Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Infect Dis ; 212 Suppl 2: S98-S100, 2015 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-25821225

RESUMEN

Personal protective equipment (PPE) is an important part of worker protection during filovirus outbreaks. The need to protect against a highly virulent fluid-borne pathogen in the tropical environment imposes a heat stress on the wearer that is itself a safety risk. No evidence supports the choice of PPE employed in recent outbreaks, and standard testing procedures employed by the protective garment industry do not well simulate filovirus exposure. Further research is needed to determine the appropriate PPE for filoviruses and the heat stress that it imposes.


Asunto(s)
Infecciones por Filoviridae/epidemiología , Infecciones por Filoviridae/prevención & control , Filoviridae/patogenicidad , Equipo de Protección Personal/virología , Brotes de Enfermedades , Epidemias , Infecciones por Filoviridae/virología , Humanos
2.
J Hazard Mater ; 411: 125045, 2021 06 05.
Artículo en Inglés | MEDLINE | ID: mdl-33453663

RESUMEN

Previously, we have demonstrated the capability of activated charcoal cloth (ACC) to assess dermal exposure to VOCs. Here we investigated whether ACC patches can be used as an under-glove indicator to evaluate the ingress of toluene through disposable gloves in a controlled environment, and compared these results to the amount of toluene ingress determined from the standardized test methods for determining chemical permeation through PPE. In a test chamber, with plugs for air sampling, five to six ACC patches were placed on a mannequin hand underneath disposable gloves (latex, nitrile, neoprene, polymer laminate). Three work-exposure scenarios were simulated to assess toluene ingress through the different gloves: vapor exposure; spray exposure, and immersion. The standard permeation test, using a diffusion cell, was carried with glove material of the palm, with continuous contact conditions. In all of ACC test, the order of toluene ingress was latex > neoprene > nitrile > Barrier, but for the standardized testing, the order of the neoprene and nitrile was reversed, and nitrile had higher levels of toluene ingress. These results show the need to think beyond standard testing techniques for occupational exposure to hazardous substances, and the added value of "application style" testing.


Asunto(s)
Guantes Protectores , Exposición Profesional , Látex , Ensayo de Materiales , Nitrilos , Exposición Profesional/análisis , Permeabilidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA