Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Eur J Ophthalmol ; 32(6): 3333-3339, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35102752

RESUMEN

PURPOSE: To evaluate long-term efficacy, safety, predictability and stability (refractive and keratometric) of myopic and myopic astigmatism correction with Small Incision Lenticule Extraction (SMILE). METHODS: Single center retrospective review of eyes undergoing SMILE from 2012-2015. Forty-two eyes (23 patients) with ≥ 5-year follow-up. Variables analyzed were preoperative, 3-month, 1-year and last follow-up uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, spherical equivalent (SE) and mean keratometry. Descriptive statistics were performed and results reported following the Standard for Reporting Astigmatism Outcomes. RESULTS: Mean follow-up of 5.98 ± 0.90 years. Mean preoperative SE was -5.26 ± 1.22D (range -2.50 to -8.12D). Mean preoperative cylinder was -0.66 ± 0.61D (range 0.00 to -2.25D). Efficacy and safety indices were 0.86 and 0.98, respectively. In total, 81% of operated eyes achieved an UDVA of ≥ 0.09 logMar (20/25 Snellen). At the last follow-up, ≥1 line of CDVA was gained in 14% of eyes. Five percent lost 1 line of CDVA, and no eye loss ≥2 lines of CDVA. Sixty-nine percent of eyes were within ± 0.50D and 86% within ± 1.00D of the attempted SE correction. Ninety-one percent of eyes had ≤0.50D of postoperative astigmatism and 71% were within ± 15° from the intended correction axis. At the final follow-up, a statistically significant myopic regression of 0.19 ± 0.50D was observed (p = 0.01). CONCLUSIONS: Long-term results demonstrate that SMILE is effective, predictable and safe. SMILE has good stability, low regression compared to LASIK, and no signs of corneal ectasia staging within our standard criteria.


Asunto(s)
Astigmatismo , Queratomileusis por Láser In Situ , Miopía , Herida Quirúrgica , Astigmatismo/diagnóstico , Astigmatismo/cirugía , Sustancia Propia/cirugía , Estudios de Seguimiento , Humanos , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/diagnóstico , Miopía/cirugía , Refracción Ocular , Herida Quirúrgica/cirugía , Resultado del Tratamiento
2.
Acta Ophthalmol ; 99(7): e973-e983, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33433050

RESUMEN

In the context of the COVID-19 pandemic, this paper provides recommendations for medical eye care during the easing of control measures after lockdown. The guidelines presented are based on a literature review and consensus among all Spanish Ophthalmology Societies regarding protection measures recommended for the ophthalmologic care of patients with or without confirmed COVID-19 in outpatient, inpatient, emergency and surgery settings. We recommend that all measures be adapted to the circumstances and availability of personal protective equipment at each centre and also highlight the need to periodically update recommendations as we may need to readopt more restrictive measures depending on the local epidemiology of the virus. These guidelines are designed to avoid the transmission of SARS-CoV-2 among both patients and healthcare staff as we gradually return to normal medical practice, to prevent postoperative complications and try to reduce possible deficiencies in the diagnosis, treatment and follow-up of the ophthalmic diseases. With this update (5th ) the Spanish Society of Ophthalmology is placed as one of the major ophthalmology societies providing periodic and systematized recommendations for ophthalmic care during the COVID-19 pandemic.


Asunto(s)
COVID-19/transmisión , Control de Enfermedades Transmisibles/métodos , Oftalmología/normas , Equipo de Protección Personal/normas , COVID-19/epidemiología , Consenso , Oftalmopatías/terapia , Humanos , Pandemias/prevención & control , Guías de Práctica Clínica como Asunto , SARS-CoV-2 , España , Telemedicina/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA