J Clin Microbiol ; 56(8)2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29618500

RESUMEN

The analytical performance of the AIX1000 system, a fully automated and recently FDA-cleared rapid plasma reagin (RPR) system, was evaluated by comparison to a manual RPR test in a traditional syphilis testing algorithm. A total of 1,028 consecutive serum samples submitted for syphilis testing to the University of North Carolina Hospitals Clinical Immunology Laboratory were tested per each manufacturer's instructions. Among those samples, 996 were nonreactive and 20 were reactive using both the ASI RPR card system and the AIX1000 system. Of the 12 discrepant specimens, 11 were AIX1000 reactive and ASI card nonreactive whereas 1 specimen was ASI card reactive and AIX1000 nonreactive. The sensitivity and specificity of the manual ASI card were 76.0% and 99.8%, respectively, while the sensitivity and specificity of the AIX100 were 100.0% and 99.4%, respectively (sensitivity P = 0.03). Among the 20 concordant reactive specimens, 68.4% of the titers agreed within ±1 dilution between methods. Reproducibility testing of the AIX1000 system demonstrated qualitative and semiquantitative (within ±1 dilution) agreement between specimens tested on different days of 96.0% and 76.0%, respectively, and 100.0% agreement between replicates within the same run. One of 24 samples analyzed under other disease conditions was reactive on both the AIX1000 system and the ASI card. Overall, the fully automated AIX1000 system demonstrated significantly enhanced sensitivity and specificity similar to that of the manual ASI RPR card test, making the AIX1000 system suitable for the laboratory diagnosis of syphilis in a clinical laboratory setting.


Asunto(s)
Juego de Reactivos para Diagnóstico/normas , Reaginas/sangre , Serodiagnóstico de la Sífilis/métodos , Sífilis/diagnóstico , Treponema pallidum/aislamiento & purificación , Anticuerpos Antibacterianos/sangre , Automatización de Laboratorios , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Serodiagnóstico de la Sífilis/instrumentación , Treponema pallidum/inmunología
3.
Clin Diagn Lab Immunol ; 11(2): 297-301, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15013979

RESUMEN

Detection and specificity of autoantibodies against extractable nuclear antigens (ENA) play a critical role in the diagnosis and management of autoimmune disease. Historically, the detection of these antibodies has employed double immunodiffusion (DID). Autoantibody specificity was correlated with diagnoses by this technique. Enzyme immunoassays have been developed by multiple manufacturers to detect and identify the specificity ENA autoantibodies. To address the relationship of ENA detection by DID and enzyme immunoassay, the performances of five immunoassays were compared. These included two DID and three enzyme-linked immunoassays (ELISA) (both screening and individual antigen profile kits). The sample set included 83 ENA-positive, antinuclear-antibody (ANA)-positive specimens, 77 ENA-negative, ANA-positive specimens, and 20 ENA- and ANA-negative specimens. Sensitivity and specificity were calculated by two methods: first, by using the in-house DID result as the reference standard, and second, by using latent class analysis, which evaluates each kit result independently. Overall, the results showed that the ELISA methods were more sensitive for detection of ENA autoantibodies than DID techniques, but presence and/or specific type of ENA autoantibody did not always correlate with the patient's clinical presentation. Regardless of the testing strategy an individual laboratory uses, clear communication with the clinical staff regarding the significance of a positive result is imperative. The laboratory and the clinician must both be aware of the sensitivity and specificity of each testing method in use in the clinical laboratory.


Asunto(s)
Especificidad de Anticuerpos , Antígenos Nucleares/inmunología , Autoanticuerpos/inmunología , Enfermedades Autoinmunes/diagnóstico , Ensayo de Inmunoadsorción Enzimática , Autoanticuerpos/análisis , Enfermedades Autoinmunes/inmunología , Epítopos , Humanos , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad