Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Metabolomics ; 14(9): 116, 2018 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-30830387

RESUMEN

INTRODUCTION: Allograft rejection is still an important complication after kidney transplantation. Currently, monitoring of these patients mostly relies on the measurement of serum creatinine and clinical evaluation. The gold standard for diagnosing allograft rejection, i.e. performing a renal biopsy is invasive and expensive. So far no adequate biomarkers are available for routine use. OBJECTIVES: We aimed to develop a urine metabolite constellation that is characteristic for acute renal allograft rejection. METHODS: NMR-Spectroscopy was applied to a training cohort of transplant recipients with and without acute rejection. RESULTS: We obtained a metabolite constellation of four metabolites that shows promising performance to detect renal allograft rejection in the cohorts used (AUC of 0.72 and 0.74, respectively). CONCLUSION: A metabolite constellation was defined with the potential for further development of an in-vitro diagnostic test that can support physicians in their clinical assessment of a kidney transplant patient.


Asunto(s)
Aloinjertos , Rechazo de Injerto/metabolismo , Rechazo de Injerto/orina , Riñón/metabolismo , Estudios de Cohortes , Humanos , Riñón/diagnóstico por imagen
2.
Acta Radiol ; 57(8): 939-46, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26454065

RESUMEN

BACKGROUND: Preoperative staging of cervical lymph nodes is important to determine the extent of neck dissection in patients with oral squamous cell carcinoma (OSCC). PURPOSE: To evaluate whether a preoperative discrimination of benign and malignant cervical lymph nodes with diffusion-weighted imaging (DWI) (3T) is feasible for clinical application. MATERIAL AND METHODS: Forty-five patients with histological proven OSCC underwent preoperative 3T-MRI. DWI (b = 0, 500, and 1000 s/mm(2)) was added to the standard magnetic resonance imaging (MRI) protocol. Mean apparent diffusion coefficients (ADCmean) were measured for lymph nodes with 3 mm or more in short axis by two independent readers. Finally, these results were matched with histology. RESULTS: Mean ADC was significantly higher for malignant than for benign nodes (1.143 ± 0.188 * 10(-3) mm(2)/s vs. 0.987 ± 0.215 * 10(-3) mm(2)/s). Using an ADC value of 0.994 * 10(-3) mm(2)/s as threshold results in a sensitivity of 80%, specificity of 65%, positive predictive value of 31%, and negative predictive value of 93%. CONCLUSION: Due to a limited sensitivity and specificity DWI alone is not suitable to reliably discriminate benign from malignant cervical lymph nodes in daily clinical routine. Hence, the preoperative determination of the extent of neck dissection on the basis of ADC measurements is not meaningful.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Imagen de Difusión por Resonancia Magnética/métodos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Metástasis Linfática/diagnóstico por imagen , Metástasis Linfática/patología , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/patología , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Sensibilidad y Especificidad
3.
EBioMedicine ; 48: 505-512, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31648995

RESUMEN

BACKGROUND: To validate a novel method for post-transplant surveillance to detect kidney allograft rejection via a characteristic constellation of the urine metabolites alanine, citrate, lactate, and urea investigated by nuclear magnetic resonance (NMR) spectroscopy a first prospective, observational study was performed. METHODS: Within the UMBRELLA study 986 urine specimens were collected from 109 consecutively enrolled renal transplant recipients, and metabolite constellations were analyzed. A metabolite rejection score was calculated and compared to histopathological results of corresponding indication and protocol allograft biopsies (n = 206). FINDINGS: The metabolite constellation was found to be a useful biomarker to non-invasively detect acute allograft rejection (AUC = 0.75; 95% confidence interval (CI) 0.68-0.83; based on 46 cases and 520 control samples). Combined analysis of the metabolite rejection score and the estimated glomerular filtration rate (eGFR) at the time of urine sampling further improved the overall test performance significantly (AUC = 0.84; 95% CI 0.76-0.91; based on 42 cases and 468 controls). Regarding the time course analysis in patients without rejection episodes the test results remained well below a diagnostic threshold associated with high risk of acute rejection. In other cases, a marked increase above this threshold indicated acute allograft rejection already six to ten days before diagnostic renal biopsies were performed. INTERPRETATION: A combination of an NMR-based urine metabolite analysis and eGFR is promising as a non-invasive test for post-transplant surveillance and to support decision making whether renal allografts need histopathological evaluation.


Asunto(s)
Biomarcadores/orina , Rechazo de Injerto/etiología , Rechazo de Injerto/metabolismo , Trasplante de Riñón , Adolescente , Adulto , Anciano , Biopsia , Femenino , Tasa de Filtración Glomerular , Rechazo de Injerto/diagnóstico por imagen , Rechazo de Injerto/orina , Humanos , Pruebas de Función Renal , Trasplante de Riñón/efectos adversos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Curva ROC , Trasplante Homólogo , Adulto Joven
4.
Br J Radiol ; 91(1085): 20170078, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29436841

RESUMEN

OBJECTIVE: The aim of our study was to systematically compare two-point Dixon fat suppression (FS) and spectral FS techniques in contrast enhanced imaging of the head and neck region. METHODS: Three independent readers analysed coronal T1 weighted images recorded after contrast medium injection with Dixon and spectral FS techniques with regard to FS homogeneity, motion artefacts, lesion contrast, image sharpness and overall image quality. RESULTS: 85 patients were prospectively enrolled in the study. Images generated with Dixon-FS technique were of higher overall image quality and had a more homogenous FS over the whole field of view compared with the standard spectral fat-suppressed images (p < 0.001). Concerning motion artefacts, flow artefacts, lesion contrast and image sharpness no statistically significant difference was observed. CONCLUSION: The Dixon-FS technique is superior to the spectral technique due to improved homogeneity of FS and overall image quality while maintaining lesion contrast. Advances in knowledge: T1 with Dixon FS technique offers, compared to spectral FS, significantly improved FS homogeneity and over all image quality in imaging of the head and neck region.


Asunto(s)
Tejido Adiposo , Cabeza/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Cuello/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA