Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2345-2352, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38183467

RESUMEN

PURPOSE: The purpose of this study is to assess the diagnostic accuracy of ChatGPT in the field of ophthalmology. METHODS: This is a retrospective cohort study conducted in one academic tertiary medical center. We reviewed data of patients admitted to the ophthalmology department from 06/2022 to 01/2023. We then created two clinical cases for each patient. The first case is according to the medical history alone (Hx). The second case includes an addition of the clinical examination (Hx and Ex). For each case, we asked for the three most likely diagnoses from ChatGPT, residents, and attendings. Then, we compared the accuracy rates (at least one correct diagnosis) of all groups. Additionally, we evaluated the total duration for completing the assignment between the groups. RESULTS: ChatGPT, residents, and attendings evaluated 126 cases from 63 patients (history only or history and exam findings for each patient). ChatGPT achieved a significantly lower accurate diagnosis rate (54%) in the Hx, as compared to the residents (75%; p < 0.01) and attendings (71%; p < 0.01). After adding the clinical examination findings, the diagnosis rate of ChatGPT was 68%, whereas for the residents and the attendings, it increased to 94% (p < 0.01) and 86% (p < 0.01), respectively. ChatGPT was 4 to 5 times faster than the attendings and residents. CONCLUSIONS AND RELEVANCE: ChatGPT showed low diagnostic rates in ophthalmology cases compared to residents and attendings based on patient history alone or with additional clinical examination findings. However, ChatGPT completed the task faster than the physicians.


Asunto(s)
Oftalmopatías , Oftalmología , Humanos , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Oftalmopatías/diagnóstico , Competencia Clínica , Reproducibilidad de los Resultados , Anciano , Internado y Residencia , Técnicas de Diagnóstico Oftalmológico , Adulto
2.
Retina ; 44(1): 78-82, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37607406

RESUMEN

PURPOSE: To evaluate the risk of a retinal redetachment in women after vaginal delivery versus cesarean delivery. METHODS: Retrospective cohort analysis of patients diagnosed with retinal detachment (RD) who had later delivered in one tertiary medical center. Recurrence rates of RD were obtained from medical charts. RESULTS: A total of 967 women with RDs were evaluated, and 66 patients met the inclusion criteria. The mean age at the time of RD was 22.64 ± 5.81 SD years and 21.75 ± 5.47 SD years in the vaginal delivery group and the cesarean section group, respectively. None of the patients had a history of eye surgery or traumatic eye injury before the event of RD. In all patients, the detached retina was surgically reattached. Retinal detachment was not recorded in the fellow eye during follow-up. We report four cases of redetachment after birth in four women. In our study, there was a 5% rate (n = 2) of RD after a vaginal delivery as compared with a 7.5% (n = 2) redetachment rate for patients after a cesarean delivery ( P = 0.654). CONCLUSION: The risk of a redetachment of the retina in women is not increased after a vaginal delivery as compared with a cesarean delivery. Therefore, in our opinion, there is no ophthalmic benefit in a cesarean section for a woman with prior RD.


Asunto(s)
Cesárea , Desprendimiento de Retina , Humanos , Femenino , Embarazo , Cesárea/efectos adversos , Estudios Retrospectivos , Desprendimiento de Retina/diagnóstico , Desprendimiento de Retina/epidemiología , Desprendimiento de Retina/etiología , Parto Obstétrico/efectos adversos , Estudios de Cohortes
3.
Harefuah ; 163(5): 298-304, 2024 May.
Artículo en Hebreo | MEDLINE | ID: mdl-38734943

RESUMEN

INTRODUCTION: Glaucoma is a progressive optic neuropathy and is the leading cause of preventable irreversible blindness worldwide. Glaucoma causes progressive visual field loss and can have significant implications on the patient's quality of life. Lowering intraocular pressure (IOP) is the only treatment proven to prevent vision loss from glaucoma. It is achieved using medication, laser treatment and surgery. The treatment paradigm of glaucoma has been one whereby surgical intervention has been left for advanced cases due to a variety of reasons, mainly concerning safety and long term success. The past two decades have seen a paradigm shift towards earlier IOP lowering interventions using a wide array of different technologies in the laser and surgical spaces. This review aims to understand the background to this paradigm shift, its necessity, and its potential impact on the vision and life of glaucoma patients.


Asunto(s)
Glaucoma , Presión Intraocular , Terapia por Láser , Calidad de Vida , Humanos , Glaucoma/terapia , Glaucoma/cirugía , Presión Intraocular/fisiología , Terapia por Láser/métodos , Ceguera/etiología , Ceguera/prevención & control , Campos Visuales/fisiología , Progresión de la Enfermedad , Enfermedades del Nervio Óptico/etiología , Enfermedades del Nervio Óptico/terapia
4.
J Neuroophthalmol ; 43(1): 29-33, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36790061

RESUMEN

BACKGROUND: To describe recent cases of optic neuritis in patients who received a vaccine for COVID-19. METHODS: Retrospective case series of patients diagnosed with optic neuritis after a recent COVID-19 vaccination with BNT162b2 (Pfizer-BioNTech), in one university-affiliated tertiary hospital, from January 2021 to June 2021. Data were obtained from medical charts. RESULTS: We describe 7 patients who developed optic neuritis after immunization with the BNT162b2 vaccine. CONCLUSIONS: A causal relationship cannot be deduced, and the importance of COVID-19 vaccination is not challenged. However, the authors encourage a prospective monitoring and reporting system for all patients receiving COVID-19 vaccines, to further assess the spectrum of adverse events in large databases.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Neuritis Óptica , Humanos , Vacuna BNT162 , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Neuritis Óptica/diagnóstico , Neuritis Óptica/etiología , Estudios Prospectivos , Estudios Retrospectivos , SARS-CoV-2 , Vacunación/efectos adversos
5.
Aesthet Surg J ; 41(6): NP464-NP471, 2021 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-32427315

RESUMEN

BACKGROUND: Late-onset upper eyelid edema is an uncommonly recognized complication of hyaluronic acid (HA)-based filler injection to the supraorbital area. OBJECTIVES: The authors sought to report their experience in diagnosing and managing late-onset upper eyelid edema. METHODS: This was a noncomparative, retrospective study of a series of 17 consecutive patients who presented with upper eyelid edema 6 to 24 months after uneventful HA filler injection in the supraorbital area. RESULTS: The study group included 17 female patients. The average time of presentation was 13.9 months. Thirteen patients (76.4%) were satisfied after hyaluronidase and requested no further treatment (observation only); 4 patients (23.5%) elected to receive HA filler re-treatment, with satisfactory results. All patients were followed-up for at least 6 months after the re-treatment. CONCLUSIONS: The incidence of late-onset upper eyelid edema is likely to increase as the number of patients undergoing HA filler injection to the supraorbital area increases. Our study emphasizes the importance of recognizing this condition and suggests a suitable noninvasive treatment with satisfying results for both the patient and the physician.


Asunto(s)
Técnicas Cosméticas , Rellenos Dérmicos , Técnicas Cosméticas/efectos adversos , Rellenos Dérmicos/efectos adversos , Edema/inducido químicamente , Edema/diagnóstico , Edema/epidemiología , Párpados , Femenino , Humanos , Ácido Hialurónico/efectos adversos , Estudios Retrospectivos
6.
Int Ophthalmol ; 41(2): 433-440, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32929665

RESUMEN

PURPOSE: Coronavirus disease 2019 (COVID-19) caused a global pandemic with millions infected worldwide. Little is known on the ocular involvement associated with the disease. The aim of this study was to assess the clinical and molecular ocular involvement among patients with confirmed COVID-19 admitted to a tertiary care facility. METHODS: Consecutive patients admitted to the COVID-19 Ward of the Shamir Medical Center in Israel during March and April, 2020 were included. The control group included patients negative for COVID-19 admitted during a similar period to a different ward. Patients were examined by trained Ophthalmologists. SARS-CoV-2 conjunctival swab samples were obtained. RESULTS: Included were 48 patients, 16 with confirmed COVID-19 and 32 controls. Median patient age was 68.5 (interquartile range: 31.5, mean: 63 ± 21) years and 48% were male. Active conjunctival injection was present in three patients (19%) with COVID-19, compared to none in the controls (p = 0.034). Patients with COVID-19 were more likely to complain of foreign body sensation (31.3% vs 3.1%, p = 0.005) and redness of the eye (25% vs 0%, p = 0.003). Conjunctival injection was associated with loss of smell and taste (75% vs 7.7%, p = 0.018). Viral conjunctival swab tests all showed negative results for all three viral genes tested (E, N, and RdRp). CONCLUSIONS: Among patients admitted to a tertiary referral center with confirmed COVID-19, active conjunctival injection was noted in one out of five cases, and was associated with loss of smell and taste. Conjunctival swabs for viral RNA were negative in patients with and without ocular involvement.


Asunto(s)
COVID-19/epidemiología , Infecciones Virales del Ojo/epidemiología , Pandemias , ARN Viral/análisis , SARS-CoV-2/genética , Anciano , Infecciones Virales del Ojo/diagnóstico , Infecciones Virales del Ojo/virología , Femenino , Humanos , Incidencia , Israel/epidemiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
7.
Clin Infect Dis ; 70(9): 1891-1897, 2020 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-31613316

RESUMEN

BACKGROUND: Carriers of extended-spectrum ß-lactamase-producing Enterobacteriaceae (ESBL-PE) who receive cephalosporin-based prophylaxis have twice the risk of surgical site infection (SSI) following colorectal surgery as noncarriers. We tested whether ESBL-PE screening and personalized prophylaxis with ertapenem reduces SSI risk among carriers. METHODS: We conducted a prospective nonrandomized, nonblinded, interventional study in 3 hospitals in Israel, Switzerland, and Serbia. Patients were screened for ESBL-PE carriage before elective colorectal surgery. During the baseline phase, departmental guidelines advised prophylaxis with a cephalosporin plus metronidazole. In the intervention phase, guidelines were changed for ESBL-PE carriers to receive ertapenem. The primary outcome was any type of SSI within 30 days. We calculated adjusted risk differences (ARDs) following logistic regression. RESULTS: The intention-to-treat analysis compared 209 ESBL-PE carriers in the baseline phase to 269 in the intervention phase. SSI rates were 21.5% and 17.5%, respectively (ARD, -4.7% [95% confidence interval {CI}, -11.8% to 2.4%]). Unplanned crossover was high (15%), so to assess efficacy we performed an as-treated analysis comparing 247 patients who received cephalosporin-based prophylaxis with 221 who received ertapenem. SSI rates were 22.7% and 15.8%, respectively (ARD, -7.7% [95% CI, -14.6% to -.8%]), and rates of SSI caused by ESBL-PE were 6.5% and 0.9%, respectively (ARD, -5.6% [95% CI, -8.9% to -2.3%]). There was no significant difference in the rate of deep SSI. The number needed to treat to prevent 1 SSI in ESBL-PE carriers was 13. CONCLUSIONS: Screening for ESBL-PE carriage before colorectal surgery and personalizing prophylaxis for carriers is efficacious in reducing SSI.


Asunto(s)
Cirugía Colorrectal , Infecciones por Enterobacteriaceae , Antibacterianos/uso terapéutico , Cirugía Colorrectal/efectos adversos , Enterobacteriaceae , Infecciones por Enterobacteriaceae/epidemiología , Infecciones por Enterobacteriaceae/prevención & control , Ertapenem , Humanos , Israel , Estudios Prospectivos , Suiza , beta-Lactamasas
8.
Clin Exp Ophthalmol ; 48(7): 889-894, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32639048

RESUMEN

IMPORTANCE: Posterior capsular opacification (PCO) is the most common complication after cataract surgery. BACKGROUND: We aimed to assess the relationship between intraocular lens (IOL) diopter and formation of PCO among a consecutive real-world registry. DESIGN: Cohort study. PARTICIPANTS: Included were 14 264 consecutive cases of uncomplicated cataract surgery performed during 2014 to 2018 in Helsinki University Hospital in Finland. METHODS: Nd:YAG capsulotomies were used as an estimate of clinically significant PCO. A single eye of each patient and a single type of IOL were included. MAIN OUTCOME MEASURE: Nd:YAG posterior capsulotomy free survival. RESULTS: Mean age was 73.2 ± 9.9 years and 61.8% were female. Mean follow-up time was 25.4 ± 16.8 months. Overall PCO rates were 1.1% at 1-year, 3.0% at 2-year, 7.1% at 3-year and 10.2% at 4-year. Patients with IOL diopters (D) in the lower quartile (≤20.0 D) had significantly higher rates of PCO (1.3% at 1-year, 4.4% at 2-years, 9.4% at 3-years and 14.2% at 4-years, P < .001). A logistic regression model showed increased risk for PCO formation with lower diopter IOLs; for ≤20.0 D: OR 1.343 (95% CI: 1.132-1.593), for ≤10.0 D: OR 2.409 (95% CI 1.203-4.287), P < .001 for all comparisons. In a multivariant regression accounting for possible confounders, results remained consistent. CONCLUSIONS AND RELEVANCE: Among a cohort of patients undergoing cataract surgery, use of lower diopter IOLs was associated with increased incidence of clinically significant PCO. Research into IOL biomechanics to decrease PCO may be warranted especially in lower diopter IOLs.


Asunto(s)
Opacificación Capsular , Catarata , Láseres de Estado Sólido , Lentes Intraoculares , Facoemulsificación , Anciano , Opacificación Capsular/epidemiología , Opacificación Capsular/etiología , Opacificación Capsular/cirugía , Estudios de Cohortes , Femenino , Humanos , Implantación de Lentes Intraoculares , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis
9.
Int Ophthalmol ; 40(12): 3259-3267, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32720169

RESUMEN

PURPOSE: To report the clinical outcomes of patients who underwent cataract surgery with implantation of Ankoris monofocal toric intraocular lens (IOL) (PhysIOL SA, Liège, Belgium) using the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA). METHODS: We conducted a retrospective case series of patients who underwent routine cataract extraction and implantation of Ankoris toric IOL using the Zeiss Callisto eye between January 2018 and December 2018 by four senior surgeons. Patients' medical records were reviewed, and clinical outcomes including postoperative refraction, visual acuity outcomes, IOL position and deviation from planned axis were collected. RESULTS: Fifty-six eyes of 56 patients were included, 48% were female, and the mean age was 70 ± 8 years. Patients with pseudoexfoliation syndrome, glaucoma or keratoconus were excluded from the study. Pre-operative mean corneal astigmatism was 2.38 ± 0.78 diopters (D), and mean implanted IOL cylindrical power was 3.06 ± 1.07 D. IOL rotation 30 days postoperatively was within 5° in 82% of eyes and between 6° and 10° in 10.8% of eyes. Mean postoperative refractive astigmatism 30 days postoperatively was 0.22 ± 0.36 D; in 84% of eyes the postoperative refractive astigmatism was ≤ 0.50 D. IOL rotation significantly increased between day 1 to day 7 postoperatively (1.91 ± 3.15° to 3.18 ± 3.3°, P = 0.001). However, no significant rotation had occurred between day 7 and day 30 postoperatively (P = 0.093). CONCLUSION: Cataract surgery with implantation of Ankoris monofocal toric IOL using the Zeiss Callisto Eye marking system is predictable and effective in reducing refractive astigmatism.


Asunto(s)
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificación , Anciano , Astigmatismo/cirugía , Computadores , Femenino , Humanos , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Refracción Ocular , Estudios Retrospectivos
10.
Clin Infect Dis ; 68(10): 1699-1704, 2019 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-30204851

RESUMEN

BACKGROUND: Antibiotic prophylaxis that covers enteric pathogens is essential in preventing surgical site infections (SSIs) after colorectal surgery. Current prophylaxis regimens do not cover extended-spectrum beta-lactamase-producing Enterobacteriaceae (ESBL-PE). We aimed to determine whether the risk of SSI following colorectal surgery is higher in ESBL-PE carriers than in noncarriers. METHODS: We conducted a prospective cohort study of patients who underwent elective colorectal surgery in 3 hospitals in Israel, Switzerland, and Serbia between 2012 and 2017. We included patients who were aged ≥18 years, were screened for ESBL-PE carriage before surgery, received routine prophylaxis with a cephalosporin plus metronidazole, and did not have an infection at the time of surgery. The exposed group was composed of ESBL-PE-positive patients. The unexposed group was a random sample of ESBL-PE-negative patients. We collected data on patient and surgery characteristics and SSI outcomes. We fit logistic mixed effects models with study site as a random effect. RESULTS: A total of 3600 patients were screened for ESBL-PE; 13.8% were carriers SSIs occurred in 55/220 carriers (24.8%) and 49/440 noncarriers (11.1%, P < .001). In multivariable analysis, ESBL-PE carriage more than doubled the risk of SSI (odds ratio [OR], 2.36; 95% confidence interval [CI], 1.50-3.71). Carriers had higher risk of deep SSI (OR, 2.25; 95% CI, 1.27-3.99). SSI caused by ESBL-PE occurred in 7.2% of carriers and 1.6% of noncarriers (OR, 4.23; 95% CI, 1.70-10.56). CONCLUSIONS: ESBL-PE carriers who receive cephalosporin-based prophylaxis are at increased risk of SSI following colorectal surgery.


Asunto(s)
Profilaxis Antibiótica , Portador Sano/microbiología , Cirugía Colorrectal/efectos adversos , Infecciones por Enterobacteriaceae/etiología , Infección de la Herida Quirúrgica/microbiología , Adulto , Anciano , Anciano de 80 o más Años , Antibacterianos/administración & dosificación , Antibacterianos/efectos adversos , Portador Sano/prevención & control , Cefalosporinas/administración & dosificación , Cefalosporinas/efectos adversos , Enterobacteriaceae/efectos de los fármacos , Enterobacteriaceae/enzimología , Infecciones por Enterobacteriaceae/prevención & control , Heces/microbiología , Femenino , Humanos , Israel , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Serbia , Infección de la Herida Quirúrgica/prevención & control , Suiza , beta-Lactamasas
11.
Eur J Ophthalmol ; 34(1): 119-125, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37128126

RESUMEN

PURPOSE: To investigate the influence of post-operative eye patching on corneal thickness, endothelial cells' loss and visual acuity in patients diagnosed Fuchs' endothelial corneal dystrophy (FECD). SETTING: Public healthcare centre, Shamir Medical Centre, Israel. METHODS: This randomized controlled trial included patients with FECD undergoing routine cataract surgery in a public medical centre. Patients were randomly assigned to 2 groups: the eye undergoing surgery was covered with a patch for 24 h in the first group (patched group), and a plastic shield was used in the second (non-patched group). Both groups received a unique dose of a local steroid and antibiotic post-operatively. The eyes were examined pre-operatively, and on days 1, 7 and 30 post-surgery . Examination included: best corrected visual acuity (BCVA), comeplete slit lamp examination, intra ocular pressure (IOP), anterior chamber depth (ACD), central corneal thickness (CCT) using the IOL Master 700 (Zeiss, Germany) and endothelial cell density (ECD) using Specular microscopy. Cumulative dissipated energy (CDE) and operation time were recorded for all cases. RESULTS: The study included 46 eyes of 46 patients diagnosed with FECD. Twenty-three eyes in the patched group, and 23 eyes in the non-patched group . Thirty days post-operatively the CCT in the patched group decreased by 60 ± 38 mµ (9%) compared to 92 ± 80 mµ (13.5%) in the non- patched group (p = 0.04). Seven days post-operatively the CCT in the patched group decreased by 31 ± 35 mµ (5%) compared to 58 ± 76 (8%) in the non-patched group, but this difference did not reach statistical significance (p = 0.081). There was no statistically significant difference in endothelial cells loss as well as BCVA at 1, 7 and 30 days post-operatively between the study groups. CONCLUSIONS: Avoiding eye patch post-operatively after cataract surgery in patients with FECD results in better corneal clarity recovery and reduced corneal edema one month post-operatively. Visual acuity and endothelial cell's loss were not influenced by patching.


Asunto(s)
Catarata , Queratoplastia Endotelial de la Lámina Limitante Posterior , Distrofia Endotelial de Fuchs , Humanos , Células Endoteliales , Distrofia Endotelial de Fuchs/cirugía , Distrofia Endotelial de Fuchs/diagnóstico , Córnea , Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Implantación de Lentes Intraoculares , Endotelio Corneal
12.
Can J Ophthalmol ; 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-38219792

RESUMEN

OBJECTIVE: It is accepted that ocular parameters are more correlated with the fellow eye. This poses a challenge in ophthalmic research. There is a relative scarcity of data concerning the extent of correlation. The aim of this study was to analyze and quantify the correlation of different ocular parameters. DESIGN: Historical registry analysis. PARTICIPANTS: All patients examined in a 10-year period (2011-2021) in one academic tertiary medical centre in central Israel. METHODS: Data from optical coherence tomography examinations and biometry of a single examination of both eyes taken at the same time from each patient was included. Pearson's r values were calculated to estimate the extent of correlation. RESULTS: A total of 17,212 patients were included. Mean age was 73 ± 12.7 years, and 54.5% were female. All examined parameters were highly statistically significantly correlated between eyes (all with p < 0.1 × 10-36), whereas the strength of correlation differed. Very weak correlation was seen in central macular thickness (r = 0.189), and a weak correlation was seen in anterior-chamber depth (r = 0.379) and retinal nerve fibre layer thickness (r = 0.479). A strong correlation was seen in central corneal thickness (r = 0.754), and a very strong correlation was seen in axial length (r = 0.900). CONCLUSIONS: In a retrospective analysis of optical coherence tomography and biometry measurements of >10,000 patients, all examined parameters were highly statistically significantly correlated. Correlation magnitude varied, with structural characteristics more correlated than functional ones. Including both eyes in an outcome analysis likely will introduce bias. We recommend adjusting for inter-eye correlation in all studies assessing ocular outcome measures.

13.
Am J Ophthalmol ; 266: 1-9, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38677637

RESUMEN

PURPOSE: To measure and compare the inter-examiner reproducibility of manifest refraction in patients with keratoconus. DESIGN: Prospective, inter-examiner reliability analysis comparing cases and controls. METHODS: Patients with keratoconus (KC) and healthy subjects had undergone manifest refraction by the same 2 skilled optometrists; each was masked to the refraction of the other, on the same day. The KC group comprised patients with KC, who were recruited from the cornea clinic. The control group consisted of healthy individuals who wore spectacles and did not have KC. Participants for the control group were recruited from the clinic's staff, including doctors, technicians, nurses, and medical students. The study took place in 1 tertiary medical center in Israel from April 2021 to May 2022. The results of the manifest refraction and achieved corrected distance visual acuity (CDVA) were compared between groups. RESULTS: A total of 120 eyes of 60 patients were enrolled in the study, 30 in the keratoconus group and 30 in the control group. A difference of 0.67 ± 0.83 diopters (D) and 0.19 ± 0.21 D in the absolute manifest cylinder was observed between the optometrists in the keratoconus (95% LoA, -0.96, 2.30) and control group (95% LoA, -0.22, 0.61), respectively (P < .001). Multivariate analysis revealed a 22-fold higher likelihood of an error exceeding 0.75 D in cylinder measurements (odds ratio = 22.24; 95% CI = 2.39-206.95) and a 10-fold likelihood of a difference of at least 1 row on the Snellen chart for corrected distance visual acuity (odds ratio = 10.32; 95% CI = 2.39-44.44) in the KC group. CONCLUSIONS: When compared to healthy subjects, patients with KC exhibited greater variability in manifest refraction. This discrepancy has the potential to influence the decision-making process when managing patients with KC.

14.
Eye (Lond) ; 37(6): 1219-1224, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35590103

RESUMEN

PURPOSE: Standard corneal collagen cross-linking (S-CXL) is an effective treatment to arrest Keratoconus (KC) progression in children. Less is known on the long-term efficacy of accelerated CXL (A-CXL) in paediatric populations. METHODS: A historical cohort analysis of paediatric patients (≤18 years) with KC who underwent S-CXL and A-CXL at two tertiary referral centres in Israel between 2010-2017. Preoperative and 3-year postoperative evaluation included changes in visual acuity (best spectacle corrected [BSCVA]) and uncorrected [UCVA]), refractive errors, and keratometric data. RESULTS: Ninety-three eyes of 93 patients were analysed (A-CXL: n = 39; S-CXL: n = 54). Baseline characteristics were similar between groups. Both groups showed a significant improvement in visual acuity compared to baseline (S-CXL: 0.810-0.602 LogMAR UCVA; A-CXL: 0.890-0.306 LogMAR UCVA, p < 0.05 for both). Improvement in BSCVA and UCVA following A-CXL was non-inferior to S-CXL (< ± 0.2 LogMAR). Kmax decreased by a mean of 0.98 ± 5.56 dioptres following S-CXL (p = 0.02) and by 1.48 ± 8.4 dioptres following A-CXL (p = 0.015). Thinnest pachymetry decreased following both treatments (S-CXL: by 26.8 ± 40.7 µm, p = 0.001, A-CXL: by 10.2 ± 13.4 µm, p = 0.028), the difference between groups was within the non-inferiority margin (< ± 10 µm). CONCLUSIONS: Paediatric patients followed for three years after A-CXL showed improved visual function, reduced corneal astigmatism and Kmax, and decreased thinnest corneal thickness. A-CXL was non-inferior to S-CXL at three years in terms of best-corrected and uncorrected visual acuity, thinnest pachymetry, and astigmatism. For Kmax, non-inferiority could not be concluded.


Asunto(s)
Queratocono , Fotoquimioterapia , Humanos , Niño , Queratocono/tratamiento farmacológico , Reticulación Corneal , Fármacos Fotosensibilizantes/uso terapéutico , Estudios de Seguimiento , Rayos Ultravioleta , Riboflavina/uso terapéutico , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico
15.
Eye (Lond) ; 37(9): 1834-1839, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36127423

RESUMEN

OBJECTIVE: To evaluate the accuracy of the ABCD Progression Display and the ABCD grading system in a population of adult patients with keratoconus. METHODS: A retrospective cohort analysis of all adult patients with keratoconus followed at the Shamir Medical Center between 2012 and 2017. A recommendation by the cornea specialist to undergo corneal crosslinking (CXL) was used as a surrogate of ectasia progression. The ABCD grading was not available to the treating physician and was computed post-hoc. Sensitivity and specificity of the ABCD Progression Display was calculated, and multivariate regression was used to estimate the risk to undergo CXL when the ABCD Progression Display indicated progression. The ABCD grading was compared between patients who required CXL to those who did not. A single eye of each patient was included. Sensitivity and specificity of the ABCD Progression Display were 82% and 73%, respectively. A multivariable model adjusted for possible confounders, found that ABCD Progression was associated with a 7-fold risk of undergoing CXL compared to a patient in whom progression was not recorded in the ABCD Progression Display (OR = 7.55; 95% CI = 3.82-14.93, p < 0.001). RESULTS: 293 eyes of 293 patients were analysed. Mean age at presentation was 26.92 ± 6.12 years. In 68 eyes, progression of keratoconus was recorded and CXL was performed (CXL-group). CONCLUSION: The ABCD Progression Display demonstrated adequate sensitivity and specificity and high predictive capabilities of keratoconus progression. It can be effectively utilized as an initial screening test in adults with keratoconus.


Asunto(s)
Queratocono , Fotoquimioterapia , Adulto , Humanos , Adulto Joven , Queratocono/diagnóstico , Queratocono/tratamiento farmacológico , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Retrospectivos , Riboflavina/uso terapéutico , Colágeno/uso terapéutico , Reactivos de Enlaces Cruzados/uso terapéutico , Rayos Ultravioleta , Topografía de la Córnea
16.
Cornea ; 2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38166187

RESUMEN

PURPOSE: The aim of the study was to evaluate the efficacy and safety of quantum molecular resonance in the treatment of dry eye disease. METHODS: This study was a double-blind randomized control trial in 1 academic medical center, for 2 years. Participants received treatment or a placebo with the Rexon-Eye device, once per week for 4 weeks. The primary outcome was the change in dry eye symptoms assessed by the Ocular Surface Disease Index (OSDI). Secondary outcomes were clinical findings associated with the dry eye such as meibomian gland dysfunction (MGD) score, tear break-up time (TBUT), corneal fluorescein staining, Schirmer test, and best-corrected visual acuity (BCVA). RESULTS: Forty patients were recruited, 20 in each arm. The mean age was 63.5 ± 15.1 years and 27 (67.5%) were female. The mean OSDI score significantly improved in the intervention group from 19.15 ± 10.3 to 10.5 ± 7.0 (P < 0.001), whereas the control group showed no significant change (14.4 ± 8.4 to 15.5 ± 8.6, P = 0.830). MGD scores significantly improved in the intervention group (1.57 ± 1.2 to 0.8 ± 0.9, P = 0.006), whereas showing no significant change in the control group (1.60 ± 0.9 to 1.99 ± 1.0, P = 0.244). The corneal staining score also showed significant improvement in the intervention group (P = 0.045) and a nonsignificant decline in the placebo group (P = 0.50). No significant difference was seen in TBUT, visual acuity, and Schirmer scores between groups. No harm resulting from treatment was reported during the duration of the trial. CONCLUSIONS: High-frequency electrotherapy may have a positive effect on symptoms and signs of dry eye. This emerging technology may become part of the arsenal of therapeutic modalities for this condition.

17.
Eye (Lond) ; 36(9): 1772-1776, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-34373609

RESUMEN

OBJECTIVE: To evaluate the incidence of consecutive exotropia following bilateral medial rectus muscle recession surgery (BMR) for esotropia using non-absorbable compared with absorbable sutures in children undergoing strabismus surgery. METHODS: A retrospective cohort study of all children with esotropia who underwent BMR by a single surgeon in a tertiary public hospital. As of February 2018, only non-absorbable sutures were used. The primary outcome was the incidence of consecutive exotropia. RESULTS: A total of 121 children were included in the analysis, 3.66 ± 2.62 years, 53% were male. In 80 children (66%) non-absorbable sutures were used (non-absorbable group) and in 41 children (34%) absorbable sutures were used (absorbable group). Consecutive exotropia (≥ 8 prism dioptres) occurred in ten children (24%) in the absorbable group and in three children (4%) in the non-absorbable group (OR = 8.28, 95% CI = 2.13-32.13; P = 0.002). This difference between groups remained significant after adjustment for potential confounders and follow-up time (HR = 4.98, 95% CI = 1.30-19.05, P = 0.019). Mean follow-up time was 22 and 12 months in the absorbable and non-absorbable groups, respectively (P < 0.001). Two children in the non-absorbable group had pyogenic granuloma that resolved after 3 months of topical steroidal therapy. CONCLUSION: Routine use of non-absorbable sutures in BMR surgery for esotropia may be a preferable alternative to absorbable sutures for the prevention of consecutive exotropia.


Asunto(s)
Esotropía , Exotropía , Niño , Esotropía/cirugía , Exotropía/cirugía , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Músculos Oculomotores/cirugía , Procedimientos Quirúrgicos Oftalmológicos/efectos adversos , Estudios Retrospectivos , Suturas/efectos adversos , Resultado del Tratamiento , Visión Binocular/fisiología
18.
J Refract Surg ; 38(10): 668-673, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36214349

RESUMEN

PURPOSE: To assess the refractive prediction error of four intraocular lens (IOL) calculation formulas in eyes that have undergone scleral fixation using the four-flanged technique. METHODS: This was a retrospective cohort analysis of patients who underwent scleral fixation using the four-flanged technique at the Shamir Medical Center between 2020 and 2021. Refractive prediction errors for four IOL prediction formulas (Barrett Universal II, Holladay 1, SRK/T, and Kane) were obtained by subtracting the predicted spherical equivalent from the postoperative spherical equivalent. Mean arithmetic refractive prediction error and mean absolute error were calculated and compared. RESULTS: Twenty-three eyes of 23 patients were included in the analysis. The Akreos AO60 IOL (Bausch & Lomb, Inc) was implanted in 9 eyes and the BunnyLens HP IOL (Hanita Lenses) in 14 eyes. Mean age was 72.84 ± 13.2 years. All formulas produced myopic mean arithmetic refractive prediction error. Mean arithmetic refractive error and mean absolute error were equal in absolute number. Mean arithmetic refractive prediction errors were -0.72 diopters (D) for Barrett Universal II, -0.61 D for Holladay 1, -0.77 D for SRK/T, and -0.94 D for Kane formulas. The refractive outcome differed significantly from the predicted refraction in all formulas. There were no statistically significant differences in prediction errors between the formulas. CONCLUSIONS: Refractive outcomes of the four-flanged fixation technique produced myopic results compared to the predicted refraction for all formulas tested. This suggests that the effective lens position is more anterior than in-the-bag IOL implantation. [J Refract Surg. 2022;36(10):668-673.].


Asunto(s)
Lentes Intraoculares , Miopía , Facoemulsificación , Errores de Refracción , Anciano , Anciano de 80 o más Años , Biometría/métodos , Humanos , Implantación de Lentes Intraoculares/métodos , Persona de Mediana Edad , Miopía/cirugía , Óptica y Fotónica , Refracción Ocular , Estudios Retrospectivos
19.
Eye (Lond) ; 36(6): 1261-1265, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34140653

RESUMEN

OBJECTIVES: To compare the visual outcome of patients treated for non-arthritic central retinal artery occlusion (CRAO) in a medical centre that uses hyperbaric oxygen therapy (HBOT) as part of the standard of care (SOC) to medical centres that does not. METHODS: The study included data from two tertiary medical centres. The medical records of all patients diagnosed with non-arthritic CRAO without a patent cilioretinal artery between January 2010 and December 2018 in two tertiary medical centres were reviewed. RESULTS: One hundred and twenty-one patients were treated by HBOT and 23 patients received only SOC. In the HBOT group, best-corrected visual acuity (BCVA) improved from 2.89 ± 0.98 logMAR at presentation to 2.15 ± 1.07 logMAR upon the end of HBOT (P < 0.001), while the SOC group had no significant improvement, from 3.04 ± 0.82 logMAR at presentation to 2.80 ± 1.50 logMAR (P = 0.24). With adjustment for age, gender, and the duration of symptoms, final BCVA in the HBOT group was significantly better compared to the control group (P = 0.023). Rates of patients achieving vision of 20/200 or better were similar between groups (17.4% vs. 19.8%, P = 0.523). CONCLUSION: Utilizing HBOT as part of the SOC for CRAO improves the final visual outcome. HBOT is safe and can be implemented, if available, as part of SOC in all tertiary medical centres.


Asunto(s)
Oxigenoterapia Hiperbárica , Oclusión de la Arteria Retiniana , Arterias Ciliares , Humanos , Oxígeno , Oclusión de la Arteria Retiniana/terapia , Estudios Retrospectivos
20.
Can J Ophthalmol ; 57(3): 147-153, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34052223

RESUMEN

OBJECTIVE: To characterize the association between prolonged supine postoperative positioning of patients undergoing Descemet-stripping automated endothelial keratoplasty (DSAEK) and graft dislocation rate. METHODS: In this retrospective cohort study, medical records of patients who underwent uncomplicated DSAEK surgery at Yitzhak Shamir Medical Center between 2010 and 2019 were reviewed. Nursing documentation of patients' adherence to supine positioning during the postoperative hospitalization period was collected. A patient was considered compliant if he or she was documented as cooperative with supine positioning throughout the first 24 hours. RESULTS: A total of 170 eyes of 138 patients were found eligible. Main indications for surgery were pseudophakic bullous keratopathy (50.6%), previous graft failure (25.9%), and Fuch's endothelial dystrophy (FED; 20.6%). Twelve surgeries were combined with cataract extraction. Postoperative graft detachment occurred in 26 eyes (15.3%) after an average period of 1 day (range, 0-20 days). Compliance with supine positioning was documented in 84.1% (n = 143 patients). Noncompliance rates during the first 24 hours in the detached and nondetached groups were 26.9% (n = 7) and 14.4% (n = 20), respectively; after adjustment for possible confounders, the odds ratio (OR) was 1.44 (p = 0.249). Graft dislocation was observed in 13.3% (19 of 143) and 25.9% (7 of 27) of cooperative and noncooperative patients, respectively (p = 0.17). Subanalysis of 120 eyes with either BPK or FED for which it was the first transplantation demonstrated a protective effect of supine positioning (OR 3.42, confidence interval 1.095-10.700; p = 0.034). Findings for both groups remained unchanged in multivariate analysis. CONCLUSIONS: We found a statistically significant protective effect of 24 hours of postoperative supine positioning against graft detachment after DSAEK in eyes with no prior transplantations.


Asunto(s)
Enfermedades de la Córnea , Queratoplastia Endotelial de la Lámina Limitante Posterior , Distrofia Endotelial de Fuchs , Enfermedades de la Córnea/cirugía , Endotelio Corneal , Femenino , Distrofia Endotelial de Fuchs/cirugía , Supervivencia de Injerto , Humanos , Estudios Retrospectivos , Posición Supina , Agudeza Visual
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA