Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Biol Chem ; 299(3): 102902, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36642178

RESUMEN

The programmed cell death protein-1 (PD-1) is highly expressed on the surface of antigen-specific exhausted T cells and, upon interaction with its ligand PD-L1, can result in inhibition of the immune response. Anti-PD-1 treatment has been shown to extend survival and result in durable responses in several cancers, yet only a subset of patients benefit from this therapy. Despite the implication of metabolic alteration following cancer immunotherapy, mechanistic associations between antitumor responses and metabolic changes remain unclear. Here, we used desorption electrospray ionization mass spectrometry imaging to examine the lipid profiles of tumor tissue from three syngeneic murine models with varying treatment sensitivity at the baseline and at three time points post-anti-PD-1 therapy. These imaging experiments revealed specific alterations in the lipid profiles associated with the degree of response to treatment and allowed us to identify a significant increase of long-chain polyunsaturated lipids within responsive tumors following anti-PD-1 therapy. Immunofluorescence imaging of tumor tissues also demonstrated that the altered lipid profile associated with treatment response is localized to dense regions of tumor immune infiltrates. Overall, these results indicate that effective anti-PD-1 therapy modulates lipid metabolism in tumor immune infiltrates, and we thereby propose that further investigation of the related immune-metabolic pathways may be useful for better understanding success and failure of anti-PD-1 therapy.


Asunto(s)
Anticuerpos Monoclonales , Antígeno B7-H1 , Neoplasias , Animales , Humanos , Ratones , Anticuerpos Monoclonales/uso terapéutico , Antígeno B7-H1/antagonistas & inhibidores , Inmunoterapia , Lípidos , Neoplasias/tratamiento farmacológico , Neoplasias/metabolismo , Neoplasias/patología , Linfocitos T/metabolismo , Microambiente Tumoral
2.
Anal Chem ; 96(21): 8234-8242, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38739527

RESUMEN

Mass spectrometry has been increasingly explored in intraoperative studies as a potential technology to help guide surgical decision making. Yet, intraoperative experiments using high-performance mass spectrometry instrumentation present a unique set of operational challenges. For example, standard operating rooms are often not equipped with the electrical requirements to power a commercial mass spectrometer and are not designed to accommodate their permanent installation. These obstacles can impact progress and patient enrollment in intraoperative clinical studies because implementation of MS instrumentation becomes limited to specific operating rooms that have the required electrical connections and space. To expand our intraoperative clinical studies using the MasSpec Pen technology, we explored the feasibility of transporting and acquiring data on Orbitrap mass spectrometers operating on battery power in hospital buildings. We evaluated the effect of instrument movement including acceleration and rotational speeds on signal stability and mass accuracy by acquiring data using direct infusion electrospray ionization. Data were acquired while rolling the systems in/out of operating rooms and while descending/ascending a freight elevator. Despite these movements and operating the instrument on battery power, the relative standard deviation of the total ion current was <5% and the magnitude of the mass error relative to the internal calibrant never exceeded 5.06 ppm. We further evaluated the feasibility of performing intraoperative MasSpec Pen analysis while operating the Orbitrap mass spectrometer on battery power during an ovarian cancer surgery. We observed that the rich and tissue-specific molecular profile commonly detected from ovarian tissues was conserved when running on battery power. Together, these results demonstrate that Orbitrap mass spectrometers can be operated and acquire data on battery power while in motion and in rotation without losses in signal stability or mass accuracy. Furthermore, Orbitrap mass spectrometers can be used in conjunction to the MasSpec Pen while on battery power for intraoperative tissue analysis.


Asunto(s)
Suministros de Energía Eléctrica , Humanos , Espectrometría de Masas/métodos , Femenino , Neoplasias Ováricas/cirugía
3.
Proc Natl Acad Sci U S A ; 118(28)2021 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-34260388

RESUMEN

Intraoperative delineation of tumor margins is critical for effective pancreatic cancer surgery. Yet, intraoperative frozen section analysis of tumor margins is a time-consuming and often challenging procedure that can yield confounding results due to histologic heterogeneity and tissue-processing artifacts. We have previously described the development of the MasSpec Pen technology as a handheld mass spectrometry-based device for nondestructive tissue analysis. Here, we evaluated the usefulness of the MasSpec Pen for intraoperative diagnosis of pancreatic ductal adenocarcinoma based on alterations in the metabolite and lipid profiles in in vivo and ex vivo tissues. We used the MasSpec Pen to analyze 157 banked human tissues, including pancreatic ductal adenocarcinoma, pancreatic, and bile duct tissues. Classification models generated from the molecular data yielded an overall agreement with pathology of 91.5%, sensitivity of 95.5%, and specificity of 89.7% for discriminating normal pancreas from cancer. We built a second classifier to distinguish bile duct from pancreatic cancer, achieving an overall accuracy of 95%, sensitivity of 92%, and specificity of 100%. We then translated the MasSpec Pen to the operative room and predicted on in vivo and ex vivo data acquired during 18 pancreatic surgeries, achieving 93.8% overall agreement with final postoperative pathology reports. Notably, when integrating banked tissue data with intraoperative data, an improved agreement of 100% was achieved. The result obtained demonstrate that the MasSpec Pen provides high predictive performance for tissue diagnosis and compatibility for intraoperative use, suggesting that the technology may be useful to guide surgical decision-making during pancreatic cancer surgeries.


Asunto(s)
Tecnología Biomédica , Márgenes de Escisión , Espectrometría de Masas , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/cirugía , Anciano , Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/patología , Carcinoma Ductal Pancreático/cirugía , Conducto Colédoco/patología , Conducto Colédoco/cirugía , Femenino , Humanos , Cuidados Intraoperatorios , Masculino , Persona de Mediana Edad , Páncreas/patología , Páncreas/cirugía , Neoplasias Pancreáticas/patología , Estadística como Asunto
4.
Anal Chem ; 95(34): 12913-12922, 2023 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-37579019

RESUMEN

Mass spectrometry imaging (MSI) has gained increasing popularity for tissue-based diagnostics due to its ability to identify and visualize molecular characteristics unique to different phenotypes within heterogeneous samples. Data from MSI experiments are often assessed and visualized using various supervised and unsupervised statistical approaches. However, these approaches tend to fall short in identifying and concisely visualizing subtle, phenotype-relevant molecular changes. To address these shortcomings, we developed aggregated molecular phenotype (AMP) scores. AMP scores are generated using an ensemble machine learning approach to first select features differentiating phenotypes, weight the features using logistic regression, and combine the weights and feature abundances. AMP scores are then scaled between 0 and 1, with lower values generally corresponding to class 1 phenotypes (typically control) and higher scores relating to class 2 phenotypes. AMP scores, therefore, allow the evaluation of multiple features simultaneously and showcase the degree to which these features correlate with various phenotypes. Due to the ensembled approach, AMP scores are able to overcome limitations associated with individual models, leading to high diagnostic accuracy and interpretability. Here, AMP score performance was evaluated using metabolomic data collected from desorption electrospray ionization MSI. Initial comparisons of cancerous human tissues to their normal or benign counterparts illustrated that AMP scores distinguished phenotypes with high accuracy, sensitivity, and specificity. Furthermore, when combined with spatial coordinates, AMP scores allow visualization of tissue sections in one map with distinguished phenotypic borders, highlighting their diagnostic utility.


Asunto(s)
Diagnóstico por Imagen , Neoplasias , Humanos , Diagnóstico por Imagen/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Neoplasias/diagnóstico por imagen , Metabolómica , Fenotipo , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Imagen Molecular/métodos
5.
Anal Chem ; 94(42): 14734-14744, 2022 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-36228313

RESUMEN

Solvent-based ambient ionization mass spectrometry (MS) techniques provide a powerful approach for direct chemical analysis and molecular profiling of biological tissues. While molecular profiling of tissues has been widely used for disease diagnosis, little is understood about how the interplay among solvent properties, matrix effects, and ion suppression can influence the detection of biological molecules. Here, we perform a systematic investigation of the extraction processes of lipids using an ambient ionization droplet microsampling platform to investigate how the physicochemical properties of the solvent systems and extraction time influence molecular extraction and detection. Direct molecular profiling and quantitative liquid chromatography-mass spectrometry (LC-MS) of discrete solvent droplets after surface sampling were investigated to provide insights into extraction and ionization mechanisms. The results of this study suggest that intermolecular interactions such as hydrogen bonding play a major role in extraction and detection of lipids using solvent-based ambient ionization techniques. In addition, extraction time was observed to impact the molecular profiles obtained, suggesting optimization of this parameter can be performed to favor detection of specific analytes.


Asunto(s)
Lípidos , Espectrometría de Masa por Ionización de Electrospray , Solventes/química , Cromatografía de Gases y Espectrometría de Masas , Espectrometría de Masas/métodos , Cromatografía Liquida/métodos , Lípidos/análisis
6.
Clin Chem ; 68(11): 1459-1470, 2022 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-36103272

RESUMEN

BACKGROUND: Rapid identification of bacteria is critical to prevent antimicrobial resistance and ensure positive patient outcomes. We have developed the MasSpec Pen, a handheld mass spectrometry-based device that enables rapid analysis of biological samples. Here, we evaluated the MasSpec Pen for identification of bacteria from culture and clinical samples. METHODS: A total of 247 molecular profiles were obtained from 43 well-characterized strains of 8 bacteria species that are clinically relevant to osteoarticular infections, including Staphylococcus aureus, Group A and B Streptococcus, and Kingella kingae, using the MasSpec Pen coupled to a high-resolution mass spectrometer. The molecular profiles were used to generate statistical classifiers based on metabolites that were predictive of Gram stain category, genus, and species. Then, we directly analyzed samples from 4 patients, including surgical specimens and clinical isolates, and used the classifiers to predict the etiologic agent. RESULTS: High accuracies were achieved for all levels of classification with a mean accuracy of 93.3% considering training and validation sets. Several biomolecules were detected at varied abundances between classes, many of which were selected as predictive features in the classifiers including glycerophospholipids and quorum-sensing molecules. The classifiers also enabled correct identification of Gram stain type and genus of the etiologic agent from 3 surgical specimens and all classification levels for clinical specimen isolates. CONCLUSIONS: The MasSpec Pen enables identification of several bacteria at different taxonomic levels in seconds from cultured samples and has potential for culture-independent identification of bacteria directly from clinical samples based on the detection of metabolic species.


Asunto(s)
Bacterias , Staphylococcus aureus , Humanos , Bacterias/genética , Espectrometría de Masas
7.
Mass Spectrom Rev ; 40(5): 692-720, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33094861

RESUMEN

Developments in mass spectrometry technologies have driven a widespread interest and expanded their use in cancer-related research and clinical applications. In this review, we highlight the developments in mass spectrometry methods and instrumentation applied to direct tissue analysis that have been tailored at enhancing performance in clinical research as well as facilitating translation and implementation of mass spectrometry in clinical settings, with a focus on cancer-related studies. Notable studies demonstrating the capabilities of direct mass spectrometry analysis in biomarker discovery, cancer diagnosis and prognosis, tissue analysis during oncologic surgeries, and other clinically relevant problems that have the potential to substantially advance cancer patient care are discussed. Key challenges that need to be addressed before routine clinical implementation including regulatory efforts are also discussed. Overall, the studies highlighted in this review demonstrate the transformative potential of mass spectrometry technologies to advance clinical research and care for cancer patients. © 2020 Wiley Periodicals, Inc. Mass Spec Rev.


Asunto(s)
Neoplasias , Humanos , Espectrometría de Masas
8.
Proc Natl Acad Sci U S A ; 116(43): 21401-21408, 2019 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-31591199

RESUMEN

Thyroid neoplasia is common and requires appropriate clinical workup with imaging and fine-needle aspiration (FNA) biopsy to evaluate for cancer. Yet, up to 20% of thyroid nodule FNA biopsies will be indeterminate in diagnosis based on cytological evaluation. Genomic approaches to characterize the malignant potential of nodules showed initial promise but have provided only modest improvement in diagnosis. Here, we describe a method using metabolic analysis by desorption electrospray ionization mass spectrometry (DESI-MS) imaging for direct analysis and diagnosis of follicular cell-derived neoplasia tissues and FNA biopsies. DESI-MS was used to analyze 178 tissue samples to determine the molecular signatures of normal, benign follicular adenoma (FTA), and malignant follicular carcinoma (FTC) and papillary carcinoma (PTC) thyroid tissues. Statistical classifiers, including benign thyroid versus PTC and benign thyroid versus FTC, were built and validated with 114,125 mass spectra, with accuracy assessed in correlation with clinical pathology. Clinical FNA smears were prospectively collected and analyzed using DESI-MS imaging, and the performance of the statistical classifiers was tested with 69 prospectively collected clinical FNA smears. High performance was achieved for both models when predicting on the FNA test set, which included 24 nodules with indeterminate preoperative cytology, with accuracies of 93% and 89%. Our results strongly suggest that DESI-MS imaging is a valuable technology for identification of malignant potential of thyroid nodules.


Asunto(s)
Espectrometría de Masa por Ionización de Electrospray/métodos , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/metabolismo , Biopsia con Aguja Fina , Femenino , Humanos , Masculino , Estudios Prospectivos , Neoplasias de la Tiroides/metabolismo , Nódulo Tiroideo/química , Nódulo Tiroideo/diagnóstico por imagen
9.
J Am Chem Soc ; 143(36): 14622-14634, 2021 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-34486374

RESUMEN

Structural characterization of glycerophospholipids beyond the fatty acid level has become a major endeavor in lipidomics, presenting an opportunity to advance the understanding of the intricate relationship between lipid metabolism and disease state. Distinguishing subtle lipid structural features, however, remains a major challenge for high-throughput workflows that implement traditional tandem mass spectrometry (MS/MS) techniques, stunting the molecular depth of quantitative strategies. Here, reversed phase liquid chromatography is coupled to parallel reaction mass spectrometry utilizing the double bond localization capabilities of ultraviolet photodissociation (UVPD) mass spectrometry to produce double bond isomer specific responses that are leveraged for relative quantitation. The strategy provides lipidomic characterization at the double bond level for phosphatidylcholine phospholipids from biological extracts. In addition to quantifying monounsaturated lipids, quantitation of phospholipids incorporating isomeric polyunsaturated fatty acids is also achieved. Using this technique, phosphatidylcholine isomer ratios are compared across human normal and tumor breast tissue to reveal significant structural alterations related to disease state.


Asunto(s)
Fosfatidilcolinas/análisis , Animales , Mama/química , Neoplasias de la Mama/química , Bovinos , Cromatografía de Fase Inversa , Huevos , Ácidos Grasos Insaturados/química , Humanos , Isomerismo , Lipidómica/métodos , Hígado/química , Espectrometría de Masas/métodos , Fosfatidilcolinas/química , Rayos Ultravioleta
10.
Anal Chem ; 93(21): 7549-7556, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34008955

RESUMEN

Analytical methods that allow rapid, sensitive, and specific chemical measurements are central to forensic analysis and essential to accelerating compound screening and confirmation. We have previously reported the development of the MasSpec Pen technology as an easy-to-use and disposable hand-held device integrated to a mass spectrometer for direct analysis and molecular profiling of biological samples. In this Technical Note, we describe a new apparatus that integrates the MasSpec Pen device with a subatmospheric pressure chemical ionization (sub-APCI) source and an ion trap mass spectrometer for detection and semiquantitative analysis of forensic-related compounds. Coupling the MasSpec Pen device to a sub-APCI source allowed semiquantitative analysis of the drugs cocaine and oxycodone, the agrochemicals atrazine and azoxystrobin, and the explosives trinitrotoluene and dinitroglycerin in under 20 s. Using chemical ionization, improved reproducibility and sensitivity for targeted chemical detection and compound identification was achieved while maintaining the user-friendly features of the hand-held MasSpec Pen device. Limits of detection in the high picogram to low nanogram range were obtained for the compounds analyzed, which are within the range of federal screening cutoffs and those reported for other ambient ionization MS techniques. Altogether, the MasSpec Pen sub-APCI system described enabled rapid and semiquantitative chemical analysis for forensic applications and could be further adapted and applied to other areas of chemical testing.


Asunto(s)
Presión Atmosférica , Sustancias Explosivas , Cromatografía de Gases , Espectrometría de Masas , Reproducibilidad de los Resultados
11.
Anal Chem ; 93(37): 12582-12593, 2021 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-34432430

RESUMEN

The outbreak of COVID-19 has created an unprecedent global crisis. While the polymerase chain reaction (PCR) is the gold standard method for detecting active SARS-CoV-2 infection, alternative high-throughput diagnostic tests are of a significant value to meet universal testing demands. Here, we describe a new design of the MasSpec Pen technology integrated to electrospray ionization (ESI) for direct analysis of clinical swabs and investigate its use for COVID-19 screening. The redesigned MasSpec Pen system incorporates a disposable sampling device refined for uniform and efficient analysis of swab tips via liquid extraction directly coupled to an ESI source. Using this system, we analyzed nasopharyngeal swabs from 244 individuals including symptomatic COVID-19 positive, symptomatic negative, and asymptomatic negative individuals, enabling rapid detection of rich lipid profiles. Two statistical classifiers were generated based on the lipid information acquired. Classifier 1 was built to distinguish symptomatic PCR-positive from asymptomatic PCR-negative individuals, yielding a cross-validation accuracy of 83.5%, sensitivity of 76.6%, and specificity of 86.6%, and validation set accuracy of 89.6%, sensitivity of 100%, and specificity of 85.3%. Classifier 2 was built to distinguish symptomatic PCR-positive patients from negative individuals including symptomatic PCR-negative patients with moderate to severe symptoms and asymptomatic individuals, yielding a cross-validation accuracy of 78.4%, specificity of 77.21%, and sensitivity of 81.8%. Collectively, this study suggests that the lipid profiles detected directly from nasopharyngeal swabs using MasSpec Pen-ESI mass spectrometry (MS) allow fast (under a minute) screening of the COVID-19 disease using minimal operating steps and no specialized reagents, thus representing a promising alternative high-throughput method for screening of COVID-19.


Asunto(s)
COVID-19 , Pruebas Diagnósticas de Rutina , Humanos , Nasofaringe , SARS-CoV-2 , Sensibilidad y Especificidad , Manejo de Especímenes
12.
Clin Chem ; 67(9): 1271-1280, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34263289

RESUMEN

BACKGROUND: Intraoperative tissue analysis and identification are critical to guide surgical procedures and improve patient outcomes. Here, we describe the clinical translation and evaluation of the MasSpec Pen technology for molecular analysis of in vivo and freshly excised tissues in the operating room (OR). METHODS: An Orbitrap mass spectrometer equipped with a MasSpec Pen interface was installed in an OR. A "dual-path" MasSpec Pen interface was designed and programmed for the clinical studies with 2 parallel systems that facilitated the operation of the MasSpec Pen. The MasSpec Pen devices were autoclaved before each surgical procedure and were used by surgeons and surgical staff during 100 surgeries over a 12-month period. RESULTS: Detection of mass spectral profiles from 715 in vivo and ex vivo analyses performed on thyroid, parathyroid, lymph node, breast, pancreatic, and bile duct tissues during parathyroidectomies, thyroidectomies, breast, and pancreatic neoplasia surgeries was achieved. The MasSpec Pen enabled gentle extraction and sensitive detection of various molecular species including small metabolites and lipids using a droplet of sterile water without causing apparent tissue damage. Notably, effective molecular analysis was achieved while no limitations to sequential histologic tissue analysis were identified and no device-related complications were reported for any of the patients. CONCLUSIONS: This study shows that the MasSpec Pen system can be successfully incorporated into the OR, allowing direct detection of rich molecular profiles from tissues with a seconds-long turnaround time that could be used to inform surgical and clinical decisions without disrupting tissue analysis workflows.


Asunto(s)
Neoplasias Pancreáticas , Humanos , Espectrometría de Masas , Paratiroidectomía , Glándula Tiroides
13.
Anal Bioanal Chem ; 413(13): 3573-3582, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33829277

RESUMEN

Mammalian folate-dependent one-carbon (1C) metabolism provides the building blocks essential during development via amino acid interconversion, methyl-donor production, regeneration of redox factors, and de novo purine and thymidylate synthesis. Folate supplementation prevents many neural tube defects (NTDs) that occur during the embryonic process of neurulation. The mechanism by which folate functions during neurulation is not well understood, and not all NTDs are preventable by folate supplementation. Mthfd1l is a mitochondrial 1C metabolism enzyme that produces formate, a 1C donor that fuels biosynthesis and the methyl cycle in the cytoplasm. Homozygous deletion of the Mthfd1l gene in mice (Mthfd1lz/z) causes embryonic lethality, developmental delay, and folate-resistant NTDs. These mice also have defects in cranial mesenchyme formation. In this work, mass spectrometry imaging was used to obtain ion maps of the cranial mesenchyme that identified the spatial distribution and relative abundance of metabolites in wild-type and Mthfd1lz/z embryos. The relative abundances of purine and thymidylate derivatives, as well as amino acids, were diminished in the cranial mesenchyme of Mthfd1lz/z embryos. Loss of Mthfd1l activity in this region also led to abnormal levels of methionine and dysregulated energy metabolism. These alterations in metabolism suggest possible approaches to preventing NTDs in humans.


Asunto(s)
Aminohidrolasas/genética , Formiato-Tetrahidrofolato Ligasa/genética , Metilenotetrahidrofolato Deshidrogenasa (NADP)/genética , Complejos Multienzimáticos/genética , Espectrometría de Masa por Ionización de Electrospray/métodos , Animales , Ratones , Ratones Noqueados
14.
Anal Chem ; 92(12): 8386-8395, 2020 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-32421308

RESUMEN

Free fatty acids (FA) are a vital component of cells and are critical to cellular structure and function, so much so that alterations in FA are often associated with cell malfunction and disease. Analysis of FA from biological samples can be achieved by mass spectrometry (MS), but these analyses are often not capable of distinguishing the fine structural alterations within FA isomers and often limited to global profiling of lipids without spatial resolution. Here, we present the use of ultraviolet photodissociation (UVPD) for the characterization of double bond positional isomers of charge inverted dication·FA complexes and the subsequent implementation of this method for online desorption electrospray ionization (DESI) MS imaging of FA isomers from human tissue sections. This method allows relative quantification of FA isomers from heterogeneous biological tissue sections, yielding spatially resolved information about alterations in double bond isomers within these samples. Applying this method to the analysis of the monounsaturated FA 18:1 within breast cancer subtypes uncovered a correlation between double bond positional isomer abundance and the hormone receptor status of the tissue sample, an important factor in the prognosis and treatment of breast cancer patients. This result further validates similar studies that suggest FA synthase activity and FA isomer abundances are significantly altered within breast cancer tissue.


Asunto(s)
Neoplasias de la Mama/química , Ácidos Grasos/análisis , Rayos Ultravioleta , Neoplasias de la Mama/patología , Femenino , Humanos , Espectrometría de Masas , Estructura Molecular , Procesos Fotoquímicos
15.
Anal Chem ; 92(17): 11535-11542, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32786489

RESUMEN

Minimally invasive robotic-assisted surgeries have been increasingly used as a first-line of treatment for patients undergoing oncologic surgeries. In-situ tissue identification is critical to guide tissue resection and assist decision-making. Traditional intraoperative histopathologic analysis of frozen tissue sections can be time-consuming and present logistical challenges which interrupt surgical workflows. We report the development and implementation of a laparoscopic, drop-in version of the MasSpec Pen device integrated into the da Vinci Xi Surgical system for in vivo tissue analysis in a robotic-assisted porcine surgery. We evaluated the performance of the drop-in MasSpec Pen during surgery by introducing the device into the animal upper gastrointestinal system and performing in vivo analyses of the stomach and liver, including charred and bloody tissues after electrocauterization. The molecular profiles obtained included ions tentatively identified as metabolites and lipids typically observed with MasSpec Pen analysis, without causing observable tissue damage. Statistical classifiers built to distinguish porcine liver and stomach tissues using the in vivo data yielded an overall tissue identification accuracy of 98% (n = 53 analyses). The results provide evidence that the drop-in MasSpec Pen developed can be used to acquire mass spectra in vivo during a robotic-assisted surgery and might be used as an in vivo tissue assessment tool to help guide surgical resections and streamline surgical workflows.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo/instrumentación , Diseño de Equipo/instrumentación , Ácidos Grasos/análisis , Ácidos Grasos/metabolismo , Procedimientos Quirúrgicos Robotizados/instrumentación , Cirugía Asistida por Video/instrumentación , Animales , Femenino , Humanos , Técnicas In Vitro , Laparoscopía , Metabolismo de los Lípidos , Espectrometría de Masas , Prótesis e Implantes , Porcinos
16.
Clin Chem ; 66(11): 1424-1433, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33141910

RESUMEN

BACKGROUND: Distinguishing adenocarcinoma and squamous cell carcinoma subtypes of non-small cell lung cancers is critical to patient care. Preoperative minimally-invasive biopsy techniques, such as fine needle aspiration (FNA), are increasingly used for lung cancer diagnosis and subtyping. Yet, histologic distinction of lung cancer subtypes in FNA material can be challenging. Here, we evaluated the usefulness of desorption electrospray ionization mass spectrometry imaging (DESI-MSI) to diagnose and differentiate lung cancer subtypes in tissues and FNA samples. METHODS: DESI-MSI was used to analyze 22 normal, 26 adenocarcinoma, and 25 squamous cell carcinoma lung tissues. Mass spectra obtained from the tissue sections were used to generate and validate statistical classifiers for lung cancer diagnosis and subtyping. Classifiers were then tested on DESI-MSI data collected from 16 clinical FNA samples prospectively collected from 8 patients undergoing interventional radiology guided FNA. RESULTS: Various metabolites and lipid species were detected in the mass spectra obtained from lung tissues. The classifiers generated from tissue sections yielded 100% accuracy, 100% sensitivity, and 100% specificity for lung cancer diagnosis, and 73.5% accuracy for lung cancer subtyping for the training set of tissues, per-patient. On the validation set of tissues, 100% accuracy for lung cancer diagnosis and 94.1% accuracy for lung cancer subtyping were achieved. When tested on the FNA samples, 100% diagnostic accuracy and 87.5% accuracy on subtyping were achieved per-slide. CONCLUSIONS: DESI-MSI can be useful as an ancillary technique to conventional cytopathology for diagnosis and subtyping of non-small cell lung cancers.


Asunto(s)
Adenocarcinoma/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Células Escamosas/diagnóstico , Neoplasias Pulmonares/diagnóstico , Adenocarcinoma/patología , Biopsia con Aguja Fina , Carcinoma de Pulmón de Células no Pequeñas/clasificación , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Células Escamosas/patología , Humanos , Pulmón/patología , Neoplasias Pulmonares/clasificación , Neoplasias Pulmonares/patología , Espectrometría de Masa por Ionización de Electrospray/métodos
17.
Metabolomics ; 16(1): 11, 2020 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-31925564

RESUMEN

INTRODUCTION: Diabetic kidney disease (DKD) is the most prevalent complication in diabetic patients, which contributes to high morbidity and mortality. Urine and plasma metabolomics studies have been demonstrated to provide valuable insights for DKD. However, limited information on spatial distributions of metabolites in kidney tissues have been reported. OBJECTIVES: In this work, we employed an ambient desorption electrospray ionization-mass spectrometry imaging (DESI-MSI) coupled to a novel bioinformatics platform (METASPACE) to characterize the metabolome in a mouse model of DKD. METHODS: DESI-MSI was performed for spatial untargeted metabolomics analysis in kidneys of mouse models (F1 C57BL/6J-Ins2Akita male mice at 17 weeks of age) of type 1 diabetes (T1D, n = 5) and heathy controls (n = 6). RESULTS: Multivariate analyses (i.e., PCA and PLS-DA (a 2000 permutation test: P < 0.001)) showed clearly separated clusters for the two groups of mice on the basis of 878 measured m/z's in kidney cortical tissues. Specifically, mice with T1D had increased relative abundances of pseudouridine, accumulation of free polyunsaturated fatty acids (PUFAs), and decreased relative abundances of cardiolipins in cortical proximal tubules when compared with healthy controls. CONCLUSION: Results from the current study support potential key roles of pseudouridine and cardiolipins for maintaining normal RNA structure and normal mitochondrial function, respectively, in cortical proximal tubules with DKD. DESI-MSI technology coupled with METASPACE could serve as powerful new tools to provide insight on fundamental pathways in DKD.


Asunto(s)
Nefropatías Diabéticas/metabolismo , Túbulos Renales Proximales/metabolismo , Metaboloma , Membranas Mitocondriales/metabolismo , Animales , Cardiolipinas/metabolismo , Biología Computacional , Ácidos Grasos Omega-3/metabolismo , Masculino , Redes y Vías Metabólicas , Ratones , Ratones Endogámicos C57BL , Seudouridina/metabolismo , Espectrometría de Masa por Ionización de Electrospray
18.
Anal Bioanal Chem ; 412(6): 1251-1262, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31953714

RESUMEN

Merging optical images of tissue sections with the spatial distributions of molecules seen by imaging mass spectrometry is a powerful approach to better understand the metabolic roles of the mapped molecules. Here, we use histologically friendly desorption electrospray ionization-mass spectrometry (DESI-MS) to map the lipid distribution in tissue sections of ovaries from cows (N = 8), sows (N = 3), and mice (N = 12). Morphologically friendly DESI-MS imaging allows the same sections to be examined for morphological information. Independent of the species, ovarian follicles, corpora lutea, and stroma could be differentiated by principal component analysis, showing that lipid profiles are well conserved among species. As examples of specific findings, arachidonic acid and the phosphatidylinositol PI(38:4), were both found concentrated in the follicles and corpora lutea, structures that promoted ovulation and implantation, respectively. Adrenic acid was spatially located in the corpora lutea, suggesting the importance of this fatty acid in the ovary luteal phase. In summary, lipid information captured by DESI-MS imaging could be related to ovarian structures and data were all conserved among cows, sows, and mice. Further application of DESI-MS imaging to either physiological or pathophysiological models of reproductive conditions will likely expand knowledge of the roles of specific lipids and pathways in ovarian activity and mammalian fertility. Graphical abstract Desorption electrospray ionization-mass spectrometry (DESI-MS) is performed directly from frozen ovarian tissue sections placed onto glass slides. Because the desorption and ionization process of small molecules is so gentle, the tissue architecture is preserved. The sample can then be stained and tissue morphology information can be overlaid with the chemical information obtained by DESI-MS.


Asunto(s)
Metabolismo de los Lípidos , Ovario/metabolismo , Espectrometría de Masa por Ionización de Electrospray/métodos , Animales , Bovinos , Femenino , Ratones , Porcinos
19.
Proc Natl Acad Sci U S A ; 114(17): 4300-4305, 2017 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-28400509

RESUMEN

KRAS gene mutation causes lung adenocarcinoma. KRAS activation has been associated with altered glucose and glutamine metabolism. Here, we show that KRAS activates lipogenesis, and this activation results in distinct proteomic and lipid signatures. By gene expression analysis, KRAS is shown to be associated with a lipogenesis gene signature and specific induction of fatty acid synthase (FASN). Through desorption electrospray ionization MS imaging (DESI-MSI), specific changes in lipogenesis and specific lipids are identified. By the nanoimmunoassay (NIA), KRAS is found to activate the protein ERK2, whereas ERK1 activation is found in non-KRAS-associated human lung tumors. The inhibition of FASN by cerulenin, a small molecule antibiotic, blocked cellular proliferation of KRAS-associated lung cancer cells. Hence, KRAS is associated with activation of ERK2, induction of FASN, and promotion of lipogenesis. FASN may be a unique target for KRAS-associated lung adenocarcinoma remediation.


Asunto(s)
Adenocarcinoma/enzimología , Ácido Graso Sintasas/metabolismo , Lipogénesis , Neoplasias Pulmonares/enzimología , Proteína Quinasa 1 Activada por Mitógenos/metabolismo , Adenocarcinoma/genética , Adenocarcinoma/metabolismo , Adenocarcinoma del Pulmón , Ácido Graso Sintasas/genética , Humanos , Metabolismo de los Lípidos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/metabolismo , Proteína Quinasa 1 Activada por Mitógenos/genética , Proteína Quinasa 3 Activada por Mitógenos/genética , Proteína Quinasa 3 Activada por Mitógenos/metabolismo , Proteínas Proto-Oncogénicas p21(ras)/genética , Proteínas Proto-Oncogénicas p21(ras)/metabolismo , Transducción de Señal
20.
Int J Mol Sci ; 21(10)2020 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-32443844

RESUMEN

Plasma and tissue from breast cancer patients are valuable for diagnostic/prognostic purposes and are accessible by multiple mass spectrometry (MS) tools. Liquid chromatography-mass spectrometry (LC-MS) and ambient mass spectrometry imaging (MSI) were shown to be robust and reproducible technologies for breast cancer diagnosis. Here, we investigated whether there is a correspondence between lipid cancer features observed by desorption electrospray ionization (DESI)-MSI in tissue and those detected by LC-MS in plasma samples. The study included 28 tissues and 20 plasma samples from 24 women with ductal breast carcinomas of both special and no special type (NST) along with 22 plasma samples from healthy women. The comparison of plasma and tissue lipid signatures revealed that each one of the studied matrices (i.e., blood or tumor) has its own specific molecular signature and the full interposition of their discriminant ions is not possible. This comparison also revealed that the molecular indicators of tissue injury, characteristic of the breast cancer tissue profile obtained by DESI-MSI, do not persist as cancer discriminators in peripheral blood even though some of them could be found in plasma samples.


Asunto(s)
Neoplasias de la Mama/metabolismo , Carcinoma Ductal/metabolismo , Metabolismo de los Lípidos , Lipidómica/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/sangre , Carcinoma Ductal/sangre , Femenino , Humanos , Lípidos/sangre , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA