Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Opt Express ; 32(5): 7633-7639, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38439440

RESUMEN

We present an optical parametric chirped-pulse amplification (OPCPA) based on mixed cascaded crystals, taking advantage of the unique parametric phase-matching of lithium triborate (LiB3O5, LBO) and yttrium calcium oxyborate ((YCa4O(BO3)3, YCOB) crystals. The OPCPA properties of LBO at 880 nm and YCOB at 750 nm are studied respectively. After amplification by two LBO and two YCOB crystals, a total signal gain of 108 and spectral bandwidth close to 400 nm is obtained. After accurate dispersion compensation with a grating-pair compressor and chirped mirror compensator, a pulse duration of 9.4 fs is obtained by a SHG-frequency-resolved optical grating (FROG). This approach will be of great significance in high energy amplifier for high peak power few-cycle laser sources.

2.
Opt Lett ; 47(21): 5664-5667, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37219298

RESUMEN

We propose a simple single-shot spatiotemporal measurement technique called coherent modulation imaging for the spatio-spectrum (CMISS), which reconstructs the full three-dimensional high-resolution characteristics of ultrashort pulses based on frequency-space division and coherent modulation imaging. We demonstrated it experimentally by measuring the spatiotemporal amplitude and phase of a single pulse with a spatial resolution of 44 µm and a phase accuracy of 0.04 rad. CMISS has good potential for high-power ultrashort-pulse laser facilities and can measure even spatiotemporally complicated pulses with important applications.

3.
Appl Opt ; 60(32): 10016-10023, 2021 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-34807104

RESUMEN

A single-shot measuring apparatus with optical limiting for temporal pulse contrast of kJ-class petawatt lasers in the nanosecond range is proposed. A temporal linear filter comprising an electro-optical switch, a polarizer, a temporal nonlinear filter composed of cascaded SHG crystals, and a dichromatic mirror are, respectively, used as an optical limiting apparatus for contrast measurement of nanosecond and picosecond pulses to improve dynamic range and temporal resolution. The apparatus has been applied to pulse contrast measurements at the SG-II petawatt facility, achieving a high dynamic range of 1010 and a fast time resolution of 107 ps in the 350 ns range. This technique can also be universally applied to the limiting of the main pulse of varying pulse widths to diagnose pre-pulses during generation and transmission.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA