Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Idioma
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(11): 3129-34, 2012 Nov.
Artículo en Zh | MEDLINE | ID: mdl-23387193

RESUMEN

Monoclinic fusiform zirconium dioxide (ZrO2) nanoparticles were synthesized by hydrothermal method, a method was established based on monoclinic fusiform nanometer-sized ZrO2 enrichment separation, and trace barium in water was determined by inductively coupled plasma mass spectrometry (ICP-MS). The detection limit for Ba(II) was 0.007 ng x mL(-1), and the relative standard deviation was 0.13% (n = 11). The optimal enrichment separation conditions of nanometer-sized ZrO2 for Ba(II) were studied in detail, it was found that the percentage of adsorbed Ba(II) was more than 99% under pH 10.0 and 2 mL 0.5 mol x L(-1) HCl was sufficient for elution of Ba(II) by more than 98%. The static adsorption capacity of ZrO2 to Ba(II) was 196.6 microg x g(-1) and enrichment factor was 250. Properties of nanometer-sized ZrO2 were discussed through regeneration experiment and effects of co-existing ions and contrast experiment to ordinary ZrO2, adsorption properties of nanometer-sized ZrO2 were applied to real samples in the analysis of Ba(II) and the determination was carried out by ICP-MS with satisfactory results.


Asunto(s)
Bario/análisis , Espectrometría de Masas , Espectrofotometría Atómica , Contaminantes Químicos del Agua/análisis , Circonio/química , Monitoreo del Ambiente , Espectrometría de Masas/métodos , Nanopartículas/química , Espectrofotometría Atómica/métodos
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(8): 2274-6, 2010 Aug.
Artículo en Zh | MEDLINE | ID: mdl-20939355

RESUMEN

As a pre-digestion method of breast milk microwave-digestion was adopted in this method, and the contents of calcium and phosphorus were determined by ICP-MS at the same time. By optimizing conditions of digestion and ICP-MS, appropriate internal elements and the isotope mass number and EPA200.8 interference calibration equation were chosen. The accuracy and reliability of method were verified through the recovery and milk powder analysis of national standard substances (GBW10017). Determination results are in the permissible range. The relative deviation (RSD) is less than 2.40%, while the recovery is between 102.8% and 104.0%. ICP-MS method has wide dynamic range, and doesn't need to dilute samples. It is suitable for lots of samples and multi-element analyzed at the same time, and making up default of different method and different element determined respectively in national standard. It is a determination method for calcium and phosphorus supply of breast milk.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA