cytokines. The second is the reperfusion phase, where the local sterile inflammatory response driven by innate immunity leads to a massive cell death and impaired liver functionality. The ischemic time becomes crucial in patients with underlying pathophysiological conditions. It is possible to compare this process to a shooting gun, where the loading trigger is the ischemia period and the firing shot is the reperfusion phase. In this optic, this article aims at reviewing the main ischemic events following the phases of the surgical timeline, considering the consequent reperfusion damage.


Asunto(s)
Hepatopatías , Trasplante de Hígado , Daño por Reperfusión , Humanos , Trasplante de Hígado/efectos adversos , Trasplante de Hígado/métodos , Hígado/irrigación sanguínea , Daño por Reperfusión/etiología , Daño por Reperfusión/metabolismo , Hepatopatías/metabolismo , Inmunidad Innata
4.
J Magn Reson Imaging ; 57(3): 918-927, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35852296

RESUMEN

BACKGROUND: MRI is the reference for the diagnosis of arterial cerebral ischemia, but its role in acute mesenteric ischemia (AMI) is poorly known. PURPOSE: To assess MRI detection of early ischemic bowel lesions in a porcine model of arterial AMI. STUDY TYPE: Prospective/cohort. ANIMAL MODEL: Porcine model of arterial AMI obtained by embolization of the superior mesenteric artery (seven pigs). FIELD STRENGTH/SEQUENCE: A 5-T. T1 gradient-echo-weighted-imaging (WI), half-Fourier-acquisition-single-shot-turbo-spin-echo, T2 turbo-spin-echo, true-fast-imaging-with-steady-precession (True-FISP), diffusion-weighted-echo-planar (DWI). ASSESSMENT: T1-WI, T2-WI, and DWI were performed before and continuously after embolization for 6 hours. The signal intensity (SI) of the ischemic bowel was assessed visually and quantitatively on all sequences. The apparent diffusion coefficient (ADC) was assessed. STATISTICAL TESTS: Paired Student's t-test or Mann-Whitney U-test, significance at P < 0.05. RESULTS: One pig died from non-AMI-related causes. The remaining pigs underwent a median 5 h53 (range 1 h24-6 h01) of ischemia. Visually, the ischemic bowel showed signal hyperintensity on DWI-b800 after a median 85 (57-276) minutes compared to the nonischemic bowel. DWI-b800 SI significantly increased after 2 hours (+19%) and the ADC significant decrease within the first hour (-31%). The ischemic bowel was hyperintense on precontrast T1-WI after a median 87 (70-171) minutes with no significant quantitative changes over time (P = 0.46-0.93). The ischemic bowel was hyperintense on T2-WI in three pigs with a significant SI increase on True-FISP after 1 and 2 hours. DATA CONCLUSION: Changes in SI and ADC can be seen early after the onset of arterial AMI with DWI. The value of T2-WI appears to be limited. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Isquemia Mesentérica , Animales , Porcinos , Isquemia Mesentérica/diagnóstico por imagen , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Isquemia/diagnóstico por imagen , Isquemia/patología , Imagen de Difusión por Resonancia Magnética/métodos
5.
Surg Endosc ; 37(3): 2395-2403, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36443562

RESUMEN

BACKGROUND: Single snapshot imaging of optical properties (SSOP) is a relatively new non-invasive, real-time, contrast-free optical imaging technology, which allows for the real-time quantitative assessment of physiological properties, including tissue oxygenation (StO2). This study evaluates the accuracy of multispectral SSOP in quantifying bowel ischaemia in a preclinical experimental model. METHODS: In six pigs, an ischaemic bowel segment was created by dividing the arcade branches. Five regions of interest (ROIs) were identified on the bowel loop, as follows: ROI 1: central ischaemic; ROI 2: left marginal; ROI 3: left vascularised; ROI 4: right marginal; and ROI 5: right vascularised. The Trident imaging system, specifically developed for real-time tissue oxygenation imaging using SSOP, was used to image before (T0) and after ischaemia induction. Capillary and systemic lactates were measured at each time point (T0, T15, T30, T45, T60), as well as StO2 values acquired by means of SSOP (SSOP-StO2). RESULTS: The mean value of SSOP-StO2 in ROI 1 was 30.08 ± 6.963 and was significantly lower when compared to marginal ROIs (ROI 2 + ROI 4: 45.67 ± 10.02 p = < 0.0001), and to vascularised ROIs (ROI 3 + ROI 5: 48.08 ± 7.083 p = < 0.0001). SSOP-StO2 was significantly correlated with normalised lactates r = - 0.5892 p < 0.0001 and with histology r =- 0.6251 p = 0.0002. CONCLUSION: Multispectral SSOP allows for a contrast-free accurate assessment of small bowel perfusion identifying physiological tissue oxygenation as confirmed with perfusion biomarkers.


Asunto(s)
Intestino Delgado , Ácido Láctico , Porcinos , Animales , Intestino Delgado/diagnóstico por imagen , Imagen Óptica/métodos , Isquemia/diagnóstico por imagen
6.
Surg Endosc ; 37(3): 1901-1915, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36258001

RESUMEN

BACKGROUND: Several pivotal studies and international guidelines on the perioperative management of rectal cancer have been published. However, little is known about the current state of perioperative management of rectal cancer patients in clinical practice worldwide. METHODS: An online survey including 13 questions focusing on key topics related to the perioperative management of patients with rectal cancer was conducted among colorectal surgeons registered within the database of the Research Institute Against Digestive Cancer (IRCAD). RESULTS: A total of 535 respondents from 89 countries participated in the survey. Most surgeons worked in the European region (40.9%). Two hundred and fifty-four respondents (47.5%) performed less than 25% of surgical procedures laparoscopically. The most commonly used definition of the upper limit of the rectum was a fixed distance from the anal verge (23.4%). Magnetic resonance imaging was used to define the upper limit of the rectum by 258 respondents (48.2%). During total mesorectal excision (TME), 301 respondents (56.3%) used a high-tie technique. The most commonly constructed anastomosis was an end-to-end anastomosis (68.2%) with the majority of surgeons performing a leak test intraoperatively (88.9%). A total of 355 respondents (66.4%) constructed a diverting ostomy, and the majority of these surgeons constructed an enterostomy (82%). A total of 208 respondents (39.3%) closed a stoma within 8 weeks. Lastly, 135 respondents (25.2%) introduced a solid diet on postoperative day 1. CONCLUSION: There is considerable heterogeneity in the perioperative management of rectal cancer patients worldwide with several discrepancies between current international practice and recommendations from international guidelines. To achieve worldwide standardization in rectal cancer care, further research is needed to elucidate the cause of this heterogeneity and find ways of improved implementation of best practice recommendations.


Asunto(s)
Neoplasias del Recto , Cirujanos , Humanos , Neoplasias del Recto/cirugía , Recto/cirugía , Canal Anal/cirugía , Encuestas y Cuestionarios
7.
Surg Endosc ; 37(2): 950-957, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36068388

RESUMEN

BACKGROUND: Ischemia at the site of an intestinal anastomosis is one of the most important risk factors for anastomotic leakage (AL). Consequently, adequate intestinal microperfusion is essential for optimal tissue oxygenation and anastomotic healing. As visual inspection of tissue viability does not guarantee an adequate objective evaluation of intestinal microperfusion, surgeons are in dire need of supportive tools to decrease anastomotic leakage after colorectal surgery. METHODS: In this feasibility study, laparoscopic laser speckle contrast imaging (LSCI) was used to evaluate intestinal microperfusion in an experimental ischemic bowel loop model. Both large and small ischemic loops were created from the small intestine of a pig; each loop was divided into 5 regions of interest (ROI) with varying levels of ischemia. Speckle contrast and local capillary lactate (LCL) was measured in all ROIs. RESULTS: Both real-time visualization of intestinal microperfusion and induced perfusion deficits was achieved in all bowel loops. As a result, the emergence of regions of intestinal ischemia could be predicted directly after iatrogenic perfusion limitation, whereas without LSCI signs of decreased intestinal viability could only be seen after 30 minutes. Additionally, a significant relation was found between LCL and LSCI. CONCLUSION: In conclusion, LSCI can achieve real-time intraoperative visualization of intestinal microperfusion deficits, allowing for accurate prediction of long-term postoperative ischemic complications. With this revealing capacity, LSCI could potentially facilitate surgical decision-making when constructing intestinal anastomoses in order to mitigate ischemia-related complications such as AL.


Asunto(s)
Fuga Anastomótica , Laparoscopía , Porcinos , Animales , Fuga Anastomótica/etiología , Imágenes de Contraste de Punto Láser , Anastomosis Quirúrgica/métodos , Laparoscopía/métodos , Complicaciones Posoperatorias/etiología , Perfusión , Isquemia/etiología , Imagen de Perfusión/métodos
8.
Surg Endosc ; 37(9): 6779-6790, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37253870

RESUMEN

BACKGROUND: Intraoperative near-infrared fluorescence imaging (NIRF) with preoperative optical dye administration is a promising technique for quick and easy intraoperative visualization of the ureter and for an improved, real-time assessment of intestinal perfusion. During colorectal surgery, there is a need for simultaneous non-invasive ureteral imaging and bowel perfusion assessment, using one single camera system. The purpose of this study is to investigate the feasibility of simultaneous intestinal perfusion and ureteral imaging using a single commercially available NIRF imaging system. METHODS: Six Landrace pigs underwent laparotomy under general anesthesia in this experiment. An intravenous (IV) dose of 0.2 mg/kg indocyanine green (ICG) was given to assess bowel perfusion. Two pairs received a methylene blue (MB) iv injection of 0.75, 0.50 or 0.25 mg/kg respectively to investigate ureteral visualization. Quest Spectrum Fluorescence Camera (Quest Medical Imaging, Middenmeer, The Netherlands) was used for NIRF imaging. RESULTS: Ureter visualization and bowel perfusion under NIRF imaging was achieved in all animals. All ureters were visible after five to ten minutes and remained clearly visible until the end of every experiment (120-420 min). A mixed model analysis did not show any significant differences neither between the three groups nor over time. Importantly, we demonstrated that bowel perfusion could be visualized with methylene blue (MB) as well. We observed no interference between ICG and MB and a faster washout of MB. CONCLUSION: We successfully demonstrated simultaneous fluorescence angiography with ICG and ureteral imaging with MB in the same surgical procedure, with the same commercially available NIRF imaging equipment. More importantly, we showed that the use MB is adequate for bowel perfusion assessment and ureter visualization with this NIRF imaging system. Besides, MB showed an earlier washout time, which can be clinical beneficial as a repeated dye injection may be necessary during a surgical procedure.


Asunto(s)
Laparoscopía , Uréter , Porcinos , Animales , Laparoscopía/métodos , Uréter/diagnóstico por imagen , Uréter/cirugía , Azul de Metileno , Verde de Indocianina , Perfusión , Imagen Óptica/métodos , Fluorescencia
9.
Surg Endosc ; 37(7): 5472-5481, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37043006

RESUMEN

BACKGROUND: The identification of metastatic lymph nodes is one of the most important prognostic factors in gastrointestinal (GI) cancers. Near-infrared fluorescence (NIRF) imaging has been successfully used in GI tumors to detect the lymphatic pathway and the sentinel lymph node (SLN), facilitating fluorescence image-guided surgery (FIGS) with the purpose to achieve a correct nodal staging. The aim of this study was to analyze the current results of NIRF SLN navigation and lymphography through data collected in the EURO-FIGS registry. METHODS: Prospectively collected data regarding patients and ICG-guided lymphadenectomies were analyzed. Additional analyses were performed to identify predictors of metastatic SLN and determinants of fluorescence positivity and nodal metastases outside the boundaries of standard lymphadenectomies. RESULTS: Overall, 188 patients were included by 18 surgeons from 10 different centers. Colorectal cancer was the most reported pathology (77.7%), followed by gastric (19.1%) and esophageal tumors (3.2%). ICG was injected with higher doses (p < 0.001) via extraparietal side (63.3%), and with higher volumes (p < 0.001) via endoluminal side (36.7%). Overall, NIRF SLN navigation was positive in 75.5% of all cases and 95.5% of positive SLNs were retrieved, with a metastatic rate of 14.7%. NIRF identification of lymph nodes outside standard lymphatic stations occurred in 52.1% of all cases, 43.8% of which were positive for metastatic involvement. Positive NIRF SLN identification was an independent predictor of metastasis outside standard lymphatic stations (OR = 4.392, p = 0.029), while BMI independently predicted metastasis in retrieved SLNs (OR = 1.187, p = 0.013). Lower doses of ICG were protective against NIRF identification outside standard of care lymphadenectomy (OR = 0.596, p = 0.006), while higher volumes of ICG were predictive of metastatic involvement outside standard of care lymphadenectomy (OR = 1.597, p = 0.001). CONCLUSIONS: SLN mapping helps identifying potentially metastatic lymph nodes outside the boundaries of standard lymphadenectomies. The EURO-FIGS registry is a valuable tool to share and analyze European surgeons' practices.


Asunto(s)
Ficus , Neoplasias Gastrointestinales , Linfadenopatía , Ganglio Linfático Centinela , Cirugía Asistida por Computador , Humanos , Ganglio Linfático Centinela/patología , Biopsia del Ganglio Linfático Centinela/métodos , Linfografía , Metástasis Linfática/diagnóstico por imagen , Metástasis Linfática/patología , Verde de Indocianina , Ganglios Linfáticos/patología , Escisión del Ganglio Linfático/métodos , Neoplasias Gastrointestinales/patología , Linfadenopatía/patología , Sistema de Registros
10.
BMC Surg ; 23(1): 203, 2023 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-37454060

RESUMEN

BACKGROUND: The treatment of common bile duct (CBD) stones with minimally invasive surgery (MIS) is more technical demanding than laparoscopic cholecystectomy (LC), especially in patients with history of previous abdominal surgery, cholangitis or cholecystitis. Near-infrared (NIR) cholangiography via systemic or biliary tree administration of indocyanine green (ICG), which enhances the visualization of the biliary tree anatomy, may increase the reassurance of CBD localization. The aim of this study was to identify the benefit of near-infrared cholangiography for laparoscopic common bile duct exploration (LCBDE). METHODS: Three groups of CBD stone patients were included in this retrospective study depending on the surgical methods: 1) open choledocholithotomy (OCC), 2) laparoscopic choledocholithotomy (LCC), and 3) near-infrared cholangiography-assisted laparoscopic choledocholithotomy (NIR-CC). For the NIR-CC group, either 3 ml (concentration: 2.5 mg/mL) of ICG were intravenously administered or 10 ml (concentration: 0.125 mg/mL) of ICG were injected directly into the biliary tree. The enhancement rate of the cystic duct (CD), CBD, the upper and lower margin of the CBD were compared using white light image. RESULTS: A total of 187 patients with a mean age of 68.3 years were included (OCC, n = 56; LCC, n = 110; NIR-CC, n = 21). The rate of previous abdominal surgery was significantly lower in the LCC group. The conversion rate was similar between the LCC and the NIR CC groups (p = 0.746). The postoperative hospital stay was significantly longer in the OCC group. No differences in morbidity and mortality were found between the three groups. In the NIR-CC group, the localization of CBD was as high as 85% compared to 24% with white light imaging. CONCLUSIONS: Near-infrared cholangiography helps increase the chance of success in minimally invasive approaches to CBD stones even in patients with previous abdominal surgeries, without increasing the rate of conversion.


Asunto(s)
Colecistectomía Laparoscópica , Cálculos Biliares , Laparoscopía , Humanos , Anciano , Estudios Retrospectivos , Colangiografía/métodos , Cálculos Biliares/diagnóstico por imagen , Cálculos Biliares/cirugía , Verde de Indocianina , Colecistectomía Laparoscópica/métodos , Conducto Colédoco/diagnóstico por imagen , Conducto Colédoco/cirugía
11.
Molecules ; 28(5)2023 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-36903411

RESUMEN

A series of mono- and bis-polyethylene glycol (PEG)-substituted BF2-azadipyrromethene fluorophores have been synthesized with emissions in the near-infrared region (700-800 nm) for the purpose of fluorescence guided intraoperative imaging; chiefly ureter imaging. The Bis-PEGylation of fluorophores resulted in higher aqueous fluorescence quantum yields, with PEG chain lengths of 2.9 to 4.6 kDa being optimal. Fluorescence ureter identification was possible in a rodent model with the preference for renal excretion notable through comparative fluorescence intensities from the ureters, kidneys and liver. Ureteral identification was also successfully performed in a larger animal porcine model under abdominal surgical conditions. Three tested doses of 0.5, 0.25 and 0.1 mg/kg all successfully identified fluorescent ureters within 20 min of administration which was sustained up to 120 min. 3-D emission heat map imaging allowed the spatial and temporal changes in intensity due to the distinctive peristaltic waves of urine being transferred from the kidneys to the bladder to be identified. As the emission of these fluorophores could be spectrally distinguished from the clinically-used perfusion dye indocyanine green, it is envisaged that their combined use could be a step towards intraoperative colour coding of different tissues.


Asunto(s)
Espectroscopía Infrarroja Corta , Uréter , Porcinos , Animales , Espectroscopía Infrarroja Corta/métodos , Colorantes Fluorescentes/química , Riñón , Vejiga Urinaria , Polietilenglicoles/química , Imagen Óptica/métodos
12.
Ann Surg ; 275(6): 1137-1142, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33074896

RESUMEN

OBJECTIVE: The aim of this study was to develop and validate a prediction score for internal hernia (IH) after Roux-en-Y gastric bypass (RYGB). SUMMARY BACKGROUND DATA: The clinical diagnosis of IH is challenging. A sensitivity of 63% to 92% was reported for computed tomography (CT). METHODS: Consecutive patients admitted for abdominal pain after RYGB and undergoing CT and surgical exploration were included retrospectively. Potential clinical predictors and radiological signs of IH were entered in binary logistic regression analysis to determine a predictive score of surgically confirmed IH in the Geneva training set (January 2006-December 2014), and validated in 3 centers, Geneva (January 2015-December 2017) and Neuchâtel and Strasbourg (January 2012-December 2017). RESULTS: Two hundred twenty-eight patients were included, 80 of whom (35.5%) had surgically confirmed IH, 38 (16.6%) had a negative laparoscopy, and 110 (48.2%) had an alternate diagnosis. In the training set of 61 patients, excess body weight loss >95% (odds ratio [OR] 6.73, 95% confidence interval [CI]: 1.13-39.96), swirl sign (OR 8.93, 95% CI: 2.30-34.70), and free liquid (OR 4.53, 95% CI: 1.08-19.0) were independent predictors of IH. Area under the curve (AUC) of the score was 0.799. In the validation set of 167 patients, AUC was 0.846. A score ≥2 was associated with an IH incidence of 60.7% (34/56), and 5.3% (3/56) had a negative laparoscopy. CONCLUSIONS: The score could be incorporated in the clinical setting. To reduce the risk of delayed IH diagnosis, emergency explorative laparoscopy in patients with a score ≥ 2 should be considered.


Asunto(s)
Derivación Gástrica , Hernia Abdominal , Laparoscopía , Obesidad Mórbida , Derivación Gástrica/efectos adversos , Derivación Gástrica/métodos , Hernia Abdominal/cirugía , Humanos , Hernia Interna , Laparoscopía/métodos , Obesidad Mórbida/complicaciones , Obesidad Mórbida/cirugía , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Pérdida de Peso
13.
Ann Surg ; 275(4): 685-691, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33214476

RESUMEN

BACKGROUND: In recent decades, the use of near-infrared light and fluorescence-guidance during open and laparoscopic surgery has exponentially expanded across various clinical settings. However, tremendous variability exists in how it is performed. OBJECTIVE: In this first published survey of international experts on fluorescence-guided surgery, we sought to identify areas of consensus and nonconsensus across 4 areas of practice: fundamentals; patient selection/preparation; technical aspects; and effectiveness and safety. METHODS: A Delphi survey was conducted among 19 international experts in fluorescence-guided surgery attending a 1-day consensus meeting in Frankfurt, Germany on September 8th, 2019. Using mobile phones, experts were asked to anonymously vote over 2 rounds of voting, with 70% and 80% set as a priori thresholds for consensus and vote robustness, respectively. RESULTS: Experts from 5 continents reached consensus on 41 of 44 statements, including strong consensus that near-infrared fluorescence-guided surgery is both effective and safe across a broad variety of clinical settings, including the localization of critical anatomical structures like vessels, detection of tumors and sentinel nodes, assessment of tissue perfusion and anastomotic leaks, delineation of segmented organs, and localization of parathyroid glands. Although the minimum and maximum safe effective dose of ICG were felt to be 1 to 2 mg and >10 mg, respectively, there was strong consensus that determining the optimum dose, concentration, route and timing of ICG administration should be an ongoing research focus. CONCLUSIONS: Although fluorescence imaging was almost unanimously perceived to be both effective and safe across a broad range of clinical settings, considerable further research remains necessary to optimize its use.


Asunto(s)
Verde de Indocianina , Ganglio Linfático Centinela , Consenso , Técnica Delphi , Humanos , Imagen Óptica/métodos
14.
Surg Endosc ; 36(8): 5840-5853, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35064320

RESUMEN

INTRODUCTION: To assess the current approaches and perioperative treatments of laparoscopic right hemicolectomy (LRHC) and to highlight similarities and differences with international guidelines and scientific evidence, we conducted a survey for surgeons across the globe. METHODS: All digestive and colorectal surgeons registered with the database of the Research Institute against Digestive Cancer (IRCAD) were invited to take part in the survey via email and through the social media networks of IRCAD. RESULTS: There were a total of 440 respondents from 78 countries. Most surgeons worked in the European region (38.6%) followed by the Americas (34.1%), the Eastern Mediterranean region (13.0%), the South-East Asian region (5.9%), the Western Pacific region (4.8%), and Africa (3.2%) respectively. Over half of the respondents performed less than 25% of right hemicolectomies laparoscopically where 4 ports are usually used by 68% of the surgeons. The medial-to-lateral, vessel-first approach is the approach most commonly used (74.1%). The most common extraction site was through a midline incision (53%) and an abdominal drain tube is routinely used by 52% of the surgeons after surgery. A total of 68.6% of the responding surgeons perform the majority of the anastomoses extracorporeally. Finally, we found that the majority of responders (60.7%) routinely used mechanical bowel preparations prior to LRHC. CONCLUSION: Regarding several topics related to LRHC care, a discrepancy was observed between the current medical practice and the recommendations from RCTs and international guidelines and significant regional differences were observed.


Asunto(s)
Laparoscopía , Cirujanos , Colectomía , Humanos , Encuestas y Cuestionarios
15.
Surg Endosc ; 36(1): 826-832, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34741202

RESUMEN

BACKGROUND: Laparoscopic endoscopic cooperative colorectal surgery (LECS-CR) is a promising technique to achieve full-thickness resection of colorectal tumors. This approach has shown good rates of complete resection and low local recurrence, especially for large laterally spreading tumors, which are difficult to remove via endoscopy alone. However, it is often difficult to prevent peritoneal leakage of intestinal content, causing infections and risks of cancer spreading. It was hypothesized that a robotic assistance could make the procedure easier and decrease intestinal fluid leakage. This preclinical trial aims to assess the feasibility of robotic and endoscopic cooperative colorectal surgery (RECS-CR). METHODS: LECS-CR was performed in five female pigs and RECS-CR was also performed in five female pigs. With the animal under general anesthesia, pseudotumors were created on the colonic mucosa at a distance comprised between 20 and 25 cm from the anal verge. Desired resection margins were marked endoscopically and two stay sutures were placed either robotically or laparoscopically. A mucosa-to-submucosa dissection was performed endoscopically along the markings. Complete full-thickness dissection was performed cooperatively. The specimen was withdrawn endoscopically. The colon was closed using a self-fixating running suture. Abdominal contaminations, operating times, complications, and complete resections were evaluated and compared between LECS-CR and RECS-CR. RESULTS: The mean number of colonies of Escherichia coli in the RECS group was significantly lower than in the LECS group (36.7 ± 30.2 vs. 142.2 ± 78.4, respectively, p < 0.05). Operating time was comparable (118 ± 11.2 vs. 98.6 ± 25.7, respectively, p = 0.22). Two stenoses occurred in the LECS group. R0 resection was achieved in all cases. CONCLUSION: This study suggests that RECS-CR is feasible and has the potential to reduce intestinal content leakage, potentially preventing postoperative infections.


Asunto(s)
Neoplasias Colorrectales , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Animales , Neoplasias Colorrectales/cirugía , Estudios de Factibilidad , Femenino , Laparoscopía/métodos , Porcinos , Resultado del Tratamiento
16.
Surg Endosc ; 36(11): 8520-8532, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35836033

RESUMEN

BACKGROUND: Poor anastomotic perfusion can cause anastomotic leaks (AL). Hyperspectral imaging (HSI), previously validated experimentally, provides accurate, real-time, contrast-free intestinal perfusion quantification. Clinical experience with HSI is limited. In this study, HSI was used to evaluate bowel perfusion intraoperatively. METHODS: Fifty-two patients undergoing elective colorectal surgeries for neoplasia (n = 40) or diverticular disease (n = 12), were enrolled. Intestinal perfusion was assessed with HSI (TIVITA®, Diaspective Vision, Am Salzhaff, Germany). This device generates a perfusion heat map reflecting the tissue oxygen saturation (StO2) amount. Prior to anastomose creation, the clinical transection line (CTL) was highlighted on the proximal bowel and imaged with HSI. Upon StO2 heat map evaluation, the hyperspectral transection line (HTL) was identified. In case of CTL/HTL discrepancy > 5 mm, the bowel was always resected at the HTL. HSI outcomes were compared to the clinical ones. RESULTS: AL occurred in one patient who underwent neoadjuvant radiochemotherapy and ultralow anterior resection for rectal cancer. HSI assessment was feasible in all patients, and StO2-values were significantly higher at proximal segments than distal ones. Twenty-six patients showed CTL/HTL discrepancy, and these patients had a lower mean StO2 (54.55 ± 21.30%) than patients without discrepancy (65.10 ± 21.30%, p = 0.000). Patients undergoing neoadjuvant radiochemotherapy showed a lower StO2 (51.41 ± 23.41%) than non-neoadjuvated patients (60.51 ± 24.98%, p = 0.010). CONCLUSION: HSI is useful in detecting intraoperatively marginally perfused segments, for which the clinical appreciation is unreliable. Intestinal vascular supply is lower in patients undergoing neoadjuvant radiochemotherapy, and this novel finding together with the clinical impact of HSI perfusion quantification deserves further investigation in larger trials.


Asunto(s)
Cirugía Colorrectal , Procedimientos Quirúrgicos del Sistema Digestivo , Humanos , Fuga Anastomótica , Anastomosis Quirúrgica/métodos , Perfusión
17.
Surg Endosc ; 36(11): 8549-8559, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36008640

RESUMEN

BACKGROUND: Intraoperative identification of cancerous tissue is fundamental during oncological surgical or endoscopic procedures. This relies on visual assessment supported by histopathological evaluation, implying a longer operative time. Hyperspectral imaging (HSI), a contrast-free and contactless imaging technology, provides spatially resolved spectroscopic analysis, with the potential to differentiate tissue at a cellular level. However, HSI produces "big data", which is impossible to directly interpret by clinicians. We hypothesize that advanced machine learning algorithms (convolutional neural networks-CNNs) can accurately detect colorectal cancer in HSI data. METHODS: In 34 patients undergoing colorectal resections for cancer, immediately after extraction, the specimen was opened, the tumor-bearing section was exposed and imaged using HSI. Cancer and normal mucosa were categorized from histopathology. A state-of-the-art CNN was developed to automatically detect regions of colorectal cancer in a hyperspectral image. Accuracy was validated with three levels of cross-validation (twofold, fivefold, and 15-fold). RESULTS: 32 patients had colorectal adenocarcinomas confirmed by histopathology (9 left, 11 right, 4 transverse colon, and 9 rectum). 6 patients had a local initial stage (T1-2) and 26 had a local advanced stage (T3-4). The cancer detection performance of the CNN using 15-fold cross-validation showed high sensitivity and specificity (87% and 90%, respectively) and a ROC-AUC score of 0.95 (considered outstanding). In the T1-2 group, the sensitivity and specificity were 89% and 90%, respectively, and in the T3-4 group, the sensitivity and specificity were 81% and 93%, respectively. CONCLUSIONS: Automatic colorectal cancer detection on fresh specimens using HSI, using a properly trained CNN is feasible and accurate, even with small datasets, regardless of the local tumor extension. In the near future, this approach may become a useful intraoperative tool during oncological endoscopic and surgical procedures, and may result in precise and non-destructive optical biopsies to support objective and consistent tumor-free resection margins.


Asunto(s)
Neoplasias Colorrectales , Imágenes Hiperespectrales , Humanos , Redes Neurales de la Computación , Algoritmos , Márgenes de Escisión , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/cirugía , Biopsia
18.
Surg Endosc ; 36(6): 4529-4541, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34755235

RESUMEN

INTRODUCTION: The aim of this study was to develop a reliable objective structured assessment of technical skills (OSATS) score for linear-stapled, hand-sewn closure of enterotomy intestinal anastomoses (A-OSATS). MATERIALS AND METHODS: The Delphi methodology was used to create a traditional and weighted A-OSATS score highlighting the more important steps for patient outcomes according to an international expert consensus. Minimally invasive novices, intermediates, and experts were asked to perform a minimally invasive linear-stapled intestinal anastomosis with hand-sewn closure of the enterotomy in a live animal model either laparoscopically or robot-assisted. Video recordings were scored by two blinded raters assessing intrarater and interrater reliability and discriminative abilities between novices (n = 8), intermediates (n = 24), and experts (n = 8). RESULTS: The Delphi process included 18 international experts and was successfully completed after 4 rounds. A total of 4 relevant main steps as well as 15 substeps were identified and a definition of each substep was provided. A maximum of 75 points could be reached in the unweighted A-OSATS score and 170 points in the weighted A-OSATS score respectively. A total of 41 anastomoses were evaluated. Excellent intrarater (r = 0.807-0.988, p < 0.001) and interrater (intraclass correlation coefficient = 0.923-0.924, p < 0.001) reliability was demonstrated. Both versions of the A-OSATS correlated well with the general OSATS and discriminated between novices, intermediates, and experts defined by their OSATS global rating scale. CONCLUSION: With the weighted and unweighted A-OSATS score, we propose a new reliable standard to assess the creation of minimally invasive linear-stapled, hand-sewn anastomoses based on an international expert consensus. Validity evidence in live animal models is provided in this study. Future research should focus on assessing whether the weighted A-OSATS exceeds the predictive capabilities of patient outcomes of the unweighted A-OSATS and provide further validity evidence on using the score on different anastomotic techniques in humans.


Asunto(s)
Competencia Clínica , Procedimientos Quirúrgicos del Sistema Digestivo , Anastomosis Quirúrgica/métodos , Animales , Humanos , Reproducibilidad de los Resultados , Grabación en Video
19.
Surg Innov ; 29(4): 479-487, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35232304

RESUMEN

Fluorescence imaging in colorectal surgery is considered a novel predominantly intraoperative method of ensuring a greater surgical success. The use of fluorescence is linked to advanced tumor visualization and projection of its lymphatics, both vessels and nodes, which results in a higher chance of achieving a total excision. Additionally, iatrogenic complications prove to be reduced using fluorescence during the surgical excision. The combination of fluorescence and artificial intelligence to better facilitate oncological surgery will soon become an established approach in operating rooms worldwide.


Asunto(s)
Cirugía Colorrectal , Procedimientos Quirúrgicos del Sistema Digestivo , Inteligencia Artificial , Fluorescencia , Verde de Indocianina , Imagen Óptica/métodos
20.
Surg Innov ; 29(2): 139-144, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34243695

RESUMEN

Introduction. Gastroduodenal stenting is efficacious and safe in both benign and malignant foregut diseases. Transgastric duodenal stenting has been described and however requires a gastrostomy tube to remain in situ for 4 to 6 weeks post-procedure which can lead to complications. We present a technique for immediate gastric repair using a suture-mediated vascular closure device, without the need for a gastrostomy tube in porcine models. Methods. Percutaneous access into the stomach was achieved using fluoroscopy. Two or 3 Perclose Proglide devices were pre-deployed. The tract was dilated and a wire advanced into the distal duodenum. A 15.5 cm covered enteric stent was delivered through the gastrostomy, deployed and position confirmed. The gastrostomy was closed using Perclose Proglide sutures. Necropsy leak pressure measurement was performed to assess integrity of gastrostomy closure in the porcine models. Results. Two (n = 8) or 3 (n = 2) Perclose Proglide devices were deployed in ten porcine models, with 1 misfire (4.5%). Percutaneous transgastric access and stent delivery was successful in all porcine models. Mean leak pressure in the animals with adequately deployed devices was 219 mmHg (range 172 mmHg-270 mmHg). Conclusion. This study demonstrates percutaneous transgastric duodenal stenting with immediate gastric repair using suture-mediated vascular closure devices is a feasible procedure.


Asunto(s)
Dispositivos de Cierre Vascular , Animales , Gastrostomía/métodos , Stents , Estómago/cirugía , Técnicas de Sutura , Suturas , Porcinos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA