1.
Nitric Oxide ; 146: 31-36, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38574950

RESUMEN

Carbon monoxide (CO) poisoning is a leading cause of poison-related morbidity and mortality worldwide. By binding to hemoglobin and other heme-containing proteins, CO reduces oxygen delivery and produces tissue damage. Prompt treatment of CO-poisoned patients is necessary to prevent acute and long-term complications. Oxygen therapy is the only available treatment. Visible light has been shown to selectively dissociate CO from hemoglobin with high efficiency without affecting oxygen affinity. Pulmonary phototherapy has been shown to accelerate the rate of CO elimination in CO poisoned mice and rats when applied directly to the lungs or via intra-esophageal or intra-pleural optical fibers. The extracorporeal removal of CO using a membrane oxygenator with optimal characteristic for blood exposure to light has been shown to accelerate the rate of CO illumination in rats with or without lung injury and in pigs. The development of non-invasive techniques to apply pulmonary phototherapy and the development of a compact, highly efficient membrane oxygenator for the extracorporeal removal of CO in humans may provide a significant advance in the treatment of CO poisoning.


Asunto(s)
Intoxicación por Monóxido de Carbono , Fototerapia , Intoxicación por Monóxido de Carbono/terapia , Animales , Humanos , Fototerapia/métodos , Monóxido de Carbono
2.
Skin Res Technol ; 30(7): e13834, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38923076

RESUMEN

BACKGROUND: Wound healing monitoring and timely decision-making are critical for wound classification. Tryptophan (Tr) intrinsic fluorescence, detected at 295/340 nm, provides a noninvasive approach for wound assessment. Our previous work demonstrated that this autofluorescence is associated with keratinocytes in a highly proliferative state in vitro. OBJECTIVE: We investigated the correlation between Tr fluorescence and key wound healing parameters, including re-epithelialization, fibrosis, neovascularization, and acute and chronic inflammation, using a rabbit model. METHODS: Seven rabbits underwent wound healing assessment over a 15-day period. We employed histological analysis from central and marginal biopsies, and UV fluorescence imaging captured by a monochromatic near-UV sensitive camera equipped with a passband optical filter (340 nm/12 nm). Excitation was achieved using a 295 nm LEDs ring lamp. Normalized fluorescence values were correlated with histological measurements using Pearson correlation. RESULTS: The UV fluorescence strongly exhibited a strong correlation with re-epithelization (r = 0.8) at the wound edge, with peak intensity observed between the sixth and ninth days. Notably, wound-healing dynamics differed between the wound center and edge, primarily attributed to variations in re-epithelialization, neovascularization, and chronic inflammation. CONCLUSION: Our findings highlight the presence of autofluorescence at 295/340 nm during wound healing, demonstrating a robust association with re-epithelialization. This excitation/emission signal holds promise as a valuable noninvasive strategy for monitoring wound closure, re-epithelialization, and other biological processes where Tr plays a pivotal role.


Asunto(s)
Repitelización , Triptófano , Cicatrización de Heridas , Animales , Conejos , Repitelización/fisiología , Cicatrización de Heridas/fisiología , Modelos Animales de Enfermedad , Fluorescencia , Piel/patología , Piel/lesiones , Imagen Óptica/métodos , Inflamación/patología , Rayos Ultravioleta
3.
Dermatol Surg ; 50(7): 616-619, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38518178

RESUMEN

BACKGROUND: Autofluorescence photography can detect specific light-tissue interactions and record important pathophysiological changes associated with nonmelanoma skin cancer (NMSC), which has been ascribed to the fluorescence of an aromatic amino acid, tryptophan. OBJECTIVE: To assess the impact of a novel, autofluorescence imaging (AFI) device on margin control for NMSCs before Mohs micrographic surgery (MMS) in an effort to decrease overall operating time. METHODS: Before the initial stage of MMS, NMSCs were measured with a 2-mm margin as standard of care (normal margin). The tumor was then imaged with the AFI device. A 2-mm margin was drawn around the fluorescent area captured by the AFI device and was referred to as the camera margin. The tumor was excised based on the normal margin and evaluated on frozen histological section. RESULTS: Imaging based on the AFI device resulted in appropriate recommendations for margin control in 8 of 11 tumors. Four of these tumors did not fluoresce and demonstrated a lack of tumor residuum on stage I specimen, as anticipated. There were no side effects from the AFI device. CONCLUSION: This is an initial pilot study that supports the use of a novel, noninvasive imaging device to help with margin assessment before MMS. On optimization, this device has potential to extend applicability to surgical excisions for tumors that do not fulfill criteria for MMS.


Asunto(s)
Márgenes de Escisión , Cirugía de Mohs , Imagen Óptica , Neoplasias Cutáneas , Humanos , Neoplasias Cutáneas/cirugía , Neoplasias Cutáneas/patología , Neoplasias Cutáneas/diagnóstico por imagen , Proyectos Piloto , Imagen Óptica/métodos , Imagen Óptica/instrumentación , Masculino , Femenino , Anciano , Carcinoma Basocelular/cirugía , Carcinoma Basocelular/patología , Carcinoma Basocelular/diagnóstico por imagen , Carcinoma de Células Escamosas/cirugía , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/diagnóstico por imagen , Persona de Mediana Edad , Anciano de 80 o más Años
4.
Lasers Surg Med ; 55(4): 390-404, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36883985

RESUMEN

BACKGROUND: Extracorporeal membrane oxygenators (ECMO) are currently utilized to mechanically ventilate blood when lung or lung and heart function are impaired, like in cases of acute respiratory distress syndrome (ARDS). ARDS can be caused by severe cases of carbon monoxide (CO) inhalation, which is the leading cause of poison-related deaths in the United States. ECMOs can be further optimized for severe CO inhalation using visible light to photo-dissociate CO from hemoglobin (Hb). In previous studies, we combined phototherapy with an ECMO to design a photo-ECMO device, which significantly increased CO elimination and improved survival in CO-poisoned animal models using light at 460, 523, and 620 nm wavelengths. Light at 620 nm was the most effective in removing CO. OBJECTIVE: The aim of this study is to analyze the light propagation at 460, 523, and 620 nm wavelengths and the 3D blood flow and heating distribution within the photo-ECMO device that increased CO elimination in CO-poisoned animal models. METHODS: Light propagation, blood flow dynamics, and heat diffusion were modeled using the Monte Carlo method and the laminar Navier-Stokes and heat diffusion equations, respectively. RESULTS: Light at 620 nm propagated through the device blood compartment (4 mm), while light at 460 and 523 nm only penetrated 48% to 50% (~2 mm). The blood flow velocity in the blood compartment varied with regions of high (5 mm/s) and low (1 mm/s) velocity, including stagnant flow. The blood temperatures at the device outlet for 460, 523, and 620 nm wavelengths were approximately 26.7°C, 27.4°C, and 20°C, respectively. However, the maximum temperatures within the blood treatment compartment rose to approximately 71°C, 77°C, and 21°C, respectively. CONCLUSIONS: As the extent of light propagation correlates with efficiency in photodissociation, the light at 620 nm is the optimal wavelength for removing CO from Hb while maintaining blood temperatures below thermal damage. Measuring the inlet and outlet blood temperatures is not enough to avoid unintentional thermal damage by light irradiation. Computational models can help eliminate risks of excessive heating and improve device development by analyzing design modifications that improve blood flow, like suppressing stagnant flow, further increasing the rate of CO elimination.


Asunto(s)
Intoxicación por Monóxido de Carbono , Oxigenación por Membrana Extracorpórea , Síndrome de Dificultad Respiratoria , Animales , Intoxicación por Monóxido de Carbono/terapia , Oxigenadores de Membrana , Oxigenación por Membrana Extracorpórea/métodos , Fototerapia/métodos , Síndrome de Dificultad Respiratoria/terapia
5.
Lasers Surg Med ; 55(6): 590-600, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37253390

RESUMEN

BACKGROUND AND OBJECTIVES: Approximately 50,000 emergency department visits per year due to carbon monoxide (CO) poisoning occur in the United States alone. Tissue hypoxia can occur at very low CO concentration exposures because CO binds with a 250-fold higher affinity than oxygen to hemoglobin. The most effective therapy is 100% hyperbaric oxygen (HBO) respiration. However, there are only a limited number of cases with ready accessibility to the specialized HBO chambers. In previous studies, we developed an extracorporeal veno-venous membrane oxygenator that facilitates exposure of blood to an external visible light source to photo-dissociate carboxyhemoglobin (COHb) and significantly increase CO removal from CO-poisoned blood (photo-extracorporeal veno-venous membrane oxygenator [p-ECMO]). One objective of this study was to describe in vitro experiments with different laser wavelength sources to compare CO elimination rates in a small unit-cell ECMO device integrated with a light-diffusing optical fiber. A second objective was to develop a mathematical model that predicts CO elimination rates in the unit-cell p-ECMO  device design upon which larger devices can be based. STUDY DESIGN/MATERIAL AND METHODS: Two small unit-cell p-ECMO devices consisted of a plastic capillary with a length and inside diameter of 10 cm and 1.15 mm, respectively. Either five (4-1 device) or seven (6-1 device) gas exchange tubes were placed in the plastic capillary and a light-diffusing fiber was inserted into one of the gas exchange tubes. Light from lasers emitting either 635 nm or 465 nm wavelengths was coupled into the light-diffusing fiber as oxygen flowed through the gas exchange membranes. To assess the ability of the device to remove CO from blood in vitro, the percent COHb reduction in a single pass through the device was assessed with and without light. The Navier Stokes equations, Carreau-Yesuda model, Boltzman equation for light distribution, and hemoglobin kinetic rate equations, including photo-dissociation, were combined in a mathematical model to predict COHb elimination in the experiments. RESULTS: For the unit-cell devices, the COHb removal rate increases with increased 635 nm laser power, increased blood time in the device, and greater gas exchange membrane surface-to-blood volume ratio. The 6-1 device COHb half-life versus that of the 4-1 device with 4 W at 635 nm light was 1.5 min versus 4.25 min, respectively. At 1 W laser power, 635 nm and 465 nm exhibited similar CO removal rates. The COHb half-life times of the 6-1 device were 1.25, 2.67, and 8.5 min at 635 nm (4 W), 465 nm (1 W), and 100% oxygen only, respectively. The mathematical model predicted the experimental results. An analysis of the in vivo COHb half-life of oxygen respiration therapy versus an adjunct therapy with a p-ECMO device and oxygen respiration shows a reduction from 90 min to as low as 10 min, depending on the device design. CONCLUSION: In this study, we experimentally studied and developed a mathematical model of a small unit-cell ECMO device integrated with a light-diffusing fiber illuminated with laser light. The unit-cell device forms the basis for a larger device and, in an adjunct therapy with oxygen respiration, has the potential to remove COHb at much higher rates than oxygen therapy alone. The mathematical model can be used to optimize the design in practical implementations to quickly and efficiently remove CO from CO-poisoned blood.


Asunto(s)
Intoxicación por Monóxido de Carbono , Humanos , Intoxicación por Monóxido de Carbono/terapia , Oxigenadores de Membrana , Hemoglobinas/análisis , Hemoglobinas/metabolismo , Carboxihemoglobina/análisis , Carboxihemoglobina/metabolismo , Oxígeno , Modelos Teóricos
6.
Lasers Surg Med ; 54(1): 182-188, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34859909

RESUMEN

OBJECTIVE: The objective of this study was to develop a patch that can be placed on the skin during laser hair removal and similar procedures, that serves to reduce the laser-induced plume, provides a ready indicator to the laser surgeon of where pulses have been applied, and cools the skin. METHODS: A two-layer patch composed of a cooling hydrogel layer and an indicator layer was optimized and tested ex vivo. The hydrogel was composed of gelatin and glycerin. The concentration of each hydrogel component was optimized to determine the minimum gelatin concentration at which the gel can be handled without breakage and the minimum glycerin concentration that allows for storage at -20°C without crystallization. This is the temperature of a conventional freezer; application of the cooling layer to the skin would help prevent epidermal injury. The indicator layer was composed of a plastic transparency sheet with small dots of black ink particles printed onto its surface. Transparency sheets were printed from templates created in Adobe Photoshop in which dots are at a specified density; additionally, Photoshop's opacity function was used to vary the opacity of the dots themselves. Performance was tested using a 755 nm alexandrite laser used clinically for hair removal by measuring light transmission through the patch and observing the sheet's ability to indicate the location of laser exposures. The transmittance of patch components across a broad spectrum was also measured using a microplate reader. Several adhesives, including a two-part epoxy, silicone rubber, and cyanoacrylate, were tested for their ability to adhere to the hydrogel and indicator layers. Assembled patches composed of the hydrogel layer, indicator layer, and adhesive were tested ex vivo for their ability to mitigate the laser hair removal plume by measuring airborne particulate matter during simulated laser hair removal. RESULTS: A minimum gelatin concentration of 5% was found to enable easy handling of the hydrogel. A mixture composed of 60% water and 40% glycerin by volume consistently allowed storage at -20°C without crystallization. For the indicator layer, ink particle density of 50% and opacity of 5% provided a readily apparent indicator function following laser exposure. Transmission through the sheet measured during alexandrite laser exposures was 90% and was not different than transmission through the sheet alone without ink particles. A cyanoacrylate glue was found to adhere to the hydrogel and indicator layers, while the other adhesives proved inadequate. Measurements using a microplate reader confirmed that the reflection from the transparency sheet itself was the primary contributor to energy loss. In experiments exposing hair clippings to the laser with and without the patch, the patch allowed an increase of 5000 particles/cc relative to baseline particles in the environmental air, while the absence of the patch allowed an increase of 150,000 particles/cc relative to baseline, indicating that the patch decreased particle debris in the plume by 97%. CONCLUSIONS: A two-layer patch composed of hydrogel and plastic indicator layer with cyanoacrylate adhesive can be stored in a conventional freezer without crystallization, then placed over an area of skin to be treated for laser hair removal. The patch clearly indicates the pattern and sites of laser exposure, while blocking almost all (97%) of particles in the laser-induced plume. Future work will include safety validation and in vivo testing of efficacy, as these were not undertaken in this study.


Asunto(s)
Remoción del Cabello , Terapia por Láser , Láseres de Estado Sólido , Estudios de Factibilidad , Material Particulado
7.
Lasers Surg Med ; 54(3): 426-432, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34658052

RESUMEN

BACKGROUND AND OBJECTIVES: Carbon monoxide (CO) poisoning is responsible for nearly 50,000 emergency department visits and 1200 deaths per year. Compared to oxygen, CO has a 250-fold higher affinity for hemoglobin (Hb), resulting in the displacement of oxygen from Hb and impaired oxygen delivery to tissues. Optimal treatment of CO-poisoned patients involves the administration of hyperbaric 100% oxygen to remove CO from Hb and to restore oxygen delivery. However, hyperbaric chambers are not widely available and this treatment requires transporting a CO-poisoned patient to a specialized center, which can result in delayed treatment. Visible light is known to dissociate CO from carboxyhemoglobin (COHb). In a previous study, we showed that a system composed of six photo-extracorporeal membrane oxygenation (ECMO) devices efficiently removes CO from a large animal with CO poisoning. In this study, we tested the hypothesis that the application of hyperbaric oxygen to the photo-ECMO device would further increase the rate of CO elimination. STUDY DESIGN/MATERIAL AND METHODS: We developed a hyperbaric photo-ECMO device and assessed the ability of the device to remove CO from CO-poisoned human blood. We combined four devices into a "hyperbaric photo-ECMO system" and compared its ability to remove CO to our previously described photo-ECMO system, which was composed of six devices ventilated with normobaric oxygen. RESULTS: Under normobaric conditions, an increase in oxygen concentration from 21% to 100% significantly increased CO elimination from CO-poisoned blood after a single pass through the device. Increased oxygen pressure within the photo-ECMO device was associated with higher exiting blood PO2 levels and increased CO elimination. The system of four hyperbaric photo-ECMO devices removed CO from 1 L of CO-poisoned blood as quickly as the original, normobaric photo-ECMO system composed of six devices. CONCLUSION: This study demonstrates the feasibility and efficacy of using a hyperbaric photo-ECMO system to increase the rate of CO elimination from CO-poisoned blood. This technology could provide a simple portable emergency device and facilitate immediate treatment of CO-poisoned patients at or near the site of injury.


Asunto(s)
Intoxicación por Monóxido de Carbono , Monóxido de Carbono , Animales , Intoxicación por Monóxido de Carbono/complicaciones , Intoxicación por Monóxido de Carbono/terapia , Carboxihemoglobina , Hemoglobinas , Humanos , Oxígeno , Fototerapia/métodos
8.
Lasers Surg Med ; 54(2): 256-267, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34350599

RESUMEN

BACKGROUND AND OBJECTIVES: Carbon monoxide (CO) inhalation is the leading cause of poison-related deaths in the United States. CO binds to hemoglobin (Hb), displaces oxygen, and reduces oxygen delivery to tissues. The optimal treatment for CO poisoning in patients with normal lung function is the administration of hyperbaric oxygen (HBO). However, hyperbaric chambers are only available in medical centers with specialized equipment, resulting in delayed therapy. Visible light dissociates CO from Hb with minimal effect on oxygen binding. In a previous study, we combined a membrane oxygenator with phototherapy at 623 nm to produce a "mini" photo-ECMO (extracorporeal membrane oxygenation) device, which improved CO elimination and survival in CO-poisoned rats. The objective of this study was to develop a larger photo-ECMO device ("maxi" photo-ECMO) and to test its ability to remove CO from a porcine model of CO poisoning. STUDY DESIGN/MATERIALS AND METHODS: The "maxi" photo-ECMO device and the photo-ECMO system (six maxi photo-ECMO devices assembled in parallel), were tested in an in vitro circuit of CO poisoning. To assess the ability of the photo-ECMO device and the photo-ECMO system to remove CO from CO-poisoned blood in vitro, the half-life of COHb (COHb-t1/2 ), as well as the percent COHb reduction in a single blood pass through the device, were assessed. In the in vivo studies, we assessed the COHb-t1/2 in a CO-poisoned pig under three conditions: (1) While the pig breathed 100% oxygen through the endotracheal tube; (2) while the pig was connected to the photo-ECMO system with no light exposure; and (3) while the pig was connected to the photo-ECMO system, which was exposed to red light. RESULTS: The photo-ECMO device was able to fully oxygenate the blood after a single pass through the device. Compared to ventilation with 100% oxygen alone, illumination with red light together with 100% oxygen was twice as efficient in removing CO from blood. Changes in gas flow rates did not alter CO elimination in one pass through the device. Increases in irradiance up to 214 mW/cm2 were associated with an increased rate of CO elimination. The photo-ECMO device was effective over a range of blood flow rates and with higher blood flow rates, more CO was eliminated. A photo-ECMO system composed of six photo-ECMO devices removed CO faster from CO-poisoned blood than a single photo-ECMO device. In a CO-poisoned pig, the photo-ECMO system increased the rate of CO elimination without significantly increasing the animal's body temperature or causing hemodynamic instability. CONCLUSION: In this study, we developed a photo-ECMO system and demonstrated its ability to remove CO from CO-poisoned 45-kg pigs. Technical modifications of the photo-ECMO system, including the development of a compact, portable device, will permit treatment of patients with CO poisoning at the scene of their poisoning, during transit to a local emergency room, and in hospitals that lack HBO facilities.


Asunto(s)
Intoxicación por Monóxido de Carbono , Venenos , Animales , Monóxido de Carbono , Intoxicación por Monóxido de Carbono/terapia , Carboxihemoglobina/metabolismo , Humanos , Fototerapia/métodos , Ratas , Porcinos
9.
Lasers Surg Med ; 53(2): 245-251, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32538499

RESUMEN

BACKGROUND AND OBJECTIVES: Mycological diagnosis of onychomycosis is based on direct microscopy using external fluorophores to visualize fungal tissue in nail samples and agar culture. Ultraviolet fluorescence excitation imaging (u-FEI) has shown potential in monitoring biological processes by exploiting variations in autofluorescence. This study aimed at assessing the potential of a handheld u-FEI system as a practical screening tool for fungal nail infections. STUDY DESIGN/MATERIALS AND METHODS: Ninety samples from 29 patients with microscopy-confirmed fungal infection and 10 control samples from healthy participants were collected (n = 100). Using a prototype u-FEI system (single bandpass 25 mm filter with a central pass wavelength of 340 nm and a bandwidth of 12 nm, 295 nm excitation flash, resolution of 640 × 480), images of all samples were acquired under standardized conditions. Average and maximum fluorescence intensity image values in arbitrary units (AU) of manually delineated regions of interests were quantitated and statistically assessed for significant differences between healthy and mycotic samples. RESULTS: UV-images clearly depicted all 100 nail samples, with a visibly stronger signal in infected samples. Statistically significant differences (P < 0.05) in signal intensity between mycotic samples and healthy controls were observed for maximum and average fluorescence values. Mean fluorescence values of onychomycotic samples showed 23.9% higher maximum (mycotic: 34.9 AU [standard deviation [SD] 4.7]; healthy: 28.2 AU [SD 1.9]) and 10.2% higher average (mycotic: 27.6 AU [SD 2.0]; healthy: 25.0 AU [SD 0.7]) signal intensity values. Receiver operating characteristic curves demonstrated excellent discriminatory ability (area under the curve > 0.9). Analysis of fluorescence measurements of the reference standard demonstrated very low variation (coefficient of variation = 0.62%) CONCLUSION: Quantitation of u-FEI intensities enables differentiation between healthy and mycotic nail samples, constituting a potential point-of-care tool for cost-effective screening for onychomycosis at a primary care level. Lasers Surg. Med. © 2020 Wiley Periodicals LLC.


Asunto(s)
Onicomicosis , Humanos , Rayos Láser , Onicomicosis/diagnóstico por imagen , Imagen Óptica
10.
J Fluoresc ; 30(2): 249-257, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31981011

RESUMEN

Build-up of extracellular matrix in liver fibrosis results in changes on endogenous molecules expression that may be studied through the fluorescence characterization of ex vivo liver samples. To the best of our knowledge, no investigations have provided in-depth evidence and discussion on the changes of the endogenous fluorescence in ex vivo tissue due to the effects of the preservation media. In this work, we contrast and analyze the endogenous fluorescence from tryptophan, vitamin A, hydroxyproline and elastin cross-links potential biomarkers of the liver fibrosis, in in vivo measurements and liver samples preserved on formaldehyde, and two standard preservation media. As it is known, chemical changes in tissue, caused by formaldehyde fixation, alter the endogenous fluorescence spectra. We propose the use of phosphate-buffered saline (PBS), and Iscove's Modified Dulbecco's Medium (IMDM) to elude the fluorescence changes. PBS and IMDM showed to maintain the endogenous fluorescence characteristics similar to in vivo conditions. The results of this work point the way for a more reliable assessment of endogenous fluorescence in ex vivo hepatic studies.


Asunto(s)
Fluorescencia , Hidroxiprolina/análisis , Cirrosis Hepática/diagnóstico , Triptófano/análisis , Vitamina A/análisis , Biomarcadores/análisis , Medios de Cultivo/química , Formaldehído , Humanos , Cirrosis Hepática/inducido químicamente , Fosfatos/química , Cloruro de Sodio/química , Espectrometría de Fluorescencia
11.
Lasers Surg Med ; 51(2): 201-207, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30113081

RESUMEN

BACKGROUND AND OBJECTIVE: Dermatophytes are fungi that cause infections in hair, skin, and nails. Potassium Hydroxide (KOH) microscopy is the most frequently used method for identifying dermatophytes. KOH helps in the visualization of the hyphae as it clears the debris present in the specimen but needs a trained eye for final diagnosis of the infection. Fluorescence microscopy using staining agents, such as calcofluor white (CFW) or blankophor, is a better method for identification of dermatophytes but is not used in clinics due to the cost and complexity of fluorescence microscopes. The objective of the present work is to develop a simple low-cost mobile phone-based device for the identification of fungal pathogens in skin samples. MATERIALS AND METHODS: A fluorescence spectrometer was used to establish the excitation/emission peaks of fluorescence intensity of CFW and KOH and Methyl Cellulose, a surrogate of fungi used for system development. A transillumination microscopy prototype was fabricated using off-the-shelf components, 3D printing and a mobile phone. The system was optically characterized using contrast resolution targets and verified using fungi isolate samples. An isolate of Trichophyton (T) rubrum was grown for 10-14 days for formation of fungal colonies. The surface of a single colony was gently scraped with a sterile loop and transferred to a glass slide. CFW with KOH was added to the T. rubrum and covered with cover slip for microscopic examination. The images of T. rubrum obtained with the prototype device were compared to those obtained using a commercial microscope. RESULTS: The excitation/emission wavelength pair for CFW was found to be 370/430 nm. The proposed device design is a transillumination microscopy setup using a mobile phone. It consists of a 365 nm LED as the excitation source, a 3V battery to power the LED, a slide to hold the sample, a lens for magnification and a phone to capture and store the images of the sample. The fabricated prototype has a resolution of 70 to 99 µm, a 2% to 30% distortion, and 60% contrast value for well illuminated samples. Images of T. rubrum samples obtained under brightfield illumination clearly show the long septate hyphae of the dermatophyte. As expected, images of the same samples with CFW and KOH show blue fluorescence, which results from the binding of the CFW to the chitin and cellulose in the fungal hyphae. These images are similar to those obtained with a commercial microscope. SUMMARY AND CONCLUSIONS: The concept and design of a mobile phone-based fluorescence microscope to identify dermatophytes has been demonstrated in a prototype and laboratory samples. The concept and design offer a simple, low-cost, compact but robust method for identification of fungal pathogens. This method is shown to be feasible for detecting fluorescence accurately and imaging the fungal structure at a resolution of 100 µm or better. Lasers Surg. Med. 51:201-207, 2019. © 2018 Wiley Periodicals, Inc.


Asunto(s)
Teléfono Celular , Microscopía Fluorescente , Trichophyton , Bencenosulfonatos , Diseño de Equipo , Coloración y Etiquetado/métodos
12.
Int J Hyperthermia ; 34(4): 363-372, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-28610551

RESUMEN

In many dermatological applications, lowering the temperature of skin and maintaining specific temperatures for extended periods of time are fundamental requirements for treatment; for example, in targeting adipose tissue and managing cutaneous pain. In this work, we investigate the feasibility of using phase changing materials (PCMs) as an alternative passive, open-loop, heat extraction method for cooling cutaneous and subcutaneous tissues. We used a finite difference parametric approach to model the spatial and temporal progression of the heat transferred from the skin to a PCM in contact with the skin surface. We modelled the thermal performance of different PCMs, including different thicknesses. In addition, we used our model to propose application strategies. Numerical simulations demonstrate the feasibility of using PCMs for extracting heat from the skin and upper fat layers, inducing and maintaining similar temperatures as those induced by active closed-loop cooling with a cold plate. In terms of development, the critical design parameters are the temperature range of solidification of the material, the thickness of the material, and the rate of melting. Our study suggests that PCM-based devices may offer an alternative skin and adipose tissue cooling method that is simple to implement and use.


Asunto(s)
Tejido Adiposo , Modelos Teóricos , Músculos , Transición de Fase , Temperatura Cutánea , Agar , Estudios de Factibilidad , Calor , Humanos , Hielo , Piel , Termodinámica
13.
Lasers Surg Med ; 50(10): 1034-1039, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29873404

RESUMEN

OBJECTIVE: The identification of veins by medical personnel is a critical skill that is necessary to draw blood or administer intravenous fluids and medications. Because a normal consumer camera can act as a multispectral imaging apparatus, operating with three broadband detectors, we hypothesized that a standard smartphone camera might be employed for enhanced visualization of veins in human skin. STUDY: Video and images of subcutaneous veins were acquired using the rear-facing iSight camera from an iPhone 6, with a fixed aperture of f/2.2, and Sony Exmor RS back-illuminated CMOS image sensor with pixel generation of 1.5 microns. A custom program was written for the iOS operating system that performs a scaled matrix subtraction of different spectral channels and displays results as a grayscale image. RESULTS: A scaled subtraction of green channel pixel values from red channel pixel values enabled greatly improved identification of subcutaneous veins. Wavelengths of light at which the green detector is most sensitive (520-580 nm) correspond to local absorption maxima of both oxyhemoglobin (542 and 576 nm) and deoxyhemoglobin (556 nm); consequently, the algorithm obtained images of light transport weighted toward deeper skin layers. CONCLUSION: We identified and developed a simple algorithm by which a standard smartphone camera can be employed for enhanced video-rate visualization of veins in human skin. Lasers Surg. Med. 50:1034-1039, 2018. © 2018 Wiley Periodicals, Inc.


Asunto(s)
Piel/irrigación sanguínea , Piel/diagnóstico por imagen , Teléfono Inteligente , Algoritmos , Humanos , Técnica de Sustracción , Grabación en Video
14.
Am J Respir Crit Care Med ; 192(10): 1191-9, 2015 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-26214119

RESUMEN

RATIONALE: Carbon monoxide (CO) exposure is a leading cause of poison-related mortality. CO binds to Hb, forming carboxyhemoglobin (COHb), and produces tissue damage. Treatment of CO poisoning requires rapid removal of CO and restoration of oxygen delivery. Visible light is known to effectively dissociate CO from Hb, with a single photon dissociating one CO molecule. OBJECTIVES: To determine whether illumination of the lungs of CO-poisoned mice causes dissociation of COHb from blood transiting the lungs, releasing CO into alveoli and thereby enhancing the rate of CO elimination. METHODS: We developed a model of CO poisoning in anesthetized and mechanically ventilated mice to assess the effects of direct lung illumination (phototherapy) on the CO elimination rate. Light at wavelengths between 532 and 690 nm was tested. The effect of lung phototherapy administered during CO poisoning was also studied. To avoid a thoracotomy, we assessed the effect of lung phototherapy delivered to murine lungs via an optical fiber placed in the esophagus. MEASUREMENTS AND MAIN RESULTS: In CO-poisoned mice, phototherapy of exposed lungs at 532, 570, 592, and 628 nm dissociated CO from Hb and doubled the CO elimination rate. Phototherapy administered during severe CO poisoning limited the blood COHb increase and improved the survival rate. Noninvasive transesophageal phototherapy delivered to murine lungs via an optical fiber increased the rate of CO elimination while avoiding a thoracotomy. CONCLUSIONS: Future development and scaling up of lung phototherapy for patients with CO exposure may provide a significant advance for treating and preventing CO poisoning.


Asunto(s)
Intoxicación por Monóxido de Carbono/terapia , Carboxihemoglobina/metabolismo , Fototerapia/métodos , Animales , Intoxicación por Monóxido de Carbono/sangre , Carboxihemoglobina/análisis , Modelos Animales de Enfermedad , Tasa de Depuración Metabólica/fisiología , Ratones
15.
Lasers Surg Med ; 48(4): 377-84, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26990874

RESUMEN

BACKGROUND AND OBJECTIVE: Collagen gels containing cells are commonly used in tissue engineering, wound healing, and cancer research to investigate the interplay between cells and the extracellular matrix (ECM), as changes in the density and stiffness of the microenvironment are known to play a role in many diseases or pathological conditions. In these gels, the stiffness is regularly determined using destructive methods, such as indentation and tensile tests. Certain molecules native to cells and the ECM display fluorescence upon irradiation with ultraviolet light. The objective of the present study was to investigate the feasibility of using the endogenous, or innate, fluorescence of collagen gels containing fibroblasts as an optical marker to evaluate changes in the mechanical properties of the ECM. MATERIALS AND METHODS: Human foreskin fibroblasts cells at concentrations of 50,000 and 100,000 cells/ml were cultured in three-dimensional gels of type I collagen for 16 days. Fibroblast cells remodeled the ECM, contracting and increasing the stiffness of the gel. During this remodeling process, changes in mechanical properties and fluorescence were measured with an indentation test and a spectrofluorometer, respectively. Force and displacement measurements from the indentation test were used to calculate the elastic modulus of the gel. Maps of fluorescence intensity, at excitation/emission of 240-520/290-530 nm, were used to identify the wavelengths of interest. RESULTS: Fluorescence excitation/emission maps exhibited two distinct excitation/emission bands whose intensities increased as the fibroblasts remodeled and increased the stiffness of the ECM: The 290/340 nm band ascribed to tryptophan and the 330/390 nm band ascribed to cross-links of collagen (pepsin-digestible cross-links). A Spearman correlation analysis, between the elastic modulus of the gel containing fibroblasts and the fluorescence of cross-links of collagen, resulted in R = 0.95 (P < 0.05) and R = 0.77 (P = 0.12) for 50,000 and 100,000 cells/ml, respectively. CONCLUSIONS: The endogenous fluorescence intensity ascribed to pepsin-digestible cross-links of collagen may serve as an optical marker to evaluate changes in the mechanical properties of the ECM; this is relevant to collagenous tissues for which pathological states are related to mechanical alterations, such as keratoconus in cornea and osteoarthritis in articular cartilage.


Asunto(s)
Colágeno Tipo I/fisiología , Matriz Extracelular/fisiología , Fibroblastos/fisiología , Imagen Óptica/métodos , Biomarcadores , Fenómenos Biomecánicos , Células Cultivadas , Módulo de Elasticidad , Estudios de Factibilidad , Humanos , Espectrometría de Fluorescencia
16.
Lasers Surg Med ; 48(7): 678-85, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27075645

RESUMEN

BACKGROUND AND OBJECTIVE: Molecules native to tissue that fluoresce upon light excitation can serve as reporters of cellular activity and protein structure. In skin, the fluorescence ascribed to tryptophan is a marker of cellular proliferation, whereas the fluorescence ascribed to cross-links of collagen is a structural marker. In this work, we introduce and demonstrate a simple but robust optical method to image the functional process of epithelialization and the exposed dermal collagen in wound healing of human skin in an organ culture model. MATERIALS AND METHODS: Non-closing non-grafted, partial closing non-grafted, and grafted wounds were created in ex vivo human skin and kept in culture. A wide-field UV fluorescence excitation imaging system was used to visualize epithelialization of the exposed dermis and quantitate wound area, closure, and gap. Histology (H&E staining) was also used to evaluate epithelialization. RESULTS: The endogenous fluorescence excitation of cross-links of collagen at 335 nm clearly shows the dermis missing epithelium, while the endogenous fluorescence excitation of tryptophan at 295 nm shows keratinocytes in higher proliferating state. The size of the non-closing wound was 11.4 ± 1.8 mm and remained constant during the observation period, while the partial-close wound reached 65.5 ± 4.9% closure by day 16. Evaluations of wound gaps using fluorescence excitation images and histology images are in agreement. CONCLUSIONS: We have established a fluorescence imaging method for studying epithelialization processes, evaluating keratinocyte proliferation, and quantitating closure during wound healing of skin in an organ culture model: the dermal fluorescence of pepsin-digestible collagen cross-links can be used to quantitate wound size, closure extents, and gaps; and, the epidermal fluorescence ascribed to tryptophan can be used to monitor and quantitate functional states of epithelialization. UV fluorescence excitation imaging has the potential to become a valuable tool for research, diagnostic and educational purposes on evaluating the healing of wounds. Lasers Surg. Med. 48:678-685, 2016. © 2016 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.


Asunto(s)
Imagen Óptica/métodos , Repitelización/fisiología , Piel/diagnóstico por imagen , Rayos Ultravioleta , Biomarcadores/metabolismo , Colágeno/metabolismo , Humanos , Técnicas de Cultivo de Órganos , Piel/lesiones , Piel/metabolismo
17.
Lasers Surg Med ; 47(2): 183-95, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25651998

RESUMEN

BACKGROUND AND OBJECTIVE: Radiofrequency currents are commonly used in dermatology to treat cutaneous and subcutaneous tissues by heating. The subcutaneous morphology of tissue consists of a fine, collagenous and fibrous septa network enveloping clusters of adipocyte cells. The architecture of this network, namely density and orientation of septa, varies among patients and, furthermore, it correlates with cellulite grading. In this work we study the effect of two clinically relevant fibrous septa architectures on the thermal and elastic response of subcutaneous tissue to the same RF treatment; in particular, we evaluate the thermal damage and thermal stress induced to an intermediate- and a high-density fibrous septa network architecture that correspond to clinical morphologies of 2.5 and 0 cellulite grading, respectively. STUDY DESIGN/MATERIALS AND METHODS: We used the finite element method to assess the electric, thermal and elastic response of a two-dimensional model of skin, subcutaneous tissue and muscle subjected to a relatively long, constant, low-power RF treatment. The subcutaneous tissue is constituted by an interconnected architecture of fibrous septa and fat lobules obtained by processing micro-MRI sagittal images of hypodermis. As comparison criteria for the RF treatment of the two septa architectures, we calculated the accumulated thermal damage that corresponds to 63% loss in cell viability. RESULTS: Electric currents preferentially circulated through the fibrous septa in the subcutaneous tissue. However, the intensity of the electric field was higher within the fat because it is a poor electric conductor. The power absorption in the fibrous septa relative to that in the fat varied with septum orientation: it was higher in septa with vertical orientation and lower in septa with horizontal orientation. Overall, maximum values of electric field intensity, power absorption and temperature were similar for both fibrous septa architectures. However, the high-density septa architecture (cellulite grade 0) had a more uniform and broader spatial distribution of power absorption, resulting in a larger cross-sectional area of thermal damage (≈1.5 times more). Volumetric strains (expansion and contraction) were small and similar for both network architectures. During the first seconds of RF exposure, the fibrous septa were subjected to thermal expansion regardless of orientation. In the long term, the fibrous septa contracted due to the thermal expansion of fat. Skin and muscle were subjected to significantly higher Von Mises stresses (measure of yield) or distortion energy than the subcutaneous tissue. CONCLUSION: The distribution of electric currents within subcutaneous tissues depends on tissue morphology. The electric field is more intense in septum oriented along the skin to muscle (top to bottom) direction, creating lines or planes of preferential heating. It follows that the more septum available for preferential heating, the larger the extent of volumetric RF-heating and thermal damage to the subcutaneous tissue. Thermal load alone, imposed by long-exposure to heating up to 50 °C, results in small volumetric expansion and contraction in the subcutaneous tissue. The subcutaneous tissue is significantly less prone to non-reversible deformation by a thermal load than the skin and muscle.


Asunto(s)
Tejido Adiposo/efectos de la radiación , Músculos/efectos de la radiación , Ondas de Radio , Piel/efectos de la radiación , Tejido Subcutáneo/efectos de la radiación , Elasticidad/efectos de la radiación , Análisis de Elementos Finitos , Humanos , Modelos Biológicos , Conductividad Térmica
18.
Lasers Surg Med ; 45(5): 326-38, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23733512

RESUMEN

BACKGROUND AND OBJECTIVES: Radiofrequency (RF) energy exposure is a popular non-invasive method for generating heat within cutaneous and subcutaneous tissues. Subcutaneous fat consists of fine collagen fibrous septa meshed with clusters of adipocytes having distinct structural, electrical and thermal properties that affect the distribution and deposition of RF energy. The objectives of this work are to (i) determine the electric and thermal effects of the fibrous septa in the RF heating; (ii) investigate the RF heating of individual fat lobules enclosed by fibrous septa; and, (iii) discuss the clinical implications. METHODS AND RESULTS: We used the finite element method to model the two-dimensional, time-dependent, electro-thermal response of a three-layer tissue (skin, subcutaneous fat, and muscle). We considered two different configurations of subcutaneous fat tissue: a homogenous layer of fat only and a honeycomb-like layer of fat with septa. Architecture of the fibrous septa was anatomically accurate, constructed from sagittal images from human micro-MRI. For a large electrode applied to the skin surface, results show that the absorbed electric power density is greater in some septa than in the surrounding fat lobules, favoring the flux of electric current density. Fibers aligned parallel to the electric field have higher electric flux and, consequently, absorb more power. Heat transfer from the septa occurs over time during and after RF energy delivery. There is a greater temperature rise in fat with fibrous septa. CONCLUSIONS: The presence of septa affects the local distribution of the static electric field, facilitates the flux of electric current and enhances the bulk electric power absorption of the subcutaneous fat layer. Fibrous septa aligned with the local electric field have higher absorbed power density than septa oriented perpendicular to the electric field. Individual fat lobules gain heat instantly by local power absorption and, eventually, by diffusion from the surrounding septa.


Asunto(s)
Diatermia , Músculos/efectos de la radiación , Piel/efectos de la radiación , Grasa Subcutánea/efectos de la radiación , Tejido Subcutáneo/efectos de la radiación , Conductividad Eléctrica , Análisis de Elementos Finitos , Humanos , Modelos Biológicos , Conductividad Térmica
19.
Bioengineering (Basel) ; 10(8)2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37627854

RESUMEN

We designed a photo-ECMO device to speed up the rate of carbon monoxide (CO) removal by using visible light to dissociate CO from hemoglobin (Hb). Using computational fluid dynamics, fillets of different radii (5 cm and 10 cm) were applied to the square shape of a photo-ECMO device to reduce stagnant blood flow regions and increase the treated blood volume while being constrained by full light penetration. The blood flow at different flow rates and the thermal load imposed by forty external light sources at 623 nm were modeled using the Navier-Stokes and convection-diffusion equations. The particle residence times were also analyzed to determine the time the blood remained in the device. There was a reduction in the blood flow stagnation as the fillet radii increased. The maximum temperature change for all the geometries was below 4 °C. The optimized device with a fillet radius of 5 cm and a blood priming volume of up to 208 cm3 should decrease the time needed to treat CO poisoning without exceeding the critical threshold for protein denaturation. This technology has the potential to decrease the time for CO removal when treating patients with CO poisoning and pulmonary gas exchange inhibition.

20.
Cancers (Basel) ; 15(9)2023 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-37174030

RESUMEN

Mitochondria are regulators of key cellular processes, including energy production and redox homeostasis. Mitochondrial dysfunction is associated with various human diseases, including cancer. Importantly, both structural and functional changes can alter mitochondrial function. Morphologic and quantifiable changes in mitochondria can affect their function and contribute to disease. Structural mitochondrial changes include alterations in cristae morphology, mitochondrial DNA integrity and quantity, and dynamics, such as fission and fusion. Functional parameters related to mitochondrial biology include the production of reactive oxygen species, bioenergetic capacity, calcium retention, and membrane potential. Although these parameters can occur independently of one another, changes in mitochondrial structure and function are often interrelated. Thus, evaluating changes in both mitochondrial structure and function is crucial to understanding the molecular events involved in disease onset and progression. This review focuses on the relationship between alterations in mitochondrial structure and function and cancer, with a particular emphasis on gynecologic malignancies. Selecting methods with tractable parameters may be critical to identifying and targeting mitochondria-related therapeutic options. Methods to measure changes in mitochondrial structure and function, with the associated benefits and limitations, are summarized.

SELECCIÓN DE REFERENCIAS