Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
World Neurosurg ; 179: 109-117, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37619840

RESUMEN

BACKGROUND: Rotational angiography, often referred to as a "spin", is typically presented in 2D. Since rotational angiograms are composed of images acquired from multiple angles, we took advantage of this property to develop a method for converting any rotational angiogram into a 3 dimensional (3D) video. METHODS: Our aim was to develop a low cost and easily distributable solution without requiring additional hardware or altering acquisition techniques. Six previously acquired rotational angiograms from our institution were imported using custom-written code and exported as anaglyph (red-cyan) videos. RESULTS: The resulting 3D videos convey anatomical depth that is not apparent from viewing the 2D images alone. Processing time was 1.3 ± 0.6 s (mean ± SD) per angiogram. The only associated cost was $10 for red-cyan 3D glasses. Using our software, any rotational angiogram with at least 0.3 frames per degree of rotation can be converted into 3D. CONCLUSIONS: Our solution is an inexpensive and rapid method for generating stereoscopic videos from existing angiograms. It does not require any additional hardware and is readily deployable in low-resource settings. Because the videos are in anaglyph format, they are viewable on any 2 dimensional (2D) display in the interventional suite or operating room, on a mobile device, or at home.


Asunto(s)
Angiografía , Programas Informáticos , Humanos , Imagenología Tridimensional/métodos
2.
Neurointervention ; 18(1): 67-71, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36717084

RESUMEN

We describe a minimally invasive endovascular approach to treat an arteriovenous fistula of the scalp. We performed a direct puncture of the lesion through the patient's scalp for liquid embolic agent injection along with external compression of the superficial temporal artery to perform a "manual pressure-cooker technique." The combination of these minimally invasive techniques resulted in an excellent clinical and radiographic outcome.

3.
Oper Neurosurg (Hagerstown) ; 23(4): 326-333, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36103334

RESUMEN

BACKGROUND: The scanning fiber endoscope (SFE) is a novel medical imaging device that has been used in various vascular beds as a form of angioscopy, as well as in tracts and duct systems for endoluminal imaging. Owing to its miniaturized form, high resolution, and flexibility, it has demonstrated success in imaging across a wide range of diagnostic applications. OBJECTIVE: To demonstrate, by performing a third ventriculostomy and visualizing the cranial nerves and brainstem anatomy, that, without modification, the SFE can be used through a transcranial approach in a therapeutic intraventricular neurosurgical application. METHODS: A 3.7 French SFE system was used without modification on a live porcine model to perform a third ventriculostomy and acquire high-resolution images of the animal's ventricular system, cranial nerves, and brainstem. A side-by-side comparison was made with one of the current standard-of-care rigid endoscopes as a context for size and image quality. RESULTS: High-resolution video-rate imaging was used to assist the successful, uncomplicated performance of a third ventriculostomy. High-resolution endoscopic images of the brainstem and cranial nerves were acquired. CONCLUSION: Although the SFE has been shown to be a superior device for imaging, here we demonstrate its first use as a potential therapeutic device in intracranial neurosurgery.


Asunto(s)
Neurocirugia , Animales , Endoscopios , Endoscopía , Procedimientos Neuroquirúrgicos/métodos , Porcinos , Ventriculostomía
4.
Interv Neuroradiol ; 24(6): 624-630, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29871561

RESUMEN

OBJECTIVE: Numerous studies have suggested a relationship between delayed occlusion of intracranial aneurysms treated with the Pipeline Embolization Device (PED) and the presence of an incorporated branch. However, in some cases, flow diversion may still be the preferred treatment option. This study sought to determine whether geometric factors pertaining to relative size and angulation of branch vessel(s) can be measured in a reliable fashion and whether they are related to occlusion rates. METHODS: Eighty aneurysms treated at a single neurovascular center from November 2008 to June 2014 were identified. Two blinded raters prospectively reviewed the imaging performed at the time of the procedure and measured the following geometric variables: inflow jet/incorporated branch direction angle and branch artery/ parent artery ratio. Delayed occlusion was defined as the absence of complete aneurysmal occlusion at one year. Analysis was performed using logistic regression and intra-class correlation co-efficient (ICC). RESULTS: Twenty-four (30%) aneurysms with 28 incorporated branches were identified. A trend toward higher inflow jet/incorporated branch direction angle was found in the group of aneurysms demonstrating delayed occlusion when compared to the group with complete occlusion. ICC revealed high correlation. Overall lower one-year occlusion rates of 53% versus 73% for aneurysms with and without incorporated branches, respectively, were also noted. CONCLUSIONS: The presence of an incorporated branch conferred a 20% absolute risk increase for delayed aneurysmal occlusion. Incorporated branches with a larger angle between the inflow jet and the incorporated branch direction exhibited a trend toward lower occlusion rates. This might be further investigated using a multicenter approach in conjunction with other potentially relevant clinical and angiographic variables.


Asunto(s)
Prótesis Vascular , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Procedimientos Neuroquirúrgicos/métodos , Adulto , Anciano , Angiografía de Substracción Digital , Anticoagulantes/uso terapéutico , Embolización Terapéutica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Estudios Retrospectivos , Medición de Riesgo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
J Neurointerv Surg ; 2016 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-26962043

RESUMEN

The pipeline embolization device (PED) is a well recognized treatment for intracranial aneurysms. However, uncertainty remains regarding its effects on flow alteration, which is particularly highlighted by persistently perfused aneurysmal remnants and non-regressing, non-perfused aneurysmal masses. Here we present a 68-year-old woman with an incidental giant fusiform right paraophthalmic aneurysm electively treated with a PED. After lowering her antiplatelet therapy to promote aneurysm thrombosis, she was found to have a progressively enlarging perfused aneurysmal remnant. Angiography revealed PED occlusion, but curiously the development of a peri-construct collateral channel which feeds the aneurysmal remnant, and gives rise to distal branches and contributes to middle cerebral artery flow. The large 'thrombosed' aneurysmal mass showed tiny internal vessels on cone beam CT angiography as well as florid enhancement on MRI, further confirming that apparently thrombosed remnants are biologically active and may be remodeled depending on flow demand.

6.
BMJ Case Rep ; 20162016 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-26944374

RESUMEN

The pipeline embolization device (PED) is a well recognized treatment for intracranial aneurysms. However, uncertainty remains regarding its effects on flow alteration, which is particularly highlighted by persistently perfused aneurysmal remnants and non-regressing, non-perfused aneurysmal masses. Here we present a 68-year-old woman with an incidental giant fusiform right paraophthalmic aneurysm electively treated with a PED. After lowering her antiplatelet therapy to promote aneurysm thrombosis, she was found to have a progressively enlarging perfused aneurysmal remnant. Angiography revealed PED occlusion, but curiously the development of a peri-construct collateral channel which feeds the aneurysmal remnant, and gives rise to distal branches and contributes to middle cerebral artery flow. The large 'thrombosed' aneurysmal mass showed tiny internal vessels on cone beam CT angiography as well as florid enhancement on MRI, further confirming that apparently thrombosed remnants are biologically active and may be remodeled depending on flow demand.


Asunto(s)
Procedimientos Quirúrgicos Electivos/efectos adversos , Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Anciano , Angiografía Cerebral/métodos , Embolización Terapéutica/métodos , Femenino , Humanos , Aneurisma Intracraneal/patología , Imagen por Resonancia Magnética/métodos , Arteria Cerebral Media/patología , Trombosis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA