Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 100 Suppl 1: S25-S35, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36661369

RESUMEN

BACKGROUND: Uncovered struts are a determinant of stent failure. The impact of plaque composition and procedural factors on the occurrence, evolution, and outcomes of uncovered struts in a high-risk setting has not been investigated. OBJECTIVE: To investigate the determinants and long-term clinical impact of largely uncovered struts (LUS) in thin-struts drug-eluting stents (DES) implanted in complex lesions by intracoronary optical coherence tomography (OCT). METHODS: Ninety patients with multivessel disease undergoing staged complete revascularization were randomly assigned to bioabsorbable or durable polymer DES. OCT were serially performed during the index procedure, at 3- and 18-month follow-up, and analyzed by an independent core lab. Struts were defined uncovered by OCT if no tissue was visible above the struts. LUS were defined as ≥30% of uncovered struts at 3-month follow-up. Clinical outcomes were the occurrence of target vessel failure (TVF) and major adverse cardiac and cerebrovascular events (MACCE) at 5-year follow-up. RESULTS: LUS occurred in 31 patients (34.4%) regardless of stent platform. At 5 years, no differences were observed in the rate of TVF (12.7% vs. 13.4%; p = 0.91) and MACCE (23.9% vs. 24.9%; p = 0.88) between the two groups. At multivariate logistic regression, plaque rupture, mean lumen diameter, proximal reference vessel area, and maximum stent deployment pressure were independent predictors of LUS. CONCLUSIONS: LUS are a frequent finding in complex coronary lesions treated with thin-struts DES, especially in the presence of plaque rupture. However, in this study, no significant safety signal related to LUS emerged in long-term follow-up.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Placa Aterosclerótica , Humanos , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento , Diseño de Prótesis , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos
2.
Circ J ; 85(10): 1701-1707, 2021 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-33658444

RESUMEN

BACKGROUND: Coronavirus Disease-2019 (COVID-19) may impair outcomes of patients with ST-segment elevation myocardial infarction (STEMI). The extent of this phenomenon and its mechanisms are unclear.Methods and Results:This study prospectively included 50 consecutive STEMI patients admitted to our center for primary percutaneous coronary intervention (PCI) at the peak of the Italian COVID-19 outbreak. At admission, a COVID-19 test was positive in 24 patients (48%), negative in 26 (52%). The primary endpoint was in-hospital all-cause mortality. Upon admission, COVID-19 subjects had lower PO2/FiO2 (169 [100-425] vs. 390 [302-477], P<0.01), more need for oxygen support (62.5% vs. 26.9%, P=0.02) and a higher rate of myocardial dysfunction (ejection fraction <30% in 45.8% vs. 19.2%, P=0.04). All patients underwent emergency angiography. In 12.5% of COVID-19 patients, no culprit lesions were detected, thus PCI was performed in 87.5% and 100% of COVID-19 positive and negative patients, respectively (P=0.10). Despite a higher rate of obstinate thrombosis in the COVID-19 group (47.6% vs. 11.5%, P<0.01), the PCI result was similar (TIMI 2-3 in 90.5% vs. 100%, P=0.19). In-hospital mortality was 41.7% and 3.8% in COVID-19 positive and negative patients, respectively (P<0.01). Respiratory failure was the leading cause of death (80%) in the COVID-19 group, frequently associated with severe myocardial dysfunction. CONCLUSIONS: In-hospital mortality of COVID-19 patients with STEMI remains high despite successful PCI, mainly due to coexisting severe respiratory failure. This may be a critical factor in patient management and treatment selection.


Asunto(s)
COVID-19/fisiopatología , Pulmón/fisiopatología , Intervención Coronaria Percutánea , Respiración , Insuficiencia Respiratoria/fisiopatología , Infarto del Miocardio con Elevación del ST/terapia , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , COVID-19/mortalidad , COVID-19/virología , Causas de Muerte , Femenino , Mortalidad Hospitalaria , Humanos , Pulmón/virología , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Insuficiencia Respiratoria/diagnóstico , Insuficiencia Respiratoria/mortalidad , Insuficiencia Respiratoria/virología , Medición de Riesgo , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/mortalidad , Infarto del Miocardio con Elevación del ST/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 93(1): E56-E62, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30244510

RESUMEN

BACKGROUND: Iatrogenic hemorrhagic pericardial tamponade (IHPT) represents a life-threating condition requiring emergency pericardiocentesis. In this clinical context, reinfusion of pericardial blood can stabilize the patient and sustain hemodynamic conditions. AIMS AND METHODS: We reviewed all cases of IHPT occurred at our hospital over a 10 years span. In all patient autologous blood reinfusion through a femoral vein was performed. RESULTS: In our clinical experience of 30 consecutive patients with hemorrhagic cardiac tamponade, this technique was successful to limit blood transfusions, to prevent further clinical worsening and bridge patients with intractable bleeding, to cardiac surgery. No major adverse reactions were directly related to blood autotransfusion. CONCLUSION: In the complex clinical scenario of acute tamponade occurring during catheter-based cardiac procedures, autotransfusion of pericardial blood through a femoral vein is safe and effective. It can be a useful trick up the sleeve of the interventional cardiologist.


Asunto(s)
Transfusión de Sangre Autóloga , Cateterismo Cardíaco/efectos adversos , Taponamiento Cardíaco/terapia , Vena Femoral , Hemorragia/terapia , Enfermedad Iatrogénica , Pericardiocentesis , Anciano , Anciano de 80 o más Años , Transfusión de Sangre Autóloga/efectos adversos , Taponamiento Cardíaco/diagnóstico por imagen , Taponamiento Cardíaco/etiología , Estudios de Factibilidad , Femenino , Hemorragia/diagnóstico por imagen , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Pericardiocentesis/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
4.
Eur Heart J ; 39(26): 2448-2456, 2018 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-29788263

RESUMEN

Aims: Delayed healing and endothelial dysfunction may occur with drug-eluting stents (DES), promoting accelerated infiltration of lipids in the neointima and development of neoatherosclerosis (NA). Pathology data suggest durable polymer (DP) of DES to play a major role in this process. Whether biodegradable polymer (BP) may address these issues is uncertain. We compared in vivo vessel healing and NA of current generation BP- or DP-DES using serial optical coherence tomography (OCT) assessments. Methods and results: Ninety patients with multivessel coronary artery disease were randomized 1:1 to BP everolimus-eluting stents (EES, Synergy) or DP zotarolimus-eluting stents (ZES, Resolute Integrity). Co-primary endpoints were the maximum length of uncovered struts at 3 months (powered for non-inferiority) and the percentage of patients presenting with frames of NA at 18 months (powered for superiority) as measured by OCT. The maximum length of uncovered struts at 3 months was 10 ± 8 mm in the BP-EES group and 11 ± 7 mm in the DP-ZES group (mean difference -1 mm; upper 97.5% confidence interval +2 mm; P = 0.05 for non-inferiority; P = 0.45 for superiority). The percentage of patients presenting with frames of NA at 18 months was low and similar between BP-EES and DP-ZES groups (11.6% vs. 15.9%; P = 0.56). There was no stent thrombosis in both groups at 24 months. Conclusion: BP-EES and DP-ZES showed a similar healing response at 3 months and a low incidence of NA at 18 months. Biocompatible polymers, regardless of whether they are durable or biodegradable, may favourably impact the long-term vascular response to current-generation DES.


Asunto(s)
Implantes Absorbibles , Aterosclerosis/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Neointima/diagnóstico por imagen , Intervención Coronaria Percutánea , Anciano , Materiales Biocompatibles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Everolimus/administración & dosificación , Femenino , Humanos , Inmunosupresores/administración & dosificación , Masculino , Persona de Mediana Edad , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Factores de Tiempo , Tomografía de Coherencia Óptica , Cicatrización de Heridas
6.
J Invasive Cardiol ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38598251

RESUMEN

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.

7.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38742523

RESUMEN

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Masculino , Femenino , Anciano , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Italia/epidemiología , Anciano de 80 o más Años , Readmisión del Paciente/estadística & datos numéricos , Insuficiencia del Tratamiento , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía
8.
Catheter Cardiovasc Interv ; 81(3): 510-8, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22431208

RESUMEN

BACKGROUND: New generation drug-eluting stents (DES) incorporate thinner struts and novel alloys to improve clinical performance. Nevertheless, the impact of novel stent materials and designs on human vascular response to DES remains elusive. We sought to evaluate the in-vivo coronary artery response to platinum-chromium (PtCr) versus cobalt-chromium (CoCr) stents featuring the same durable polymer and antiproliferative drug by optical coherence tomography (OCT). METHODS AND RESULTS: A total of 42 patients with de novo lesions in native coronary vessels was treated with PtCr-everolimus eluting stent (EES; n = 21) or CoCr-EES (n = 21). Angiography, intravascular ultrasound, and OCT were performed at the index procedure and 6-month follow-up. PtCr-EES and CoCr-EES had similar concentric expansion (stent eccentricity index; median 0.91 vs. 0.90, respectively, P = 0.47) and very low rate of strut malapposition (median 1.15 vs. 1.80%, P = 0.92) at post implantation. Proportion of struts embedded in tissue was lower in PtCr-EES compared to CoCr-EES (median 2.67 vs. 15.23%, P < 0.001). The primary prespecified end point, the percentage of uncovered struts per patient at 6 months follow-up, was 8.46% [interquartile range (IQR) = 3.05-17.26] in PtCr-EES and 5.88% (IQR = 1.35-13.27) in CoCr-EES (P = 0.36), whereas malapposed struts were observed in 0.00% (IQR = 0.00-0.25) versus 0.48% (IQR = 0.00-1.44), respectively, (P = 0.10). Strut-level neointimal thickness did not differ between the two platforms (median 0.09 vs. 0.08 mm, P = 0.49). CONCLUSIONS: Acute and mid-term responses to EES using PtCr or CoCr platforms were similar, with concentric stent expansion, low malapposition, similar strut coverage and limited amount of neointima. Conversely, at postprocedure, PtCr-EES had fewer embedded struts compared with CoCr-EES.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/patología , Stents Liberadores de Fármacos , Revascularización Miocárdica/instrumentación , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica/métodos , Anciano , Antineoplásicos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Everolimus , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sirolimus/farmacología , Ultrasonografía Intervencional
9.
Panminerva Med ; 65(4): 443-453, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37259492

RESUMEN

BACKGROUND: The clinical impact of coronary artery disease (CAD) on the prognosis of patients undergoing MitraClip implantation is still unclear. METHODS: One thousand nine hundred fifty-three patients undergoing MitraClip implantation included in the multicenter GIOTTO Registry were stratified according to CAD. Endpoints were all-cause death, cardiac death, and re-hospitalization for heart failure at follow-up (median 15.8 months). RESULTS: Although younger, CAD patients were more symptomatic, had worse cardiovascular risk profile, higher burden of comorbidities, more frequently affected by functional MR, with higher left ventricle (LV) diameters and lower ejection fraction (EF). At follow-up, CAD patients showed higher rates of all-cause death (25.4% vs. 19.6%; P=0.002), cardiovascular death (14.0% vs. 10.1%; P=0.007) and re-hospitalization for heart failure (13.9% vs. 10.2%; P=0.011). Dividing the population according to mitral regurgitation (MR) etiology (functional vs. non-functional MR), no differences were observed between CAD and no-CAD patients. At multivariate logistic regression, NYHA III/IV class, prior heart failure hospitalization, severe chronic kidney disease, atrial fibrillation, LV end-diastolic diameter and LVEF<30% but not CAD resulted independent predictors of all-cause death. The same finding was confirmed even after propensity score adjustment. CONCLUSIONS: CAD did not show a relevant impact on mid-term prognosis per se, but seemed to identify a more complex and diseased cohort of patients with worse clinical and functional status.


Asunto(s)
Enfermedad de la Arteria Coronaria , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Insuficiencia Cardíaca/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Resultado del Tratamiento
10.
Int J Cardiol Heart Vasc ; 42: 101092, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35873861

RESUMEN

Background: Dual antiplatelet therapy (DAPT) with aspirin and a P2Y12 receptor antagonist is the cornerstone of therapy in patients with acute coronary syndrome (ACS). Adherence to medical therapy is an important issue, as premature DAPT discontinuation increases the risk of new ischemic events. The aim of the present observational prospective multicenter study was to evaluate in the real-world incidence and discontinuation patterns of ticagrelor during the first 12 months after ACS. Methods: We analyzed 431 ACS patients, discharged with ticagrelor, by 7 Italian centers. The primary end-point was the incidence of cessation of ticagrelor up to 12 months from the index event. Results: Definitive ticagrelor cessations occurred in 52 patients (12.1%), of which 35 were discontinuations (clinically driven) and 17 disruptions (due to acute events). Temporary cessation occurred in 14 cases (3.3%). Age ≥ 80 years and anticoagulant therapy were independent predictors of premature discontinuation. Bleeding occurred in 74 patients, of which 25 suffered a BARC ≥ 2 bleeding event. Bleeding were more frequent in female sex (27.0% vs 17.2%, p-value 0.049) and in patients with a history of bleeding (8.1% vs 2.9%, p-value 0.035). Conclusions: Our study found that the adherence to DAPT with ticagrelor after an ACS is still an important issue, premature discontinuation occurred mainly in fragile patients, like elderly, who suffered a previous bleeding or underwent previous percutaneous coronary intervention.

11.
Panminerva Med ; 64(1): 1-8, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34309332

RESUMEN

BACKGROUND: Transcatheter mitral valve repair (TMVR) with MitraClip™ (Abbott Laboratories; Abbott Park, IL, USA) is an established treatment for mitral regurgitation (MR). More than one MitraClip™ may be implanted if a single one does not reduce MR adequately. We aimed to appraise the outlook of patients undergoing implantation of one, two or multiple MitraClip™ for TMVR. METHODS: Exploiting the ongoing prospective GISE Registry of Transcatheter Treatment of Mitral Valve Regurgitation (GIOTTO) Study dataset, we compared patients, procedural details and outcomes distinguishing those receiving one, two or multiple MitraClip™. The primary endpoint was the composite of 1-year cardiac death or rehospitalization for heart failure. Additional endpoints included all cause death, surgical mitral repair, and functional class. Multivariable adjusted Cox proportional hazard analysis was used for confirmatory purposes. RESULTS: As many as 1824 patients were included: 718 (39.4%) treated with a single MitraClip™, and 940 (51.5%) receiving two MitraClip™, and 166 (9.1%) receiving three or more. Significant differences were found for baseline features, including age, female gender, diabetes mellitus, hypertension, chronic obstructive pulmonary disease, prior myocardial infarction, atrial fibrillation, permanent pacemaker, cardiac resynchronization therapy, implantable cardioverter defibrillator, and prior mitral valve repair (all P<0.05). Several imaging features were also different, including left ventricular dimensions, MR severity and proportionality, mitral valve area, flail leaflet, and pulmonary vein flow (all P<0.05). Among procedural features, significant differences were found for anesthesia type, MitraClip™ type, fluoroscopy, device, and operating room times, postprocedural mitral gradient, residual MR, smoke-like effect, device success partial detachment and surgical conversion (all P<0.05). In-hospital death occurred more frequently in patients receiving multiple MitraClip™, and the same applied severe residual MR (all P<0.05). Mid-term follow-up (15±13 months) showed significant differences in the risk of death, cardiac death, rehospitalization for heart failure, and their composites, mainly, but not solely, associated with multiple MitraClip™ (all P<0.05). Adjusted analysis confirmed the significantly increased risk of composite adverse events when comparing the multiple vs. single MitraClip™ groups (P=0.014 for death and rehospitalization, P=0.013 for cardiac death or rehospitalization). CONCLUSIONS: Implantation of one or two MitraClip™ is associated with favorable clinical outcomes. Conversely, bail-out implantation of three or more MitraClip™ may portend a worse long-term prognosis.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Mortalidad Hospitalaria , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
12.
Int J Cardiol ; 342: 65-71, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34375704

RESUMEN

BACKGROUND: We aimed at appraising features and outcomes of patients undergoing MitraClip treatment according to their age. METHODS: We queried the prospective GIse registry Of Transcatheter treatment of mitral valve regurgitaTiOn (GIOTTO) multicenter registry dataset including 19 Italian centers performing MitraClip implantation, distinguishing patients <80 vs ≥80 years of age. RESULTS: In total, 1853 patients were included, 751 (40.5%) octogenarians and 1102 (59.5%) non-octogenarians. Several baseline and procedural features were significantly different, including gender, regurgitation etiology, and functional class (all p < 0.05). In-hospital outcomes were similarly satisfactory, with death occurring in 18 (2.4%) and 32 (2.9%, p = 0.561), respectively, and improvement in mitral regurgitation in 732 (97.4%) and 1078 (97.8%, p = 0.746), respectively. After a mean follow-up of 15 months, death occurred in 152 (20.2%) and 264 (24.0%), and cardiac death in 85 (11.3%) and 138 (12.5%), respectively (both p > 0.05). Rehospitalization for heart failure and the composite of cardiac death or rehospitalization for heart failure were significantly less common in octogenarians: 63 (8.4%) vs 156 (14.2%, p < 0.001), and 125 (16.6%) vs 242 (22.0%, p = 0.005), respectively. Multivariable analysis showed that these differences were largely due to confounding features, as after adjustment for baseline, clinical and imaging characteristics no significant difference was found for the above clinical endpoints. CONCLUSIONS: Transcatheter mitral valve repair with the MitraClip in carefully selected octogenarians appears feasible and safe, and is associated with favorable clinical outcomes at mid-term follow-up.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano de 80 o más Años , Cateterismo Cardíaco , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Sistema de Registros , Resultado del Tratamiento
14.
G Ital Cardiol (Rome) ; 21(2): 111-118, 2020 Feb.
Artículo en Italiano | MEDLINE | ID: mdl-32051634

RESUMEN

Clinical guidelines, while representing an objective reference to perform correct therapeutic choices, contain grey zones, where recommendations are not supported by solid evidence. In a conference held in Bergamo in October 2018, an attempt was made to highlight some of the main grey zones in Cardiology and, through a comparison between experts, to draw shared conclusions that can illuminate our clinical practice. This manuscript contains the statements of the symposium concerning the controversies in the percutaneous treatment of valvulopathies. The first topic concerns the durability of aortic bioprostheses, comparing percutaneous interventional with surgical experiences. The second issue examines the opportunity to extend percutaneous aortic replacement as standard care to low-risk patients. The last gap in evidence concerns the percutaneous treatment of functional mitral valve insufficiency, with the MitraClip system. The work has also been implemented with evidences deriving from important randomized studies published after the date of the Conference.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Cardiología/métodos , Enfermedades de las Válvulas Cardíacas/terapia , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/terapia , Guías de Práctica Clínica como Asunto , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto
15.
J Invasive Cardiol ; 30(6): 218-223, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29543187

RESUMEN

BACKGROUND: Distal transradial access in the anatomical snuffbox has advantages over standard access in terms of patient and operator comfort levels and risk of ischemia. Radial artery preservation could be a relevant issue in patients requiring multiple radial artery procedures and coronary bypass with the use of a radial graft. One relevant drawback is the challenging puncture of a small and weak artery, with a steeper learning curve. AIM: The study was aimed at proving feasibility and safety of right and left transradial access in the anatomical snuffbox. METHODS: All 52 consecutive patients assigned to only one operator program underwent diagnostic or procedural intervention through distal transradial access in the anatomical snuffbox. RESULTS: The overall feasibility was 90%, greater than expected in our early clinical experience, with 47 successful accesses out of 52 patients. Failures were due to proximal radial artery occlusion and hypoplastic/vasospastic distal radial artery. CONCLUSION: Distal transradial access in the anatomical snuffbox is an appealing and feasible option for both patients and operators. Further studies are needed to evaluate the clinical benefits conferred by this approach.


Asunto(s)
Cateterismo Cardíaco/métodos , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Arteria Radial/cirugía , Anciano , Cateterismo Cardíaco/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos
16.
J Invasive Cardiol ; 30(6): E48-E49, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29799428

RESUMEN

Percutaneous aortic balloon valvuloplasty as a bridge-to-decision strategy was performed in an 89-year-old woman with multiple comorbidities and cachexia. The patient did well; after 2 weeks, she was discharged home and referred for possible TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/métodos , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Aortografía/métodos , Femenino , Humanos , Arteria Radial/cirugía
18.
Cardiovasc Revasc Med ; 17(5): 339-43, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27053437

RESUMEN

Despite remarkable advances in the interventional landscape, device delivery during percutaneous coronary intervention (PCI) can still present technical challenges especially when performed in complex anatomical settings and through radial approach. To overcome difficult coronary stent delivery, several strategies have been developed. A niche option in such complex cases is the anchoring balloon technique, which involves inflation of a balloon non-coaxially in a side branch or distally to the target lesion in a coaxial fashion, to facilitate stent delivery. However, the main limitation of this technique is the requirement of a large guide catheter (≥7French) which may preclude the use of radial approach. We describe, step-by-step, the distal anchoring ballooning technique performed by a 6Fr radial approach to overcome the stent delivery failure in complex anatomical scenarios and to safely and successfully carry out the PCI procedures.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Enfermedad de la Arteria Coronaria/terapia , Arteria Radial , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Cateterismo Periférico/instrumentación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos , Humanos , Masculino , Punciones , Arteria Radial/diagnóstico por imagen , Resultado del Tratamiento
19.
J Interv Card Electrophysiol ; 12(1): 45-54, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15717151

RESUMEN

BACKGROUND: Cardiac cryoablation has been used to successfully treat a variety of arrhythmias. OBJECTIVE: This study documents our experience with a new 9 French (FR) 8 mm cryocatheter for ablation treatment of symptomatic atrial flutter. METHODS: A total of 77 consecutive patients with symptomatic atrial flutter were treated. Electrophysiological studies (EPS) were performed with diagnostic catheters and ablation was performed with a 9FR, 8 mm tip, quadripolar cryocatheter (Freezor MAX catheter, CryoCath Technologies Inc., Kirkland, Canada). Cryoablation at -75 degrees C for 8 minutes was performed, beginning at the inferior rim of the coronary sinus (CS) os and creating a posterior line to the Eustachian ridge. Safety, bidirectional isthmus block at intervention, and recurrence at 3 months post procedure were assessed. RESULTS: There were no adverse events reported. All patients remained free of discomfort on cryoenergy delivery. The acute success rate at intervention was 96% for all patients and 100% for those with common atrial flutter. Follow-up data from 47 patients showed 33 (70%) patients without conduction recurrence on repeat EPS at 3 months. Although, 1 (2%) patient had both symptom and conduction recurrence. Data available from 53 acutely successful patients at 6 month clinical follow-up showed that 48 (91%) patients were asymptomatic and 5 (9%) patients had recurrence documented by ECG and/or patient diary records. CONCLUSIONS: Our experience with a new 9FR, 8 mm tip, quadripolar cryocatheter yielded a high success rate at intervention and an excellent safety profile. Although repeat EPS at 3 months post ablation identified conduction recurrence in 30% of patients, at 6 month clinical follow-up only 9% of patients had recurrence. Further monitoring is necessary to assess whether the relatively low recurrence rate observed at 6 month clinical follow-up is maintained over the long term.


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter/instrumentación , Criocirugía/instrumentación , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
20.
Medicine (Baltimore) ; 94(20): e608, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25997036

RESUMEN

Functional mitral regurgitation (FMR) is frequent in patients with heart failure (HF). It develops as a consequence of left ventricle (LV) geometry alterations, causing imbalance between increased tethering forces and decreased closing forces exerted on the mitral valve apparatus during systole.FMR is known to change at rest and during effort, due to preload-afterload changes, myocardial ischemia, and/or LV dysfunction. Despite optimized medical therapy, an FMR can be responsible of shortness of breath limiting quality of life and decompensation. In this report, we present a case of dynamic FMR treated with MitraClip.MitraClip implantation is a successful and innovative opportunity for HF patients with FMR.


Asunto(s)
Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Ecocardiografía , Femenino , Humanos , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA