Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Environ Monit Assess ; 195(9): 1042, 2023 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-37589790

RESUMEN

Worldwide, there has been an increase in the presence of potentially toxic cyanobacterial blooms in drinking water sources and within drinking water treatment plants (DWTPs). The objective of this study is to validate the use of in situ probes for the detection and management of cyanobacterial breakthrough in high and low-risk DWTPs. In situ phycocyanin YSI EXO2 probes were devised for remote control and data logging to monitor the cyanobacteria in raw, clarified, filtered, and treated water in three full-scale DWTPs. An additional probe was installed inside the sludge holding tank to measure the water quality of the surface of the sludge storage tank in a high-risk DWTP. Simultaneous grab samplings were carried out for taxonomic cell counts and toxin analysis. A total of 23, 9, and 4 field visits were conducted at the three DWTPs. Phycocyanin readings showed a 93-fold fluctuation within 24 h in the raw water of the high cyanobacterial risk plant, with higher phycocyanin levels during the afternoon period. These data provide new information on the limitations of weekly or daily grab sampling. Also, different moving averages for the phycocyanin probe readings can be used to improve the interpretation of phycocyanin signal trends. The in situ probe successfully detected high cyanobacterial biovolumes entering the clarification process in the high-risk plant. Grab sampling results revealed high cyanobacterial biovolumes in the sludge for both high and low-risk plants.


Asunto(s)
Cianobacterias , Agua Potable , Ficocianina , Aguas del Alcantarillado , Monitoreo del Ambiente
2.
Risk Anal ; 41(8): 1413-1426, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33103797

RESUMEN

Temporal variations in concentrations of pathogenic microorganisms in surface waters are well known to be influenced by hydrometeorological events. Reasonable methods for accounting for microbial peaks in the quantification of drinking water treatment requirements need to be addressed. Here, we applied a novel method for data collection and model validation to explicitly account for weather events (rainfall, snowmelt) when concentrations of pathogens are estimated in source water. Online in situ ß-d-glucuronidase activity measurements were used to trigger sequential grab sampling of source water to quantify Cryptosporidium and Giardia concentrations during rainfall and snowmelt events at an urban and an agricultural drinking water treatment plant in Quebec, Canada. We then evaluate if mixed Poisson distributions fitted to monthly sampling data ( n = 30 samples) could accurately predict daily mean concentrations during these events. We found that using the gamma distribution underestimated high Cryptosporidium and Giardia concentrations measured with routine or event-based monitoring. However, the log-normal distribution accurately predicted these high concentrations. The selection of a log-normal distribution in preference to a gamma distribution increased the annual mean concentration by less than 0.1-log but increased the upper bound of the 95% credibility interval on the annual mean by about 0.5-log. Therefore, considering parametric uncertainty in an exposure assessment is essential to account for microbial peaks in risk assessment.


Asunto(s)
Criptosporidiosis/parasitología , Agua Potable/parasitología , Giardia , Giardiasis/parasitología , Lluvia , Medición de Riesgo/métodos , Nieve , Ciudades , Criptosporidiosis/prevención & control , Cryptosporidium , Monitoreo del Ambiente , Giardiasis/prevención & control , Humanos , Quebec , Ríos , Microbiología del Agua , Purificación del Agua
3.
Risk Anal ; 41(8): 1396-1412, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33103818

RESUMEN

The identification of appropriately conservative statistical distributions is needed to predict microbial peak events in drinking water sources explicitly. In this study, Poisson and mixed Poisson distributions with different upper tail behaviors were used for modeling source water Cryptosporidium and Giardia data from 30 drinking water treatment plants. Small differences (<0.5-log) were found between the "best" estimates of the mean Cryptosporidium and Giardia concentrations with the Poisson-gamma and Poisson-log-normal models. However, the upper bound of the 95% credibility interval on the mean Cryptosporidium concentrations of the Poisson-log-normal model was considerably higher (>0.5-log) than that of the Poisson-gamma model at four sites. The improper choice of a model may, therefore, mislead the assessment of treatment requirements and health risks associated with the water supply. Discrimination between models using the marginal deviance information criterion (mDIC) was unachievable because differences in upper tail behaviors were not well characterized with available data sets ( n<30 ). Therefore, the gamma and the log-normal distributions fit the data equally well but may predict different risk estimates when they are used as an input distribution in an exposure assessment. The collection of event-based monitoring data and the modeling of larger routine monitoring data sets are recommended to identify appropriately conservative distributions to predict microbial peak events.


Asunto(s)
Criptosporidiosis/parasitología , Agua Potable/parasitología , Giardia/parasitología , Giardiasis/parasitología , Microbiología del Agua , Teorema de Bayes , Criptosporidiosis/prevención & control , Cryptosporidium , Monitoreo del Ambiente/métodos , Giardiasis/prevención & control , Humanos , Oocistos , Distribución de Poisson , Medición de Riesgo/métodos , Purificación del Agua/métodos , Abastecimiento de Agua
4.
J Environ Sci (China) ; 107: 218-229, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34412784

RESUMEN

Detection of SARS-CoV-2 RNA in wastewater is a promising tool for informing public health decisions during the COVID-19 pandemic. However, approaches for its analysis by use of reverse transcription quantitative polymerase chain reaction (RT-qPCR) are still far from standardized globally. To characterize inter- and intra-laboratory variability among results when using various methods deployed across Canada, aliquots from a real wastewater sample were spiked with surrogates of SARS-CoV-2 (gamma-radiation inactivated SARS-CoV-2 and human coronavirus strain 229E [HCoV-229E]) at low and high levels then provided "blind" to eight laboratories. Concentration estimates reported by individual laboratories were consistently within a 1.0-log10 range for aliquots of the same spiked condition. All laboratories distinguished between low- and high-spikes for both surrogates. As expected, greater variability was observed in the results amongst laboratories than within individual laboratories, but SARS-CoV-2 RNA concentration estimates for each spiked condition remained mostly within 1.0-log10 ranges. The no-spike wastewater aliquots provided yielded non-detects or trace levels (<20 gene copies/mL) of SARS-CoV-2 RNA. Detections appear linked to methods that included or focused on the solids fraction of the wastewater matrix and might represent in-situ SARS-CoV-2 to the wastewater sample. HCoV-229E RNA was not detected in the no-spike aliquots. Overall, all methods yielded comparable results at the conditions tested. Partitioning behavior of SARS-CoV-2 and spiked surrogates in wastewater should be considered to evaluate method effectiveness. A consistent method and laboratory to explore wastewater SARS-CoV-2 temporal trends for a given system, with appropriate quality control protocols and documented in adequate detail should succeed.


Asunto(s)
COVID-19 , ARN Viral , Humanos , Laboratorios , Pandemias , SARS-CoV-2 , Aguas Residuales
5.
J Water Health ; 17(5): 701-716, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31638022

RESUMEN

The variability of fecal microorganisms and wastewater micropollutants (WWMPs) loads in relation to influent flow rates was evaluated for a water resource recovery facility (WRRF) in support of a vulnerability assessment of a drinking water source. Incomplete treatment and bypass discharges often occur following intense precipitation events that represent conditions that deviate from normal operation. Parasites, fecal indicator bacteria, and WWMPs concentrations and flow rate were measured at the WRRF influent and effluent during dry and wet weather periods. Influent concentrations were measured to characterize potential bypass concentrations that occur during wet weather. Maximum influent Giardia and C. perfringens loads and maximum effluent Escherichia coli and C. perfringens loads were observed during wet weather. Influent median loads of Cryptosporidium and Giardia were 6.8 log oocysts/day and 7.9 log cysts/day per 1,000 people. Effluent median loads were 3.9 log oocysts/day and 6.3 log cysts/day per 1,000 people. High loads of microbial contaminants can occur during WRRF bypasses following wet weather and increase with increasing flow rates; thus, short-term infrequent events such as bypasses should be considered in vulnerability assessments of drinking water sources in addition to the increased effluent loads during normal operation following wet weather.


Asunto(s)
Eliminación de Residuos Líquidos , Aguas Residuales/química , Purificación del Agua , Animales , Bacterias , Cryptosporidium , Giardia , Parásitos , Aguas Residuales/microbiología , Aguas Residuales/parasitología , Recursos Hídricos
6.
J Environ Manage ; 249: 109386, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31421478

RESUMEN

As one of the major sources of surface water quality impairments, Combined Sewer Overflows (CSOs) are of concern when receiving waters are used for drinking water supplies. Given the large number and variability in CSO discharges and loads, there is a need for a general methodology for estimating discharges for environmental planning and source water protection. Detailed data on CSO flowrates, contaminant concentrations including Total Suspended Solids (TSS), Escherichia coli (E. coli), caffeine (CAF) and acetaminophen (ACE) were used to develop a simple loading model that was then verified using discharge and concentration data from other CSO and stormwater events in the literature. The variability of the parameters within each event was analyzed by normalizing flowrate, concentration and event duration to their respective peak values. The normalized flowrate data indicate that the second decile of the discharge periods was associated with peak flowrates. The dynamic behavior of CSO flowrates can be characterized by a linearly increasing trend and then a logarithmically decreasing trend in terms of normalized values. The samples captured during the first decile of the events were illustrated to be a better representation of peak concentrations of all four contaminants. By analyzing the discharge period in three sections (i.e. 1st decile, 2nd decile and remainder), a semi-probabilistic CSO loading model is proposed for the entire discharge period taking into account the variability of the phenomena. Findings can help water managers and utilities to characterize their source waters for better planning and to more efficiently design sampling campaigns for capturing peak concentrations at drinking water treatment plants.


Asunto(s)
Monitoreo del Ambiente , Purificación del Agua , Escherichia coli , Aguas del Alcantarillado , Calidad del Agua , Abastecimiento de Agua
7.
Crit Rev Microbiol ; 42(3): 384-93, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-25198779

RESUMEN

An increase in food-borne illnesses in the United States has been associated with fresh produce consumption. Irrigation water presents recognized risks for microbial contamination of produce. Water quality criteria rely on indicator bacteria. The objective of this review was to collate and summarize experimental data on the relationships between pathogens and thermotolerant coliform (THT) and/or generic E. coli, specifically focusing on surface fresh waters used in or potentially suitable for irrigation agriculture. We analyzed peer-reviewed publications in which concentrations of E. coli or THT coliforms in surface fresh waters were measured along with concentrations of one or more of waterborne and food-borne pathogenic organisms. The proposed relationships were significant in 35% of all instances and not significant in 65% of instances. Coliform indicators alone cannot provide conclusive, non-site-specific and non-pathogen-specific information about the presence and/or concentrations of most important pathogens in surface waters suitable for irrigation. Standards of microbial water quality for irrigation can rely not only on concentrations of indicators and/or pathogens, but must include references to crop management. Critical information on microbial composition of actual irrigation waters to support criteria of microbiological quality of irrigation waters appears to be lacking and needs to be collected.


Asunto(s)
Escherichia coli/crecimiento & desarrollo , Enfermedades Transmitidas por los Alimentos/microbiología , Agua Dulce/microbiología , Riego Agrícola , Escherichia coli/química , Escherichia coli/aislamiento & purificación , Contaminación de Alimentos/análisis , Agua Dulce/análisis , Calor , Humanos
8.
J Environ Manage ; 174: 62-70, 2016 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27011341

RESUMEN

The quality of a drinking water source depends largely on upstream contaminant discharges. Sewer overflows can have a large influence on downstream drinking water intakes as they discharge untreated or partially treated wastewaters that may be contaminated with pathogens. This study focuses on the quantification of Escherichia coli discharges from combined sewer overflows (CSOs) and the dispersion and diffusion in receiving waters in order to prioritize actions for source water protection. E. coli concentrations from CSOs were estimated from monitoring data at a series of overflow structures and then applied to the 42 active overflow structures between 2009 and 2012 using a simple relationship based upon the population within the drainage network. From these estimates, a transport-dispersion model was calibrated with data from a monitoring program from both overflow structures and downstream drinking water intakes. The model was validated with 15 extreme events such as a large number of overflows (n > 8) or high concentrations at drinking water intakes. Model results demonstrated the importance of the cumulative effects of CSOs on the degradation of water quality downstream. However, permits are typically issued on a discharge point basis and do not consider cumulative effects. Source water protection plans must consider the cumulative effects of discharges and their concentrations because the simultaneous discharge of multiple overflows can lead to elevated E. coli concentrations at a drinking water intake. In addition, some CSOs have a disproportionate impact on peak concentrations at drinking water intakes. As such, it is recommended that the management of CSOs move away from frequency based permitting at the discharge point to focus on the development of comprehensive strategies to reduce cumulative and peak discharges from CSOs upstream of drinking water intakes.


Asunto(s)
Agua Potable/microbiología , Monitoreo del Ambiente/métodos , Escherichia coli/aislamiento & purificación , Heces/microbiología , Aguas del Alcantarillado/microbiología , Microbiología del Agua , Purificación del Agua/métodos , Calidad del Agua
9.
Ecotoxicol Environ Saf ; 120: 409-17, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26122734

RESUMEN

The effects of particulate attached bacteria (PAB) and phycocyanin on the simultaneous biodegradation of a mixture of microcystin-LR, YR, LY, LW, LF and cylindrospermopsin (CYN) was assessed in clarifier sludge of a drinking water treatment plant (DWTP) and in a drinking water source. The biomass from lake water and clarifier sludge was able to degrade all microcystins (MCs) at initial concentrations of 10µgL(-1) with pseudo-first order reaction half-lives ranging from 2.3 to 8.8 days. CYN was degraded only in the sludge with a biodegradation rate of 1.0×10(-1)d(-1) and a half-life of 6.0 days. This is the first study reporting multiple MCs and CYN biodegradation in the coagulation-flocculation sludge of a DWTP. The removal of PAB from the lake water and the sludge prolonged the lag time substantially, such that no biodegradation of MCLY, LW and LF was observed within 24 days. Biodegradation rates were shown to increase in the presence of C-phycocyanin as a supplementary carbon source for indigenous bacteria, a cyanobacterial product that accompanies cyanotoxins during cyanobacteria blooms. MCs in mixtures degraded more slowly (or not at all) than if they were degraded individually, an important outcome as MCs in the environment are often present in mixtures. The results from this study showed that the majority of the bacterial biomass responsible for the biodegradation of cyanotoxins is associated with particles or biological flocs and there is a potential for extreme accumulation of cyanotoxins within the DWTP during a transient bloom.


Asunto(s)
Cianobacterias/metabolismo , Agua Potable/química , Microcistinas/química , Ficocianina/química , Aguas del Alcantarillado/química , Uracilo/análogos & derivados , Alcaloides , Toxinas Bacterianas , Biodegradación Ambiental , Biomasa , Toxinas de Cianobacterias , Agua Potable/microbiología , Floculación , Agua Dulce , Semivida , Lagos/microbiología , Microcistinas/toxicidad , Aguas del Alcantarillado/microbiología , Uracilo/química , Uracilo/toxicidad , Purificación del Agua/métodos
10.
Water Res ; 254: 121374, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38422696

RESUMEN

Intense rainfall and snowmelt events may affect the safety of drinking water, as large quantities of fecal material can be discharged from storm or sewage overflows or washed from the catchment into drinking water sources. This study used ß-d-glucuronidase activity (GLUC) with microbial source tracking (MST) markers: human, bovine, porcine mitochondrial DNA markers (mtDNA) and human-associated Bacteroidales HF183 and chemical source tracking (CST) markers including caffeine, carbamazepine, theophylline and acetaminophen, pathogens (Giardia, Cryptosporidium, adenovirus, rotavirus and enterovirus), water quality indicators (Escherichia coli, turbidity) and hydrometeorological data (flowrate, precipitation) to assess the vulnerability of 3 drinking water intakes (DWIs) and identify sources of fecal contamination. Water samples were collected under baseline, snow and rain events conditions in urban and agricultural catchments (Québec, Canada). Dynamics of E. coli, HF183 and WWMPs were similar during contamination events, and concentrations generally varied over 1 order of magnitude during each event. Elevated human-associated marker levels during events demonstrated that urban DWIs were impacted by recent contamination from an upstream municipal water resource recovery facility (WRRF). In the agricultural catchment, mixed fecal pollution was observed with the occurrences and increases of enteric viruses, human bovine and porcine mtDNA during peak contaminating events. Bovine mtDNA qPCR concentrations were indicative of runoff of cattle-derived fecal pollutants to the DWI from diffuse sources following rain events. This study demonstrated that the suitability of a given MST or CST indicator depend on river and catchment characteristics. The sampling strategy using continuous online GLUC activity coupled with MST and CST markers analysis was a more reliable source indicator than turbidity to identify peak events at drinking water intakes.


Asunto(s)
Criptosporidiosis , Cryptosporidium , Agua Potable , Enterovirus , Animales , Bovinos , Porcinos , Humanos , Escherichia coli , Monitoreo del Ambiente , ADN Mitocondrial , Glucuronidasa
11.
Toxins (Basel) ; 14(6)2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35737071

RESUMEN

Freshwater bodies and, consequently, drinking water treatment plants (DWTPs) sources are increasingly facing toxic cyanobacterial blooms. Even though conventional treatment processes including coagulation, flocculation, sedimentation, and filtration can control cyanobacteria and cell-bound cyanotoxins, these processes may encounter challenges such as inefficient removal of dissolved metabolites and cyanobacterial cell breakthrough. Furthermore, conventional treatment processes may lead to the accumulation of cyanobacteria cells and cyanotoxins in sludge. Pre-oxidation can enhance coagulation efficiency as it provides the first barrier against cyanobacteria and cyanotoxins and it decreases cell accumulation in DWTP sludge. This critical review aims to: (i) evaluate the state of the science of cyanobacteria and cyanotoxin management throughout DWTPs, as well as their associated sludge, and (ii) develop a decision framework to manage cyanobacteria and cyanotoxins in DWTPs and sludge. The review identified that lab-cultured-based pre-oxidation studies may not represent the real bloom pre-oxidation efficacy. Moreover, the application of a common exposure unit CT (residual concentration × contact time) provides a proper understanding of cyanobacteria pre-oxidation efficiency. Recently, reported challenges on cyanobacterial survival and growth in sludge alongside the cell lysis and cyanotoxin release raised health and technical concerns with regards to sludge storage and sludge supernatant recycling to the head of DWTPs. According to the review, oxidation has not been identified as a feasible option to handle cyanobacterial-laden sludge due to low cell and cyanotoxin removal efficacy. Based on the reviewed literature, a decision framework is proposed to manage cyanobacteria and cyanotoxins and their associated sludge in DWTPs.


Asunto(s)
Cianobacterias , Agua Potable , Purificación del Agua , Cianobacterias/metabolismo , Toxinas de Cianobacterias , Microcistinas/metabolismo , Aguas del Alcantarillado/microbiología
12.
Sci Total Environ ; 811: 152060, 2022 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-34861306

RESUMEN

In urban areas served by separate sewerage systems, illicit connections to the storm drain system from residences or commercial establishments are frequent whether these misconnections were made accidentally or deliberately. As a result, untreated and contaminated wastewater enters into storm sewers leading to pollution of receiving waters and non-compliance with water quality standards. Typical procedures for detecting illicit connections to the storm sewer system are time consuming and expensive, especially in a highly urbanised area. In this study, we investigated the use of human wastewater micropollutants WWMPs (caffeine, theophylline, and carbamazepine) and advanced DNA molecular markers (human specific Bacteroides HF183 and mitochondrial DNA) as anthropogenic tracers in order to assist identifying potential cross connections. Water samples from storm outfalls and storm sewer pipes in three urban subcatchments were collected in dry weather from 2013 to 2018. All samples contained various concentrations of these markers especially HF183, caffeine and theophylline, suggesting that the storm pipe system studied is widely contaminated by sanitary sewers. None of the traditional indicators or markers tested is sufficient alone to determine the origin of fecal pollution. In a highly urbanised area, the combination of at least three specific human markers was needed in order to locate the residential section with likely misconnections. The human specific Bacteroides HF183, and theophylline appeared to be the most effective markers (along with E. coli) of crossconnections, whereas carbamazepine can provide an indication of contamination through sanitary sewer exfiltration. A composite sewer cross-connection index was developed, and eight misconnected houses were identified and corrected. The index approach enables the reduction of false positives that could lead to expensive interventions to identify cross-connected households. The results show the multiparameter source tracking toolbox as an effective method to identify sewer cross connections for sustainable storm water management.


Asunto(s)
Monitoreo del Ambiente , Escherichia coli , Heces/química , Humanos , Aguas del Alcantarillado/análisis , Aguas Residuales/análisis , Calidad del Agua
13.
Toxins (Basel) ; 14(11)2022 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-36355999

RESUMEN

Health-related concerns about cyanobacteria-laden sludge of drinking water treatment plants (DWTPs) have been raised in the past few years. Microscopic taxonomy, shotgun metagenomic sequencing, and microcystin (MC) measurement were applied to study the fate of cyanobacteria and cyanotoxins after controlled sludge storage (stagnation) in the dark in a full-scale drinking water treatment plant within 7 to 38 days. For four out of eight dates, cyanobacterial cell growth was observed by total taxonomic cell counts during sludge stagnation. The highest observed cell growth was 96% after 16 days of stagnation. Cell growth was dominated by potential MC producers such as Microcystis, Aphanocapsa, Chroococcus, and Dolichospermum. Shotgun metagenomic sequencing unveiled that stagnation stress shifts the cyanobacterial communities from the stress-sensitive Nostocales (e.g., Dolichospermum) order towards less compromised orders and potential MC producers such as Chroococcales (e.g., Microcystis) and Synechococcales (e.g., Synechococcus). The relative increase of cyanotoxin producers presents a health challenge when the supernatant of the stored sludge is recycled to the head of the DWTP or discharged into the source. These findings emphasize the importance of a strategy to manage cyanobacteria-laden sludge and suggest practical approaches should be adopted to control health/environmental impacts of cyanobacteria and cyanotoxins in sludge.


Asunto(s)
Cianobacterias , Agua Potable , Microcystis , Purificación del Agua , Aguas del Alcantarillado , Microcistinas , Cianobacterias/genética
14.
Toxins (Basel) ; 14(10)2022 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-36287957

RESUMEN

The excessive proliferation of cyanobacteria in surface waters is a widespread problem worldwide, leading to the contamination of drinking water sources. Short- and long-term solutions for managing cyanobacterial blooms are needed for drinking water supplies. The goal of this research was to investigate the cyanobacteria community composition using shotgun metagenomics in a short term, in situ mesocosm experiment of two lakes following their coagulation with ferric sulfate (Fe2(SO4)3) as an option for source water treatment. Among the nutrient paramenters, dissolved nitrogen was related to Microcystis in both Missisquoi Bay and Petit Lac St. François, while the presence of Synechococcus was related to total nitrogen, dissolved nitrogen, dissolved organic carbon, and dissolved phosphorus. Results from the shotgun metagenomic sequencing showed that Dolichospermum and Microcystis were the dominant genera in all of the mesocosms in the beginning of the sampling period in Missisquoi Bay and Petit Lac St. François, respectively. Potentially toxigenic genera such as Microcystis were correlated with intracellular microcystin concentrations. A principal component analysis showed that there was a change of the cyanobacterial composition at the genus level in the mesocosms after two days, which varied across the studied sites and sampling time. The cyanobacterial community richness and diversity did not change significantly after its coagulation by Fe2(SO4)3 in all of the mesocosms at either site. The use of Fe2(SO4)3 for an onsite source water treatment should consider its impact on cyanobacterial community structure and the reduction of toxin concentrations.


Asunto(s)
Cianobacterias , Agua Potable , Microcystis , Microcistinas/análisis , Agua Potable/análisis , Cianobacterias/genética , Microcystis/genética , Lagos/microbiología , Nitrógeno/análisis , Fósforo/análisis
15.
Water Res ; 200: 117296, 2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-34098267

RESUMEN

A monitoring strategy was implemented at two drinking water treatment plants in Quebec, Canada, to evaluate microbial reduction performances of full-scale treatment processes under different source water conditions. ß-D-glucuronidase activity in source water was automatically monitored in near-real-time to establish baseline and event conditions at each location. High-volume water samples (50-1,500 L) were collected at the inflow and the outflow of coagulation/flocculation, filtration, and UV disinfection processes and were analysed for two naturally occurring surrogate organisms: Escherichia coli and Clostridium perfringens. Source water Cryptosporidium data and full-scale C. perfringens reduction data were entered into a quantitative microbial risk assessment (QMRA) model to estimate daily infection risks associated with exposures to Cryptosporidium via consumption of treated drinking water. Daily mean E. coli and Cryptosporidium concentrations in source water under event conditions were in the top 5% (agricultural site) or in the top 15% (urban site) of what occurs through the year at these drinking water treatment plants. Reduction performances of up to 6.0-log for E. coli and 5.6-log for C. perfringens were measured by concentrating high-volume water samples throughout the treatment train. For both drinking water treatment plants, removal performances by coagulation/flocculation/sedimentation processes were at the high end of the range of those reported in the literature for bacteria and bacterial spores. Reductions of E. coli and C. perfringens by floc blanket clarification, ballasted clarification and rapid sand filtration did not deteriorate during two snowmelt/rainfall events. QMRA results suggested that daily infection risks were similar during two rainfall/snowmelt events than during baseline conditions. Additional studies investigating full-scale reductions would be desirable to improve the evaluation of differences in treatment performances under various source water conditions.


Asunto(s)
Criptosporidiosis , Cryptosporidium , Agua Potable , Purificación del Agua , Canadá , Escherichia coli , Humanos , Quebec , Microbiología del Agua
16.
Toxins (Basel) ; 13(11)2021 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-34822537

RESUMEN

Cyanobacterial blooms are a global concern. Chemical coagulants are used in water treatment to remove contaminants from the water column and could potentially be used in lakes and reservoirs. The aims of this study was to: 1) assess the efficiency of ferric sulfate (Fe2(SO4)3) coagulant in removing harmful cyanobacterial cells from lake water with cyanobacterial blooms on a short time scale, 2) determine whether some species of cyanobacteria can be selectively removed, and 3) determine the differential impact of coagulants on intra- and extra-cellular toxins. Our main results are: (i) more than 96% and 51% of total cyanobacterial cells were removed in mesocosms with applied doses of 35 mgFe/L and 20 mgFe/L, respectively. Significant differences in removing total cyanobacterial cells and several dominant cyanobacteria species were observed between the two applied doses; (ii) twelve microcystins, anatotoxin-a (ANA-a), cylindrospermopsin (CYN), anabaenopeptin A (APA) and anabaenopeptin B (APB) were identified. Ferric sulfate effectively removed the total intracellular microcystins (greater than 97% for both applied doses). Significant removal of extracellular toxins was not observed after coagulation with both doses. Indeed, the occasional increase in extracellular toxin concentration may be related to cells lysis during the coagulation process. No significant differential impact of dosages on intra- and extra-cellular toxin removal was observed which could be relevant to source water applications where optimal dosing is difficult to achieve.


Asunto(s)
Antibacterianos/farmacología , Toxinas de Cianobacterias/química , Cianobacterias/efectos de los fármacos , Compuestos Férricos/farmacología , Lagos/microbiología , Cianobacterias/química
17.
Water Res X ; 11: 100091, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33598650

RESUMEN

This study investigates short-term fluctuations in virus concentrations in source water and their removal by full-scale drinking water treatment processes under different source water conditions. Transient peaks in raw water faecal contamination were identified using in situ online ß-d-glucuronidase activity monitoring at two urban drinking water treatment plants. During these peaks, sequential grab samples were collected at the source and throughout the treatment train to evaluate concentrations of rotavirus, adenovirus, norovirus, enterovirus, JC virus, reovirus, astrovirus and sapovirus by reverse transcription and real-time quantitative PCR. Virus infectivity was assessed through viral culture by measurement of cytopathic effect and integrated cell culture qPCR. Virus concentrations increased by approximately 0.5-log during two snowmelt/rainfall episodes and approximately 1.0-log following a planned wastewater discharge upstream of the drinking water intake and during a ß-d-glucuronidase activity peak in dry weather conditions. Increases in the removal of adenovirus and rotavirus by coagulation/flocculation processes were observed during peak virus concentrations in source water, suggesting that these processes do not operate under steady-state conditions but dynamic conditions in response to source water conditions. Rotavirus and enterovirus detected in raw and treated water samples were predominantly negative in viral culture. At one site, infectious adenoviruses were detected in raw water and water treated by a combination of ballasted clarification, ozonation, GAC filtration, and UV disinfection operated at a dose of 40 mJ cm-2. The proposed sampling strategy can inform the understanding of the dynamics associated with virus concentrations at drinking water treatment plants susceptible to de facto wastewater reuse.

18.
Toxins (Basel) ; 13(1)2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33401450

RESUMEN

Conventional processes (coagulation, flocculation, sedimentation, and filtration) are widely used in drinking water treatment plants and are considered a good treatment strategy to eliminate cyanobacterial cells and cell-bound cyanotoxins. The diversity of cyanobacteria was investigated using taxonomic cell counts and shotgun metagenomics over two seasons in a drinking water treatment plant before, during, and after the bloom. Changes in the community structure over time at the phylum, genus, and species levels were monitored in samples retrieved from raw water (RW), sludge in the holding tank (ST), and sludge supernatant (SST). Aphanothece clathrata brevis, Microcystis aeruginosa, Dolichospermum spiroides , and Chroococcus minimus were predominant species detected in RW by taxonomic cell counts. Shotgun metagenomics revealed that Proteobacteria was the predominant phylum in RW before and after the cyanobacterial bloom. Taxonomic cell counts and shotgun metagenomic showed that the Dolichospermum bloom occurred inside the plant. Cyanobacteria and Bacteroidetes were the major bacterial phyla during the bloom. Shotgun metagenomics also showed that Synechococcus, Microcystis , and Dolichospermum were the predominant detected cyanobacterial genera in the samples. Conventional treatment removed more than 92% of cyanobacterial cells but led to cell accumulation in the sludge up to 31 times more than in the RW influx. Coagulation/sedimentation selectively removed more than 96% of Microcystis and Dolichospermum. Cyanobacterial community in the sludge varied from raw water to sludge during sludge storage (1-13 days). This variation was due to the selective removal of coagulation/sedimentation as well as the accumulation of captured cells over the period of storage time. However, the prediction of the cyanobacterial community composition in the SST remained a challenge. Among nutrient parameters, orthophosphate availability was related to community profile in RW samples, whereas communities in ST were influenced by total nitrogen, Kjeldahl nitrogen (N- Kjeldahl), total and particulate phosphorous, and total organic carbon (TOC). No trend was observed on the impact of nutrients on SST communities. This study profiled new health-related, environmental, and technical challenges for the production of drinking water due to the complex fate of cyanobacteria in cyanobacteria-laden sludge and supernatant.


Asunto(s)
Toxinas Bacterianas/química , Biodiversidad , Cianobacterias/clasificación , Agua Potable/química , Aguas del Alcantarillado/microbiología , Purificación del Agua , Agua Potable/microbiología , Instalaciones de Eliminación de Residuos
19.
Water Res ; 205: 117707, 2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34619609

RESUMEN

Minimum treatment requirements are set in response to established or anticipated levels of enteric pathogens in the source water of drinking water treatment plants (DWTPs). For surface water, contamination can be determined directly by monitoring reference pathogens or indirectly by measuring fecal indicators such as Escherichia coli (E. coli). In the latter case, a quantitative interpretation of E. coli for estimating reference pathogen concentrations could be used to define treatment requirements. This study presents the statistical analysis of paired E. coli and reference protozoa (Cryptosporidium, Giardia) data collected monthly for two years in source water from 27 DWTPs supplied by rivers in Canada. E. coli/Cryptosporidium and E. coli/Giardia ratios in source water were modeled as the ratio of two correlated lognormal variables. To evaluate the potential of E. coli for defining protozoa treatment requirements, risk-based critical mean protozoa concentrations in source water were determined with a reverse quantitative microbial risk assessment (QMRA) model. Model assumptions were selected to be consistent with the World Health Organization (WHO) Guidelines for drinking-water quality. The sensitivity of mean E. coli concentration trigger levels to identify these critical concentrations in source water was then evaluated. Results showed no proportionalities between the log of mean E. coli concentrations and the log of mean protozoa concentrations. E. coli/protozoa ratios at DWTPs supplied by small rivers in agricultural and forested areas were typically 1.0 to 2.0-log lower than at DWTPs supplied by large rivers in urban areas. The seasonal variations analysis revealed that these differences were related to low mean E. coli concentrations during winter in small rivers. To achieve the WHO target of 10-6 disability-adjusted life year (DALY) per person per year, a minimum reduction of 4.0-log of Cryptosporidium would be required for 20 DWTPs, and a minimum reduction of 4.0-log of Giardia would be needed for all DWTPs. A mean E. coli trigger level of 50 CFU 100 mL-1 would be a sensitive threshold to identify critical mean concentrations for Cryptosporidium but not for Giardia. Treatment requirements higher than 3.0-log would be needed at DWTPs with mean E. coli concentrations as low as 30 CFU 100 mL-1 for Cryptosporidium and 3 CFU 100 mL-1 for Giardia. Therefore, an E. coli trigger level would have limited value for defining health-based treatment requirements for protozoa at DWTPs supplied by small rivers in rural areas.


Asunto(s)
Criptosporidiosis , Cryptosporidium , Agua Potable , Escherichia coli , Humanos , Medición de Riesgo , Ríos , Microbiología del Agua
20.
Water Res ; 170: 115369, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-31830653

RESUMEN

In several jurisdictions, the arithmetic mean of Escherichia coli concentrations in raw water serves as the metric to set minimal treatment requirements by drinking water treatment plants (DWTPs). An accurate and precise estimation of this mean is therefore critical to define adequate requirements. Distributions of E. coli concentrations in surface water can be heavily skewed and require statistical methods capable of characterizing uncertainty. We present four simple parametric models with different upper tail behaviors (gamma, log-normal, Lomax, mixture of two log-normal distributions) to explicitly account for the influence of peak events on the mean concentration. The performance of these models was tested using large E. coli data sets (200-1800 samples) from raw water regulatory monitoring at six DWTPs located in urban and agricultural catchments. Critical seasons of contamination and hydrometeorological factors leading to peak events were identified. Event-based samples were collected at an urban DWTP intake during two hydrometeorological events using online ß-d-glucuronidase activity monitoring as a trigger. Results from event-based sampling were used to verify whether selected parametric distributions predicted targeted peak events. We found that the upper tail of the log-normal and the Lomax distributions better predicted large concentrations than the upper tail of the gamma distribution. Weekly sampling for two years in urban catchments and for four years in agricultural catchments generated reasonable estimates of the average raw water E. coli concentrations. The proposed methodology can be easily used to inform the development of sampling strategies and statistical indices to set site-specific treatment requirements.


Asunto(s)
Agua Potable , Ríos , Agricultura , Monitoreo del Ambiente , Escherichia coli , Microbiología del Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA