Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 33(11): 8103-8111, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37481690

RESUMEN

OBJECTIVES: Quality assurance (QA) of image interpretation plays a key role in screening and diagnostic mammography, maintaining minimum standards and supporting continuous improvement in interpreting images. However, the QA structure across Europe shows considerable variation. The European Society of Breast Imaging (EUSOBI) conducted a survey among the members to collect information on radiologists' preferences regarding QA measures in mammography. MATERIALS AND METHODS: An anonymous online survey consisting of 25 questions was distributed to all EUSOBI members and national breast radiology bodies in Europe. The questions were designed to collect demographic characteristics, information on responders' mammography workload and data about QA measures currently used in their country. Data was analysed using descriptive statistical analysis, the χ2 test, linear regression, and Durbin-Watson statistic test. RESULTS: In total, 251 breast radiologists from 34 countries completed the survey. Most respondents were providing both screening and symptomatic services (137/251, 54.6%), working in an academic hospital (85/251, 33.9%) and reading 1000-4999 cases per year (109/251, 43.4%). More than half of them (133/251, 53%) had established QA measures in their workplace. Although less than one-third (71/251, 28.3%) had to participate in regular performance testing, the vast majority (190/251, 75.7%) agreed that a mandatory test would be helpful to improve their skills. CONCLUSION: QA measures were in place for more than half of the respondents working in screening and diagnostic mammography to evaluate their breast imaging performance. Although there were substantial differences between countries, the importance of having QA in the workplace and implemented was widely acknowledged by radiologists. CLINICAL RELEVANCE STATEMENT: Although several quality assurance (QA) measures of image interpretation are recommended by European bodies or national organisations, the QA in mammography is quite heterogenous between countries and reporting settings, and not always actively implemented across Europe. KEY POINTS: The first survey that presents radiologists' preferences regarding QA measures of image interpretation in mammography. Quality assurance measures in the workplace are better-established for breast screening compared to diagnostic mammography. Radiologists consider that performance tests would help to improve their mammography interpretation skills.


Asunto(s)
Neoplasias de la Mama , Radiólogos , Humanos , Femenino , Mamografía/métodos , Mama , Encuestas y Cuestionarios , Europa (Continente) , Neoplasias de la Mama/diagnóstico por imagen , Tamizaje Masivo
2.
Eur Radiol ; 33(6): 3810-3818, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36538074

RESUMEN

OBJECTIVES: There is a clinical need for a non-ionizing, quantitative assessment of breast density, as one of the strongest independent risk factors for breast cancer. This study aims to establish proton density fat fraction (PDFF) as a quantitative biomarker for fat tissue concentration in breast MRI and correlate mean breast PDFF to mammography. METHODS: In this retrospective study, 193 women were routinely subjected to 3-T MRI using a six-echo chemical shift encoding-based water-fat sequence. Water-fat separation was based on a signal model accounting for a single T2* decay and a pre-calibrated 7-peak fat spectrum resulting in volumetric fat-only, water-only images, PDFF- and T2*-values. After semi-automated breast segmentation, PDFF and T2* values were determined for the entire breast and fibroglandular tissue. The mammographic and MRI-based breast density was classified by visual estimation using the American College of Radiology Breast Imaging Reporting and Data System categories (ACR A-D). RESULTS: The PDFF negatively correlated with mammographic and MRI breast density measurements (Spearman rho: -0.74, p < .001) and revealed a significant distinction between all four ACR categories. Mean T2* of the fibroglandular tissue correlated with increasing ACR categories (Spearman rho: 0.34, p < .001). The PDFF of the fibroglandular tissue showed a correlation with age (Pearson rho: 0.56, p = .03). CONCLUSION: The proposed breast PDFF as an automated tissue fat concentration measurement is comparable with mammographic breast density estimations. Therefore, it is a promising approach to an accurate, user-independent, and non-ionizing breast density assessment that could be easily incorporated into clinical routine breast MRI exams. KEY POINTS: • The proposed PDFF strongly negatively correlates with visually determined mammographic and MRI-based breast density estimations and therefore allows for an accurate, non-ionizing, and user-independent breast density measurement. • In combination with T2*, the PDFF can be used to track structural alterations in the composition of breast tissue for an individualized risk assessment for breast cancer.


Asunto(s)
Densidad de la Mama , Neoplasias de la Mama , Humanos , Femenino , Protones , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico por imagen , Agua , Tejido Adiposo/diagnóstico por imagen
3.
Ultraschall Med ; 44(5): 520-536, 2023 Oct.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-37072031

RESUMEN

Alongside mammography, breast ultrasound is an important and well-established method in assessment of breast lesions. With the "Best Practice Guideline", the DEGUM Breast Ultrasound (in German, "Mammasonografie") working group, intends to describe the additional and optional application modalities for the diagnostic confirmation of breast findings and to express DEGUM recommendations in this Part II, in addition to the current dignity criteria and assessment categories published in Part I, in order to facilitate the differential diagnosis of ambiguous lesions.The present "Best Practice Guideline" has set itself the goal of meeting the requirements for quality assurance and ensuring quality-controlled performance of breast ultrasound. The most important aspects of quality assurance are explained in this Part II of the Best Practice Guideline.


Asunto(s)
Mamografía , Ultrasonografía Mamaria , Femenino , Humanos , Mamografía/métodos
4.
Gesundheitswesen ; 82(8-09): e108-e121, 2020 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-32858754

RESUMEN

Health services research in oncology deals with all situations which cancer patients face. It looks at the different phases of care, i. e. prevention / early detection, prehabilitation, diagnostics, therapy, rehabilitation and palliative care as well as the various actors, including those affected, the carers and self-help. It deals with healthy people (e. g. in the context of prevention / early detection), patients and cancer survivors. Due to the nature of cancer and the existing care structures, there are a number of specific contents for health services research in oncology compared to general health services research while the methods remain essentially identical. This memorandum describes the subject, illustrates the care structures and identifies areas of health services research in oncology. This memorandum has been prepared by the Oncology Section of the German Network for Health Services Research and is the result of intensive discussions.


Asunto(s)
Investigación sobre Servicios de Salud , Oncología Médica , Medicina , Alemania , Humanos , Cuidados Paliativos
5.
Breast Cancer Res Treat ; 174(2): 279-296, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30506111

RESUMEN

PURPOSE: The second International Consensus Conference on B3 lesions was held in Zurich, Switzerland, in March 2018, organized by the International Breast Ultrasound School to re-evaluate the consensus recommendations. METHODS: This study (1) evaluated how management recommendations of the first Zurich Consensus Conference of 2016 on B3 lesions had influenced daily practice and (2) reviewed current literature towards recommendations to biopsy. RESULTS: In 2018, the consensus recommendations for management of B3 lesions remained almost unchanged: For flat epithelial atypia (FEA), classical lobular neoplasia (LN), papillary lesions (PL) and radial scars (RS) diagnosed on core-needle biopsy (CNB) or vacuum-assisted biopsy (VAB), excision by VAB in preference to open surgery, and for atypical ductal hyperplasia (ADH) and phyllodes tumors (PT) diagnosed at VAB or CNB, first-line open surgical excision (OE) with follow-up surveillance imaging for 5 years. Analyzing the Database of the Swiss Minimally Invasive Breast Biopsies (MIBB) with more than 30,000 procedures recorded, there was a significant increase in recommending more frequent surveillance of LN [65% in 2018 vs. 51% in 2016 (p = 0.004)], FEA (72% in 2018 vs. 62% in 2016 (p = 0.005)), and PL [(76% in 2018 vs. 70% in 2016 (p = 0.04)] diagnosed on VAB. A trend to more frequent surveillance was also noted also for RS [77% in 2018 vs. 67% in 2016 (p = 0.07)]. CONCLUSIONS: Minimally invasive management of B3 lesions (except ADH and PT) with VAB continues to be appropriate as an alternative to first-line OE in most cases, but with more frequent surveillance, especially for LN.


Asunto(s)
Biopsia con Aguja Gruesa/métodos , Neoplasias de la Mama/diagnóstico , Biopsia Guiada por Imagen/métodos , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma Intraductal no Infiltrante/patología , Carcinoma Intraductal no Infiltrante/cirugía , Carcinoma Lobular/patología , Carcinoma Lobular/cirugía , Bases de Datos Factuales , Femenino , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Tumor Filoide/patología , Tumor Filoide/cirugía , Vigilancia de la Población , Guías de Práctica Clínica como Asunto
6.
Breast Cancer Res Treat ; 176(2): 481-482, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31152325

RESUMEN

The article Second International Consensus Conference on lesions of uncertain malignant potential in the breast (B3 lesions), written by Christoph J Rageth, Elizabeth AM O'Flynn, Katja Pinker, Rahel A Kubik-Huch, Alexander Mundinger, Thomas Decker, Christoph Tausch, Florian Dammann, Pascal A. Baltzer, Eva Maria Fallenberg, Maria P Foschini, Sophie Dellas, Michael Knauer, Caroline Malhaire, Martin Sonnenschein, Andreas Boos, Elisabeth Morris, Zsuzsanna Varga, was originally published electronically on the publisher's internet portal (currently SpringerLink) on November 30, 2018 without open access.

7.
Breast Cancer Res Treat ; 146(2): 371-81, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24986697

RESUMEN

The purpose of this study was to compare contrast-enhanced spectral mammography (CESM) with mammography (MG) and combined CESM + MG in terms of detection and size estimation of histologically proven breast cancers in order to assess the potential to reduce radiation exposure. A total of 118 patients underwent MG and CESM and had final histological results. CESM was performed as a bilateral examination starting 2 min after injection of iodinated contrast medium. Three independent blinded radiologists read the CESM, MG, and CESM + MG images with an interval of at least 4 weeks to avoid case memorization. Sensitivity and size measurement correlation and differences were calculated, average glandular dose (AGD) levels were compared, and breast densities were reported. Fisher's exact and Wilcoxon tests were performed. A total of 107 imaging pairs were available for analysis. Densities were ACR1: 2, ACR2: 45, ACR3: 42, and ACR4: 18. Mean AGD was 1.89 mGy for CESM alone, 1.78 mGy for MG, and 3.67 mGy for the combination. In very dense breasts, AGD of CESM was significantly lower than MG. Sensitivity across readers was 77.9 % for MG alone, 94.7 % for CESM, and 95 % for CESM + MG. Average tumor size measurement error compared to postsurgical pathology was -0.6 mm for MG, +0.6 mm for CESM, and +4.5 mm for CESM + MG (p < 0.001 for CESM + MG vs. both modalities). CESM alone has the same sensitivity and better size assessment as CESM + MG and was significantly better than MG with only 6.2 % increase in AGD. The combination of CESM + MG led to systematic size overestimation. When a CESM examination is planned, additional MG can be avoided, with the possibility of saving up to 61 % of radiation dose, especially in patients with dense breasts.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Medios de Contraste , Mamografía , Intensificación de Imagen Radiográfica , Absorciometría de Fotón , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Femenino , Humanos , Mamografía/métodos , Mamografía/normas , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Prospectivos , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Sensibilidad y Especificidad , Carga Tumoral
8.
Acta Radiol ; 55(1): 32-8, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23878356

RESUMEN

BACKGROUND: Volumetric breast composition analysis represents a useful tool for assessing changes in breast composition over time. However, no data exist on the reproducibility of this method in serial mammograms. PURPOSE: To assess the reproducibility of two volumetric breast composition parameters, breast percent density (PD) and fibroglandular tissue volume (FTV), in consecutive mammograms. MATERIAL AND METHODS: Volumetric breast composition analysis to determine PD and FTV was performed in two consecutive unilateral mammograms of 211 patients. All mammograms were obtained on the same digital mammography unit within a maximum interval of 24 months. Volumetric data for analysis for both examinations were available for 174 patients. Thirty-two patients had successful volumetric analysis of additional consecutive examinations on a second digital mammography unit. Inter-examination correlation of measurements and absolute differences were analyzed. Bland-Altman analysis was performed to compare readings from different mammography units. RESULTS: Mean FTV remained constant over the study period. A reduction in PD of 0.5% and a mean increase in breast volume (BV) of 3% were observed. FTV measurements obtained on the same mammography unit were significantly more reproducible than PD measurements (Pearson correlation coefficients of 0.947 and 0.920, respectively; P < 0.05). A 15% difference between mean absolute volume measurements (FTV and BV) obtained on different mammography units was observed (P ≤ 0.001), while mean PD was close to the expected value. CONCLUSION: Volumetric breast composition analysis is highly reproducible in serial mammograms in normal women. FTV is a more reproducible parameter than PD, indicating that absolute quantification of breast parenchyma may be preferable to the measurement of relative parameters such as PD. However, a disadvantage of using FTV is that it is susceptible to systematic differences when measurements are obtained on different imaging platforms.


Asunto(s)
Anatomía Transversal/métodos , Mama/patología , Tejido Conectivo/diagnóstico por imagen , Adulto , Anciano , Tejido Conectivo/patología , Femenino , Humanos , Mamografía , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Factores de Tiempo
9.
Rofo ; 2024 Jun 21.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-38906159

RESUMEN

Axillary lymphadenopathy (LA) after COVID-19 vaccination is now known to be a common side effect. In these cases, malignancy cannot always be excluded on the basis of morphological imaging criteria.Narrative review for decision-making regarding control and follow-up intervals for axillary LA according to currently published research. This article provides a practical overview of the management of vaccine-associated LA using image examples and a flowchart and provides recommendations for follow-up intervals. A particular focus is on patients presenting for diagnostic breast imaging. The diagnostic criteria for pathological lymph nodes (LN) are explained.Axillary LA is a common adverse effect after COVID-19 vaccination (0.3-53%). The average duration of LA is more than 100 days. LA is also known to occur after other vaccinations, such as the seasonal influenza vaccine. Systematic studies on this topic are missing. Other causes of LA after vaccination (infections, autoimmune diseases, malignancies) should be considered for the differential diagnosis. If the LA persists for more than 3 months after COVID-19 vaccination, a primarily sonographic follow-up examination is recommended after another 3 months. A minimally invasive biopsy of the LA is recommended if a clinically suspicious LN persists or progresses. In the case of histologically confirmed breast cancer, a core biopsy without a follow-up interval is recommended regardless of the vaccination, as treatment appropriate to the stage should not be influenced by follow-up intervals. For follow-up after breast cancer, the procedure depends on the duration of the LA and the woman's individual risk of recurrence.Vaccination history should be well documented and taken into account when evaluating suspicious LN. Biopsy of abnormal, persistent, or progressive LNs is recommended. Preoperative staging of breast cancer should not be delayed by follow-up. The risk of false-positive findings is accepted, and the suspicious LNs are histologically examined in a minimally invasive procedure. · The vaccination history must be documented (vaccine, date, place of application).. · If axillary LA persists for more than 3 months after vaccination, a sonographic follow-up examination is recommended after 3 months.. · Enlarged LNs that are persistent, progressive in size, or are suspicious on control sonography should be biopsied.. · Suspicious LNs should be clarified before starting oncological therapy, irrespective of the vaccination status, according to the guidelines and without delaying therapy.. · Wilpert C, Wenkel E, Baltzer PA et al. Vaccine-associated axillary lymphadenopathy with a focus on COVID-19 vaccines. Fortschr Röntgenstr 2024; DOI 10.1055/a-2328-7536.

10.
Rofo ; 2024 Jan 18.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-38237631

RESUMEN

· Breast MRI is an essential part of breast imaging. · The recommendations for performing breast MRI have been updated. · A table provides a compact and quick overview. More detailed comments supplement the table.. · The "classic" breast MRI can be performed based on the recommendations. Tips for special clinical questions, such as implant rupture, mammary duct pathology or local lymph node status, are included.. ZITIERWEISE: · Wenkel E, Wunderlich P, Fallenberg E et al. Aktualisierung der Empfehlungen der AG Mammadiagnostik der Deutschen Röntgengesellschaft zur Durchführung der Mamma-MRT. Fortschr Röntgenstr 2024; DOI: 10.1055/a-2216-0782.

11.
Breast Care (Basel) ; 19(2): 87-94, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38765898

RESUMEN

Introduction: Pre-therapeutic histologic diagnosis through image-guided core needle biopsy (CNB) or vacuum-assisted biopsy (VAB) for suspicious breast findings is a standard procedure. Despite the moderate risk of bleeding, a significant proportion of patients are on temporary or permanent anti-coagulation therapy (ACT) or anti-platelet therapy (APT). Currently, there are no established guidelines for managing biopsies in such patients, leading to varying approaches in clinical practice. Methods: An online survey was conducted among all members of the breast ultrasound working group at the German Society for Ultrasound in Medicine (DEGUM) and the working group for breast diagnostics at the German Radiology Society (DRG). It included n = 51 questions about individual risk perception of biopsy-related bleeding complications and the specific management of biopsies on ACT/APT. Results: A total of 332 experts participated, with 51.8% reporting the absence of a standardized management plan for breast biopsies on ACT/APT. Concerning specific ACT/APT medications, the survey revealed discrepancies in risk perception and management: The majority preferred discontinuing medication with directly acting oral anti-coagulants (DOACs; CNB: 66.9%; VAB: 91.1%), phenprocoumon (CNB: 74.9%; VAB: 96.7%), or therapeutic heparin (CNB: 46.1%; VAB: 72.7%). However, there was a lower inclination to discontinue acetylsalicylic acid (ASA; CNB: 15.2%; VAB: 50.3%) or prophylactic heparin (CNB: 11.9%, VAB: 36.3%). Conclusion: Breast biopsies for patients on ASA or prophylactic heparin are deemed safe and part of standard clinical practice. However, despite available feasibility studies, conducting breast biopsies on ACT medications such as DOACs or phenprocoumon appears feasible only for a minority of experts.

13.
Insights Imaging ; 15(1): 124, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38825600

RESUMEN

OBJECTIVES: Achieving a consensus on a definition for different aspects of radiomics workflows to support their translation into clinical usage. Furthermore, to assess the perspective of experts on important challenges for a successful clinical workflow implementation. MATERIALS AND METHODS: The consensus was achieved by a multi-stage process. Stage 1 comprised a definition screening, a retrospective analysis with semantic mapping of terms found in 22 workflow definitions, and the compilation of an initial baseline definition. Stages 2 and 3 consisted of a Delphi process with over 45 experts hailing from sites participating in the German Research Foundation (DFG) Priority Program 2177. Stage 2 aimed to achieve a broad consensus for a definition proposal, while stage 3 identified the importance of translational challenges. RESULTS: Workflow definitions from 22 publications (published 2012-2020) were analyzed. Sixty-nine definition terms were extracted, mapped, and semantic ambiguities (e.g., homonymous and synonymous terms) were identified and resolved. The consensus definition was developed via a Delphi process. The final definition comprising seven phases and 37 aspects reached a high overall consensus (> 89% of experts "agree" or "strongly agree"). Two aspects reached no strong consensus. In addition, the Delphi process identified and characterized from the participating experts' perspective the ten most important challenges in radiomics workflows. CONCLUSION: To overcome semantic inconsistencies between existing definitions and offer a well-defined, broad, referenceable terminology, a consensus workflow definition for radiomics-based setups and a terms mapping to existing literature was compiled. Moreover, the most relevant challenges towards clinical application were characterized. CRITICAL RELEVANCE STATEMENT: Lack of standardization represents one major obstacle to successful clinical translation of radiomics. Here, we report a consensus workflow definition on different aspects of radiomics studies and highlight important challenges to advance the clinical adoption of radiomics. KEY POINTS: Published radiomics workflow terminologies are inconsistent, hindering standardization and translation. A consensus radiomics workflow definition proposal with high agreement was developed. Publicly available result resources for further exploitation by the scientific community.

14.
Radiologie (Heidelb) ; 63(12): 916-924, 2023 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-37889284

RESUMEN

BACKGROUND: Contrast-enhanced mammography (CEM) is an imaging method that is able to improve visualization of intramammary tumors after peripheral venous administration of an iodine-containing contrast medium (ICM). OBJECTIVES AND METHODS: The current significance of CEM is discussed. RESULTS: Studies were able to show an advantage of CEM in the diagnosis of breast cancer compared to mammography, especially for women with dense breasts. Indications for CEM currently depend on the availability of magnetic resonance imaging (MRI). If MRI is available, CEM is indicated in those cases when MRI cannot be performed. Use of CEM for breast cancer screening is currently viewed critically. This view can change when results and updated assessments of large CEM studies in Europe and USA become available. Patients must be informed about the use of an ICM. As ICM administration for CEM is carried out in a similar manner to established imaging methods, the authors expect the use of ICM for CEM to be unproblematic as long as general contraindications are adhered to. CONCLUSIONS: In the future, CEM could have greater importance for the diagnosis of breast cancer, as this imaging method has diagnostic advantages compared to conventional mammography. A great advantage of CEM is its availability. For those who use breast MRI, CEM is helpful when MRI is not feasible due to contraindications or other reasons.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Mamografía/métodos , Mama/diagnóstico por imagen , Mama/patología , Medios de Contraste , Predicción
15.
Virchows Arch ; 483(1): 5-20, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37330436

RESUMEN

The heterogeneous group of B3 lesions in the breast harbors lesions with different malignant potential and progression risk. As several studies about B3 lesions have been published since the last Consensus in 2018, the 3rd International Consensus Conference discussed the six most relevant B3 lesions (atypical ductal hyperplasia (ADH), flat epithelial atypia (FEA), classical lobular neoplasia (LN), radial scar (RS), papillary lesions (PL) without atypia, and phyllodes tumors (PT)) and made recommendations for diagnostic and therapeutic approaches. Following a presentation of current data of each B3 lesion, the international and interdisciplinary panel of 33 specialists and key opinion leaders voted on the recommendations for further management after core-needle biopsy (CNB) and vacuum-assisted biopsy (VAB). In case of B3 lesion diagnosis on CNB, OE was recommended in ADH and PT, whereas in the other B3 lesions, vacuum-assisted excision was considered an equivalent alternative to OE. In ADH, most panelists (76%) recommended an open excision (OE) after diagnosis on VAB, whereas observation after a complete VAB-removal on imaging was accepted by 34%. In LN, the majority of the panel (90%) preferred observation following complete VAB-removal. Results were similar in RS (82%), PL (100%), and FEA (100%). In benign PT, a slim majority (55%) also recommended an observation after a complete VAB-removal. VAB with subsequent active surveillance can replace an open surgical intervention for most B3 lesions (RS, FEA, PL, PT, and LN). Compared to previous recommendations, there is an increasing trend to a de-escalating strategy in classical LN. Due to the higher risk of upgrade into malignancy, OE remains the preferred approach after the diagnosis of ADH.


Asunto(s)
Neoplasias de la Mama , Carcinoma Intraductal no Infiltrante , Tumor Filoide , Lesiones Precancerosas , Humanos , Femenino , Mama/patología , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Carcinoma Intraductal no Infiltrante/patología , Mamografía/métodos , Biopsia con Aguja Gruesa , Lesiones Precancerosas/diagnóstico , Lesiones Precancerosas/patología , Tumor Filoide/patología , Estudios Retrospectivos
17.
Breast Care (Basel) ; 18(4): 289-305, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37900552

RESUMEN

Background: Each year the interdisciplinary Arbeitsgemeinschaft Gynäkologische Onkologie (AGO), German Gynecological Oncology Group Breast Committee on Diagnosis and Treatment of Breast Cancer provides updated state-of-the-art recommendations for early and metastatic breast cancer. Summary: The updated evidence-based treatment recommendation for early and metastatic breast cancer has been released in March 2023. Key Messages: This paper concisely captures the updated recommendations for early breast cancer chapter by chapter.

18.
Photoacoustics ; 26: 100343, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35308306

RESUMEN

Background: Since the initial breast transillumination almost a century ago, breast cancer imaging using light has been considered in different implementations aiming to improve diagnostics, minimize the number of available biopsies, or monitor treatment. However, due to strong photon scattering, conventional optical imaging yields low resolution images, challenging quantification and interpretation. Optoacoustic imaging addresses the scattering limitation and yields high-resolution visualization of optical contrast, offering great potential value for breast cancer imaging. Nevertheless, the image quality of experimental systems remains limited due to a number of factors, including signal attenuation with depth and partial view angle and motion effects, particularly in multi-wavelength measurements. Methods: We developed data analytics methods to improve the accuracy of handheld optoacoustic breast cancer imaging, yielding second-generation optoacoustic imaging performance operating in tandem with ultrasonography. Results: We produced the most advanced images yet with handheld optoacoustic examinations of the human breast and breast cancer, in terms of resolution and contrast. Using these advances, we examined optoacoustic markers of malignancy, including vasculature abnormalities, hypoxia, and inflammation, on images obtained from breast cancer patients. Conclusions: We achieved a new level of quality for optoacoustic images from a handheld examination of the human breast, advancing the diagnostic and theranostic potential of the hybrid optoacoustic-ultrasound (OPUS) examination over routine ultrasonography.

20.
Breast Care (Basel) ; 17(4): 403-420, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36156915

RESUMEN

Introduction: The AGO (Arbeitsgemeinschaft Gynäkologische Onkologie, German Gynecological Oncology Group) Task Force on Diagnosis and Treatment of Breast Cancer as an interdisciplinary team consists of specialists from gynecological oncology, pathology, diagnostic radiology, medical oncology, and radiation oncology with a special focus on breast cancer. Methods: The updated evidence-based treatment recommendation 2022 for early breast cancer (EBC) and metastatic breast cancer of the AGO Task Force has been released. Results and Conclusion: This paper captures the update of EBC.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA