Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Anat ; 32(2): 272-276, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30300460

RESUMEN

To examine the origin and development of the renal plexus and its relationship to the renal vessels in embryos and early human fetuses. Serial sections of 34 human embryos (stages 16 to 23 of Carnegie, 4 or 5-8 weeks) and 38 fetuses (9-19 weeks) were analyzed. Throughout the embryonic period, the kidney was not innervated by the renal plexus. Those nerves appeared at the beginning of the early fetal period (9 weeks) as branches given off by the immature autonomic abdominal plexus. The renal nerves started to approach to the kidney during the early fetal period at 9-10 weeks of development. They were distributed in close proximity to the renal arteries and their branches. They were observed first with the settlement of the renal veins. The renal artery is present as a branch of the abdominal aorta at stage 19 (between 6 and 7 weeks) prior to development of the renal plexus. The renal veins were not present during the embryonic period but appeared at the start of the fetal period, along with the renal nerves that emerged from segmented sympathetic para-aortic bodies (SPBs). Clin. Anat. 32:272-276, 2019. © 2018 Wiley Periodicals, Inc.


Asunto(s)
Desarrollo Fetal/fisiología , Riñón/embriología , Riñón/inervación , Arteria Renal/embriología , Ganglios/anatomía & histología , Ganglios/fisiología , Edad Gestacional , Humanos
2.
J Radiol Prot ; 37(2): 450-458, 2017 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-28586317

RESUMEN

OBJECTIVES: The aim of this study was to analyze the operator radiation exposure (ORE) and the image quality in a coronary angiography (CA) of the standard left lateral view (LLV) and compare it with an alternative right lateral view (RLV). BACKGROUND: Interventional cardiologists are exposed to high doses of scatter radiation, especially in angulated projections. METHODS: We prospectively included consecutive patients who underwent diagnostic CA. A standard +90° LLV and an alternative RLV (-90°) were done in each patient with the same protocol. The operator effective dose rate (mSv/h) was determined for each projection with digital dosimeters located in the collar, waist and knee. The image quality of both the LLV and RLV was analyzed and compared to a standard projection. RESULTS: 116 patients were enrolled; left coronary artery (LCA) was assessed in 52 patients and right coronary artery (RCA) in 64 patients. The ORE was significantly lower with the RLV compared to the conventional LLV with a maximum ORE reduction of 91.5% in the operator waist (LLV: 6.84 mSv h-1 versus RLV: 0.58 mSv h-1, p < 0.001). No significant differences in image quality were observed for the RCA in both projections. For the LCA, a slight loss of quality was observed with the RLV. CONCLUSIONS: -90° RLV is associated with a significant decrease in ORE compared to the conventional +90° LLV without losing image resolution for the RCA and resulting in a slight quality loss for the LCA evaluation. The RLV should be the first choice for RCA evaluation. For the LCA, the RLV loss of resolution should be balanced with the benefit of minimizing ORE, mainly in cases with long fluoroscopy times, such as complex percutaneous coronary interventional procedures.


Asunto(s)
Angiografía Coronaria/métodos , Antebrazo/efectos de la radiación , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Radiografía Intervencional/métodos , Anciano , Femenino , Humanos , Masculino , Estudios Prospectivos , Dosis de Radiación , Protección Radiológica/métodos , Radiometría/métodos , Dispersión de Radiación
3.
Clin Anat ; 29(5): 660-4, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27090982

RESUMEN

Catheter-based renal denervation techniques focus on reducing blood pressure in resistant hypertension. This procedure requires exact knowledge of the anatomical interrelation between the renal arteries and the targeted renal nervous plexus. The aim of this work was to build on classical anatomical studies and describe the gross anatomy and anatomical relationships of the renal arteries and nerve supply to the kidneys in a sample of human cadavers. Twelve human cadavers (six males and six females), age range 73 to 94 years, were dissected. The nervous fibers and renal arteries were dissected using a surgical microscope. The renal plexus along the hilar renal artery comprised a fiber-ganglionic ring surrounding the proximal third of the renal artery, a neural network along the middle and distal thirds, and smaller accessory ganglia along the course of the nerve fibers. The fibers of the neural network were mainly located on the superior (95.83%) and inferior (91.66%) surfaces of the renal artery and they were sparsely interconnected by diagonal fibers. Polar arteries were present in 33.33% of cases and the renal nerve pattern for these was similar to that of the hilar arteries. Effective renal denervation needs to target the superior and inferior surfaces of the hilar and polar arteries, where the fibers of the neural network are present. Clin. Anat. 29:660-664, 2016. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Ganglios Simpáticos/anatomía & histología , Riñón/inervación , Arteria Renal/anatomía & histología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino
4.
J Cardiovasc Dev Dis ; 11(7)2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-39057620

RESUMEN

Optical Coherence Tomography (OCT) imaging is a valuable tool for complex coronary interventions. While complications are rare, the occurrence of ventricular arrhythmias during its use is one of the most feared. Unfortunately, the mechanism by which these arrhythmias arise remains unclear. We describe the case of a patient under continuous electrocardiographic (ECG) monitoring who experienced ventricular fibrillation during an OCT procedure. A detailed analysis of the ECG event sequence was performed, from the administration of the contrast medium to the onset of ventricular fibrillation. Utilizing the collected data, we examined potential precipitating factors based on the observed alterations in the electrocardiogram. A comprehensive understanding of the mechanisms underlying these arrhythmias is crucial for the development of preventive measures that avoid such incidents in the future.

5.
Cardiovasc Diagn Ther ; 13(5): 792-804, 2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37941845

RESUMEN

Background: Drug-eluting stents (DES) are considered the therapy of choice in ST-segment elevation myocardial infarction (STEMI); however, a low persistent rate of revascularizations and stent thrombosis exist over the time. We have previously shown that a paclitaxel (PTX)-drug-coated balloon (DCB) after a bare-metal stent (BMS) implantation (DCB-combined strategy) yields superior angiographic and clinical results compared to BMS in the short term. However, the long-term safety and efficacy of this approach remain uncertain. Methods: An 8-year clinical follow-up was conducted on patients enrolled in the randomized PEBSI-1 trial (NCT01839890). The original trial included patients who suffered a STEMI, patients were randomly assigned to receive a DCB-combined strategy or BMS only and the primary endpoint was in-stent late luminal loss (LLL) at 9-month follow-up. After the completion of this study, death, myocardial re-infarction, ischemia-driven repeated revascularizations included target lesion revascularization (TLR) and target vessel revascularization (TVR), and stent thrombosis, were assessed by yearly contact by a clinical visit, telephone or by electronic records. These outcomes were adhered to ARC-2 criteria. Results: The rate of incomplete follow-up was very low, with only 3 out of 111 patients (2.7%) in the DCB-combined strategy group and 1 out of 112 patients (0.9%) in the BMS group. At 8 years there were a lower rate of TVR [3.7% vs. 14.3%; hazard ratio (HR): 0.243; 95% confidence interval (CI): 0.081-0.727; P=0.006], and a trend towards lower TLR (2.8% vs. 8.9%; HR: 0.300; 95% CI: 0.083-1.090; P=0.052) in the DCB-combined strategy group. No statistical difference between the DCB-combined strategy and BMS groups were found for all causes of death, deaths from cardiovascular disease, reinfarctions or stent thrombosis. Notably in the DCB-combined strategy group, no episode of stent thrombosis occurred after the first year. Similarly, there were no cardiovascular deaths, TVR and TLR in the DCB-combined strategy group after 5 years. In contrast, during the period from year 5 to 8, the BMS group experienced an additional cardiovascular death, as well as one case of TVR, one case of TLR, and one case of stent thrombosis. Conclusions: In STEMI patients, the DCB-combined strategy maintains its safety and clinical efficacy over time. Our rates of TVR, TLR, and very late stent thrombosis (VLST) at very long-term are the lowest ever found in a STEMI trial. Further studies are warranted to assess the potential superiority of this novel strategy as compared with new-generation DES to prevent very late events in these patients. Trial Registration: ClinicalTrials.gov; identifier: NCT01839890.

6.
Coron Artery Dis ; 32(8): 673-680, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33826537

RESUMEN

OBJECTIVES: Drug-coated balloons (DCBs) have theoretical advantages over drug-eluting stents (DESs) to facilitate stent healing. We studied whether, in patients undergoing primary coronary interventions (pPCIs), a strategy of DCB after bare-metal stent improves early healing as determined by optical coherence tomography (OCT) compared with new-generation DES. METHODS: pPCI patients were randomized (1:1) to treatment with new-generation sirolimus-eluting stents (DES group) or DCB-strategy. Vessel healing was assessed by OCT at 90 days. RESULTS: Fifty-three patients were randomized (26 DES vs. 27 DCB). At 90 days, both strategies showed a low rate of uncovered struts (3.2 vs. 3.2%, P = 0.64) and a very high and similar rate of covered and apposed struts (96.6 vs. 96.1%, respectively; P = 0.58). However, DCB group had a significantly lower rate of major coronary evaginations (68 vs. 37%, P = 0.026), and more frequently developed a thin homogeneous neointimal layer (20 vs. 70.4%, P = 0.001) suggesting distinct superior healing at 3 months compared to DES. CONCLUSIONS: In pPCI both, sirolimus-DES and DCB-strategy, provide excellent strut coverage at 3 months. However, DCB ensures more advanced and optimal stent healing compared to sirolimus-DES. Further research is needed to determine whether, in patients undergoing pPCI, DCB offers superior long-term clinical and angiographic outcomes than new-generation DES (NCT03610347).


Asunto(s)
Stents Liberadores de Fármacos/normas , Infarto del Miocardio con Elevación del ST/fisiopatología , Anciano , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/estadística & datos numéricos , Infarto del Miocardio con Elevación del ST/complicaciones , Sirolimus/farmacología , Sirolimus/uso terapéutico , Tomografía de Coherencia Óptica/métodos , Tomografía de Coherencia Óptica/estadística & datos numéricos , Resultado del Tratamiento
7.
Cardiovasc Revasc Med ; 29: 22-28, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32859538

RESUMEN

BACKGROUND/PURPOSE: The main indication of covered stents (CS) is coronary artery perforation (CAP), but, they have been increasingly used in other scenarios. Data on the long-term follow-up of CS is limited, and no studies have been conducted specifically using new-generation polyurethane-covered cobalt-chromium Papyrus CS. PURPOSE: to evaluate the clinical outcomes after hospital discharge of Papyrus CS and to compare their outcome after implantation in CAP or coronary artery aneurysms (CAA). METHODS/MATERIALS: We evaluated the baseline clinical characteristics, lesion subsets, procedural features and the outcomes after initial discharge of Papyrus CS implanted in 17 high-PCI-volume centers. RESULTS: 127 Papyrus CS were implanted in 108 patients (68 ±â€¯1 years; 82.8% male) admitted for stable coronary disease (32.3%), NSTEMI (42.4%) or STEMI (25.3%). The number of CS per patient was 1.2 ±â€¯0.6 (diameter: 3.5 ±â€¯1.7 mm; length: 18.5 ±â€¯3.7 mm). Angiographic success rate was 96%. CS diameter was larger in CAA (CAP:3.04 ±â€¯0.5 mm vs CAA:4.1 ±â€¯2.7 mm; p = .022). Intracoronary imaging techniques were used more frequently in CAA (p < .0001). After a mean follow-up of 22 ±â€¯16 months, the major cardiovascular adverse events (MACE) rate was 7.1% [cardiac death: 2%, Myocardial infarction: 5%, Target Lesion Revascularization: 5% and Stent Thrombosis (ST): 3%]. MACE rate was similar in CAP (7.7%) and CAA (7.1%) (p = .9). However, CAA showed a higher ST rate (CAP: 0% vs CA: 7.1%; p = .04). CONCLUSION: After hospital discharge, clinical outcomes after Papyrus CS implantation are acceptable (considering the clinical scenario and compared with other treatment alternatives) with no significant differences in the MACE rate between those implanted in CAA or in CAP. However, CAA group showed a higher ST rate.


Asunto(s)
Intervención Coronaria Percutánea , Poliuretanos , Cromo , Cobalto , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Femenino , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , España/epidemiología , Stents , Resultado del Tratamiento
8.
Atherosclerosis ; 332: 48-54, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34391035

RESUMEN

BACKGROUND AND AIMS: SARS-Cov-2 predisposes patients to thrombotic complications, due to excessive inflammation, endothelial dysfunction, platelet activation, and coagulation/fibrinolysis disturbances. The aim of the present study was to evaluate clinical characteristics and prognostic impact of SARS-CoV-2 positivity among STEMI patients undergoing primary percutaneous coronary intervention (PPCI). METHODS: We selected SARS-CoV-2 positive patients included in the ISACS-STEMI COVID-19, a retrospective multicenter European registry including 6609 STEMI patients treated with PPCI from March 1st until April 30th, in 2019 and 2020. As a reference group, we randomly sampled 5 SARS-Cov-2 negative patients per each SARS-CoV-2 positive patient, individually matched for age, sex, and hospital/geographic area. Study endpoints were in-hospital mortality, definite stent thrombosis, heart failure. RESULTS: Our population is represented by 62 positive SARS-CoV-2 positive patients who were compared with a matched population of 310 STEMI patients. No significant difference was observed in baseline characteristics or the modality of access to the PCI center. In the SARS-CoV-2 positive patients, the culprit lesion was more often located in the RCA (p < 0.001). Despite similar pre and postprocedural TIMI flow, we observed a trend in higher use of GP IIb-IIIa inhibitors and a significantly higher use of thrombectomy in the SARS-CoV-2 positive patients. SARS-CoV-2 positivity was associated with a remarkably higher in hospital mortality (29% vs 5.5%, p < 0.001), definite in-stent thrombosis (8.1% vs 1.6%, p = 0.004) and heart failure (22.6% vs 10.6%, p = 0.001) that was confirmed after adjustment for confounding factors. CONCLUSIONS: Our study showed that among STEMI patients, SARS-CoV-2 positivity is associated with larger thrombus burden, a remarkably higher mortality but also higher rates of in-stent thrombosis and heart failure.


Asunto(s)
COVID-19 , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Intervención Coronaria Percutánea/efectos adversos , Sistema de Registros , Reperfusión , Estudios Retrospectivos , SARS-CoV-2 , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/cirugía , Resultado del Tratamiento
9.
Coron Artery Dis ; 32(2): 96-104, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32558692

RESUMEN

BACKGROUND: Currently drug-eluting stents (DES) and drug-eluting balloons are recommended in patients with in-stent restenosis (ISR). However, the efficacy of bioresorbable vascular scaffolds (BVS) after scoring balloon (SCB) predilation in these patients is unknown. METHODS: RIBS VI (NCT02672878) and RIBS VI 'Scoring' (NCT03069066) are prospective multicentre studies assessing the value of BVS in patients with ISR. Inclusion and exclusion criteria were identical in both studies. Results of conventional BVS implantation (112 patients) were compared with those obtained with systematic SCB therapy before BVS (108 patients). Angiographic follow-up was scheduled for all patients. RESULTS: On late angiography (93% of eligible patients) the in-segment minimal lumen diameter (primary end-point) (1.88 ± 0.5 vs. 1.90 ± 0.4 mm, P = 0.81), % diameter stenosis (28 ± 17 vs. 29 ± 15%), late lumen loss (0.23 ± 0.4 vs. 0.22 ± 0.4 mm) and binary restenosis rate (8.5 vs. 9.3%) were similar in the conventional BVS and SCB + BVS groups, respectively. At 1-year follow-up (100% of patients) target lesion revascularization (TLR) requirement (9.8 vs. 11.1%) was similar with the two strategies. Freedom from cardiac death, myocardial infarction and TLR was 88% and 87%, respectively. Results remained unchanged after adjusting for potential baseline confounders and were consistent in 10 prespecified subgroups. CONCLUSION: This study suggests that results of conventional BVS implantation in patients with ISR are not improved by systematic predilation with SCB. ClinicalTrials.gov ID: NCT02672878 (RIBS VI) and NCT03069066 (RIBS VI 'Scoring').


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón , Implantación de Prótesis Vascular , Reestenosis Coronaria/terapia , Anciano , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Estudios Prospectivos , España , Stents , Andamios del Tejido
10.
Hypertension ; 76(4): 1240-1246, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32829660

RESUMEN

Despite the use of renal denervation to treat hypertension, the anatomy of the renal nervous system remains poorly understood. We performed a detailed quantitative analysis of the human renal nervous system anatomy with the goal of optimizing renal denervation procedural safety and efficacy. Sixty kidneys from 30 human cadavers were systematically microdissected to quantify anatomic variations in renal nerve patterns. Contrary to current clinical perception, not all renal innervation followed the main renal artery. A significant portion of the renal nerves (late arriving nerves) frequently reached the kidney (73% of the right kidney and 53% of the left kidney) bypassing the main renal artery. The ratio of the main renal artery length/aorta-renal hilar distance proved to be a useful variable to identify the presence/absence of these late arriving nerves (odds ratio, 0.001 (95% CI, 0.00002-0.0692; P: 0.001) with a cutoff of 0.75 (sensitivity: 0.68, specificity: 0.83, area under ROC curve at threshold: 0.76). When present, polar arteries were also highly associated with the presence of late arriving nerve. Finally, the perivascular space around the proximal main renal artery was frequently occupied by fused ganglia from the solar plexus (right kidney: 53%, left kidney: 83%) and/or by the lumbar sympathetic chain (right kidney: 63%, left kidney: 60%). Both carried innervation to the kidneys but importantly also to other abdominal and pelvic organs, which can be accidentally denervated if the proximal renal artery is targeted for ablation. These novel anatomic insights may help guide future procedural treatment recommendations to increase the likelihood of safely reaching and destroying targeted nerves during renal denervation procedures.


Asunto(s)
Desnervación/métodos , Hipertensión/cirugía , Riñón/inervación , Arteria Renal/anatomía & histología , Simpatectomía/métodos , Cadáver , Humanos , Riñón/anatomía & histología , Microdisección , Arteria Renal/cirugía
11.
Heart ; 2020 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-32843495

RESUMEN

OBJECTIVE: The aim of this work is to assess the relationship between significant paravalvular leak (SPL) after transcatheter aortic valve implantation (TAVI) on anaemia and their impact on prognosis. METHODS: Observational analytic study developed at two university hospitals, including all consecutive patients who underwent TAVI during a 10-year period (2009 to 2018). A logistic regression model was created to determine independent predictors of anaemia at 3 months. Time to event outcomes were analysed with Cox regression. Median follow-up was 21.3±21.9 months. RESULTS: 788 patients were included. 5.3% had SPL. SPL was an independent predictor of anaemia 3 months after TAVI (OR: 8.31, 95% CI: 2.06 to 33.50). SPL and anaemia at 3 months were independently associated with long-term mortality (HR: 1.82, 95% CI: 1.16 to 2.85; HR: 2.07, 95% CI: 1.39 to 3.08). CONCLUSION: SPL is an independent predictor of anaemia at 3 months after TAVI, a condition that doubles long-term mortality. Our findings could explain in part the worse prognosis of SPL after TAVI. Further pathophysiological studies are necessary to explain this association.

12.
J Am Coll Cardiol ; 76(20): 2321-2330, 2020 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-33183506

RESUMEN

BACKGROUND: The fear of contagion during the coronavirus disease-2019 (COVID-19) pandemic may have potentially refrained patients with ST-segment elevation myocardial infarction (STEMI) from accessing the emergency system, with subsequent impact on mortality. OBJECTIVES: The ISACS-STEMI COVID-19 registry aims to estimate the true impact of the COVID-19 pandemic on the treatment and outcome of patients with STEMI treated by primary percutaneous coronary intervention (PPCI), with identification of "at-risk" patient cohorts for failure to present or delays to treatment. METHODS: This retrospective registry was performed in European high-volume PPCI centers and assessed patients with STEMI treated with PPPCI in March/April 2019 and 2020. Main outcomes are the incidences of PPCI, delayed treatment, and in-hospital mortality. RESULTS: A total of 6,609 patients underwent PPCI in 77 centers, located in 18 countries. In 2020, during the pandemic, there was a significant reduction in PPCI as compared with 2019 (incidence rate ratio: 0.811; 95% confidence interval: 0.78 to 0.84; p < 0.0001). The heterogeneity among centers was not related to the incidence of death due to COVID-19. A significant interaction was observed for patients with arterial hypertension, who were less frequently admitted in 2020 than in 2019. Furthermore, the pandemic was associated with a significant increase in door-to-balloon and total ischemia times, which may have contributed to the higher mortality during the pandemic. CONCLUSIONS: The COVID-19 pandemic had significant impact on the treatment of patients with STEMI, with a 19% reduction in PPCI procedures, especially among patients suffering from hypertension, and a longer delay to treatment, which may have contributed to the increased mortality during the pandemic. (Primary Angioplasty for STEMI During COVID-19 Pandemic [ISACS-STEMI COVID-19] Registry; NCT04412655).


Asunto(s)
Infecciones por Coronavirus , Pandemias , Intervención Coronaria Percutánea/estadística & datos numéricos , Neumonía Viral , Sistema de Registros , Infarto del Miocardio con Elevación del ST/mortalidad , Anciano , COVID-19 , Europa (Continente)/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/terapia
13.
Chest ; 133(6): 1495-1504, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18574295

RESUMEN

Congestive heart failure (HF), an exceedingly common and costly disease, is frequently seen in association with central sleep apnea (CSA), which often manifests as a periodic breathing rhythm referred to as Cheyne-Stokes respiration. CSA has historically been considered to be a marker of heart disease, since improvement in cardiac status is often associated with the attenuation of CSA. However, this mirroring of HF and CSA may suggest bidirectional importance to their relationship. In fact, observational data suggest that CSA, associated with repetitive oxyhemoglobin desaturations and surges in sympathetic neural activity, may be of pathophysiologic significance in HF outcomes. In light of the disappointing results from the first large trial assessing therapy with continuous positive airway pressure in patients with CSA and HF, further large-scale interventional trials will be needed to assess the role, if any, of CSA treatment on the outcomes of patients with HF. This review will discuss epidemiologic, pathophysiologic, diagnostic, and therapeutic considerations of CSA in the setting of HF.


Asunto(s)
Dióxido de Carbono/farmacología , Presión de las Vías Aéreas Positiva Contínua , Insuficiencia Cardíaca , Apnea Central del Sueño , Dióxido de Carbono/uso terapéutico , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Oxígeno/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto , Respiración/efectos de los fármacos , Apnea Central del Sueño/complicaciones , Apnea Central del Sueño/diagnóstico , Apnea Central del Sueño/fisiopatología
14.
Chest ; 133(4): 927-33, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18263678

RESUMEN

BACKGROUND: Obstructive sleep apnea (OSA) is associated with coronary risk factors, but it is unknown if OSA is associated with development of coronary disease. We evaluated the association between OSA and the presence of subclinical coronary disease assessed by coronary artery calcification (CAC). METHODS: Consecutive patients with no history of coronary disease who underwent electron-beam CT within 3 years of polysomnography between March 1991 and December 2003 were included. OSA was defined by an apnea-hypopnea index (AHI) > or = 5 events per hour, and patients were grouped by quartiles of AHI severity. Logistic regression modeled the association between OSA severity and presence of CAC. RESULTS: There were 202 patients (70% male; median age, 50 years; mean body mass index, 32 kg/m(2); 8% diabetic; 9% current smokers; 60% hypercholesterolemic; and 47% hypertensive). OSA was present in 76%. CAC was present in 67% of OSA patients and 31% of non-OSA patients (p < 0.001). Median CAC scores (Agatston units) were 9 in OSA patients and 0 in non-OSA patients (p < 0.001). Median CAC score was higher as OSA severity increased (p for trend by AHI quartile < 0.001). With multivariate adjustment, the odds ratio for CAC increased with OSA severity. Using the first AHI quartile as reference, the adjusted odds ratios for the second, third, and fourth quartiles were 2.1 (p = 0.12), 2.4 (p = 0.06), and 3.3 (p = 0.03), respectively. CONCLUSIONS: In patients without clinical coronary disease, the presence and severity of OSA is independently associated with the presence and extent of CAC. OSA identifies patients at risk for coronary disease and may represent a highly prevalent modifiable risk factor.


Asunto(s)
Calcinosis/complicaciones , Enfermedad de la Arteria Coronaria/complicaciones , Apnea Obstructiva del Sueño/complicaciones , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Estudios Transversales , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Polisomnografía , Factores de Riesgo , Índice de Severidad de la Enfermedad , Apnea Obstructiva del Sueño/patología , Tomografía Computarizada por Rayos X
15.
JACC Cardiovasc Interv ; 11(10): 981-991, 2018 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-29798776

RESUMEN

OBJECTIVES: This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). BACKGROUND: Treatment of patients with DES-ISR remains a challenge. METHODS: The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. RESULTS: A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p < 0.01). Three-year clinical follow-up was obtained in all enrolled patients (100%). The combined clinical outcome measure of cardiac death, myocardial infarction and target lesion revascularization was significantly reduced in the EES arm (19 [12.3%] vs. 31 [20.1%]; p = 0.04; hazard ratio: 0.57 [95% confidence interval: 0.34 to 0.96]), driven by a lower need for target lesion revascularization (11 [7.1%] vs. 24 [15.6%]; p = 0.015; hazard ratio: 0.43 [95% confidence interval: 0.21 to 0.87]). The need for "late" (>1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. CONCLUSIONS: The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940).


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Retratamiento , Factores de Riesgo , España , Factores de Tiempo , Resultado del Tratamiento
16.
Sleep ; 30(3): 291-303, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17425225

RESUMEN

Sleep-disordered breathing, broadly characterized by obstructive sleep apnea (OSA) and central sleep apnea (CSA), is an increasingly recognized public health burden. OSA, consisting of apneas or hypopneas associated with respiratory efforts in the face of upper airway narrowing or collapse, is a common disorder that can be effectively treated with continuous positive airway pressure (CPAP). OSA not only results in daytime sleepiness and impaired executive function, but also has been implicated as a possible cause of systemic disease, particularly of the cardiovascular system. CSA, which may coexist with OSA, has gained attention because of the association of Cheyne-Stokes respiration with an ever-increasing prevalence of heart failure in an aging population. This article reviews some of the extensive literature on pathophysiologic mechanisms as they may relate to the development of cardiac and vascular disease and examine the evidence suggesting OSA as a specific cause of certain cardiovascular conditions. Available evidence regarding the implications of CSA in the context of heart failure is discussed.


Asunto(s)
Enfermedades Cardiovasculares/epidemiología , Apnea Central del Sueño/epidemiología , Apnea Obstructiva del Sueño/epidemiología , Sistema Nervioso Autónomo/fisiopatología , Enfermedades Cardiovasculares/fisiopatología , Respiración de Cheyne-Stokes/epidemiología , Respiración de Cheyne-Stokes/fisiopatología , Comorbilidad , Estudios Transversales , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Hipertensión/epidemiología , Hipertensión/fisiopatología , Factores de Riesgo , Apnea Central del Sueño/fisiopatología , Apnea Obstructiva del Sueño/fisiopatología
17.
Rev Esp Cardiol (Engl Ed) ; 70(3): 170-177, 2017 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-27745858

RESUMEN

INTRODUCTION AND OBJECTIVES: Thrombus aspiration allows analysis of intracoronary material in patients with ST-segment elevation myocardial infarction. Our objective was to characterize this material by immunohistology and to study its possible association with patient progress. METHODS: This study analyzed a prospective cohort of 142 patients undergoing primary angioplasty with positive coronary aspiration. Histological examination of aspirated samples included immunohistochemistry stains for the detection of plaque fragments. The statistical analysis comprised histological variables (thrombus age, degree of inflammation, presence of plaque), the patients' clinical and angiographic features, estimation of survival curves, and logistic regression analysis. RESULTS: Among the histological markers, only the presence of plaque (63% of samples) was associated with postinfarction clinical events. Factors associated with 5-year event-free survival were the presence of plaque in the aspirate (82.2% vs 66.0%; P = .033), smoking (82.5% smokers vs 66.7% nonsmokers; P = .036), culprit coronary artery (83.3% circumflex or right coronary artery vs 68.5% anterior descending artery; P = .042), final angiographic flow (80.8% II-III vs 30.0% 0-I; P < .001) and left ventricular ejection fraction ≥ 35% at discharge (83.7% vs 26.7%; P < .001). On multivariable Cox regression analysis with these variables, independent predictors of event-free survival were the presence of plaque (hazard ratio, 0.37; 95%CI, 0.18-0.77; P = .008), and left ventricular ejection fraction (hazard ratio, 0.92; 95%CI, 0.88-0.95; P < .001). CONCLUSIONS: The presence of plaque in the coronary aspirate of patients with ST elevation myocardial infarction may be an independent prognostic marker. CD68 immunohistochemical stain is a good method for plaque detection.


Asunto(s)
Trombosis Coronaria/patología , Placa Aterosclerótica/patología , Infarto del Miocardio con Elevación del ST/patología , Cuidados Posteriores , Angiografía Coronaria/mortalidad , Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/patología , Trombosis Coronaria/mortalidad , Supervivencia sin Enfermedad , Femenino , Humanos , Inmunohistoquímica , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/estadística & datos numéricos , Placa Aterosclerótica/mortalidad , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/mortalidad , Fumar/efectos adversos , Fumar/mortalidad , Manejo de Especímenes
18.
Rev Esp Cardiol (Engl Ed) ; 70(3): 178-185, 2017 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-27810235

RESUMEN

INTRODUCTION AND OBJECTIVES: The beneficial effect of coronary collateral circulation (CC) in patients with ST-segment elevation myocardial infarction is controversial. The aim of this study was to evaluate the impact of CC before reperfusion with primary angioplasty (PA) on the long-term prognosis of these patients. METHODS: Retrospective observational study of a cohort of 947 patients treated with PA and TIMI grade ≤ 1 flow in a single center from 2005 to 2013. Propensity score matching was used to create 2 groups of 175 patients each, matched by the degree of CC (Rentrop 0-1 vs Rentrop 2-3). In the matched cohort, we determined the impact of CC on total mortality, cardiovascular mortality, and a combined adverse cardiovascular event endpoint for a median follow-up of 864 (interquartile range, 396-1271) days. RESULTS: Of a total of 947 patients included, 735 (78%) had Rentrop 0 to 1 and 212 (22%) had Rentrop 2 to 3. During follow-up, 105 patients died, 71 from cardiovascular causes. In the matched cohort, the total mortality rate was similar between the 2 groups (Rentrop 0-1 [8.8%] vs Rentrop 2-3 [6.3%]; HR = 1.22; 95%CI, 0.50-2.94; P = .654). There were no differences in cardiovascular mortality (Rentrop 0-1 [4.6%] vs Rentrop 2-3 [2.3%]; sHR = 0.49; 95%CI, 0.14-1.62; P = .244) or the composite endpoint including cardiovascular death, reinfarction, target vessel revascularization, and coronary artery bypass surgery (Rentrop 0-1 [18.8%] vs Rentrop 2-3 [13.1%]; sHR = 0.68; 95%CI, 0.40-1.15; P = .157). CONCLUSIONS: In this contemporary series, the presence of good CC before PA was not associated with better long-term clinical outcomes.


Asunto(s)
Circulación Colateral/fisiología , Circulación Coronaria/fisiología , Infarto del Miocardio con Elevación del ST/cirugía , Cuidados Posteriores , Anticoagulantes/uso terapéutico , Angiografía Coronaria/mortalidad , Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Quimioterapia Combinada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reperfusión Miocárdica/mortalidad , Reperfusión Miocárdica/estadística & datos numéricos , Variaciones Dependientes del Observador , Inhibidores de Agregación Plaquetaria/uso terapéutico , Pronóstico , Puntaje de Propensión , Recurrencia , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/mortalidad , Infarto del Miocardio con Elevación del ST/fisiopatología , España/epidemiología
19.
Am J Cardiol ; 119(7): 983-990, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28139220

RESUMEN

Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is particularly challenging. We sought to compare results of drug-eluting balloons in patients with DES-ISR with those in patients with bare-metal stent (BMS) ISR. A pooled analysis of the Restenosis Intra-Stent: Drug-Eluting Balloon versus Everolimus-Eluting Stent IV and V randomized trials was performed. Both trials had identical inclusion and exclusion criteria. Results of drug-eluting balloons in 95 patients with BMS-ISR and 154 patients with DES-ISR were compared. Patients with DES-ISR were more frequently diabetics, presented more often as an acute coronary syndrome and had more severe lesions and more frequently a focal pattern, including edge-ISR. Late angiographic findings (92% of eligible patients), including minimal lumen diameter (1.80 ± 0.6 vs 2.01 ± 0.6 mm, p = 0.001; absolute mean difference 0.21 mm; 95% confidence interval 0.04 to 0.38; p = 0.014) and restenosis rate (19% vs 9.5%, p <0.05) were poorer in DES-ISR. Results were consistent across 10 prespecified subgroups. Moreover, on multiple linear regression analysis, minimal lumen diameter at follow-up remained significantly smaller in patients with DES-ISR after adjusting for potential confounders (adjusted absolute mean difference 0.17 mm; 95% confidence interval 0.04 to 0.41; p = 0.019). Finally, at 1-year clinical follow-up (100% of patients), rates of target vessel revascularization (16% vs 6%, p = 0.02) and of the main combined clinical end point (18% vs 8%, p = 0.03) were significantly higher in patients treated for DES-ISR. In conclusion, this study confirms the efficacy of DEB for patients with ISR. However, the long-term clinical and angiographic results of DEB are poorer in patients with DES-ISR than in those with BMS-ISR. (ClinicalTrials.govIdentifier:NCT01239953&NCT01239940).


Asunto(s)
Reestenosis Coronaria/terapia , Stents , Anciano , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos , Everolimus/uso terapéutico , Femenino , Humanos , Masculino , Paclitaxel/uso terapéutico , Resultado del Tratamiento
20.
EuroIntervention ; 12(13): 1587-1594, 2017 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-27821374

RESUMEN

AIMS: Our aim was to assess the safety and efficacy of paclitaxel-eluting balloon (PTX-B) treatment after bare metal stent (BMS) implantation in patients undergoing primary angioplasty. METHODS AND RESULTS: After BMS implantation, patients were randomised (1:1) to treatment with a PTX-B or no PTX-B treatment (BMS group). The primary endpoint was in-stent late luminal loss (LLL) at nine-month follow-up. OCT was carried out on the first 20% of consecutive patients included in the study. Two hundred and twenty-three patients were randomised (BMS: 112, PTX-B: 111). At nine months, median LLL was 0.80 mm (interquartile range [IQR] 0.36-1.26) in the BMS group vs. 0.31 mm (IQR 0.00-0.58) in the PTX-B group, p<0.0001. Binary restenosis was significantly lower in the PTX-B group: 29.8% vs. 2.2%, p<0.0001, 95% confidence interval (CI): 3.2-54.2. Nine-month OCT showed good strut coverage in both groups but greater in the BMS group (100±0.0% vs. 99.52±1.11%, p=0.03) with very low rates of malapposed struts per lesion. One-year MACE was significantly lower in the PTX-B group (12.5% vs. 3.6%, p=0.016). CONCLUSIONS: PTX-B after successful BMS implantation resulted in less LLL and better clinical outcomes as compared with a BMS-only strategy. This was associated with good stent strut coverage and very low rates of malapposed struts.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio/terapia , Paclitaxel/uso terapéutico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/métodos , Angiografía Coronaria/métodos , Reestenosis Coronaria/prevención & control , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Sirolimus/uso terapéutico , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA