Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Cytometry A ; 105(3): 181-195, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-37984809

RESUMEN

Multiparameter flow cytometry (MFC) has emerged as a standard method for quantifying measurable residual disease (MRD) in acute myeloid leukemia. However, the limited number of available channels on conventional flow cytometers requires the division of a diagnostic sample into several tubes, restricting the number of cells and the complexity of immunophenotypes that can be analyzed. Full spectrum flow cytometers overcome this limitation by enabling the simultaneous use of up to 40 fluorescent markers. Here, we used this approach to develop a good laboratory practice-conform single-tube 19-color MRD detection assay that complies with recommendations of the European LeukemiaNet Flow-MRD Working Party. We based our assay on clinically-validated antibody clones and evaluated its performance on an IVD-certified full spectrum flow cytometer. We measured MRD and normal bone marrow samples and compared the MRD data to a widely used reference MRD-MFC panel generating highly concordant results. Using our newly developed single-tube panel, we established reference values in healthy bone marrow for 28 consensus leukemia-associated immunophenotypes and introduced a semi-automated dimensionality-reduction, clustering and cell type identification approach that aids the unbiased detection of aberrant cells. In summary, we provide a comprehensive full spectrum MRD-MFC workflow with the potential for rapid implementation for routine diagnostics due to reduced cell requirements and ease of data analysis with increased reproducibility in comparison to conventional FlowMRD routines.


Asunto(s)
Leucemia Mieloide Aguda , Humanos , Citometría de Flujo/métodos , Reproducibilidad de los Resultados , Leucemia Mieloide Aguda/diagnóstico , Médula Ósea/metabolismo , Neoplasia Residual/diagnóstico
2.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1275-1286, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38501253

RESUMEN

PURPOSE: Restricted kinematic alignment (rKA) in total knee arthroplasty (TKA) and medial pivot (MP) knee designs already showed superior outcomes in independent comparative studies. The objective of this study was to assess whether rKA with MP TKA provides better clinical and functional outcomes compared to mechanical alignment (MA) with MP TKA. METHODS: This is a randomised, parallel two group study involving a total of 98 patients with end-stage knee osteoarthritis. Patients were randomly allocated to either rKA or MA TKA procedures conducted with a MP prothesis using patient-specific instruments between 2017 and 2020. Final follow-up was at 2 years postoperatively. Demographic data and clinical and functional scores (Oxford knee score, knee society score [KSS], Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC], forgotten joint score [FJS]) were collected and compared preoperative, 1 year postoperative and 2 years postoperative. Coronal plane alignment of the knee and functional knee phenotype classification were recorded. RESULTS: A total of 47 patients (rKA) and 51 patients (MA) were included in final analysis. Superior joint awareness scores (FJS) were found at 1 year postoperative for rKA (62.2 vs. 52.4, p = 0.04). KSS subscores (expectation score, satisfaction score) improved with rKA with significant differences at both 1 and 2 years postoperatively. Major differences between rKA and MA were found in subgroup analysis of varus and neutral CPAK phenotypes. Both 1 year and 2 years postoperatively, FJS was significantly better in KA compared with MA in varus CPAK phenotypes (63.1 vs. 44.9, p = 0.03; 71.1 vs. 46.0, p = 0.005). Further clinical and functional scores showed improvement in the varus CPAK phenotypes with predominantly significant improvement in the expectation and satisfaction KSS subscores. No significant differences were found in the comparison of rKA and MA in neutral CPAK phenotypes. CONCLUSION: The rKA of MP TKA design shows superior patient satisfaction and self-reported function when compared to MA MP TKA. Furthermore, rKA MP TKA shows superior joint awareness at early postoperative stage. The most important clinical relevance of this study is the clear superiority of rKA in varus phenotypes. LEVEL OF EVIDENCE: Level II.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Satisfacción del Paciente , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Masculino , Femenino , Estudios Prospectivos , Osteoartritis de la Rodilla/cirugía , Anciano , Persona de Mediana Edad , Fenómenos Biomecánicos , Diseño de Prótesis , Rango del Movimiento Articular
3.
J Arthroplasty ; 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38879091

RESUMEN

BACKGROUND: The coronal plane alignment of the knee (CPAK) classification system divides coronal knee anatomy into 9 phenotypes, suggesting different soft tissue balancing is needed for optimal outcomes. We investigated the interplay between CPAK phenotypes and gap stress curves throughout the knee's range of motion, aiming to understand their impact on total knee arthroplasty balancing. METHODS: There were 1,112 total knee arthroplasty cases from 2 imageless robotic assisted navigation systems using posterior stabilized implants that were classified into CPAK phenotypes. Medial and lateral initial gap values were measured throughout the knee flexion-extension arc, gap curve morphologies were generated, and mediolateral (ML) gap balance was calculated for each phenotype. The most common phenotypes were included in this study, CPAK I to VI. RESULTS: Each phenotype exhibited a distinct gap curve morphology. Type I maintained the largest ML gap difference (-3.6 to -2.1), with the medial compartment tightest in extension. Type II showed relative laxity in the lateral compartment compared to the medial gap (-1.0 to -1.9), with the medial compartment tightening through flexion. Type III had a looser medial and tighter lateral compartment in extension that inverts to a tighter medial compartment in deep flexion (2.1 to -0.8), while Type IV showed a decreasing compartment difference with increased flexion (-3.7 to 0.6). Type V had fluctuating tightness (-0.6 to 1.8), and Type VI had the medial compartment tightening more with flexion (0.6 to 1.8). CONCLUSIONS: The distinct stress curves and ML gap behavior provide a "fingerprint" for each corresponding CPAK phenotype. Investigating these morphologies can help determine the best phenotype-specific treatments, including alignment strategy, implant selection, and gap balance, for optimal functional and patient outcomes.

4.
J Surg Oncol ; 128(7): 1160-1170, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37530536

RESUMEN

BACKGROUND AND OBJECTIVES: Surgical resection with microscopically negative margins constitutes one of the key elements of a curative therapeutic approach for localized sarcomas. However, the prognostic value of quantitative margin width remains controversial. We sought to determine the prognostic significance of margin status and margin width for local recurrence (LR), distant recurrence (DR), and overall survival. METHODS: Retrospective analysis of 210 patients undergoing resection of localized sarcoma between 1997 and 2018 at a national sarcoma reference center. RESULTS: Logistic regression did not reveal an effect of metric margin width as a prognostic factor for LR (odds ratio [OR] = 0.98, p = 0.574), DR (OR = 1, p = 0.908), or overall survival (hazard ratio = 0.98, 95% confidence interval = 0.73-1.20, p = 0.609). Subgroup analysis revealed no differences between complete first resections (R0) and re-resections (re-R0) following unplanned R1-resections for LR (p = 0.727) and overall survival (p = 0.125), but a significantly higher DR-rate in re-R0 cases (p = 0.022). CONCLUSIONS: Achieving a negative margin is essential in sarcoma surgery, however, metric margin width was not associated with disease-specific outcomes. Re-resection of unplanned R1-resections should be performed to control for LR and overall survival rates. As re-R0 cases were at significantly higher risk of DR, these patients should be followed up closely in standardized surveillance protocols.

5.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3871-3879, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36917247

RESUMEN

PURPOSE: A key part of kinematic alignment (KA) and functional alignment (FA) is to restore the natural femoral joint line, in particular the medial joint line. KA is known to reproduce the femoral joint line accurately; however, direct comparisons with other surgical techniques such as FA are currently lacking. The purpose of this study was to evaluate differences of alignment parameters in KA and FA techniques with a special focus given to the femoral joint line. METHODS: We performed a retrospective radiological analysis of pre- and postoperative long leg radiographs of 221 consecutive patients with varus or neutral leg alignment, who underwent primary total knee arthroplasty (TKA) procedures from 2018 to 2020. Patients were assigned to one of four groups: (1) FA: image-based robotic-assisted TKA, (2) FA: imageless robotic-assisted TKA, (3): restricted KA: 3D cutting block-assisted (patient-specific instruments, PSI) TKA, (4): unrestricted KA: calipered technique. Patients' radiographs were (re)-analyzed for overall limb alignment, medial proximal tibial angle (MPTA), lateral distal femoral angle (LDFA), as well as medial and lateral femoral joint line alteration. Statistical significance was determined using unpaired t testing (FA vs. KA group) and one-way ANOVA (subgroup analyses). RESULTS: Comparisons of KA vs. FA, as well as individual subgroups of KA and FA did not show any differences in the accuracy of medial joint line reconstruction (< 2 mm, p = 0.384, p = 0.744, respectively) and LDFA alteration (< 2°, p = 0.997, 0.921, respectively). Correction of MPTA (3.4° vs. 2.2°) and lateral femoral joint line (2.1 mm vs. 1.5 mm) was higher for FA and FA subgroups compared to KA and KA subgroups (both p < 0.001). CONCLUSION: Kinematic and functional alignments showed a comparable accuracy in reconstruction of the medial femoral joint line and femoral joint line orientation. Increased correction of MPTA and lateral femoral joint line was recorded with FA techniques. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Fenómenos Biomecánicos , Estudios Retrospectivos , Artroplastia de Reemplazo de Rodilla/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Osteoartritis de la Rodilla/cirugía
6.
Arch Orthop Trauma Surg ; 143(6): 2813-2819, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35507089

RESUMEN

The aim of the study was to examine the noise exposure for operating theater staff during total knee arthroplasty (TKA) with three different robot systems. There is already evidence that noise exposure during TKA performed manually exceeds recommended guidelines for occupational noise. Therefore, if surgical staff is exposed to it for several years, the development of noise-inducing hearing loss (NIHL) is significantly increased. To investigate the noise exposure during robot-assisted TKA, the study measured the average noise and the peak sound pressure during TKA with MAKO robot (Stryker, Kalamazoo, Michigan, United States), NAVIO robot (Smith and Nephew, London, Great Britain), and CORI robot (Smith and Nephew, London, Great Britain) using a class 1 sound level meter. Each robot system exceeds the recommended guidelines from the national institute for occupational safety and health. While the MAKO robot had the highest average sound level (93.18 dB(A)) of the three robot systems (NAVIO: 88.88 dB(A), CORI: 89.38 dB(A)), the peak sound level was the highest with the NAVIO Robot (134.48 dB(C)) compared to the MAKO Robot (128.98 dB(C)) and CORI robot (126.48 dB(C)). Robot-assisted TKA is a risk factor for NIHL, like manually performed TKA. Further research for decreasing the noise exposure during TKA is needed to minimize the hearing loss in operating theater staff.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Pérdida Auditiva Provocada por Ruido , Ruido en el Ambiente de Trabajo , Robótica , Humanos , Factores de Riesgo
7.
Arch Orthop Trauma Surg ; 143(6): 3423-3430, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36241901

RESUMEN

INTRODUCTION: Complex primary total knee arthroplasties (TKA) are reported to be associated with excessive episode of care (EOC) costs as compared to noncomplex procedures. The impact of robotic assistance (rTKA) on economic outcome parameters in greater case complexity has not been described yet. The purpose of this study was to investigate economic outcome parameters in the 90-days postoperative EOC in robotic-assisted complex versus noncomplex procedures. MATERIALS AND METHODS: This study is a retrospective, single-center review of 341 primary rTKAs performed between 2017 and 2020. Patient collective was stratified into complex (n = 218) and noncomplex TKA (n = 123) based on the presence of the following criteria: Obese BMI, coronal malalignment, flexion contracture > 10°, posttraumatic status, previous correction osteotomy, presence of hardware requiring removal during surgery, severe rheumatoid arthritis. Group comparison included surgery duration, length of stay (LOS), surgical site complications, readmissions, and revision procedures in the 90-days EOC following rTKA. RESULTS: The mean surgery duration was marginally longer in complex rTKA, but showed no significant difference (75.26 vs. 72.24 min, p = 0.258), neither did the mean LOS, which was 8 days in both groups (p = 0.605). No differences between complex and noncomplex procedures were observed regarding 90-days complication rates (7.34 vs. 4.07%, p = 0.227), readmission rates (3.67 vs. 3.25%, p = 0.841), and revision rates (2.29 vs. 0.81%, p = 0.318). CONCLUSIONS: Robotic-assisted primary TKA reduces the surgical time, inpatient length of stay as well as 90-days complication and readmission rates of complex TKA to the level of noncomplex TKA. Greater case complexity does not seem to have a negative impact on economic outcome parameters when surgery is performed with robotic assistance.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Procedimientos Quirúrgicos Robotizados/métodos , Tiempo de Internación , Estudios Retrospectivos , Readmisión del Paciente
8.
Arch Orthop Trauma Surg ; 143(6): 2929-2941, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35699755

RESUMEN

PURPOSE: Young and active patients suffering early degenerative changes of the medial compartment with an underlying straight-leg axis do face a therapeutical gap as unloading of the medial compartment cannot be achieved by high tibial osteotomy. Extracapsular absorbing implants were developed to close this existing therapeutical gap. Purpose of the present cadaveric biomechanical study was to compare the unloading effect of the knee joint after implantation of an extra-articular absorber system (ATLAS) in comparison to open-wedge high tibial osteotomy (OW-HTO) under physiological conditions. The hypothesis of the study was that implantation of an extra-capsular absorber results in an unloading effect comparable to the one achievable with OW-HTO. METHODS: Eight fresh-frozen cadaveric knees were tested under isokinetic flexion-extension motions and physiological loading using a biomechanical knee simulator. Tibiofemoral area contact and peak contact pressures were measured using pressure-sensitive film in the untreated medial compartment. The tibiofemoral superior-inferior, latero-medial translation and varus/valgus rotation were measured with a 3D tracking system Polaris. Pressures and kinematics changes were measured after native testing, ATLAS System implantation and OW-HTO (5° and 10° correction angles) performed with an angular stable internal fixator (TomoFix). RESULTS: The absorber device decreased the pressure in the medial compartment near full extension moments. Implantation of the ATLAS absorbing system according to the manufacturers' instruction did not result in a significant unloading effect. Deviating from the surgery manual provided by the manufacturer the implantation of a larger spring size while applying varus stress before releasing the absorber resulted in a significant pressure diminution. Contact pressure decreased significantly Δ0.20 ± 0.04 MPa p = 0.044. Performing the OW-HTO in 5° correction angle resulted in significant decreased contact pressure (Δ0.25 ± 0.10 MPa, p = 0.0036) and peak contact pressure (Δ0.39 ± 0.38 MPa, p = 0.029) compared with the native test cycle. With a 10° correction angle, OW-HTO significantly decreased area contact pressure by Δ0.32 ± 0.09 MPa, p = 0.006 and peak contact pressure by Δ0.48 ± 0.12 MPa, p = 0.0654 compared to OW-HTO 5°. Surgical treatment did not result in kinematic changes regarding the superior-inferior translation of the medial joint section. A significant difference was observed for the translation towards the lateral compartment for the ATLAS system Δ1.31 ± 0.54 MPa p = 0.022 and the osteotomy Δ3.51 ± 0.92 MPa p = 0.001. Furthermore, significant shifting varus to valgus rotation of the treated knee joint was verified for HTO 5° about Δ2.97-3.69° and for HTO 10° Δ4.11-5.23° (pHTO 5 = 0.0012; pHTO 10 = 0.0007) over the entire extension cycle. CONCLUSION: OW-HTO results in a significant unloading of the medial compartment. Implantation of an extra-capsular absorbing device did not result in a significant unloading until the implantation technique was applied against the manufacturer's recommendation. While the clinical difficulty for young and active patients with straight-leg axis and early degenerative changes of the medial compartment persists further biomechanical research to develop sufficient unloading devices is required.


Asunto(s)
Osteoartritis de la Rodilla , Tibia , Humanos , Fenómenos Biomecánicos , Tibia/cirugía , Cadáver , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiología , Osteoartritis de la Rodilla/cirugía , Osteotomía/métodos
9.
J Orthop Sci ; 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36462996

RESUMEN

BACKGROUND: Periprosthetic joint infection (PJI) is one of the most common reason for implant failure in arthroplasty. Surgical therapy is essential but there is no standardized guideline to determine infection eradication in multiple-step revision surgery. To date, clinical and laboratory inflammation markers and preoperative arthrocentesis are controversial to evaluate the infection status before reimplantation and therefore are often combined. Drain fluid cultures enable a microbiological analysis without need for further invasive procedure after revision surgery. This retrospective study evaluates the diagnostic performance of drain fluid cultures in diagnosing infection persistence according to the MSIS definition of PJI. METHODS: Drain samples have been taken after every revision surgery for microbiological testing. Afterwards, the results have been assigned to the infection status according to the diagnostic criteria of the MSIS definition of PJI. RESULTS: 1084 revision surgeries in 183 patients have been included, resulting in a total sample size of 1552 drain fluid cultures. Overall sensitivity was 36.0%, specificity was 90.7% and ROC-AUC was 0.63. CONCLUSION: Due to a high specificity and a low sensitivity drain fluid cultures can rule in but cannot rule out infection persistence in PJI.

10.
Unfallchirurg ; 125(5): 361-370, 2022 May.
Artículo en Alemán | MEDLINE | ID: mdl-35312794

RESUMEN

The importance of 3D printing applications in the surgery of musculoskeletal tumors has increased in recent years. Even prior to the era of 3D printing, computer-assisted techniques, such as navigation, have proved their utility. Due to the variable appearance of bone tumors, there is a need for individual solutions. The 3D printing can be used for the development of anatomical demonstration models, the construction of patient-specific instruments and custom-made implants. For these three applications, different regulatory hurdles exist. Especially for the resection of pelvic tumors, 3D printing technologies seem to provide advantages due to the complicated anatomy and the proximity to relevant neurovascular structures. With the introduction of titanium printing, construction of individualized implants that fit exactly into the defect became feasible.


Asunto(s)
Neoplasias Óseas , Enfermedades Musculoesqueléticas , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/cirugía , Humanos , Modelos Anatómicos , Impresión Tridimensional , Prótesis e Implantes
11.
Unfallchirurg ; 125(1): 59-65, 2022 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-34889969

RESUMEN

With rising numbers of revisions of total arthroplasty procedures of the lower extremities, the annual number of cases of implant-associated infection are also increasing. The conventional two-stage replacement strategy often leads to increased morbidity and mortality of patients; however, in the literature a one-stage exchange procedure shows equally good results if the indications are strictly defined. In addition to the correct diagnostics, the patient history, the inserted implant, the state of health and when applicable the pathogens present play an important role. If, among other factors, the pathogen is uncomplicated combined with a good bone and soft tissue situation and without a large number of previous operations, a single stage replacement of the endoprosthesis may be a suitable option. Despite existing controversies in the literature, this treatment approach seems to demonstrate a reduced hospitalization, reduced costs and improved patient satisfaction with the same re-revision rate. This review article explains the strategic approach to chronic infections of endoprostheses of the lower extremities based on clinical examples and a review of the current literature.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Antibacterianos/uso terapéutico , Desbridamiento , Humanos , Infección Persistente , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
12.
Arch Orthop Trauma Surg ; 141(12): 2119-2128, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34259927

RESUMEN

INTRODUCTION: Robotic-assisted surgery techniques are increasing in total knee arthroplasty (TKA). One crucial point is the prolonged time of surgery. The primary objective of this study was to determine the learning curve necessary to minimize the time of surgery. The secondary objective was to evaluate the accuracy of the implant alignment when using an imageless robotic system for TKA. MATERIALS AND METHODS: In a case-control study, the first 70 consecutive robotic-assisted TKA procedures performed by a single senior surgeon were analyzed with regard to surgery time and implant alignment by comparing the intraoperative plan with the postoperative alignment. The evaluation of the learning curve with respect to surgery time was conducted using cumulative summation (CUSUM) analysis. The joint line height was measured with a new technique. Surgery time and joint line reconstruction were compared to 70 consecutive conventional TKA procedures. RESULTS: The learning curve for robotic TKA was completed after 11 cases. The learning curve did not influence the accuracy of joint line obliquity, joint line height, or limb alignment. The intraoperative plan designed for the robotic system was precisely implemented. The mean skin-to-skin time in the robotic group after the learning curve was completed did not differ from that in the manual group. A significant positive correlation was observed between the preoperative hip-knee-ankle angle and the postoperative distalization of the joint line in the robotic-assisted TKA group. CONCLUSION: After completing the initial learning curve of 11 cases, the surgery time required to perform imageless robotic handpiece-assisted TKA was similar to that for the conventional technique. However, no learning curve was observed for the implant positioning when using the imageless robotic system. The implementation of the intraoperative plan was accurate up to < 2°. The precision of the system allows the implementation of different joint balancing approaches between valgus and varus morphotypes.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Estudios de Casos y Controles , Humanos , Articulación de la Rodilla/cirugía , Curva de Aprendizaje , Tempo Operativo
13.
Arch Orthop Trauma Surg ; 141(12): 2139-2146, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34406509

RESUMEN

PURPOSE: It is known that in uni-compartmental knee arthroplasty (UKA) low-volume surgeons have a higher complication and revision rate than high-volume surgeons. Further, robotic-assisted UKA leads to lower early revision rate as well as fewer limb and joint line outliers compared to conventional UKA. The purpose of this study was to retrospectively analyze the outliers' and revision rate of low-volume UKA surgeons with different robotic systems at short-term follow-up. METHODS: In this case-control study, 103 robotic-assisted UKAs were included. The procedures were performed between 2016 and 2019 from two low-volume UKA surgeons with an imageless (IL) (63 patients) and image-based (IB) (40 patients) robotic system. Alignment outliers, joint line (JL) reconstruction, complication and revision rates of the two different robotic systems were analyzed. The minimum follow-up was two years. Outliers were defined as a postoperative valgus malalignment greater than 182°. The surgery time for all procedures was evaluated. RESULTS: The overall revision rate was 3.9% (4 of 103). Two occurred in the IB group (5.0%) and two in the IL group (3.2%). No valgus malalignment outliers were observed in both groups. The mean JL was not distalized by more than 2 mm in both groups (IL: 1.3 ± 1.6 mm vs. IB: 1.8 ± 0.9 mm, p value 0.08). The IL procedures had a significant lower mean surgery time (55 ± 13 min vs. 68 ± 14, p value 0.001). CONCLUSION: Robotic-assisted UKA is a safe procedure in the hand of low-volume UKA surgeons. Robotic-assisted UKA minimizes overcorrection into valgus mal-alignment. Low revision rates are observed at short-term follow-up for robotic-assisted UKA. The choice of the different robotic systems has no impact on the outcome.


Asunto(s)
Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Cirujanos , Estudios de Casos y Controles , Humanos , Articulación de la Rodilla , Estudios Retrospectivos , Resultado del Tratamiento
14.
Arch Orthop Trauma Surg ; 141(2): 305-312, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33104898

RESUMEN

PURPOSE: Determining the point at which a valgus deformity requires a more invasive therapy-in this case PS TKA-is surgically challenging. Retaining the posterior cruciate ligament has both advantages and disadvantages. The aim was to evaluate the failure rate and clinical outcomes. METHODS: 248 patients with valgus gonarthrosis underwent surgical treatment: 167 CR TKA cases and 81 PS TKA cases. The KOOS and the OKS were recorded, and 201 patients (133 CR, 68 PS) were recruited into the retrospective study. The influence of BMI and degree of preoperative valgus deformity on the clinical outcome was determined. The revision rate was documented and analysed. RESULTS: Of 201 patients, 10 required revision surgery owing to instability (10/133 CR, 0/68 PS). Based on the KOOS and the OKS, no significant difference between CR TKA and PS TKA was found. BMI and degree of valgus deformity had no effect on the clinical outcome. CONCLUSIONS: No difference in the clinical outcome between the CR and PS TKA patients was found. In the CR group, significantly more patients showed 'excellent' OKS than in the PS group. However, 8.0% of the patients in the CR group and none in the PS group underwent surgery due to instability. A higher rate of dissatisfied patients in the CR group is likely. In our clinic, we no longer perform CR TKA for valgus cases.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Reoperación/estadística & datos numéricos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Humanos , Osteoartritis de la Rodilla/cirugía
15.
Orthopade ; 50(1): 51-59, 2021 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-31696261

RESUMEN

End-of-stem pain after knee and hip arthroplasty with diaphyseal supportive stems is a frequently overlooked and potentially underestimated complication. A commonly recurring clinical phenome is the symptom-free interval after surgery of weeks to months, with new onset of symptoms under stress only later. The patient is often again reliant on walking sticks. End-of-stem pain is a diagnosis of exclusion. Pain is projected into the tip of the stem, and if differential diagnoses such as loosening are excluded, then the patient might be treated with a "bending-plate". Since bone cement has a similar elastic modulus to human cortical bone, a change of method to a cemented implant can also be expedient. In the primary situation, in addition to cemented stems, the use of "split-stems" could be useful. After revision surgery of any kind, a timely cessation of pain confirms the diagnosis.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cementos para Huesos , Prótesis de Cadera , Falla de Prótesis , Humanos , Dolor , Diseño de Prótesis , Reoperación
16.
Orthopade ; 50(12): 1018-1025, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34714372

RESUMEN

BACKGROUND AND OBJECTIVE: It is evident from the national joint registries that numbers of revision knee arthroplasty operations are rising. The aim of this article is to introduce a new robotic-assisted approach in UKA to TKA revision arthroplasty and investigate the alignment accuracy, implant component use and surgery time and to compare it to primary robotic-assisted TKA arthroplasty. METHODS: This retrospective, case-control study included patients undergoing image-less robotic-assisted revision arthroplasty from UKA to TKA (n = 20) and patients undergoing image-less robotic-assisted primary TKA (control group, n = 20) from 11/2018 to 07/2020. The control group was matched based on the BMI and natural alignment. Comparison of groups was based on postoperative alignment, outlier rate, tibial insert size, lateral bone resection depth, incision-to-wound closure time. All surgeries were performed by a single senior surgeon using the same bi-cruciate stabilizing TKA system. Statistical analysis consisted of parametric t­testing and Fisher's exact test with a level of significance of p < 0.05. RESULTS: The two groups showed no differences in mean BMI, natural alignment (p > 0.05) and mean overall limb alignment. No outlier was found for OLA and slope analysis. The smallest insert size (9 mm) was used in 70% of the cases in the revision group (n = 14) and in 90% of the cases in the primary group (n = 18, p = 0.24), distal femoral and tibial resection depth showed no statistical difference (p > 0.05). The incision to wound closure time was longer in the revision group but showed no significant difference. CONCLUSION: Image-less robotic-assisted revision arthroplasty from UKA to TKA showed a comparable surgery time, and alignment accuracy in comparison to primary robotic-assisted TKA. Comparable bone preservation and subsequent tibial insert size use was observed for both groups.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Estudios de Casos y Controles , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
17.
Unfallchirurg ; 124(9): 704-719, 2021 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-34427698

RESUMEN

Pathological fractures of the extremities frequently lead to uncertainty with respect to the treatment strategy and timing. The origin of metastases is typically breast, bronchial, renal and prostate cancer and myelomas. Primary bone tumors play a subordinate role. The majority affect the femur, humerus and occasionally the tibia. Surgery is typically the first line treatment as healing under conservative treatment is unlikely. The most important goal is to relieve pain and the preservation or restoration of function. For correct assessment of indications, analysis of the fracture pattern and oncological aspects including dignity, entity, prognosis, metastatic status and the general condition of the patient need to be taken into consideration. Based on all these aspects the surgical approach can be chosen. Treatment options range from osteosynthetic stabilization and augmentation osteosynthesis up to endoprosthesis replacement. The treatment is carried out in an interdisciplinary procedure as additional measures need to be addressed in addition to the surgical treatment.


Asunto(s)
Neoplasias Óseas , Fracturas Espontáneas , Neoplasias Óseas/cirugía , Extremidades , Fémur , Fijación Interna de Fracturas , Fracturas Espontáneas/cirugía , Humanos , Húmero , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
18.
Int Orthop ; 44(1): 31-38, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31127365

RESUMEN

BACKGROUND: The diagnosis of low-grade periprosthetic joint infections (PJIs) is challenging, because patients may present with unspecific symptoms, false-negative cultures, or marginally elevated values of serum biomarkers like C-reactive protein (CRP). This may lead to the unintended implantation of a revision prosthesis into an infected surgical site with a repeat risk of short-term failure. Conversely, false diagnosis of joint infection may result in multistage revision procedures, which expose the patient to unnecessary surgical procedures and inappropriate antibiotic treatment. Here, we investigated whether synovial biomarkers can preoperatively distinguish between aseptic prosthesis loosening and low-grade joint infection and the most accurate biomarker combinations. METHODS: Inclusion criteria for the study were indication for revision arthroplasty due to aseptic implant failure, acute high-grade infection, or (suspected) low-grade infection. We prospectively collected synovial fluid of patients undergoing revision arthroplasty for quantitative measurement of alpha defensin, CRP, interleukin (IL-6), IL-10, and lipopolysaccharide binding protein (LBP). RESULTS: The classification tree method revealed alpha defensin and CRP as the most suitable biomarker combination to distinguish between aseptic loosening and low-grade joint infection. The combination of CRP > 2.0 mg/L and alpha defensin > 90.000 pg/mL correctly identified nine  of 11 patients with low-grade infection. CONCLUSIONS: Alpha defensin plus CRP seems to be the most helpful combination for pre-operative discrimination of aseptic loosening vs. low-grade joint infection.


Asunto(s)
Proteína C-Reactiva/análisis , Falla de Prótesis/etiología , Infecciones Relacionadas con Prótesis/diagnóstico , Líquido Sinovial/química , alfa-Defensinas/análisis , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/análisis , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/clasificación , Infecciones Relacionadas con Prótesis/cirugía
19.
Orthopade ; 49(5): 396-402, 2020 May.
Artículo en Alemán | MEDLINE | ID: mdl-32300822

RESUMEN

With increasing numbers of primary knee arthroplasties, the relevance and frequency of prosthesis replacement operations are increasing with a time lag. Two-zone anchoring is important. Due to bony defects, the articular surface can often no longer be used as a possible anchoring zone, so the fixation must take place in the metaphyseal and diaphyseal area of the bone. If, for various reasons, the defect is too pronounced for regular care, individually-manufactured implants can be used. These are produced on the basis of a preoperative CT as part of a two-stage change using industrial 3D printers and so-called additive manufacturing.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Falla de Prótesis , Reoperación , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Diseño de Prótesis
20.
Orthopade ; 49(7): 617-624, 2020 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-32494904

RESUMEN

BACKGROUND: Despite the growing clinical evidence "pro" kinematic alignment (KA) in primary total knee arthroplasty, the idea of this individualized implant positioning has not (yet) become established throughout the community. Many surgeons have concerns about the safety of the method and the universality of its application. Interestingly, comparative studies with unlimited indications for KA showed only little or no advantage over standard mechanical alignment in contrast to studies with strict indications showing a significant benefit. QUESTION AND METHODOLOGY: This results in a discussion about possible indication limits for KA. The aim of this article is to summarize the current evidence and theoretical considerations regarding ideal and possibly non-ideal patients. Furthermore, the paper describes the "lessons learned" of the past years as a recommendation for safe use of the method. RESULTS AND DISCUSSION: Based on current evidence, primary varus osteoarthritis appears to be a good indication for KA. A limitation, however, is extra-articular deformities that lead to a pathologically joint line angle. Instabilities of the collateral ligaments are to be considered as a contraindication. In contrast to varus type osteoarthritis, valgus deformities appear to be more critical for KA. Even though there is yet only limited evidence, especially the accompanying extra-articular pathologies of the hip and ankle pose an increased risk of failure. In our opinion, a restricted KA with an individualized component position but neutral overall limb alignment makes sense here. To analyze the suitability of KA and estimate the post-operative component position, weight-bearing long-leg x­rays are recommended. Additional stress radiography is helpful in certain cases, as is the three-dimensional analysis of the anatomy by CT or MRI scans.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Articulación del Tobillo/patología , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/patología , Osteoartritis de la Rodilla/fisiopatología , Soporte de Peso
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA