Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38388721

RESUMEN

OBJECTIVE: This study analyzes the potential cost-effectiveness of integrating an artificial intelligence (AI)-assisted system into the differentiation of incidental renal lesions as benign or malignant on MR images during follow-up. MATERIALS AND METHODS: For estimation of quality-adjusted life years (QALYs) and lifetime costs, a decision model was created, including the MRI strategy and MRI + AI strategy. Model input parameters were derived from recent literature. Willingness to pay (WTP) was set to $100,000/QALY. Costs of $0 for the AI were assumed in the base-case scenario. Model uncertainty and costs of the AI system were assessed using deterministic and probabilistic sensitivity analysis. RESULTS: Average total costs were at $8054 for the MRI strategy and $7939 for additional use of an AI-based algorithm. The model yielded a cumulative effectiveness of 8.76 QALYs for the MRI strategy and of 8.77 for the MRI + AI strategy. The economically dominant strategy was MRI + AI. Deterministic and probabilistic sensitivity analysis showed high robustness of the model with the incremental cost-effectiveness ratio (ICER), which represents the incremental cost associated with one additional QALY gained, remaining below the WTP for variation of the input parameters. If increasing costs for the algorithm, the ICER of $0/QALY was exceeded at $115, and the defined WTP was exceeded at $667 for the use of the AI. CONCLUSIONS: This analysis, rooted in assumptions, suggests that the additional use of an AI-based algorithm may be a potentially cost-effective alternative in the differentiation of incidental renal lesions using MRI and needs to be confirmed in the future. CLINICAL RELEVANCE STATEMENT: These results hint at AI's the potential impact on diagnosing renal masses. While the current study urges careful interpretation, ongoing research is essential to confirm and seamlessly integrate AI into clinical practice, ensuring its efficacy in routine diagnostics. KEY POINTS: • This is a model-based study using data from literature where AI has been applied in the diagnostic workup of incidental renal lesions. • MRI + AI has the potential to be a cost-effective alternative in the differentiation of incidental renal lesions. • The additional use of AI can reduce costs in the diagnostic workup of incidental renal lesions.

2.
Pediatr Radiol ; 54(1): 58-67, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982901

RESUMEN

BACKGROUND: Though neoadjuvant chemotherapy has been widely used in the treatment of hepatoblastoma, there still lacks an effective way to predict its effect. OBJECTIVE: To characterize hepatoblastoma based on radiomics image features and identify radiomics-based lesion phenotypes by unsupervised machine learning, intended to build a classifier to predict the response to neoadjuvant chemotherapy. MATERIALS AND METHODS: In this retrospective study, we segmented the arterial phase images of 137 cases of pediatric hepatoblastoma and extracted the radiomics features using PyRadiomics. Then unsupervised k-means clustering was applied to cluster the tumors, whose result was verified by t-distributed stochastic neighbor embedding (t-SNE). The least absolute shrinkage and selection operator (LASSO) regression was used for feature selection, and the clusters were visually analyzed by radiologists. The correlations between the clusters, clinical and pathological parameters, and qualitative radiological features were analyzed. RESULTS: Hepatoblastoma was clustered into three phenotypes (homogenous type, heterogenous type, and nodulated type) based on radiomics features. The clustering results had a high correlation with response to neoadjuvant chemotherapy (P=0.02). The epithelial ratio and cystic components in radiological features were also associated with the clusters (P=0.029 and 0.008, respectively). CONCLUSIONS: This radiomics-based cluster system may have the potential to facilitate the precise treatment of hepatoblastoma. In addition, this study further demonstrated the feasibility of using unsupervised machine learning in a disease without a proper imaging classification system.


Asunto(s)
Hepatoblastoma , Neoplasias Hepáticas , Niño , Humanos , Terapia Neoadyuvante , Hepatoblastoma/diagnóstico por imagen , Hepatoblastoma/tratamiento farmacológico , Radiómica , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Fenotipo , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico
3.
J Natl Compr Canc Netw ; 21(1): 43-50.e2, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36634610

RESUMEN

BACKGROUND: Metastatic castration-resistant prostate cancer poses a therapeutic challenge with poor prognosis. The VISION trial showed prolonged progression-free and overall survival in patients treated with lutetium Lu 177 vipivotide tetraxetan (177Lu-PSMA-617) radioligand therapy compared with using the standard of care (SoC) alone. The objective of this study was to determine the cost-effectiveness of 177Lu-PSMA-617 treatment compared with SoC therapy. METHODS: A partitioned survival model was developed using data from the VISION trial, which included overall and progression-free survival and treatment regimens for 177Lu-PSMA-617 and SoC. Treatment costs, utilities for health states, and adverse events were derived from public databases and the literature. Because 177Lu-PSMA-617 was only recently approved, costs for treatment were extrapolated from 177Lu-DOTATATE. Outcome measurements included the incremental cost, effectiveness, and cost-effectiveness ratio. The analysis was performed in a US setting from a healthcare system perspective over the lifetime horizon of 60 months. The willingness-to-pay threshold was set to $50,000, $100,000, and $200,000 per quality-adjusted life years (QALYs). RESULTS: The 177Lu-PSMA-617 group was estimated to gain 0.42 incremental QALYs. Treatment using 177Lu-PSMA-617 led to an increase in costs compared with SoC ($169,110 vs $85,398). The incremental cost, effectiveness, and cost-effectiveness ratio for 177Lu-PSMA-617 therapy was $200,708/QALYs. Sensitivity analysis showed robustness of the model regarding various parameters, which remained cost-effective at all lower and upper parameter bounds. In probabilistic sensitivity analysis using Monte Carlo simulation with 10,000 iterations, therapy using 177Lu-PSMA-617 was determined as the cost-effective strategy in 37.14% of all iterations at a willingness-to-pay threshold of $200,000/QALYs. CONCLUSIONS: Treatment using 177Lu-PSMA-617 was estimated to add a notable clinical benefit over SoC alone. Based on the model results, radioligand therapy represents a treatment strategy for patients with metastatic castration-resistant prostate cancer with cost-effectiveness in certain scenarios.


Asunto(s)
Lutecio , Neoplasias de la Próstata Resistentes a la Castración , Masculino , Humanos , Lutecio/uso terapéutico , Lutecio/efectos adversos , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Análisis de Costo-Efectividad , Dipéptidos/uso terapéutico , Dipéptidos/efectos adversos , Antígeno Prostático Específico , Resultado del Tratamiento , Análisis Costo-Beneficio
4.
Eur Radiol ; 33(11): 7840-7848, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37338555

RESUMEN

OBJECTIVES: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA). METHODS: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not. Mean Hounsfield attenuation in descending aorta and PT was measured and compared. RESULTS: Overall, patients with MM showed an attenuation of 338.24 HU in the pulmonary trunk, compared to 313.71 HU in SBC (p = 0.157). In the aorta, the values for MM were lower compared to SBC (134.42 HU vs. 177.83 HU, p = 0.001). The TP-aortic ratio was significantly higher in the MM group at 3.86 compared to the SBC group at 2.26, p = 0.001. TIC phenomenon was absent in the MM group, whereas it was present in 9 patients (12.3%) in the SBC group (p = 0.005). Overall contrast was better on all levels for MM (p < 0.001). The presence of breathing artifacts was higher in the MM group (48.1% vs. 30.1%, p = 0.038), without clinical consequence. CONCLUSIONS: Performing the MM with the application of the prototype is an effective way of preventing the TIC phenomenon during i.v. contrast-enhanced CTPA scanning compared to the standard end-inspiratory breathing command. CLINICAL RELEVANCE: Compared to standard end-inspiratory breathing command, the device-assisted Mueller maneuver (MM) improves contrast enhancement and prevents the transient interruption of contrast (TIC) phenomenon in CTPA. Therefore, it may offer optimized diagnostic workup and timely treatment for patients with pulmonary embolism. KEY POINTS: • Transient interruption of contrast (TIC) may impair image quality in CTPA. • Mueller Maneuver using a device prototype could lower the rate of TIC. • Device application in clinical routine may increase diagnostic accuracy.


Asunto(s)
Embolia Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Succión , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Medios de Contraste
5.
Eur Radiol ; 33(7): 4905-4914, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36809435

RESUMEN

OBJECTIVES: Radiomics image data analysis offers promising approaches in research but has not been implemented in clinical practice yet, partly due to the instability of many parameters. The aim of this study is to evaluate the stability of radiomics analysis on phantom scans with photon-counting detector CT (PCCT). METHODS: Photon-counting CT scans of organic phantoms consisting of 4 apples, kiwis, limes, and onions each were performed at 10 mAs, 50 mAs, and 100 mAs with 120-kV tube current. The phantoms were segmented semi-automatically and original radiomics parameters were extracted. This was followed by statistical analysis including concordance correlation coefficients (CCC), intraclass correlation coefficients (ICC), as well as random forest (RF) analysis, and cluster analysis to determine the stable and important parameters. RESULTS: Seventy-three of the 104 (70%) extracted features showed excellent stability with a CCC value > 0.9 when compared in a test and retest analysis, and 68 features (65.4%) were stable compared to the original in a rescan after repositioning. Between the test scans with different mAs values, 78 (75%) features were rated with excellent stability. Eight radiomics features were identified that had an ICC value greater than 0.75 in at least 3 of 4 groups when comparing the different phantoms in a phantom group. In addition, the RF analysis identified many features that are important for distinguishing the phantom groups. CONCLUSION: Radiomics analysis using PCCT data provides high feature stability on organic phantoms, which may facilitate the implementation of radiomics analysis likewise in clinical routine. KEY POINTS: • Radiomics analysis using photon-counting computed tomography provides high feature stability. • Photon-counting computed tomography may pave the way for implementation of radiomics analysis in clinical routine.


Asunto(s)
Bosques Aleatorios , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador/métodos , Fotones
6.
BMC Med Imaging ; 23(1): 97, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-37495950

RESUMEN

BACKGROUND: Cardiovascular diseases remain the world's primary cause of death. The identification and treatment of patients at risk of cardiovascular events thus are as important as ever. Adipose tissue is a classic risk factor for cardiovascular diseases, has been linked to systemic inflammation, and is suspected to contribute to vascular calcification. To further investigate this issue, the use of texture analysis of adipose tissue using radiomics features could prove a feasible option. METHODS: In this retrospective single-center study, 55 patients (mean age 56, 34 male, 21 female) were scanned on a first-generation photon-counting CT. On axial unenhanced images, periaortic adipose tissue surrounding the thoracic descending aorta was segmented manually. For feature extraction, patients were divided into three groups, depending on coronary artery calcification (Agatston Score 0, Agatston Score 1-99, Agatston Score ≥ 100). 106 features were extracted using pyradiomics. R statistics was used for statistical analysis, calculating mean and standard deviation with Pearson correlation coefficient for feature correlation. Random Forest classification was carried out for feature selection and Boxplots and heatmaps were used for visualization. Additionally, monovariable logistic regression predicting an Agatston Score > 0 was performed, selected features were tested for multicollinearity and a 10-fold cross-validation investigated the stability of the leading feature. RESULTS: Two higher-order radiomics features, namely "glcm_ClusterProminence" and "glcm_ClusterTendency" were found to differ between patients without coronary artery calcification and those with coronary artery calcification (Agatston Score ≥ 100) through Random Forest classification. As the leading differentiating feature "glcm_ClusterProminence" was identified. CONCLUSION: Changes in periaortic adipose tissue texture seem to correlate with coronary artery calcium score, supporting a possible influence of inflammatory or fibrotic activity in perivascular adipose tissue. Radiomics features may potentially aid as corresponding biomarkers in the future.


Asunto(s)
Enfermedades Cardiovasculares , Enfermedad de la Arteria Coronaria , Humanos , Masculino , Femenino , Calcio , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen
7.
Eur J Nucl Med Mol Imaging ; 49(11): 3870-3877, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35606526

RESUMEN

BACKGROUND AND PURPOSE: Treatment of oral squamous cell carcinoma (OSCC) is based on clinical exam, biopsy, and a precise imaging-based TNM-evaluation. A high sensitivity and specificity for magnetic resonance imaging (MRI) and F-18 FDG PET/CT are reported for N-staging. Nevertheless, staging of oral squamous cell carcinoma is most often based on computed tomography (CT) scans. This study aims to evaluate cost-effectiveness of MRI and PET/CT compared to standard of care imaging in initial staging of OSCC within the US Healthcare System. METHODS: A decision model was constructed using quality-adjusted life years (QALYs) and overall costs of different imaging strategies including a CT of the head, neck, and the thorax, MRI of the neck with CT of the thorax, and whole body F-18 FDG PET/CT using Markov transition simulations for different disease states. Input parameters were derived from literature and willingness to pay (WTP) was set to US $100,000/QALY. Deterministic sensitivity analysis of diagnostic parameters and costs was performed. Monte Carlo modeling was used for probabilistic sensitivity analysis. RESULTS: In the base-case scenario, total costs were at US $239,628 for CT, US $240,001 for MRI, and US $239,131 for F-18 FDG PET/CT whereas the model yielded an effectiveness of 5.29 QALYs for CT, 5.30 QALYs for MRI, and 5.32 QALYs for F-18 FDG PET/CT respectively. F-18 FDG PET/CT was the most cost-effective strategy over MRI as well as CT, and MRI was the cost-effective strategy over CT. Deterministic and probabilistic sensitivity analysis showed high robustness of the model with incremental cost effectiveness ratio remaining below US $100,000/QALY for a wide range of variability of input parameters. CONCLUSION: F-18 FDG PET/CT is the most cost-effective strategy in the initial N-staging of OSCC when compared to MRI and CT. Despite less routine use, both whole body PET/CT and MRI are cost-effective modalities in the N-staging of OSCC. Based on these findings, the implementation of PET/CT for initial staging could be suggested to help reduce costs while increasing effectiveness in OSCC.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Neoplasias de la Boca , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Análisis Costo-Beneficio , Fluorodesoxiglucosa F18 , Neoplasias de Cabeza y Cuello/patología , Humanos , Imagen por Resonancia Magnética , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/patología , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Radiofármacos , Carcinoma de Células Escamosas de Cabeza y Cuello/patología , Tomografía Computarizada por Rayos X
8.
Eur Radiol ; 32(4): 2448-2456, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34837511

RESUMEN

OBJECTIVE: Pancreatic cancer is portrayed to become the second leading cause of cancer-related death within the next years. Potentially complicating surgical resection emphasizes the importance of an accurate TNM classification. In particular, the failure to detect features for non-resectability has profound consequences on patient outcomes and economic costs due to incorrect indication for resection. In the detection of liver metastases, contrast-enhanced MRI showed high sensitivity and specificity; however, the cost-effectiveness compared to the standard of care imaging remains unclear. The aim of this study was to analyze whether additional MRI of the liver is a cost-effective approach compared to routinely acquired contrast-enhanced computed tomography (CE-CT) in the initial staging of pancreatic cancer. METHODS: A decision model based on Markov simulation was developed to estimate the quality-adjusted life-years (QALYs) and lifetime costs of the diagnostic modalities. Model input parameters were assessed based on evidence from recent literature. The willingness-to-pay (WTP) was set to $100,000/QALY. To evaluate model uncertainty, deterministic and probabilistic sensitivity analyses were performed. RESULTS: In the base-case analysis, the model yielded a total cost of $185,597 and an effectiveness of 2.347 QALYs for CE-MR/CT and $187,601 and 2.337 QALYs for CE-CT respectively. With a net monetary benefit (NMB) of $49,133, CE-MR/CT is shown to be dominant over CE-CT with a NMB of $46,117. Deterministic and probabilistic survival analysis showed model robustness for varying input parameters. CONCLUSION: Based on our results, combined CE-MR/CT can be regarded as a cost-effective imaging strategy for the staging of pancreatic cancer. KEY POINTS: • Additional MRI of the liver for initial staging of pancreatic cancer results in lower total costs and higher effectiveness. • The economic model showed high robustness for varying input parameters.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias Pancreáticas , Análisis Costo-Beneficio , Humanos , Imagen por Resonancia Magnética/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Años de Vida Ajustados por Calidad de Vida , Tomografía Computarizada por Rayos X
9.
Eur Radiol ; 32(11): 7409-7419, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35482122

RESUMEN

OBJECTIVES: Abbreviated breast MRI (AB-MRI) was introduced to reduce both examination and image reading times and to improve cost-effectiveness of breast cancer screening. The aim of this model-based economic study was to analyze the cost-effectiveness of full protocol breast MRI (FB-MRI) vs. AB-MRI in screening women with dense breast tissue for breast cancer. METHODS: Decision analysis and a Markov model were designed to model the cumulative costs and effects of biennial screening in terms of quality-adjusted life years (QALYs) from a US healthcare system perspective. Model input parameters for a cohort of women with dense breast tissue were adopted from recent literature. The impact of varying AB-MRI costs per examination as well as specificity on the resulting cost-effectiveness was modeled within deterministic sensitivity analyses. RESULTS: At an assumed cost per examination of $ 263 for AB-MRI (84% of the cost of a FB-MRI examination), the discounted cumulative costs of both MR-based strategies accounted comparably. Reducing the costs of AB-MRI below $ 259 (82% of the cost of a FB-MRI examination, respectively), the incremental cost-effectiveness ratio of FB-MRI exceeded the willingness to pay threshold and the AB-MRI-strategy should be considered preferable in terms of cost-effectiveness. CONCLUSIONS: Our preliminary findings indicate that AB-MRI may be considered cost-effective compared to FB-MRI for screening women with dense breast tissue for breast cancer, as long as the costs per examination do not exceed 82% of the cost of a FB-MRI examination. KEY POINTS: • Cost-effectiveness of abbreviated breast MRI is affected by reductions in specificity and resulting false positive findings and increased recall rates. • Abbreviated breast MRI may be cost-effective up to a cost per examination of 82% of the cost of a full protocol examination. • Abbreviated breast MRI could be an economically preferable alternative to full protocol breast MRI in screening women with dense breast tissue.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico , Mamografía/métodos , Densidad de la Mama , Detección Precoz del Cáncer/métodos , Tamizaje Masivo , Imagen por Resonancia Magnética/métodos , Análisis Costo-Beneficio , Años de Vida Ajustados por Calidad de Vida
10.
Eur Radiol ; 32(5): 3142-3151, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34595539

RESUMEN

OBJECTIVES: To develop a pipeline for automated body composition analysis and skeletal muscle assessment with integrated quality control for large-scale application in opportunistic imaging. METHODS: First, a convolutional neural network for extraction of a single slice at the L3/L4 lumbar level was developed on CT scans of 240 patients applying the nnU-Net framework. Second, a 2D competitive dense fully convolutional U-Net for segmentation of visceral and subcutaneous adipose tissue (VAT, SAT), skeletal muscle (SM), and subsequent determination of fatty muscle fraction (FMF) was developed on single CT slices of 1143 patients. For both steps, automated quality control was integrated by a logistic regression model classifying the presence of L3/L4 and a linear regression model predicting the segmentation quality in terms of Dice score. To evaluate the performance of the entire pipeline end-to-end, body composition metrics, and FMF were compared to manual analyses including 364 patients from two centers. RESULTS: Excellent results were observed for slice extraction (z-deviation = 2.46 ± 6.20 mm) and segmentation (Dice score for SM = 0.95 ± 0.04, VAT = 0.98 ± 0.02, SAT = 0.97 ± 0.04) on the dual-center test set excluding cases with artifacts due to metallic implants. No data were excluded for end-to-end performance analyses. With a restrictive setting of the integrated segmentation quality control, 39 of 364 patients were excluded containing 8 cases with metallic implants. This setting ensured a high agreement between manual and fully automated analyses with mean relative area deviations of ΔSM = 3.3 ± 4.1%, ΔVAT = 3.0 ± 4.7%, ΔSAT = 2.7 ± 4.3%, and ΔFMF = 4.3 ± 4.4%. CONCLUSIONS: This study presents an end-to-end automated deep learning pipeline for large-scale opportunistic assessment of body composition metrics and sarcopenia biomarkers in clinical routine. KEY POINTS: • Body composition metrics and skeletal muscle quality can be opportunistically determined from routine abdominal CT scans. • A pipeline consisting of two convolutional neural networks allows an end-to-end automated analysis. • Machine-learning-based quality control ensures high agreement between manual and automatic analysis.


Asunto(s)
Sarcopenia , Composición Corporal , Humanos , Músculo Esquelético/diagnóstico por imagen , Control de Calidad , Sarcopenia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
11.
Eur Radiol ; 32(2): 1117-1126, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34455484

RESUMEN

OBJECTIVES: To investigate the cost-effectiveness of supplemental short-protocol brain MRI after negative non-contrast CT for the detection of minor strokes in emergency patients with mild and unspecific neurological symptoms. METHODS: The economic evaluation was centered around a prospective single-center diagnostic accuracy study validating the use of short-protocol brain MRI in the emergency setting. A decision-analytic Markov model distinguished the strategies "no additional imaging" and "additional short-protocol MRI" for evaluation. Minor stroke was assumed to be missed in the initial evaluation in 40% of patients without short-protocol MRI. Specialized post-stroke care with immediate secondary prophylaxis was assumed for patients with detected minor stroke. Utilities and quality-of-life measures were estimated as quality-adjusted life years (QALYs). Input parameters were obtained from the literature. The Markov model simulated a follow-up period of up to 30 years. Willingness to pay was set to $100,000 per QALY. Cost-effectiveness was calculated and deterministic and probabilistic sensitivity analysis was performed. RESULTS: Additional short-protocol MRI was the dominant strategy with overall costs of $26,304 (CT only: $27,109). Cumulative calculated effectiveness in the CT-only group was 14.25 QALYs (short-protocol MRI group: 14.31 QALYs). In the deterministic sensitivity analysis, additional short-protocol MRI remained the dominant strategy in all investigated ranges. Probabilistic sensitivity analysis results from the base case analysis were confirmed, and additional short-protocol MRI resulted in lower costs and higher effectiveness. CONCLUSION: Additional short-protocol MRI in emergency patients with mild and unspecific neurological symptoms enables timely secondary prophylaxis through detection of minor strokes, resulting in lower costs and higher cumulative QALYs. KEY POINTS: • Short-protocol brain MRI after negative head CT in selected emergency patients with mild and unspecific neurological symptoms allows for timely detection of minor strokes. • This strategy supports clinical decision-making with regard to immediate initiation of secondary prophylactic treatment, potentially preventing subsequent major strokes with associated high costs and reduced QALY. • According to the Markov model, additional short-protocol MRI remained the dominant strategy over wide variations of input parameters, even when assuming disproportionally high costs of the supplemental MRI scan.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Encéfalo/diagnóstico por imagen , Análisis Costo-Beneficio , Humanos , Estudios Prospectivos , Años de Vida Ajustados por Calidad de Vida
12.
Clin Chem Lab Med ; 60(6): 821-829, 2022 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-35218176

RESUMEN

Disruptive imaging and laboratory technologies can improve clinical decision processes and outcomes in oncology. However, certain obstacles must be overcome before these technologies can be fully implemented as part of the standard for care. An integrative diagnostic approach represents a unique opportunity to unleash the full diagnostic potential and paves the way towards personalized cancer diagnostics. To meet this demand, an interdisciplinary Task Force of the EFLM was initiated as a consequence of an EFLM/ESR during the CELME 2019 meeting in order to evaluate the clinical value of CNAPS/CTC (circulating nucleic acids in plasma and serum/circulating tumor cells) in early detection of cancer. Here, an overview of current disruptive techniques, their clinical implications and potential value of an integrative diagnostic approach is provided. Furthermore, requirements such as the establishment of diagnostic tumor boards, development of adequate software solutions and a change of mindset towards a new generation of diagnosticians providing actionable health information are presented. This development has the potential to elevate the position and clinical recognition of diagnosticians.


Asunto(s)
Detección Precoz del Cáncer , Células Neoplásicas Circulantes , Biomarcadores de Tumor , Humanos , Células Neoplásicas Circulantes/patología
13.
J Vasc Surg ; 73(1): 232-239.e2, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32442612

RESUMEN

OBJECTIVE: Follow-up after endovascular aneurysm repair is necessary to detect potentially life-threatening complications such as endoleaks. Computed tomography angiography (CTA) or magnetic resonance angiography (MRA) is often used as standard of care for follow-up. Contrast-enhanced ultrasound (CEUS) has been shown to be a viable and fast real-time nonionizing imaging modality with equivalent diagnostic accuracy while also being superior to color Doppler ultrasound. The aim of this cost-utility analysis was to evaluate the cost-effectiveness of this imaging method in comparison to others for the evaluation of endoleaks requiring treatment. METHODS: A decision model based on Markov simulations estimated lifetime costs and quality-adjusted life years (QALYs) associated with CTA, MRA, CEUS, and color Doppler ultrasound. Model input parameters were obtained from recent literature. The applied sensitivity and specificity values amounted to 90.5% and 100.0% for CTA, 96.0% and 100.0% for MRA, 94.0% and 95.0% for CEUS, and 82.0% and 93.0% for color Doppler ultrasound. Probabilistic and deterministic sensitivity analysis was performed to estimate uncertainty of model results. To evaluate cost-effectiveness, incremental cost-effectiveness ratios were reported as a measure representing the economic value of a strategy compared with an alternative. The willingness to pay was set to $100,000/QALY. RESULTS: In the base-case scenario for a willingness to pay of $100,000 per QALY, CEUS was the most cost-effective of the four diagnostic strategies with estimated costs of $17,383 and effectiveness of 9.770 QALYs. CTA was estimated to result in lifetime costs of $17,679 with an expected effectiveness of 9.768 QALYs, whereas color Doppler ultrasound showed expected costs of $17,287 with 9.763 QALYs. Expected costs and effectiveness of MRA amounted to $17,945 and 9.771 QALYs each. Base-case estimates of the incremental cost-effectiveness ratios for CEUS vs color Doppler ultrasound equaled $14,173.52/QALY. CONCLUSIONS: CEUS is a cost-effective imaging method for the evaluation of therapy-requiring endoleaks in endovascular aneurysm repair surveillance.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Endofuga/diagnóstico , Procedimientos Endovasculares/efectos adversos , Ultrasonografía Doppler en Color/economía , Adulto , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada/economía , Análisis Costo-Beneficio , Endofuga/economía , Endofuga/terapia , Femenino , Humanos , Angiografía por Resonancia Magnética/economía , Masculino , Persona de Mediana Edad , Reoperación/economía
14.
Eur J Nucl Med Mol Imaging ; 48(10): 3268-3276, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33686457

RESUMEN

PURPOSE: Rectal cancer is one of the most frequent causes of cancer-related morbidity and mortality in the world. Correct identification of the TNM state in primary staging of rectal cancer has critical implications on patient management. Initial evaluations revealed a high sensitivity and specificity for whole-body PET/MRI in the detection of metastases allowing for metastasis-directed therapy regimens. Nevertheless, its cost-effectiveness compared with that of standard-of-care imaging (SCI) using pelvic MRI + chest and abdominopelvic CT is yet to be investigated. Therefore, the aim of this study was to analyze the cost-effectiveness of whole-body 18F FDG PET/MRI as an alternative imaging method to standard diagnostic workup for initial staging of rectal cancer. METHODS: For estimation of quality-adjusted life years (QALYs) and lifetime costs of diagnostic modalities, a decision model including whole-body 18F FDG PET/MRI with a hepatocyte-specific contrast agent and pelvic MRI + chest and abdominopelvic CT was created based on Markov simulations. For obtaining model input parameters, review of recent literature was performed. Willingness to pay (WTP) was set to $100,000/QALY. Deterministic sensitivity analysis of diagnostic parameters and costs was applied, and probabilistic sensitivity was determined using Monte Carlo modeling. RESULTS: In the base-case scenario, the strategy whole-body 18F FDG PET/MRI resulted in total costs of $52,186 whereas total costs of SCI were at $51,672. Whole-body 18F FDG PET/MRI resulted in an expected effectiveness of 3.542 QALYs versus 3.535 QALYs for SCI. This resulted in an incremental cost-effectiveness ratio of $70,291 per QALY for PET/MRI. Thus, from an economic point of view, whole-body 18F FDG PET/MRI was identified as an adequate diagnostic alternative to SCI with high robustness of results to variation of input parameters. CONCLUSION: Based on the results of the analysis, use of whole-body 18F FDG PET/MRI was identified as a feasible diagnostic strategy for initial staging of rectal cancer from a cost-effectiveness perspective.


Asunto(s)
Fluorodesoxiglucosa F18 , Neoplasias del Recto , Medios de Contraste , Análisis Costo-Beneficio , Hepatocitos/patología , Humanos , Imagen por Resonancia Magnética , Estadificación de Neoplasias , Tomografía de Emisión de Positrones , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/patología , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
15.
Eur Radiol ; 31(2): 967-974, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32856166

RESUMEN

OBJECTIVES: To evaluate the economic implications of our previous study on the use of MR-mammography (MRM) as a solitary imaging tool in women at intermediate risk due to dense breasts. BACKGROUND: In our previous study, we found MRM to be a specific diagnostic tool with high accuracy in patients with dense breasts representing a patient collective at intermediate risk of breast cancer. For this study, we examined whether MRM is an economical alternative. METHODS: For the determination of outcomes and costs, a decision model based on potential diagnostic results of MRM was developed. Quality of life was estimated in a Markov chain model distinguishing between the absence of malignancy, the presence of malignancy, and death. Input parameters were utilized from the prospective TK-Study. To investigate the economic impact of MRM, overall costs in € and outcomes of MRM in quality-adjusted life years (QALYs) were estimated. A deterministic sensitivity analysis was performed. RESULTS: MRM was associated with expected costs of 1650.48 € in the 5-year period and an expected cumulative outcome of 4.69 QALYs. A true positive diagnosis resulted in significantly lower costs and a higher quality of life when compared to the consequences of a false negative result. In the deterministic sensitivity analysis, treatment costs had more impact on overall costs than the costs of MRM. The total costs per patient remained below 2500 € in the 5-year period. CONCLUSION: MRM, as a solitary imaging tool in patients at intermediate risk due to dense breasts, is economically feasible. KEY POINTS: • In patients with dense breasts (i.e., patients at intermediate risk of breast cancer), the relative cost of MR-mammography examinations only had moderate impact on overall costs. • This is due to cost-savings through the application of a sensitive imaging technique resulting in an optimized staging and therapy planning. • MR-mammography, unaccompanied by mammography or ultrasound in patients with dense breasts, was economically feasible in our analysis.


Asunto(s)
Neoplasias de la Mama , Mamografía , Densidad de la Mama , Neoplasias de la Mama/diagnóstico por imagen , Análisis Costo-Beneficio , Femenino , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos , Calidad de Vida , Sensibilidad y Especificidad
16.
Eur Radiol ; 31(2): 834-846, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32851450

RESUMEN

OBJECTIVES: To investigate the prediction of 1-year survival (1-YS) in patients with metastatic colorectal cancer with use of a systematic comparative analysis of quantitative imaging biomarkers (QIBs) based on the geometric and radiomics analysis of whole liver tumor burden (WLTB) in comparison to predictions based on the tumor burden score (TBS), WLTB volume alone, and a clinical model. METHODS: A total of 103 patients (mean age: 61.0 ± 11.2 years) with colorectal liver metastases were analyzed in this retrospective study. Automatic segmentations of WLTB from baseline contrast-enhanced CT images were used. Established biomarkers as well as a standard radiomics model building were used to derive 3 prognostic models. The benefits of a geometric metastatic spread (GMS) model, the Aerts radiomics prior model of the WLTB, and the performance of TBS and WLTB volume alone were assessed. All models were analyzed in both statistical and predictive machine learning settings in terms of AUC. RESULTS: TBS showed the best discriminative performance in a statistical setting to discriminate 1-YS (AUC = 0.70, CI: [0.56, 0.90]). For the machine learning-based prediction for unseen patients, both a model of the GMS of WLTB (0.73, CI: [0.60, 0.84]) and the Aerts radiomics prior model (0.76, CI: [0.65, 0.86]) applied on the WLTB showed a numerically higher predictive performance than TBS (0.68, CI: [0.54, 0.79]), radiomics (0.65, CI: [0.55, 0.78]), WLTB volume alone (0.53, CI: [0.40. 0.66]), or the clinical model (0.56, CI: [0.43, 0.67]). CONCLUSIONS: The imaging-based GMS model may be a first step towards a more fine-grained machine learning extension of the TBS concept for risk stratification in mCRC patients without the vulnerability to technical variance of radiomics. KEY POINTS: • CT-based geometric distribution and radiomics analysis of whole liver tumor burden in metastatic colorectal cancer patients yield prognostic information. • Differences in survival are possibly attributable to the spatial distribution of metastatic lesions and the geometric metastatic spread analysis of all liver metastases may serve as robust imaging biomarker invariant to technical variation. • Imaging-based prediction models outperform clinical models for 1-year survival prediction in metastatic colorectal cancer patients with liver metastases.


Asunto(s)
Neoplasias , Tomografía Computarizada por Rayos X , Anciano , Humanos , Hígado , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Carga Tumoral
17.
Medicina (Kaunas) ; 57(1)2021 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-33435420

RESUMEN

Background and Objectives: Vesicoureteral reflux (VUR) describes a common pediatric anomaly in pediatric urology with a prevalence of 1-2%. In diagnostics, in addition to the gold standard of voiding cystourethrography (VCUG), contrast-enhanced urosonography (ceVUS) offers a radiation-free procedure, which, despite its advantages, is not yet widely used. In the present single-center study, subsequent therapeutic procedures and outcomes after ceVUS of 49 patients were investigated. The aim of the study is to investigate the efficacy of ceVUS with the intention of broader clinical implementation. Materials and Methods: Between 2016 and 2020, 49 patients were retrospectively included and received a ceVUS to evaluate VUR. With a distribution of 47:2 (95.9%), a clear female predominance was present. The age of the patients varied between 5 months and 60 years at the time of ceVUS. All examinations were all performed and subsequently interpreted by a single experienced radiologist (EFSUMB level 3). Results: Compared to intraoperative findings, ceVUS shows a sensitivity of 95.7% with a specificity of 100%. Allergic reactions to the contrast medium could not be observed. Conclusion: With its high sensitivity and intraoperative validation, ceVUS offers an excellent alternative to VCUG, the gold standard in the diagnosis of VUR. In addition, ceVUS is a radiation-free examination method with a low risk profile that offers an exceptional diagnostic tool in the diagnostic clarification of recurrent urinary tract infections with the suspected diagnosis of VUR and should also be included in the consideration of a diagnosis next to the established VCUG, especially in younger children.


Asunto(s)
Medios de Contraste , Técnicas de Diagnóstico Urológico , Ultrasonografía/métodos , Reflujo Vesicoureteral/diagnóstico por imagen , Adolescente , Adulto , Antibacterianos/uso terapéutico , Niño , Preescolar , Cistografía , Femenino , Humanos , Lactante , Inyecciones , Laparoscopía , Masculino , Persona de Mediana Edad , Fosfolípidos , Politetrafluoroetileno , Exposición a la Radiación , Recurrencia , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Hexafluoruro de Azufre , Ureteroscopía , Uretra/diagnóstico por imagen , Vejiga Urinaria/diagnóstico por imagen , Infecciones Urinarias/etiología , Infecciones Urinarias/prevención & control , Urografía , Reflujo Vesicoureteral/clasificación , Reflujo Vesicoureteral/complicaciones , Reflujo Vesicoureteral/terapia , Adulto Joven
18.
Medicina (Kaunas) ; 57(10)2021 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-34684099

RESUMEN

Background and Objectives: Preoperative planning utilizing computed tomographies (CT) is of utmost importance in functional endoscopic sinus surgery (FESS). Frequently, no uniform documentation and planning structures are available to residents in training. Consequently, overall completeness and quality of operation planning may vary greatly. The objective of the present study was to evaluate the impact of a structured operation planning (SOP) approach on the report quality and user convenience during a 4-day sinus surgery course. Materials and Methods: Fifteen participant were requested to plan a FESS procedure based on a CT scan of the paranasal sinuses that exhibited common pathological features, in a conventional manner, using a free text. Afterwards, the participants reevaluated the same scans by means of a specifically designed structured reporting template. Two experienced ENT surgeons assessed the collected conventional operation planning (COP) and SOP methods independently with regard to time requirements, overall quality, and legibility. User convenience data were collected by utilizing visual analogue scales. Results: A significantly greater time expenditure was associated with SOPs (183 s vs. 297 s, p = 0.0003). Yet, legibility (100% vs. 72%, p < 0.0001) and overall completeness (61.3% vs. 22.7%, p < 0.0001) of SOPs was significantly superior to COPs. Additionally, description of highly relevant variants in anatomy and pathologies were outlined in greater detail. User convenience data delineated a significant preference for SOPs (VAS 7.9 vs. 6.9, p = 0.0185). Conclusions: CT-based planning of FESS procedures by residents in training using a structured approach is more time-consuming while producing a superior report quality in terms of detailedness and readability. Consequently, SOP can be considered as a valuable tool in the process of preoperative evaluations, especially within residency.


Asunto(s)
Internado y Residencia , Senos Paranasales , Humanos , Senos Paranasales/diagnóstico por imagen , Senos Paranasales/cirugía , Cuidados Preoperatorios , Tomografía Computarizada por Rayos X
19.
Eur Radiol ; 30(2): 866-876, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31691123

RESUMEN

OBJECTIVES: To evaluate the diagnostic value of a contrast-enhanced 3D T1-weighted-modified volumetric isotropic turbo spin-echo acquisition sequence (T1-mVISTA) in comparison with a conventional 3D T1-weighted magnetization-prepared rapid gradient-echo (T1-MP-RAGE) sequence for the detection of meningeal enhancement in patients with meningitis. METHODS: Thirty patients (infectious meningitis, n = 12; neoplastic meningitis, n = 18) and 45 matched controls were enrolled in this retrospective case-control study. Sets of randomly selected T1-mVISTA and T1-MP-RAGE images (both with 0.8-mm isotropic resolution) were read separately 4 weeks apart. Image quality, leptomeningeal and dural enhancement, grading of visual contrast enhancement, and diagnostic confidence were compared using the Kruskal-Wallis rank sum test. RESULTS: Image quality was rated to be good to excellent in 75 out of 75 cases (100%) for T1-mVISTA and 74 out of 75 cases (98.7%) for T1-MP-RAGE. T1-mVISTA detected significantly more patients with leptomeningeal enhancement (p = 0.006) compared with T1-MP-RAGE (86.7 vs. 50.0%, p < 0.001), each with specificity of 100%. Similarly, sensitivity of T1-mVISTA for the detection of dural and/or leptomeningeal enhancement was also significantly higher compared with that of T1-MP-RAGE (96.7 vs. 80.0%, p = 0.025) without significant differences regarding specificity (97.8 vs. 95.6%, p = 0.317). No significant differences were found for dural enhancement alone. Diagnostic confidence in T1-mVISTA was significantly higher (p = 0.01). Visual contrast enhancement was tendentially higher in T1-mVISTA. CONCLUSIONS: T1-mVISTA may be an adequate and probably better alternative to T1-MP-RAGE for detection of leptomeningeal diseases. KEY POINTS: • Black-blood T1-mVISTA showed a significant higher sensitivity for the detection of leptomeningeal enhancement compared with MP-RAGE without losses regarding specificity. • Diagnostic confidence was assessed significantly higher in T1-mVISTA. • T1-mVISTA should be considered a supplement or an alternative to T1-MP-RAGE in patients with suspected leptomeningeal diseases.


Asunto(s)
Neoplasias Meníngeas/diagnóstico por imagen , Meningitis/diagnóstico por imagen , Adolescente , Adulto , Estudios de Casos y Controles , Niño , Preescolar , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Imagenología Tridimensional/métodos , Lactante , Imagen por Resonancia Magnética/métodos , Masculino , Neoplasias Meníngeas/secundario , Meningitis Bacterianas/diagnóstico por imagen , Meningitis Viral/diagnóstico por imagen , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
20.
Pediatr Radiol ; 50(8): 1078-1082, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32415324

RESUMEN

BACKGROUND: One main challenge in pediatric imaging is to reduce motion artifacts by calming young patients. To that end, the Radiological Society of North America (RSNA) as early as 1997 stated the necessity of adults accompanying their child during the child's examination. Nonetheless, current research lacks data regarding radiation dose to these chaperones. OBJECTIVE: The aim of this study was to measure the radiation dose of accompanying adults during state-of-the-art pediatric CT protocols. MATERIALS AND METHODS: In addition to a 100-kV non-contrast-enhanced chest CT (Protocol 1), we performed a 70-kV contrast-enhanced chest protocol (Protocol 2) using a third-generation dual-source CT. We acquired data on the radiation dose around the scanner using digital dosimetry placed right at the gantry, 1 m away, as well as beside the gantry. We acquired the CT-surrounding radiation dose during scanning of a pediatric phantom as well as 12 pediatric patients. RESULTS: After conducting 10 consecutive phantom scans using Protocol 1, we found the location with the highest cumulative dose acquired was right next to the gantry opening, at 3 µSv. Protocol 2 showed highest cumulative dose of 2 µSv at the same location. For Protocol 1, the location with the highest radiation doses during pediatric scans was right next to the gantry opening, with doses of 0.75±0.70 µSv. For Protocol 2, the highest radiation was measured 1 m away at 0.50±0.60 µSv. No radiation dose was measured at any time beside the gantry. CONCLUSION: Our results provide proof that chaperones receive low radiation doses during state-of-the-art CT examinations. Given knowledge of these values as well as the optimal spots with the lowest radiation doses, parents as well as patients might be more relaxed during the examination.


Asunto(s)
Chaperones Médicos , Dosis de Radiación , Tomografía Computarizada por Rayos X , Adulto , Niño , Medios de Contraste , Femenino , Humanos , Masculino , Fantasmas de Imagen , Monitoreo de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA