Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Am Heart J ; 276: 39-48, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38950668

RESUMEN

BACKGROUND: Symptomatic severe aortic stenosis causes substantial morbidity and mortality when left untreated, yet recent data suggest its undertreatment. OBJECTIVE: To evaluate the efficacy of electronic physician notification to facilitate the guideline-directed management of patients with severe aortic stenosis. HYPOTHESIS: We hypothesize that patients with severe aortic stenosis who are in the care of physicians who receive the notification are more likely to undergo aortic valve replacement within one year. METHODS/DESIGN: The Electronic Physician Notification to Facilitate the Recognition and Management of Severe Aortic Stenosis (DETECT AS) trial is a randomized controlled trial and quality improvement initiative designed to evaluate the efficacy of electronic provider notification versus usual clinical care in the management of patients with severe aortic stenosis. Providers ordering an echocardiogram with findings potentially indicative of severe aortic stenosis are randomized to receive electronic notification with customized guideline recommendations for the management of severe aortic stenosis or usual care (no notification). Randomization continues until 940 patients are enrolled. SETTING: Multicentered, academic health system. OUTCOMES: The primary endpoint is the proportion of patients with severe aortic stenosis receiving an aortic valve replacement within one year of the index echocardiogram. Secondary endpoints include mortality, heart failure hospitalization, transthoracic echocardiogram utilization, aortic stenosis billing code, and cardiology/Valve Team referral. CONCLUSION: The DETECT AS trial will provide insight into whether electronic notification of providers on the presence of severe aortic stenosis and associated clinical guideline recommendations will facilitate recognition and guideline-directed management of severe aortic stenosis. TRIAL REGISTRATION: ClinicalTrials.gov, NCT05230225, https://clinicaltrials.gov/ct2/show/NCT05230225.

2.
Am Heart J ; 274: 54-64, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38621577

RESUMEN

BACKGROUND: Recent studies suggest that aortic valve replacement (AVR) remains underutilized. AIMS: Investigate the potential role of non-referral to heart valve specialists (HVS) on AVR utilization. METHODS: Patients with severe aortic stenosis (AS) between 2015 and 2018, who met class I indication for intervention, were identified. Baseline data and process-related parameters were collected to analyze referral predictors and evaluate outcomes. RESULTS: Among 981 patients meeting criteria AVR, 790 patients (80.5%) were assessed by HVS within six months of index TTE. Factors linked to reduced referral included increasing age (OR: 0.95; 95% CI: 0.94-0.97; P < .001), unmarried status (OR: 0.59; 95% CI: 0.43-0.83; P = .002) and inpatient TTE (OR: 0.27; 95% CI: 0.19-0.38; P < .001). Conversely, higher hematocrit (OR: 1.13; 95% CI: 1.09-1.16; P < .001) and eGFR (OR: 1.01; 95% CI: 1.00-1.02; P = .003), mean aortic valve gradient (OR: 1.03; 95% CI: 1.01-1.04; P < .001) and preserved LVEF (OR: 1.59; 95% CI: 1.02-2.48; P = .04), were associated with increased referral likelihood. Moreover, patients assessed by HVS referral as a time-dependent covariate had a significantly lower two-year mortality risk than those who were not (aHR: 0.30; 95% CI: 0.23-0.39; P < .001). CONCLUSION: A substantial proportion of severe AS patients meeting indications for AVR are not evaluated by HVS and experience markedly increased mortality. Further research is warranted to assess the efficacy of care delivery mechanisms, such as e-consults, and telemedicine, to improve access to HVS expertise.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Derivación y Consulta , Humanos , Derivación y Consulta/estadística & datos numéricos , Femenino , Masculino , Estenosis de la Válvula Aórtica/cirugía , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano de 80 o más Años , Estudios Retrospectivos , Válvula Aórtica/cirugía , Ecocardiografía , Persona de Mediana Edad
3.
Curr Cardiol Rep ; 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39073506

RESUMEN

BACKGROUND: Obesity paradox in cardiovascular risk prediction has gained increasing attention in recent years. We aimed to investigate the impact of BMI on mortality following transcatheter aortic valve replacement (TAVR). METHODS: We performed a multi-center retrospective analysis of patients with severe aortic stenosis undergoing TAVR. Patients were categorized into: Underweight (BMI < 18.5), normal weight (18.5 ≤ BMI < 25), overweight (25 ≤ BMI < 30) and obese (BMI ≥ 30). Multivariate cox-proportional hazard model was used to compare all-cause mortality. RESULTS: Total of 6688 patients included (175 underweight, 2252 normal weight, 2368 overweight and 1893 with obesity). Mean age of patients was 81 ± 8 years with 55% males. Patients with obesity had higher prevalence of comorbidities but a lower overall STS score. Mortality at 30-days post-TAVR was lower in the obese population compared to underweight, normal weight, and overweight patients (1.6% vs. 6.9%, 3.6%, and 2.8%, respectively, p < 0.001). Similarly, 3-year mortality was lowest in patients with obesity (17.1% vs. 28.9%, 24.5% and 18.6%, respectively, p < 0.001). On multivariate analysis, long term all-cause mortality at 3-years remained significantly lower in patients with obesity compared to underweight (HR 1.74, 95% CI: 1.30-2.40, p < 0.001) and normal weight (HR: 1.41, 95% CI:1.21-1.63, p < 0.001) but not in overweight patients (HR: 1.10, 95% CI:0.94-1.28, p = 0.240). CONCLUSION: In conclusion, patients with obesity have improved short and long term mortality following TAVR with an observed progressive increase in mortality with lower BMI ranges.

4.
Struct Heart ; 8(1): 100234, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38283574

RESUMEN

In 2022, the Food and Drug Administration approved a second mitral transcatheter edge-to-edge repair device for the treatment of primary mitral regurgitation (PASCAL Precision Transcatheter Valve Repair System, Edwards Lifesciences, Irvine, CA). The PASCAL Precision system consists of a guide sheath, implant system, and accessories. The implant system consists of a steerable catheter, an implant catheter, and the implant (PASCAL or PASCAL Ace). The guide sheath and steerable catheter move and flex independently from each other and are not keyed, allowing for freedom of rotation in three dimensions. This manuscript provides an overview of the PASCAL Precision system and describes the basic and advanced steering maneuvers to facilitate effective and safe mitral transcatheter edge-to-edge repair.

5.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938841

RESUMEN

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

6.
Am J Cardiol ; 213: 140-145, 2024 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-38134979

RESUMEN

Transcatheter aortic valve replacement (TAVR) has emerged as a successful treatment option for severe aortic stenosis. However, the long-term outcomes of TAVR in nonagenarians is lacking. We aimed to examine the long-term mortality and quality of life in nonagenarians after TAVR. This is a multicenter, retrospective analysis on patients with severe aortic stenosis who underwent TAVR. Patients were divided into 2 groups: nonagenarians (age ≥90 years) and age <90 years. The Kansas City cardiomyopathy questionnaire (KCCQ) and New York Heart Association (NYHA) scores were compared before and after TAVR. All-cause mortality was compared between both groups at 30 days, 1 year, and 5 years after TAVR using the Cox proportional hazard model. A total of 6,896 patients were included, of whom 591 were nonagenarians. Nonagenarians had a higher Society of Thoracic Surgeons perioperative risk of mortality (8.1 ± 4.6% vs 5.4 ± 4.2%, p <0.001) before TAVR. Both groups were similar in KCCQ and NYHA scores at baseline. At 1 year after TAVR, there was no significant difference in improvement in the KCCQ overall score between those aged <90 years and nonagenarians (-4.76, 95% confidence interval [CI] -11.4 to 1.9, p = 0.161). Similarly, there was no statistically significant difference in improvement in NYHA class between the 2 groups at 1 year (odds ratio 1.07, 95% CI 0.85 to 1.25), p = 0.526). The unadjusted 30-day (3.2% vs 2.7%, hazard ratio 1.11, 95% CI 0.70 to 1.80, p = 0.667) and 5-year (28.0% vs 26.6%, hazard ratio 1.05, 95% CI 0.89 to 1.24, p = 0.60) all-cause mortality were similar between the 2 groups. In conclusion, this study demonstrates an excellent long-term mortality rate at 5 years after TAVR in nonagenarians, comparable to patients younger than 90 years. There is a significant and enduring improvement in functional status in nonagenarians, observed up to 1 year after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Humanos , Calidad de Vida , Nonagenarios , Resultado del Tratamiento , Estudios Retrospectivos , Válvula Aórtica/cirugía , Factores de Riesgo
7.
medRxiv ; 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38746173

RESUMEN

Current techniques to image the microstructure of the heart with diffusion tensor MRI (DTI) are highly under-resolved. We present a technique to improve the spatial resolution of cardiac DTI by almost 10-fold and leverage this to measure local gradients in cardiomyocyte alignment or helix angle (HA). We further introduce a phenomapping approach based on voxel-wise hierarchical clustering of these gradients to identify distinct microstructural microenvironments in the heart. Initial development was performed in healthy volunteers (n=8). Thereader, subjects with severe but well-compensated aortic stenosis (AS, n=10) were compared to age-matched controls (CTL, n=10). Radial HA gradient was significantly reduced in AS (8.0±0.8°/mm vs. 10.2±1.8°/mm, p=0.001) but the other HA gradients did not change significantly. Four distinct microstructural clusters could be idenJfied in both the CTL and AS subjects and did not differ significantly in their properties or distribution. Despite marked hypertrophy, our data suggest that the myocardium in well-compensated AS can maintain its microstructural coherence. The described phenomapping approach can be used to characterize microstructural plasticity and perturbation in any organ system and disease.

8.
J Soc Cardiovasc Angiogr Interv ; 3(7): 102146, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39131997

RESUMEN

Background: The choice of transcatheter aortic valve replacement (TAVR) prosthesis is crucial in optimizing short- and long-term outcomes. The objective of this study was to conduct a meta-analysis comparing outcomes of third-generation balloon-expandable valves (BEV) vs self-expanding valves (SEV). Methods: Electronic databases were searched from inception to June 2023 for studies comparing third-generation BEV vs SEV. Primary outcome was all-cause mortality. Secondary outcomes included clinical and hemodynamic end points. Random-effects models were used to calculate pooled odds ratios (ORs) or weighted mean differences (WMDs). Results: The meta-analysis included 16 studies and 10,174 patients (BEV, 5753 and SEV, 4421). There were no significant differences in 1-year all-cause mortality (OR, 1.15; 95% CI, 0.89-1.48) between third-generation BEV vs SEV. TAVR with third generation BEV was associated with a significantly lower risk of TIA/stroke (OR, 0.62; 95% CI, 0.44-0.87), permanent pacemaker implantation (OR, 0.55; 95% CI, 0.44-0.70), and ≥moderate paravalvular leak (PVL, OR, 0.43; 95% CI, 0.25-0.75), and higher risk of ≥moderate patient-prosthesis mismatch (OR, 3.76; 95% CI, 2.33-6.05), higher mean gradient (WMD, 4.35; 95% CI, 3.63-5.08), and smaller effective orifice area (WMD, -0.30; 95% CI, -0.37 to -0.23), compared with SEV. Conclusion: In this meta-analysis, TAVR with third-generation BEV vs SEV was associated with similar all-cause mortality, lower risk of TIA/stroke, permanent pacemaker implantation, and ≥moderate PVL, but higher risk of ≥moderate patient-prosthesis mismatch, higher mean gradient, and smaller effective orifice area. Large, adequately powered randomized trials are needed to evaluate long-term outcomes of TAVR with latest generations of BEV vs SEV.

9.
JACC Adv ; 3(8): 101116, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39108421

RESUMEN

Background: Transcatheter aortic valve replacement (TAVR) is an important treatment option for patients with severe symptomatic aortic stenosis. It is important to identify predictors of excellent outcomes (good clinical outcomes, more time spent at home) after TAVR that are potentially amenable to improvement. Objectives: The purpose of the study was to use machine learning to identify potentially modifiable predictors of clinically relevant patient-centered outcomes after TAVR. Methods: We used data from 8,332 TAVR cases (January 2016-December 2021) from 21 hospitals to train random forest models with 57 patient characteristics (demographics, comorbidities, surgical risk score, lab values, health status scores) and care process parameters to predict the end point, a composite of parameters that designated an excellent outcome and included no major complications (in-hospital or at 30 days), post-TAVR length of stay of 1 day or less, discharge to home, no readmission, and alive at 30 days. We used recursive feature elimination with cross-validation and Shapley Additive Explanation feature importance to identify parameters with the highest predictive values. Results: The final random forest model retained 29 predictors (15 patient characteristics and 14 care process components); the area under the curve, sensitivity, and specificity were 0.77, 0.67, and 0.73, respectively. Four potentially modifiable predictors with relatively high Shapley Additive Explanation values were identified: type of anesthesia, direct movement to stepdown unit post-TAVR, time between catheterization and TAVR, and preprocedural length of stay. Conclusions: This study identified four potentially modifiable predictors of excellent outcome after TAVR, suggesting that machine learning combined with hospital-level data can inform modifiable components of care, which could support better delivery of care for patients undergoing TAVR.

10.
Circ Cardiovasc Interv ; 17(2): e013298, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38235547

RESUMEN

BACKGROUND: Frailty associates with worse outcomes after transcatheter aortic valve replacement (TAVR). Sarcopenia underlies frailty, but the association between a comprehensive assessment of sarcopenia-muscle mass, strength, and performance-and outcomes after TAVR has not been examined. METHODS: From a multicenter prospective registry of patients with symptomatic severe aortic stenosis undergoing TAVR, 445 who had a preprocedure computed tomography and clinical assessment of frailty were included. Cross-sectional muscle (psoas and paraspinal) areas were measured on computed tomography and indexed to height. Gait speed and handgrip strength were obtained, and patients were dichotomized into fast versus slow; strong versus weak; and normal versus low muscle mass. As measures of body composition, cross-sectional fat (subcutaneous and visceral) was measured and indexed to height. RESULTS: The frequency of patients who were slow, weak, and had low muscle mass was 56%, 59%, and 42%, respectively. Among the 3 components of sarcopenia, only slower gait speed (muscle performance) was independently associated with increased post-TAVR mortality (adjusted hazard ratio, 1.12 per 0.1 m/s decrease [95% CI, 1.04-1.21]; P=0.004; adjusted hazard ratio, 1.38 per 1 SD decrease [95% CI, 1.11-1.72]; P=0.004). Meeting multiple sarcopenia criteria was not associated with higher mortality risk than fewer. Lower indexed visceral fat area (adjusted hazard ratio, 1.48 per 1 SD decrease [95% CI, 1.15-1.89]; P=0.002) was associated with mortality but indexed subcutaneous fat was not. Death occurred in 169 (38%) patients. CONCLUSIONS: Among patients with symptomatic severe aortic stenosis and comprehensive sarcopenia and body composition phenotyping, gait speed was the only sarcopenia measure associated with post-TAVR mortality. Lower visceral fat was also associated with increased risk pointing to an obesity paradox also observed in other patient populations. These findings reinforce the clinical utility of gait speed as a measure of risk and a potential target for adjunctive interventions alongside TAVR to optimize clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Sarcopenia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Sarcopenia/diagnóstico por imagen , Sarcopenia/complicaciones , Fragilidad/diagnóstico , Fragilidad/complicaciones , Resultado del Tratamiento , Fuerza de la Mano , Estudios Transversales , Medición de Riesgo , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Composición Corporal , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
11.
J Soc Cardiovasc Angiogr Interv ; 2(6Part A): 101067, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-39129880

RESUMEN

A multidisciplinary care team model, or Heart Team approach, has become a central tenet of cardiovascular care. Though initially applied to the management of heart transplantation and subsequently complex coronary artery disease, the Heart Team is now utilized broadly across cardiovascular medicine, including in the treatment of valvular disease, pulmonary embolism, cardiogenic shock, high-risk pregnancies in patients with pre-existing cardiovascular disease, and adult congenital heart disease. The Heart Team model improves interdisciplinary collaboration among specialties, adherence to societal guidelines, and shared decision-making with patients and families. In this review, we highlight the development and rationale supporting the Heart Team model, address the challenges of implementing a multidisciplinary care team, and discuss the optimal methods to continue to build, optimize, and implement this approach.

12.
J Soc Cardiovasc Angiogr Interv ; 2(1): 100531, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-39132543

RESUMEN

Background: Anemia is associated with increased mortality in patients undergoing transcatheter aortic valve replacement (TAVR); however, data on the effect of the severity of and recovery from anemia on clinical outcomes are limited. This study examined the impact of the severity of and recovery from anemia after TAVR. Methods: Patients with symptomatic, severe aortic stenosis across all surgical risk groups from the Placement of Aortic Transcatheter Valves (PARTNER) I, II, and III trials and registries who underwent TAVR were analyzed. Baseline anemia was defined as mild (hemoglobin [Hb] level ≥11.0 g/dL and <13.0 g/dL for men and ≥11.0 g/dL and <12.0 g/dL for women) and moderate-to-severe anemia (Hb level <11.0 g/dL). Recovery from anemia was defined as an increase of ≥1 g/dL in the Hb level. Patients with missing Hb information and major bleeding within 30 days were excluded. The association of the severity of and recovery from anemia with clinical outcomes was analyzed using multivariable Cox proportional hazards regression models. The primary outcome was 1-year all-cause mortality. Results: The Kaplan-Meier estimate for 1-year all-cause mortality was 5.4%, 8.2%, and 14.5% in patients with no, mild, and moderate-to-severe anemia, respectively (P < .001). Recovery from anemia at 30 days occurred in 8.4% (229/2730) of all patients. Compared with those without baseline or 30-day anemia, patients with recovery from anemia had similar 1-year mortality (hazard ratio, 1.02; CI, 0.50-2.08; P = .96), whereas those without recovery from anemia had higher 1-year mortality (hazard ratio, 1.82; CI, 1.17-2.85; P = .009). Conclusions: In patients undergoing TAVR, moderate-to-severe anemia is independently associated with increased 1-year mortality, and recovery from anemia after TAVR is associated with favorable outcomes. Further efforts are needed to determine whether preprocedural correction of anemia improves post-TAVR outcomes.

13.
J Soc Cardiovasc Angiogr Interv ; 1(2): 100025, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-39132569

RESUMEN

Background: Clinical guidelines recommend patients with aortic stenosis (AS) being considered for transcatheter aortic valve implantation or surgical aortic valve replacement to participate in shared decision-making (SDM) with a heart valve team (HVT). Data supporting these recommendations are limited. This project gathered data on feasibility and preliminary efficacy of a decision aid (DA) in decision-making for patients with severe AS deciding between transcatheter aortic valve implantation and surgical aortic valve replacement. Methods: This institutional review board-approved randomized pilot trial assigned eligible patients to receive either the American College of Cardiology's DA for patients with AS or usual care. Patients were surveyed after their visit regarding knowledge, treatment-preference concordance, SDM (SDM process and CollaboRATE Scales), and decisional conflict. Patients were followed for 3 months to collect data on treatment received. Results: Of 62 patients approached, 59 (95%) consented and participated. The average age of participants was 72 years, they were 100% white, and 32% of them were female. Intervention patients had higher knowledge scores (75.6 vs 65.5) and more frequently reported CollaboRATE top scores (67% vs 33%) than usual care patients. No other group comparisons reached significance. Patients who saw both members of the HVT before survey completion reported higher SDM process scores than those who saw only 1 specialist (3.1 vs 2.4). Conclusions: The study exceeded enrollment targets, indicating feasibility. Results suggest the American College of Cardiology's DA improved patient knowledge and communication scores. Patients who met with both members of the HVT reported higher SDM. These observations highlight the importance of SDM and multidisciplinary HVT assessment in the management of severe AS.

14.
J Soc Cardiovasc Angiogr Interv ; 1(4): 100039, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-39131947

RESUMEN

Background: Patent foramen ovale (PFO) is a vestigial congenital cardiovascular structure present in around 25% of adults. In most cases, PFO is entirely benign and requires no treatment. However, it may cause serious complications under certain circumstances. Objective: These evidence-based guidelines from the Society for Cardiovascular Angiography and Interventions (SCAI) aim to support patients, clinicians, and other stakeholders in decisions about management of PFO. Methods: SCAI convened a multidisciplinary guideline panel balanced to minimize potential bias from conflicts of interest. The Evidence Foundation, a registered 501(c)(3) nonprofit organization, provided methodological support for the guideline-development process. Following the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach, the guideline panel formulated and prioritized clinical questions in population, intervention, comparison, outcome (PICO) format. A separate technical review team of clinical and methodological experts conducted systematic reviews of the evidence, synthesized data, and graded the certainty of the evidence across outcomes. The guideline panel then reconvened to formulate recommendations and supporting remarks informed by the results of the technical review and additional contextual factors described in the GRADE evidence-to-decision framework. Results: The panel agreed on 13 recommendations to address variations on 5 clinical scenarios. Conclusions: Key recommendations address patient selection for PFO closure in the prevention of recurrent PFO-associated stroke, including populations not commonly included in randomized studies, and scenarios where the PFO closure might serve a role in the prevention of other outcomes such as migraine headaches and decompression illness. The panel has also identified future research priorities to advance the field.

15.
J Soc Cardiovasc Angiogr Interv ; 1(4): 100389, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-39131944

RESUMEN

Evidence-based recommendations for clinical practice are intended to help health care providers and patients make decisions, minimize inappropriate practice variation, promote effective resource use, improve clinical outcomes, and direct future research. SCAI has been engaged in the creation and dissemination of clinical guidance documents since the 1990s. These documents are a cornerstone of the Society's education, advocacy, and quality improvement initiatives. The Publications Committee is charged with the oversight of SCAI's clinical documents program and has published the first iteration of this manual of standard operating procedures in 2019 to ensure consistency, methodological rigor, and transparency in the development and endorsement of the Society's documents. The manual has been updated based on feedback from the implementation of the original version to add specificity and expand the breadth of available document formats. The manual is intended for reference by the Publications Committee, document writing groups, external collaborators, SCAI representatives, peer reviewers, and anyone seeking information about the SCAI documents program.

18.
Prog Cardiovasc Dis ; 60(4-5): 500-507, 2018. graf, tab
Artículo en Inglés | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1065739

RESUMEN

BACKGROUND: Diabetic patients account for an increasing number of patients undergoing percutaneous coronary intervention (PCI). However, diabetes mellitus (DM) is associated with increased residual platelet activity during dual antiplatelet treatment (DAPT) and DM patients have worse clinical outcomes after PCI as compared to non-DM. OBJECTIVE: To evaluate efficacy and safety of short duration DAPT (S-DAPT) and long duration DAPT (L-DAPT) after drug eluting stent (DES) implantation in DM and non-DM patients.METHODS:We searched Medline, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) to identify randomized controlled trials (RCTs) assessing the effect of S-DAPT versus L-DAPT after DES implantation in DM and non-DM patients. Efficacy endpoints were all-cause mortality, cardiac mortality, myocardial infarction (MI), stent thrombosis (ST), target vessel revascularization (TVR), and composite end point of net adverse clinical events (NACE) (all-cause mortality, cardiac mortality, MI, ST, TVR, stroke, major bleeding). Safety endpoints were major bleeding and stroke. Event rates were compared using a forest plot of relative risk using a random effects model...


Asunto(s)
Diabetes Mellitus , Stents Liberadores de Fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA