Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Clin Chem ; 70(3): 528-537, 2024 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-38431279

RESUMEN

BACKGROUND: Lipid profiling is central for coronary artery disease (CAD) risk assessment. Nonadherence or unreported use of lipid-lowering drugs, particularly statins, can significantly complicate the association between lipid profile measures and CAD clinical outcomes. By combining medication history evaluation with statin analysis in plasma, we determined the effects of inaccurately reported statin use on lipid profile measures and their association with CAD risk. METHODS: We compared medication history of statin use with statin concentration measurements, by liquid chromatography-tandem mass spectrometry, in 690 participants undergoing coronary angiography (63 ± 11 years of age). Nominal logistic regression was employed to model CAD diagnosis with statin measurements, phenotypic, and lipid profile characteristics. RESULTS: Medication history of statin use was confirmed by statin assay for 81% of the patients. Surprisingly, statins were detected in 46% of patients without statin use records. Nonreported statin use was disproportionately higher among older participants. Stratifying samples by statin history resulted in underestimated LDL-lipid measures. Apolipoprotein B concentrations had a significant inverse CAD association, which became nonsignificant upon re-stratification using the statin assay data. CONCLUSIONS: Our study uncovered prominent discrepancies between medication records and actual statin use measured by mass spectrometry. We showed that inaccurate statin use assessments may lead to overestimation and underestimation of LDL levels in statin user and nonuser categories, exaggerating the reverse epidemiology association between LDL levels and CAD diagnosis. Combining medication history and quantitative statin assay data can significantly improve the design, analysis, and interpretation of clinical and epidemiological studies.


Asunto(s)
Enfermedad de la Arteria Coronaria , Inhibidores de Hidroximetilglutaril-CoA Reductasas , Humanos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Lípidos , Medición de Riesgo , Factores de Riesgo , Persona de Mediana Edad , Anciano
2.
Alzheimers Dement ; 19(2): 391-404, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35416404

RESUMEN

We propose the hypothesis that small high-density lipoprotein (HDL) particles reduce the risk of Alzheimer's disease (AD) by virtue of their capacity to exchange lipids, affecting neuronal membrane composition and vascular and synaptic functions. Concentrations of small HDLs in cerebrospinal fluid (CSF) and plasma were measured in 180 individuals ≥60 years of age using ion mobility methodology. Small HDL concentrations in CSF were positively associated with performance in three domains of cognitive function independent of apolipoprotein E (APOE) ε4 status, age, sex, and years of education. Moreover, there was a significant correlation between levels of small HDLs in CSF and plasma. Further studies will be aimed at determining whether specific components of small HDL exchange across the blood, brain, and CSF barriers, and developing approaches to exploit small HDLs for therapeutic purposes.


Asunto(s)
Enfermedad de Alzheimer , Humanos , Enfermedad de Alzheimer/líquido cefalorraquídeo , Apolipoproteínas E , Apolipoproteína E4 , Encéfalo , Cognición , Péptidos beta-Amiloides/líquido cefalorraquídeo
3.
Int J Mol Sci ; 24(9)2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37175638

RESUMEN

Designing studies for lipid-metabolism-related biomarker discovery is challenging because of the high prevalence of various statin and fibrate usage for lipid-lowering therapies. When the statin and fibrate use is determined based on self-reports, patient adherence to the prescribed statin dose regimen remains unknown. A potentially more accurate way to verify a patient's medication adherence is by direct analytical measurements. Current analytical methods are prohibitive because of the limited panel of drugs per test and large sample volume requirement that is not available from archived samples. A 4-min-long method was developed for the detection of seven statins and three fibrates using 10 µL of plasma analyzed via reverse-phase liquid chromatography and tandem mass spectrometry. The method was applied to the analysis of 941 archived plasma samples collected from patients before cardiac catheterization. When statin use was self-reported, statins were detected in 78.6% of the samples. In the case of self-reported atorvastatin use, the agreement with detection was 90.2%. However, when no statin use was reported, 42.4% of the samples had detectable levels of statins, with a similar range of concentrations as the samples from the self-reported statin users. The method is highly applicable in population studies designed for biomarker discovery or diet and lifestyle intervention studies, where the accuracy of statin or fibrate use may strongly affect the statistical evaluation of the biomarker data.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Ácidos Fíbricos/uso terapéutico , Cromatografía Liquida , Espectrometría de Masas en Tándem , Atorvastatina/uso terapéutico , Biomarcadores
4.
J Lipid Res ; 61(3): 306-315, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31953305

RESUMEN

The composition-function relationship of HDL particles and its effects on the mechanisms driving coronary heart disease (CHD) is poorly understood. We tested the hypothesis that the functionality of HDL particles is significantly influenced by their lipid composition. Using a novel 3D-separation method, we isolated five different-sized HDL subpopulations from CHD patients who had low preß-1 functionality (low-F) (ABCA1-dependent cholesterol-efflux normalized for preß-1 concentration) and controls who had either low-F or high preß-1 functionality (high-F). Molecular numbers of apoA-I, apoA-II, and eight major lipid classes were determined in each subpopulation by LC-MS. The average number of lipid molecules decreased from 422 in the large spherical α-1 particles to 57 in the small discoid preß-1 particles. With decreasing particle size, the relative concentration of free cholesterol (FC) decreased in α-mobility but not in preß-1 particles. Preß-1 particles contained more lipids than predicted; 30% of which were neutral lipids (cholesteryl ester and triglyceride), indicating that these particles were mainly remodeled from larger particles not newly synthesized. There were significant correlations between HDL-particle functionality and the concentrations of several lipids. Unexpectedly, the phospholipid:FC ratio was significantly correlated with large-HDL-particle functionality but not with preß-1 functionality. There was significant positive correlation between particle functionality and total lipids in high-F controls, indicating that the lipid-binding capacity of apoA-I plays a major role in the cholesterol efflux capacity of HDL particles. Functionality and lipid composition of HDL particles are significantly correlated and probably both are influenced by the lipid-binding capacity of apoA-I.


Asunto(s)
Enfermedad Coronaria/sangre , Gotas Lipídicas/química , Lipoproteínas HDL/sangre , Adulto , Anciano , Enfermedad Coronaria/metabolismo , Femenino , Humanos , Gotas Lipídicas/metabolismo , Lipoproteínas HDL/metabolismo , Masculino , Persona de Mediana Edad , Tamaño de la Partícula , Adulto Joven
5.
J Lipid Res ; 58(12): 2275-2288, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28986437

RESUMEN

As the lipidomics field continues to advance, self-evaluation within the community is critical. Here, we performed an interlaboratory comparison exercise for lipidomics using Standard Reference Material (SRM) 1950-Metabolites in Frozen Human Plasma, a commercially available reference material. The interlaboratory study comprised 31 diverse laboratories, with each laboratory using a different lipidomics workflow. A total of 1,527 unique lipids were measured across all laboratories and consensus location estimates and associated uncertainties were determined for 339 of these lipids measured at the sum composition level by five or more participating laboratories. These evaluated lipids detected in SRM 1950 serve as community-wide benchmarks for intra- and interlaboratory quality control and method validation. These analyses were performed using nonstandardized laboratory-independent workflows. The consensus locations were also compared with a previous examination of SRM 1950 by the LIPID MAPS consortium. While the central theme of the interlaboratory study was to provide values to help harmonize lipids, lipid mediators, and precursor measurements across the community, it was also initiated to stimulate a discussion regarding areas in need of improvement.


Asunto(s)
Benchmarking , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Lípidos/sangre , Humanos , Cooperación Internacional , Metabolismo de los Lípidos/fisiología , Lípidos/normas , Variaciones Dependientes del Observador , Estándares de Referencia , Reproducibilidad de los Resultados
6.
Instrum Sci Technol ; 46(1): 102-114, 2017 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37180980

RESUMEN

Tandem mass spectrometry (MS/MS)-based proteomic workflows with a bottom-up approach require enzymatic digestion of proteins to peptide analytes, usually by trypsin. Online coupling of trypsin digestion of proteins, using an immobilized enzyme reactor (IMER), with liquid chromatography (LC) and MS/MS is becoming a frequently used approach. However, finding IMER digestion conditions that allow quantitative analysis of multiple proteins with wide range of endogenous concentration requires optimization of multiple interactive parameters: digestion buffer flow rate, injection volume, sample dilution, and surfactant type/ concentration. In this report, we present a design of experiment approach for the optimization of an integrated IMER-LC-MS/MS platform. With bovine serum albumin as a model protein, the digestion efficacy and digestion rate were monitored based on LC-MS/MS peak area count versus protein concentration regression. The optimal parameters were determined through multivariate surface response modeling and consideration of diffusion controlled immobilized enzyme kinetics. The results may provide guidance to other users for the development of quantitative IMER-LC-MS/MS methods for other proteins.

7.
Anal Chem ; 81(2): 557-66, 2009 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-19072583

RESUMEN

Defensins are highly basic cationic peptides that are important components of the innate and adaptive immune response pathways. In addition, these peptides are involved in CD8+ T cell response to HIV-1, increased pulmonary infection risk among cystic fibrosis patients, upregulated levels of HNP-5 for patients with ulcerative colitis and Crohn's disease, and monitoring HNP-3 levels as a tumor classification scheme for cutaneous T cell lymphomas, and have promise in the pharmaceutical field as a new class of antibiotics. Here we present a parallel assay for the alpha (HNP1-3) and beta (HBD1-2) classes of defensins in saliva that are naturally observed in the concentration range of 1 ng/mL to 10 microg/mL. The method utilizes solid phase extraction of saliva samples combined with liquid chromatography-tandem mass spectrometry to identify and quantitate defensin targets. The approach involves limited sample manipulation and is easily amenable to automation. The saliva samples analyzed are derived from a large cohort study focused on examining the role of polymorphisms in genes of innate and adaptive immunity in modulating the response to vaccination for two gastrointestinal tract infections: typhoid and cholera. The alpha-defensin levels observed range from 1 to 10 microg/mL and correlate well with known active concentrations against a wide variety of pathogens. The observed concentration range for beta-defensins was between the detection limit and 33 ng/mL and had a sensitivity level that was comparable to immunoassay-based detection. This method is easily adapted for use in a clinical immunology setting and can be modified for other biological matrixes. This assay will facilitate examination of the production, secretion, and regulation of defensin peptides in a direct fashion to coordinate levels of these compounds with gender, age, response to vaccination, gene copy number, and oral health.


Asunto(s)
Defensinas/análisis , Saliva/química , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Cromatografía Liquida , Estudios de Cohortes , Defensinas/aislamiento & purificación , Humanos , Inmunidad Celular , Datos de Secuencia Molecular , Extracción en Fase Sólida , alfa-Defensinas/análisis , beta-Defensinas/análisis
8.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1118-1119: 137-147, 2019 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-31035135

RESUMEN

Progress toward better diagnosis and treatment of lipid metabolism-related diseases requires high throughput approaches for multiplexed quantitative analysis of structurally diverse lipids, including phospholipids (PLs). This work demonstrates a simplified "one-pot" phospholipid extraction protocol, as an alternative to conventional liquid-liquid extraction. Performed in a 96-well format, the extraction was coupled with high throughput UPLC and multiplexed tandem mass spectrometry (MS/MS) detection, allowing non-targeted quantification of phosphatidylcholines (PC), sphingomyelins (SM), lysophosphatidylcholines (LPC), phosphatidylethanolamines (PE), and phosphatidylinositols (PI). Using 50 µL aliquots of serum samples from 110 individuals, lipoproteins were fractionated by size, and analyzed for phospholipids and non-polar lipids including free cholesterol (FC), cholesteryl esters (CEs) and triglycerides (TGs). Analysis of serum samples with wide range of Total-TG levels showed significant differences in PL composition. The correlations of molar ratios in lipoprotein size fractions, SM/PL with FC/PL, PE/PL with TG/CE, and PE/PL with PI/PL, demonstrate the applicability of the method for quantitative composition analysis of high, low and very-low density lipoproteins (HDL, LDL and VLDL), and characterization of lipid metabolism related disease states.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Dislipidemias/sangre , Dislipidemias/diagnóstico , Fosfolípidos/sangre , Espectrometría de Masas en Tándem/métodos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Fosfolípidos/aislamiento & purificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Environ Res ; 107(2): 152-9, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18295197

RESUMEN

We conducted an interlaboratory study which differed from the typical study of this type because of its emphasis on comparing intralaboratory variability in results. We sent specimens to six laboratories experienced in the analysis of perfluorinated alkyl compounds in blood matrices and that use stringent procedures to control and assure accuracy and precision. Each received an identical set of 60 plasma specimens that were analyzed in six completely independent batches. Split specimens were included so that within- and between-batch coefficients of variation could be calculated. All laboratories used liquid chromatography-tandem mass spectrometry (LC-MS/MS). The concentrations of perfluorooctanesulfonate (PFOS), perfluorooctanoate (PFOA), and perfluorohexanesulfonate (PFHxS) measured in the specimens in general showed a high level of agreement, although in some cases the agreement was only moderate. The average within- and between-batch coefficient of variation for PFOS was 9.1% and 9.3%; for PFOA was 14.5% and 14.5%; and for PFHxS was 14.5% and 17.0%. The recent availability of labeled internal standards, among other advances, has facilitated improvement in the accuracy and precision of the assays. Considering the degree of between-subject variation in levels among people in background-exposed populations, the results indicate that biomarker-based epidemiologic studies of associations with health could have reasonable precision.


Asunto(s)
Monitoreo del Ambiente/normas , Contaminantes Ambientales/análisis , Fluorocarburos/sangre , Adulto , Biomarcadores/sangre , Femenino , Humanos , Masculino , Embarazo
10.
PLoS One ; 13(4): e0194797, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29634782

RESUMEN

Lipoproteins are complex molecular assemblies that are key participants in the intricate cascade of extracellular lipid metabolism with important consequences in the formation of atherosclerotic lesions and the development of cardiovascular disease. Multiplexed mass spectrometry (MS) techniques have substantially improved the ability to characterize the composition of lipoproteins. However, these advanced MS techniques are limited by traditional pre-analytical fractionation techniques that compromise the structural integrity of lipoprotein particles during separation from serum or plasma. In this work, we applied a highly effective and gentle hydrodynamic size based fractionation technique, asymmetric flow field-flow fractionation (AF4), and integrated it into a comprehensive tandem mass spectrometry based workflow that was used for the measurement of apolipoproteins (apos A-I, A-II, A-IV, B, C-I, C-II, C-III and E), free cholesterol (FC), cholesterol esters (CE), triglycerides (TG), and phospholipids (PL) (phosphatidylcholine (PC), sphingomyelin (SM), phosphatidylethanolamine (PE), phosphatidylinositol (PI) and lysophosphatidylcholine (LPC)). Hydrodynamic size in each of 40 size fractions separated by AF4 was measured by dynamic light scattering. Measuring all major lipids and apolipoproteins in each size fraction and in the whole serum, using total of 0.1 ml, allowed the volumetric calculation of lipoprotein particle numbers and expression of composition in molar analyte per particle number ratios. Measurements in 110 serum samples showed substantive differences between size fractions of HDL and LDL. Lipoprotein composition within size fractions was expressed in molar ratios of analytes (A-I/A-II, C-II/C-I, C-II/C-III. E/C-III, FC/PL, SM/PL, PE/PL, and PI/PL), showing differences in sample categories with combinations of normal and high levels of Total-C and/or Total-TG. The agreement with previous studies indirectly validates the AF4-LC-MS/MS approach and demonstrates the potential of this workflow for characterization of lipoprotein composition in clinical studies using small volumes of archived frozen samples.


Asunto(s)
Apolipoproteínas/sangre , Cromatografía Liquida/métodos , Fraccionamiento de Campo-Flujo/métodos , Lípidos/sangre , Lipoproteínas/sangre , Espectrometría de Masas en Tándem/métodos , Apolipoproteína A-I/metabolismo , Apolipoproteína B-100/metabolismo , Análisis Químico de la Sangre/métodos , Calibración , Colesterol/química , Humanos , Luz , Modelos Estadísticos , Tamaño de la Partícula , Control de Calidad , Dispersión de Radiación , Flujo de Trabajo
11.
J Am Soc Mass Spectrom ; 28(11): 2319-2329, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28801822

RESUMEN

We demonstrate the application of in-source nitrogen collision-induced dissociation (CID) that eliminates the need for ester hydrolysis before simultaneous analysis of esterified cholesterol (EC) and triglycerides (TG) along with free cholesterol (FC) from human serum, using normal phase liquid chromatography (LC) coupled to atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS/MS). The analysis requires only 50 µL of 1:100 dilute serum with a high-throughput, precipitation/evaporation/extraction protocol in one pot. Known representative mixtures of EC and TG species were used as calibrators with stable isotope labeled analogs as internal standards. The APCI MS source was operated with nitrogen source gas. Reproducible in-source CID was achieved with the use of optimal cone voltage (declustering potential), generating FC, EC, and TG lipid class-specific precursor fragment ions for multiple reaction monitoring (MRM). Using a representative mixture of purified FC, CE, and TG species as calibrators, the method accuracy was assessed with analysis of five inter-laboratory standardization materials, showing -10% bias for Total-C and -3% for Total-TG. Repeated duplicate analysis of a quality control pool showed intra-day and inter-day variation of 5% and 5.8% for FC, 5.2% and 8.5% for Total-C, and 4.1% and 7.7% for Total-TG. The applicability of the method was demonstrated on 32 serum samples and corresponding lipoprotein sub-fractions collected from normolipidemic, hypercholesterolemic, hypertriglyceridemic, and hyperlipidemic donors. The results show that in-source CID coupled with isotope dilution UHPLC-MS/MS is a viable high precision approach for translational research studies where samples are substantially diluted or the amounts of archived samples are limited. Graphical Abstract ᅟ.


Asunto(s)
Colesterol/sangre , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Triglicéridos/sangre , Ésteres del Colesterol/sangre , Humanos , Hidrólisis , Reproducibilidad de los Resultados
12.
J Proteomics ; 150: 258-267, 2017 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-27667389

RESUMEN

Apolipoproteins measured in plasma or serum are potential biomarkers for assessing metabolic irregularities that are associated with the development of cardiovascular disease (CVD). LC-MS/MS allows quantitative measurement of multiple apolipoproteins in the same sample run. However, the accuracy and precision of the LC-MS/MS measurement depends on the reproducibility of the enzymatic protein digestion step. With the application of an immobilized enzyme reactor (IMER), the reproducibility of the trypsin digestion can be controlled with high precision via flow rate, column volume and temperature. In this report, we demonstrate the application of an integrated IMER-LC-MS/MS platform for the simultaneous quantitative analysis of eight apolipoproteins. Using a dilution series of a characterized serum pool as calibrator, the method was validated by repeated analysis of pooled sera and individual serum samples with a wide range of lipid profiles, all showing intra-assay CV<4.4% and inter-assay CV<8%. In addition, the method was compared with traditional homogeneous digestion coupled LC-MS/MS for the quantification of apoA-I and apoB-100. Applied in large scale human population studies, this method can serve the translation of a wider panel of apolipoprotein biomarkers from research to clinical application. SIGNIFICANCE: Currently, the translation of apolipoprotein biomarkers to clinical application is impaired because of the high cost of large cohort studies using traditional single-analyte immunoassays. The application of on-line tryptic digestion coupled with LC-MS/MS analysis is an effective way to address this problem. In this work we demonstrate a high throughput, multiplexed, automated proteomics workflow for the simultaneous analysis of multiple proteins.


Asunto(s)
Apolipoproteínas/análisis , Proteolisis , Proteómica/métodos , Espectrometría de Masas en Tándem/métodos , Tripsina/metabolismo , Apolipoproteínas/metabolismo , Biomarcadores/sangre , Análisis Químico de la Sangre/métodos , Proteínas Sanguíneas/análisis , Proteínas Sanguíneas/metabolismo , Cromatografía Liquida , Estudios de Factibilidad , Humanos , Reproducibilidad de los Resultados
13.
Proteomics Clin Appl ; 11(7-8)2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28296203

RESUMEN

PURPOSE: Apolipoprotein A-I (ApoA-I) and apolipoprotein B-100 (ApoB-100) are amphipathic proteins that are strong predictors of cardiovascular disease risk. The traceable calibration of apolipoprotein assays is a persistent challenge, especially for ApoB-100, which cannot be solubilized in purified form. EXPERIMENTAL DESIGN: A simultaneous quantitation method for ApoA-I and ApoB-100 was developed using tryptic digestion without predigestion reduction and alkylation, followed by LC separation coupled with isotope dilution MS analysis. The accuracy of the method was assured by selecting structurally exposed signature peptides, optimal choice of detergent, protein:enzyme ratio, and incubation time. Peptide calibrators were value assigned by isobaric tagging isotope dilution MS amino acid analysis. RESULTS: The method reproducibility was validated in technical repeats of three serum samples, giving 2-3% intraday CVs (N = 5) and <7% interday CVs (N = 21). The repeated analysis of interlaboratory harmonization standards showed -1% difference for ApoA-I and -12% for ApoB-100 relative to the assigned value. The applicability of the method was demonstrated by repeated analysis of 24 patient samples with a wide range of total cholesterol and triglyceride levels. CONCLUSIONS AND CLINICAL RELEVANCE: The method is applicable for simultaneous analysis of ApoA-I and ApoB-100 in patient samples, and for characterization of serum pool calibrators for other analytical platforms.


Asunto(s)
Apolipoproteína A-I/química , Apolipoproteína B-100/química , Análisis Químico de la Sangre/métodos , Espectrometría de Masas , Fragmentos de Péptidos/sangre , Proteolisis , Tripsina/metabolismo , Secuencia de Aminoácidos , Apolipoproteína A-I/metabolismo , Apolipoproteína B-100/metabolismo , Calibración , Cromatografía Liquida , Humanos , Isótopos/química , Modelos Lineales , Fragmentos de Péptidos/química , Fragmentos de Péptidos/metabolismo , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA