1.
ACS Sens ; 5(10): 3025-3030, 2020 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-32964706

RESUMEN

Portable and inexpensive analytical tools are required to monitor pharmaceutical quality in technology limited settings including low- and middle-income countries (LMICs). Whole cell yeast biosensors have the potential to help meet this need. However, most of the readouts for yeast biosensors require expensive equipment or reagents. To overcome this challenge, we have designed a yeast biosensor that produces a unique scent as a readout. This inducible scent biosensor, or "scentsor", does not require the user to administer additional reagents for reporter development and utilizes only the user's nose to be "read". In this Letter, we describe a scentsor that is responsive to the hormone estradiol (E2). The best estimate threshold (BET) for E2 detection with a panel of human volunteers (n = 49) is 39 nM E2 (15 nM when "non-smellers" are excluded). This concentration of E2 is sensitive enough to detect levels of E2 that would be found in dosage forms. This paper provides evidence that scent has the potential for use in portable yeast biosensors as a readout, particularly for use in LMICs.


Asunto(s)
Técnicas Biosensibles , Preparaciones Farmacéuticas , Humanos , Saccharomyces cerevisiae/genética