Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Strahlenther Onkol ; 199(11): 1018-1024, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37698592

RESUMEN

BACKGROUND: Electroanatomical mapping (EAM)-guided stereotactic arrhythmia radioablation (STAR) is a novel noninvasive therapy option for patients with monomorphic ventricular tachycardia (VT) refractory to antiarrhythmic drugs and/or urgent catheter ablation (CA). Data on success rates in an emergency situation such as electrical storm (ES) are rare. We present a case of a patient with an initially very poor life expectancy after extensive myocardial infarction with therapy-resistant ES, not amendable for further antiarrhythmic drug therapy, implantable cardioverter-defibrillator implantation, or repeated CA who was introduced to the radiation oncology department for emergency STAR as a bail-out therapy. METHODS: Target volume definition and transfer from EAM to CT were validated and quality assured with a semi-automatic, dedicated visualization tool (CARDIO-RT). Emergency STAR was performed with 25 Gy in the framework of the RAVENTA study. The VT burden gradually decreased after STAR; however, a second VT morphology occurred, which was successfully treated with EAM-guided CA 12 days after STAR. RESULTS: The second EAM-guided CA showed areas of low voltage in the irradiated segments, indicating a precise targeting and early functional response to STAR. The patient remained free of any VT recurrence or any radiation-related toxicities and in good general condition during the recent follow-up of 18 months. CONCLUSION: The case highlights the possible approach, caveats, difficulties, and prognosis of a patient severely affected by therapy-resistant VT in whom CA could not lead to VT suppression. Further studies of putative mechanisms of STAR in the acute and chronic phase of this novel therapy are warranted.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirugía , Antiarrítmicos/uso terapéutico , Corazón , Ablación por Catéter/efectos adversos , Pronóstico , Resultado del Tratamiento
2.
Radiother Oncol ; 200: 110499, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39242029

RESUMEN

BACKGROUND: Stereotactic arrhythmia radioablation (STAR) is a therapeutic option for ventricular tachycardia (VT) where catheter-based ablation is not feasible or has previously failed. Target definition and its transfer from electro-anatomic maps (EAM) to radiotherapy treatment planning systems (TPS) is challenging and operator-dependent. Software solutions have been developed to register EAM with cardiac CT and semi-automatically transfer 2D target surface data into 3D CT volume coordinates. Results of a cross-validation study of two conceptually different software solutions using data from the RAVENTA trial (NCT03867747) are reported. METHODS: Clinical Target Volumes (CTVs) were created from target regions delineated on EAM using two conceptually different approaches by separate investigators on data of 10 patients, blinded to each other's results. Targets were transferred using 3D-3D registration and 2D-3D registration, respectively. The resulting CTVs were compared in a core-lab using two complementary analysis software packages for structure similarity and geometric characteristics. RESULTS: Volumes and surface areas of the CTVs created by both methods were comparable: 14.88 ± 11.72 ml versus 15.15 ± 11.35 ml and 44.29 ± 33.63 cm2 versus 46.43 ± 35.13 cm2. The Dice-coefficient was 0.84 ± 0.04; median surface-distance and Hausdorff-distance were 0.53 ± 0.37 mm and 6.91 ± 2.26 mm, respectively. The 3D-center-of-mass difference was 3.62 ± 0.99 mm. Geometrical volume similarity was 0.94 ± 0.05 %. CONCLUSION: The STAR targets transferred from EAM to TPS using both software solutions resulted in nearly identical 3D structures. Both solutions can be used for QA (quality assurance) and EAM-to-TPS transfer of STAR-targets. Semi-automated methods could potentially help to avoid mistargeting in STAR and offer standardized workflows for methodically harmonized treatments.


Asunto(s)
Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiocirugia/métodos , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/diagnóstico por imagen , Programas Informáticos , Tomografía Computarizada por Rayos X , Imagenología Tridimensional , Masculino , Femenino , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA