Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Radiology ; 306(3): e212922, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36318032

RESUMEN

Background Deep learning (DL)-based MRI reconstructions can reduce examination times for turbo spin-echo (TSE) acquisitions. Studies that prospectively employ DL-based reconstructions of rapidly acquired, undersampled spine MRI are needed. Purpose To investigate the diagnostic interchangeability of an unrolled DL-reconstructed TSE (hereafter, TSEDL) T1- and T2-weighted acquisition method with standard TSE and to test their impact on acquisition time, image quality, and diagnostic confidence. Materials and Methods This prospective single-center study included participants with various spinal abnormalities who gave written consent from November 2020 to July 2021. Each participant underwent two MRI examinations: standard fully sampled T1- and T2-weighted TSE acquisitions (reference standard) and prospectively undersampled TSEDL acquisitions with threefold and fourfold acceleration. Image evaluation was performed by five readers. Interchangeability analysis and an image quality-based analysis were used to compare the TSE and TSEDL images. Acquisition time and diagnostic confidence were also compared. Interchangeability was tested using the individual equivalence index regarding various degenerative and nondegenerative entities, which were analyzed on each vertebra and defined as discordant clinical judgments of less than 5%. Interreader and intrareader agreement and concordance (κ and Kendall τ and W statistics) were computed and Wilcoxon and McNemar tests were used. Results Overall, 50 participants were evaluated (mean age, 46 years ± 18 [SD]; 26 men). The TSEDL method enabled up to a 70% reduction in total acquisition time (100 seconds for TSEDL vs 328 seconds for TSE, P < .001). All individual equivalence indexes were less than 4%. TSEDL acquisition was rated as having superior image noise by all readers (P < .001). No evidence of a difference was found between standard TSE and TSEDL regarding frequency of major findings, overall image quality, or diagnostic confidence. Conclusion The deep learning (DL)-reconstructed turbo spin-echo (TSE) method was found to be interchangeable with standard TSE for detecting various abnormalities of the spine at MRI. DL-reconstructed TSE acquisition provided excellent image quality, with a 70% reduction in examination time. German Clinical Trials Register no. DRKS00023278 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Hallinan in this issue.


Asunto(s)
Aprendizaje Profundo , Masculino , Humanos , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Columna Vertebral/diagnóstico por imagen , Estudios Prospectivos , Tiempo
2.
Eur Radiol ; 33(4): 2945-2953, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36474057

RESUMEN

OBJECTIVE: To evaluate the impact of the digital mammography imaging system on overall background enhancement on recombined contrast-enhanced spectral mammography (CESM) images, the overall background enhancement of two different mammography systems was compared. METHODS: In a retrospective single-center study, CESM images of n = 129 female patients who underwent CESM between 2016 and 2019 were analyzed independently by two radiologists. Two mammography machines of different manufacturers were compared qualitatively using a Likert-scale from 1 (minimal) to 4 (marked overall background enhancement) and quantitatively by placing a region of interest and measuring the intensity enhancement. Lesion conspicuity was analyzed using a Likert-scale from 1 (lesion not reliably distinguishable) to 5 (excellent lesion conspicuity). A multivariate regression was performed to test for potential biases on the quantitative results. RESULTS: Significant differences in qualitative background enhancement measurements between machines A and B were observed for both readers (p = 0.003 and p < 0.001). The quantitative evaluation showed significant differences in background enhancement with an average difference of 75.69 (99%-CI [74.37, 77.02]; p < 0.001). Lesion conspicuity was better for machine A for the first and second reader respectively (p = 0.009 and p < 0.001). The factor machine was the only influencing factor (p < 0.001). The factors contrast agent, breast density, age, and menstrual cycle could be excluded as potential biases. CONCLUSION: Mammography machines seem to significantly influence overall background enhancement qualitatively and quantitatively; thus, an impact on diagnostic accuracy appears possible. KEY POINTS: • Overall background enhancement on CESM differs between different vendors qualitatively and quantitatively. • Our retrospective single-center study showed consistent results of the qualitative and quantitative data analysis of overall background enhancement. • Lesion conspicuity is higher in cases of lower background enhancement on CESM.


Asunto(s)
Neoplasias de la Mama , Mamografía , Humanos , Femenino , Estudios Retrospectivos , Mamografía/métodos , Medios de Contraste/farmacología , Densidad de la Mama , Proyectos de Investigación , Neoplasias de la Mama/diagnóstico por imagen , Sensibilidad y Especificidad
3.
Pediatr Radiol ; 53(3): 438-449, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36399161

RESUMEN

BACKGROUND: Cross-sectional imaging-based morphological characteristics of pediatric rhabdomyosarcoma have failed to predict outcomes. OBJECTIVE: To evaluate the feasibility and possible value of generating tumor sub-volumes using voxel-wise analysis of metabolic and functional data from positron emission tomography/magnetic resonance imaging (PET/MR) or PET/computed tomography (CT) and MRI in rhabdomyosarcoma. MATERIALS AND METHODS: Thirty-four examinations in 17 patients who received PET/MRI or PET/CT plus MRI were analyzed. The volume of interest included total tumor volume before and after therapy. Apparent diffusion coefficients (ADC) and standard uptake values (SUV) were determined voxel-wise. Voxels were assigned to three different groups based on ADC and SUV: "viable tumor tissue," "intermediate tissue" or "possible necrosis." In a second approach, data were grouped into three clusters using the Gaussian mixture model. The ratio of these clusters to total tumor volume and changes due to chemotherapy were correlated with clinical and histopathological data. RESULTS: After chemotherapy, the proportion of voxels in the different groups changed significantly. A significant reduction of the proportion of voxels assigned to cluster 1 was found, from a mean of 36.4% to 2.5% (P < 0.001). There was a significant increase in the proportion of voxels in cluster 3 following chemotherapy from 24.8% to 81.6% (P = 0.02). The proportion of voxels in cluster 2 differed depending on the presence or absence of tumor recurrence, falling from 48% to 10% post-chemotherapy in the group with no tumor recurrence (P < 0.05) and from 29% to 23% (P > 0.05) in the group with tumor recurrence. CONCLUSION: Voxel-wise evaluation of multimodal data in rhabdomyosarcoma is feasible. Our initial results suggest that the different distribution of sub-volumes before and after therapy may have prognostic significance.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Rabdomiosarcoma , Niño , Humanos , Fluorodesoxiglucosa F18 , Carga Tumoral , Recurrencia Local de Neoplasia , Tomografía de Emisión de Positrones/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Radiofármacos
4.
Radiol Med ; 128(2): 184-190, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36609662

RESUMEN

OBJECTIVES: A deep learning-based super-resolution for postcontrast volume-interpolated breath-hold examination (VIBE) of the chest was investigated in this study. Aim was to improve image quality, noise, artifacts and diagnostic confidence without change of acquisition parameters. MATERIALS AND METHODS: Fifty patients who received VIBE postcontrast imaging of the chest at 1.5 T were included in this retrospective study. After acquisition of the standard VIBE (VIBES), a novel deep learning-based algorithm and a denoising algorithm were applied, resulting in enhanced images (VIBEDL). Two radiologists qualitatively evaluated both datasets independently, rating sharpness of soft tissue, vessels, bronchial structures, lymph nodes, artifacts, cardiac motion artifacts, noise levels and overall diagnostic confidence, using a Likert scale ranging from 1 to 4. In the presence of lung lesions, the largest lesion was rated regarding sharpness and diagnostic confidence using the same Likert scale as mentioned above. Additionally, the largest diameter of the lesion was measured. RESULTS: The sharpness of soft tissue, vessels, bronchial structures and lymph nodes as well as the diagnostic confidence, the extent of artifacts, the extent of cardiac motion artifacts and noise levels were rated superior in VIBEDL (all P < 0.001). There was no significant difference in the diameter or the localization of the largest lung lesion in VIBEDL compared to VIBES. Lesion sharpness as well as detectability was rated significantly better by both readers with VIBEDL (both P < 0.001). CONCLUSION: The application of a novel deep learning-based super-resolution approach in T1-weighted VIBE postcontrast imaging resulted in an improvement in image quality, noise levels and diagnostic confidence as well as in a shortened acquisition time.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Medios de Contraste , Estudios Retrospectivos , Imagenología Tridimensional/métodos , Aumento de la Imagen/métodos , Artefactos
5.
Eur Radiol ; 32(9): 6215-6229, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35389046

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the image quality and diagnostic performance of a deep-learning (DL)-accelerated two-dimensional (2D) turbo spin echo (TSE) MRI of the knee at 1.5 and 3 T in clinical routine in comparison to standard MRI. MATERIAL AND METHODS: Sixty participants, who underwent knee MRI at 1.5 and 3 T between October/2020 and March/2021 with a protocol using standard 2D-TSE (TSES) and DL-accelerated 2D-TSE sequences (TSEDL), were enrolled in this prospective institutional review board-approved study. Three radiologists assessed the sequences regarding structural abnormalities and evaluated the images concerning overall image quality, artifacts, noise, sharpness, subjective signal-to-noise ratio, and diagnostic confidence using a Likert scale (1-5, 5 = best). RESULTS: Overall image quality for TSEDL was rated to be excellent (median 5, IQR 4-5), significantly higher compared to TSES (median 5, IQR 4 - 5, p < 0.05), showing significantly lower extents of noise and improved sharpness (p < 0.001). Inter- and intra-reader agreement was almost perfect (κ = 0.92-1.00) for the detection of internal derangement and substantial to almost perfect (κ = 0.58-0.98) for the assessment of cartilage defects. No difference was found concerning the detection of bone marrow edema and fractures. The diagnostic confidence of TSEDL was rated to be comparable to that of TSES (median 5, IQR 5-5, p > 0.05). Time of acquisition could be reduced to 6:11 min using TSEDL compared to 11:56 min for a protocol using TSES. CONCLUSION: TSEDL of the knee is clinically feasible, showing excellent image quality and equivalent diagnostic performance compared to TSES, reducing the acquisition time about 50%. KEY POINTS: • Deep-learning reconstructed TSE imaging is able to almost halve the acquisition time of a three-plane knee MRI with proton density and T1-weighted images, from 11:56 min to 6:11 min at 3 T. • Deep-learning reconstructed TSE imaging of the knee provided significant improvement of noise levels (p < 0.001), providing higher image quality (p < 0.05) compared to conventional TSE imaging. • Deep-learning reconstructed TSE imaging of the knee had similar diagnostic performance for internal derangement of the knee compared to standard TSE.


Asunto(s)
Aprendizaje Profundo , Imagenología Tridimensional , Artefactos , Estudios de Factibilidad , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos
6.
Eur Radiol ; 31(12): 8975-8982, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34041572

RESUMEN

OBJECTIVES: To evaluate computed tomography fractional flow reserve (FFRCT) values in distal parts of the coronaries in an asymptomatic cohort of marathon runners without any coronary stenosis for potentially false-positive values. METHODS: Ninety-eight asymptomatic male marathon runners (age 53 ± 7 years) were enrolled in a prospective monocentric study and underwent coronary computed tomography angiography (CCTA). CCTA data were analyzed for visual coronary artery stenosis. FFRCT was evaluated in 59 participants without coronary artery stenosis in proximal, mid, and distal coronary sections using an on-site software prototype. RESULTS: In participants without coronary artery stenosis, abnormal FFRCT values ≤ 0.8 in distal segments were found in 22 participants (37%); in 19 participants in the LAD; in 5 participants in the LCX; and in 4 participants in the RCA. Vessel diameters in participants with FFRCT values > 0.80 compared to ≤ 0.80 were 1.6 ± 0.3 mm versus 1.5 ± 0.3 mm for distal LAD (p = 0.025), 1.8 ± 0.3 mm versus 1.6 ± 0.5 mm for distal LCX (p = 0.183), and 2.0 ± 0.4 mm versus 1.5 ± 0.2 mm for distal RCA (p < 0.001). CONCLUSIONS: Abnormal FFRCT values of ≤ 0.8 frequently occurred in distal coronary segments in subjects without any anatomical coronary artery stenosis. This effect is only to some degree explainable by small distal vessel diameters. Therefore, the validity of hemodynamic relevance evaluation using FFRCT in distal coronary artery segment stenosis is reduced. KEY POINTS: • Abnormal FFRCT values (≤ 0.8) occurred in over a third of the subjects in the distal LAD despite the absence of coronary artery stenosis.. • Therefore, the validity of hemodynamic relevance evaluation in distal coronary artery segment stenosis is reduced. • Decision-making based on abnormal FFRCT values in distal vessel sections should be performed with caution and only in combination with visual assessment of the grade of stenosis..


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Masculino , Carrera de Maratón , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X
7.
Pediatr Radiol ; 51(7): 1223-1230, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33544193

RESUMEN

BACKGROUND: The prognostic value of the International Society of Paediatric Oncology European Neuroblastoma Research Network (SIOPEN) skeletal score using 123iodine-metaiodobenzylguanidine (MIBG) has been confirmed for people with high-risk neuroblastoma. Whole-body MRI with diffusion-weighted imaging is used increasingly. OBJECTIVE: To compare the original SIOPEN score and its adaption by diffusion-weighted imaging in high-risk stage 4 neuroblastoma and to evaluate any consequences of score differences on overall survival. MATERIALS AND METHODS: This retrospective observational study included pediatric patients who underwent MIBG scintigraphy and whole-body MRI, including diffusion-weighted imaging, between 2010 and 2015. Semi-quantitative skeletal scores for each exam were calculated independently. A difference of two or more points was defined as clinically relevant and counted as M+ (more in diffusion-weighted imaging) or S+ (more in MIBG). In cases of a negative result in one of the studies, residual disease of 1 point was also rated as relevant. We tested correlation and differences on an exam basis and also grouped by different therapeutic conditions. Overall survival was used to evaluate prognostic relevance. RESULTS: Seventeen children with 25 paired examinations were evaluated. Median MIBG scintigraphy score was 0 (interquartile range [IQR] 0-4, range 0-25) vs. a median whole-body MRI score of 1 (IQR 0-5.5, range 0-35) (P=0.018). A relevant difference between whole-body MRI and MIBG scintigraphy was noted in 14 of the 25 paired examinations (M+: n=9; S+: n=5). After treatment, the median survival of cases with M+ was 14 months (IQR 4-59, range 1-74 months), while S+ cases showed a median survival of 49 months (IQR 36-52, range 36-52 months) (P=0.413). CONCLUSION: The SIOPEN scoring system is feasible for whole-body MRI but might result in slightly higher scores, probably because of MRI's superior spatial resolution. Further studies are necessary to validate any impact on prognosis.


Asunto(s)
Yodo , Neuroblastoma , 3-Yodobencilguanidina , Niño , Humanos , Imagen por Resonancia Magnética , Neuroblastoma/diagnóstico por imagen , Proyectos Piloto , Cintigrafía , Radiofármacos , Imagen de Cuerpo Entero
8.
Eur Radiol ; 30(12): 6645-6652, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32725332

RESUMEN

OBJECTIVES: Computed tomography (CT) imaging of the clavicula displays the reference standard for forensic bone age diagnostics in adolescents and young adults. Consequently, highest efforts on radiation reduction are warranted. Therefore, the aim of this study was to investigate the feasibility of low-dose (LD) CT imaging of the clavicula for age estimation in living adolescents. METHODS: A total of 207 non-contrast chest CT of 144 patients born between 1988 and 2012, performed in 2018 due to various clinical indications, were included in this retrospective study. The mean patient age was 16.9 ± 6.6 years. Patients were divided into a LD (n = 146) and standard-dose (SD; n = 61) group. Image quality, confidence levels, and ossification stages (using the 5-stage classification including the subgroups 2a-3c) were assessed by two radiologists independently. Radiation dose was determined via dosimetry software. RESULTS: Dose simulation with z-axis reduction to depict the clavicula only resulted in a median exposure of 0.1 mSv (IQR: 0.0) in LD compared with 0.9 mSv (IQR: 0.6) in SD (p < 0.001). The median image quality was rated by both readers significantly worse in LD compared with SD on a Likert scale ranging from 1 to 4 with a median of 3 (IQR: 1) versus 4 (IQR: 0; p < 0.001 for both readers). There was an almost perfect agreement for the ossification stages between both readers with a Cohen's kappa of 0.83 (p < 0.001). Median confidence levels of both readers were not significantly different between LD and SD in the decisive subgroups 2a-3c. CONCLUSIONS: Low-dose CT imaging of the clavicula for age estimation in living adolescents is possible without loss of readers' confidence. KEY POINTS: • Radiological bone age diagnostics in young delinquents with unknown exact chronological age is important as the judicial systems differentiate between youths and adults. • Low-dose computed tomography scanning of the medial clavicular joint for forensic age estimation is feasible in living adolescents without loss of readers' confidence. • Sufficient image quality of the medial clavicular joint for forensic bone age diagnostics in living adolescents is achievable using a median dose of 0.1 mSv.


Asunto(s)
Clavícula , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Niño , Humanos , Dosis de Radiación , Cintigrafía , Estudios Retrospectivos , Tórax , Adulto Joven
9.
BMC Med Imaging ; 20(1): 105, 2020 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-32912148

RESUMEN

BACKGROUND: MR imaging of neuroblastic tumors is widely used for assessing the effect of chemotherapy on tumor size. However, there are some concerns that MRI might falsely estimate lesion diameters due to calcification and fibrosis. Therefore, the aim of our study was to compare neuroblastic tumor size based on MRI measurements to histopathology measurements of the resected specimens as standard of reference. METHODS: Inclusion criteria were diagnosis of a neuroblastic tumor, MR imaging within 100 days to surgery and gross total resection without fragmentation of the tumor between 2008 and 2019. Lesion diameters were measured by two radiologists according to RECIST 1.1 in axial plane in T2w turbo spin echo (TSE), diffusion-weighted imaging (DWI), and in T1w pre- and postcontrast sequences. Furthermore, the largest lesion size in three-dimensions was noted. The largest diameter of histopathology measurements of each specimen was used for comparison with MRI. RESULTS: Thirty-seven patients (mean age: 5 ± 4 years) with 38 lesions (neuroblastoma: n = 17; ganglioneuroblastoma: n = 11; ganglioneuroma: n = 10) were included in this retrospective study. There was excellent intra-class correlation coefficient between both readers for all sequences (> 0.9) Tumor dimensions of reader 1 based on axial MRI measurements were significantly smaller with the following median differences (cm): T1w precontrast - 1.4 (interquartile range (IQR): 1.8), T1w postcontrast - 1.0 (IQR: 1.9), T2w TSE: -1.0 (IQR: 1.6), and DWI -1.3 (IQR: 2.2) (p < 0.001 for all sequences). However, the evaluation revealed no significant differences between the three-dimensional measurements and histopathology measurements of the resected specimens regardless of the applied MRI sequence. CONCLUSIONS: Axial MRI based lesion size measurements are significantly smaller than histopathological measurements. However, there was no significant difference between three-dimensional measurements and histopathology measurements of the resected specimens. T2w TSE and T1w postcontrast images provided the lowest deviation and might consequently be preferred for measurements.


Asunto(s)
Ganglioneuroblastoma/diagnóstico por imagen , Ganglioneuroblastoma/patología , Ganglioneuroma/diagnóstico por imagen , Ganglioneuroma/patología , Adolescente , Niño , Preescolar , Imagen de Difusión por Resonancia Magnética , Femenino , Ganglioneuroblastoma/cirugía , Ganglioneuroma/cirugía , Humanos , Imagenología Tridimensional , Lactante , Recién Nacido , Masculino , Variaciones Dependientes del Observador , Estándares de Referencia , Estudios Retrospectivos , Carga Tumoral
11.
Eur Radiol ; 27(10): 4110-4119, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28289942

RESUMEN

OBJECTIVES: To evaluate the effect of structured reports (SRs) in comparison to non-structured narrative free text (NRs) shoulder MRI reports and potential effects of both types of reporting on completeness, readability, linguistic quality and referring surgeons' satisfaction. METHODS: Thirty patients after trauma or with suspected degenerative changes of the shoulder were included in this study (2012-2015). All patients underwent shoulder MRI for further assessment and possible surgical planning. NRs were generated during clinical routine. Corresponding SRs were created using a dedicated template. All 60 reports were evaluated by two experienced orthopaedic shoulder surgeons using a questionnaire that included eight questions. RESULTS: Eighty per cent of the SRs were fully complete without any missing key features whereas only 45% of the NRs were fully complete (p < 0.001). The extraction of information was regarded to be easy in 92% of the SRs and 63% of the NRs. The overall quality of the SRs was rated better than that of the NRs (p < 0.001). CONCLUSIONS: Structured reporting of shoulder MRI improves the readability as well as the linguistic quality of radiological reports, and potentially leads to a higher satisfaction of referring physicians. KEY POINTS: • Structured MRI reports of the shoulder improve readability. • Structured reporting facilitates information extraction. • Referring physicians prefer structured reports to narrative free text reports. • Structured MRI reports of the shoulder can reduce radiologist re-consultations.


Asunto(s)
Informe de Investigación/normas , Hombro/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Mejoramiento de la Calidad , Radiología/normas , Derivación y Consulta , Estudios Retrospectivos , Adulto Joven
12.
Tomography ; 10(2): 255-265, 2024 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-38393288

RESUMEN

This study investigated the efficacy of single-phase dual-energy CT (DECT) in differentiating pulmonary hamartomas from malignant lung lesions using virtual non-contrast (VNC), iodine, and fat quantification. Forty-six patients with 47 pulmonary lesions (mean age: 65.2 ± 12.1 years; hamartomas-to-malignant lesions = 22:25; male: 67%) underwent portal venous DECT using histology, PET-CT and follow-up CTs as a reference. Quantitative parameters such as VNC, fat fraction, iodine density and CT mixed values were statistically analyzed. Significant differences were found in fat fractions (hamartomas: 48.9%; malignancies: 22.9%; p ≤ 0.0001) and VNC HU values (hamartomas: -20.5 HU; malignancies: 17.8 HU; p ≤ 0.0001), with hamartomas having higher fat content and lower VNC HU values than malignancies. CT mixed values also differed significantly (p ≤ 0.0001), but iodine density showed no significant differences. ROC analysis favored the fat fraction (AUC = 96.4%; sensitivity: 100%) over the VNC, CT mixed value and iodine density for differentiation. The study concludes that the DECT-based fat fraction is superior to the single-energy CT in differentiating between incidental pulmonary hamartomas and malignant lesions, while post-contrast iodine density is ineffective for differentiation.


Asunto(s)
Hamartoma , Yodo , Neoplasias Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Tomografía Computarizada por Tomografía de Emisión de Positrones , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Hamartoma/diagnóstico por imagen
13.
Jpn J Radiol ; 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38867035

RESUMEN

PURPOSE: To assess the diagnostic accuracy of ChatGPT-4V in interpreting a set of four chest CT slices for each case of COVID-19, non-small cell lung cancer (NSCLC), and control cases, thereby evaluating its potential as an AI tool in radiological diagnostics. MATERIALS AND METHODS: In this retrospective study, 60 CT scans from The Cancer Imaging Archive, covering COVID-19, NSCLC, and control cases were analyzed using ChatGPT-4V. A radiologist selected four CT slices from each scan for evaluation. ChatGPT-4V's interpretations were compared against the gold standard diagnoses and assessed by two radiologists. Statistical analyses focused on accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), along with an examination of the impact of pathology location and lobe involvement. RESULTS: ChatGPT-4V showed an overall diagnostic accuracy of 56.76%. For NSCLC, sensitivity was 27.27% and specificity was 60.47%. In COVID-19 detection, sensitivity was 13.64% and specificity of 64.29%. For control cases, the sensitivity was 31.82%, with a specificity of 95.24%. The highest sensitivity (83.33%) was observed in cases involving all lung lobes. The chi-squared statistical analysis indicated significant differences in Sensitivity across categories and in relation to the location and lobar involvement of pathologies. CONCLUSION: ChatGPT-4V demonstrated variable diagnostic performance in chest CT interpretation, with notable proficiency in specific scenarios. This underscores the challenges of cross-modal AI models like ChatGPT-4V in radiology, pointing toward significant areas for improvement to ensure dependability. The study emphasizes the importance of enhancing these models for broader, more reliable medical use.

14.
Acad Radiol ; 31(3): 921-928, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37500416

RESUMEN

RATIONALE AND OBJECTIVES: To determine the impact on acquisition time reduction and image quality of a deep learning (DL) reconstruction for accelerated diffusion-weighted imaging (DWI) of the pelvis at 1.5 T compared to standard DWI. MATERIALS AND METHODS: A total of 55 patients (mean age, 61 ± 13 years; range, 27-89; 20 men, 35 women) were consecutively included in this retrospective, monocentric study between February and November 2022. Inclusion criteria were (1) standard DWI (DWIS) in clinically indicated magnetic resonance imaging (MRI) at 1.5 T and (2) DL-reconstructed DWI (DWIDL). All patients were examined using the institution's standard MRI protocol according to their diagnosis including DWI with two different b-values (0 and 800 s/mm2) and calculation of apparent diffusion coefficient (ADC) maps. Image quality was qualitatively assessed by four radiologists using a visual 5-point Likert scale (5 = best) for the following criteria: overall image quality, noise level, extent of artifacts, sharpness, and diagnostic confidence. The qualitative scores for DWIS and DWIDL were compared with the Wilcoxon signed-rank test. RESULTS: The overall image quality was evaluated to be significantly superior in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .05). The extent of noise was evaluated to be significantly less in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .001). No significant differences were found regarding artifacts, lesion detectability, sharpness of organs, and diagnostic confidence (P > .05). Acquisition time for DWIS was 2:06 minutes, and simulated acquisition time for DWIDL was 1:12 minutes. CONCLUSION: DL image reconstruction improves image quality, and simulation results suggest that a reduction in acquisition time for diffusion-weighted MRI of the pelvis at 1.5 T is possible.


Asunto(s)
Aprendizaje Profundo , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Relación Señal-Ruido , Reproducibilidad de los Resultados , Imagen de Difusión por Resonancia Magnética/métodos , Pelvis/diagnóstico por imagen , Artefactos , Imagen por Resonancia Magnética
15.
Eur J Radiol Open ; 12: 100557, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38495213

RESUMEN

Purpose: The objective of this study was to implement a 5-minute MRI protocol for the shoulder in routine clinical practice consisting of accelerated 2D turbo spin echo (TSE) sequences with deep learning (DL) reconstruction at 1.5 and 3 Tesla, and to compare the image quality and diagnostic performance to that of a standard 2D TSE protocol. Methods: Patients undergoing shoulder MRI between October 2020 and June 2021 were prospectively enrolled. Each patient underwent two MRI examinations: first a standard, fully sampled TSE (TSES) protocol reconstructed with a standard reconstruction followed by a second fast, prospectively undersampled TSE protocol with a conventional parallel imaging undersampling pattern reconstructed with a DL reconstruction (TSEDL). Image quality and visualization of anatomic structures as well as diagnostic performance with respect to shoulder lesions were assessed using a 5-point Likert-scale (5 = best). Interchangeability analysis, Wilcoxon signed-rank test and kappa statistics were performed to compare the two protocols. Results: A total of 30 participants was included (mean age 50±15 years; 15 men). Overall image quality was evaluated to be superior in TSEDL versus TSES (p<0.001). Noise and edge sharpness were evaluated to be significantly superior in TSEDL versus TSES (noise: p<0.001, edge sharpness: p<0.05). No difference was found concerning qualitative diagnostic confidence, assessability of anatomical structures (p>0.05), and quantitative diagnostic performance for shoulder lesions when comparing the two sequences. Conclusions: A fast 5-minute TSEDL MRI protocol of the shoulder is feasible in routine clinical practice at 1.5 and 3 T, with interchangeable results concerning the diagnostic performance, allowing a reduction in scan time of more than 50% compared to the standard TSES protocol.

16.
Acad Radiol ; 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38955591

RESUMEN

RATIONALE AND OBJECTIVES: To compare a conventional T1 volumetric interpolated breath-hold examination (VIBE) with SPectral Attenuated Inversion Recovery (SPAIR) fat saturation and a deep learning (DL)-reconstructed accelerated VIBE sequence with SPAIR fat saturation achieving a 50 % reduction in breath-hold duration (hereafter, VIBE-SPAIRDL) in terms of image quality and diagnostic confidence. MATERIALS AND METHODS: This prospective study enrolled consecutive patients referred for upper abdominal MRI from November 2023 to December 2023 at a single tertiary center. Patients underwent upper abdominal MRI with acquisition of non-contrast and gadobutrol-enhanced conventional VIBE-SPAIR (fourfold acceleration, acquisition time 16 s) and VIBE-SPAIRDL (sixfold acceleration, acquisition time 8 s) on a 1.5 T scanner. Image analysis was performed by four readers, evaluating homogeneity of fat suppression, perceived signal-to-noise ratio (SNR), edge sharpness, artifact level, lesion detectability and diagnostic confidence. A statistical power analysis for patient sample size estimation was performed. Image quality parameters were compared by a repeated measures analysis of variance, and interreader agreement was assessed using Fleiss' κ. RESULTS: Among 450 consecutive patients, 45 patients were evaluated (mean age, 60 years ± 15 [SD]; 27 men, 18 women). VIBE-SPAIRDL acquisition demonstrated superior SNR (P < 0.001), edge sharpness (P < 0.001), and reduced artifacts (P < 0.001) with substantial to almost perfect interreader agreement for non-contrast (κ: 0.70-0.91) and gadobutrol-enhanced MRI (κ: 0.68-0.87). No evidence of a difference was found between conventional VIBE-SPAIR and VIBE-SPAIRDL regarding homogeneity of fat suppression, lesion detectability, or diagnostic confidence (all P > 0.05). CONCLUSION: Deep learning reconstruction of VIBE-SPAIR facilitated a reduction of breath-hold duration by half, while reducing artifacts and improving image quality. SUMMARY: Deep learning reconstruction of prospectively accelerated T1 volumetric interpolated breath-hold examination for upper abdominal MRI enabled a 50 % reduction in breath-hold time with superior image quality. KEY RESULTS: 1) In a prospective analysis of 45 patients referred for upper abdominal MRI, accelerated deep learning (DL)-reconstructed VIBE images with spectral fat saturation (SPAIR) showed better overall image quality, with better perceived signal-to-noise ratio and less artifacts (all P < 0.001), despite a 50 % reduction in acquisition time compared to conventional VIBE. 2) No evidence of a difference was found between conventional VIBE-SPAIR and accelerated VIBE-SPAIRDL regarding lesion detectability or diagnostic confidence.

17.
Diagn Interv Imaging ; 104(4): 178-184, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36787419

RESUMEN

PURPOSE: The purpose of this study was to investigate the impact of deep learning accelerated diffusion-weighted imaging (DWIDL) in 1.5-T liver MRI on image quality, sharpness, and diagnostic confidence. MATERIALS AND METHODS: One-hundred patients who underwent liver MRI at 1.5-T including DWI with two different b-values (50 and 800 s/mm²) between February and April 2022 were retrospectively included. There were 54 men and 46 women, with a mean age of 59 ± 14 (SD) years (range: 21-88 years). The single average raw data were retrospectively processed using a deep learning (DL) image reconstruction algorithm leading to a simulated acquisition time of 1 min 28 s for DWIDL as compared to 2 min 31 s for standard DWI (DWIStd) via reduction of signal averages. All DWI datasets were reviewed by four radiologists using a Likert scale ranging from 1-4 using the following criteria: noise level, extent of artifacts, sharpness, overall image quality, and diagnostic confidence. Furthermore, quantitative assessment of noise and signal-to-noise ratio (SNR) was performed via regions of interest. RESULTS: No significant differences were found regarding artifacts and overall image quality (P > 0.05). Noise measurements for the spleen, liver, and erector spinae muscles revealed significantly lower noise for DWIDL versus DWIStd (P < 0.001). SNR measurements in the above-mentioned tissues also showed significantly superior results for DWIDL versus DWIStd for b = 50 s/mm² and ADC maps (all P < 0.001). For b = 800 s/mm², significantly superior results were found for the spleen, right hemiliver, and erector spinae muscles. CONCLUSIONS: DL image reconstruction of liver DWI at 1.5-T is feasible including significant reduction of acquisition time without compromised image quality.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Artefactos , Aprendizaje Profundo , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Hígado/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven , Adulto , Anciano de 80 o más Años
18.
Cancers (Basel) ; 15(3)2023 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-36765539

RESUMEN

OBJECTIVES: Thin-slice prostate MRI might be beneficial for prostate cancer diagnostics. However, prolongation of acquisition time is a major drawback of thin-slice imaging. Therefore, the purpose of this study was to investigate the impact of a thin-slice deep learning accelerated T2-weighted (w) TSE imaging sequence (T2DLR) of the prostate as compared to conventional T2w TSE imaging (T2S). MATERIALS AND METHODS: Thirty patients were included in this prospective study at one university center after obtaining written informed consent. T2S (3 mm slice thickness) was acquired first in three orthogonal planes followed by thin-slice T2DLR (2 mm slice thickness) in axial plane. Acquisition time of axial conventional T2S was 4:12 min compared to 4:37 min for T2DLR. Imaging datasets were evaluated by two radiologists using a Likert-scale ranging from 1-4, with 4 being the best regarding the following parameters: sharpness, lesion detectability, artifacts, overall image quality, and diagnostic confidence. Furthermore, preference of T2S versus T2DLR was evaluated. RESULTS: The mean patient age was 68 ± 8 years. Sharpness of images and lesion detectability were rated better in T2DLR with a median of 4 versus a median of 3 in T2S (p < 0.001 for both readers). Image noise was evaluated to be significantly worse in T2DLR as compared to T2S (p < 0.001 and p = 0.021, respectively). Overall image quality was also evaluated to be superior in T2DLR versus T2S with a median of 4 versus 3 (p < 0.001 for both readers). Both readers chose T2DLR in 29 cases as their preference. CONCLUSIONS: Thin-slice T2DLR of the prostate provides a significant improvement of image quality without significant prolongation of acquisition time.

19.
Eur J Radiol ; 166: 110948, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37481831

RESUMEN

PURPOSE: This study aimed to assess the technical feasibility, the impact on image quality, and the acquisition time (TA) of a new deep-learning-based reconstruction algorithm in diffusion weighted imaging (DWI) of breast magnetic resonance imaging (MRI). METHODS: Retrospective analysis of 55 female patients who underwent breast DWI at 1.5 T. Raw data were reconstructed using a deep-learning (DL) reconstruction algorithm on a subset of the acquired averages, therefore a reduction of TA. Clinically used standard DWI sequence (DWIStd) and the DL-reconstructed images (DWIDL) were compared. Two radiologists rated the image quality of b800 and ADC images, using a Likert-scale from 1 to 5 with 5 being considered perfect image quality. Signal intensities were measured by placing a region of interest (ROI) at the same position in both sequences. RESULTS: TA was reduced by 40 % in DWIDL, compared to DWIStd, DWIDL improved noise and sharpness while maintaining contrast, the level of artifacts, and diagnostic confidence. There were no differences regarding the signal intensity values of the apparent diffusion coefficient (ADC), (p = 0.955), b50-values (p = 0.070) and b800-values (p = 0.415) comparing standard and DL-imaging. Lesion assessment showed no differences regarding the number of lesions in ADC and DWI (both p = 1.000) and regarding the lesion diameter in DWI (p = 0.961;0.972) and ADC (p = 0.961;0.972). CONCLUSIONS: The novel deep-learning-based reconstruction algorithm significantly reduces TA in breast DWI, while improving sharpness, reducing noise, and maintaining a comparable level of image quality, artifacts, contrast, and diagnostic confidence. DWIDL does not influence the quantifiable parameters.


Asunto(s)
Mama , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Aprendizaje Profundo , Imagen de Difusión por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Mama/diagnóstico por imagen , Estudios de Factibilidad
20.
Diagnostics (Basel) ; 13(20)2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37892062

RESUMEN

OBJECTIVES: Hip MRI using standard multiplanar sequences requires long scan times. Accelerating MRI is accompanied by reduced image quality. This study aimed to compare standard two-dimensional (2D) turbo spin echo (TSE) sequences with accelerated 2D TSE sequences with deep learning (DL) reconstruction (TSEDL) for routine clinical hip MRI at 1.5 and 3 T in terms of feasibility, image quality, and diagnostic performance. MATERIAL AND METHODS: In this prospective, monocentric study, TSEDL was implemented clinically and evaluated in 14 prospectively enrolled patients undergoing a clinically indicated hip MRI at 1.5 and 3T between October 2020 and May 2021. Each patient underwent two examinations: For the first exam, we used standard sequences with generalized autocalibrating partial parallel acquisition reconstruction (TSES). For the second exam, we implemented prospectively undersampled TSE sequences with DL reconstruction (TSEDL). Two radiologists assessed the TSEDL and TSES regarding image quality, artifacts, noise, edge sharpness, diagnostic confidence, and delineation of anatomical structures using an ordinal five-point Likert scale (1 = non-diagnostic; 2 = poor; 3 = moderate; 4 = good; 5 = excellent). Both sequences were compared regarding the detection of common pathologies of the hip. Comparative analyses were conducted to assess the differences between TSEDL and TSES. RESULTS: Compared with TSES, TSEDL was rated to be significantly superior in terms of image quality (p ≤ 0.020) with significantly reduced noise (p ≤ 0.001) and significantly improved edge sharpness (p = 0.003). No difference was found between TSES and TSEDL concerning the extent of artifacts, diagnostic confidence, or the delineation of anatomical structures (p > 0.05). Example acquisition time reductions for the TSE sequences of 52% at 3 Tesla and 70% at 1.5 Tesla were achieved. CONCLUSION: TSEDL of the hip is clinically feasible, showing excellent image quality and equivalent diagnostic performance compared with TSES, reducing the acquisition time significantly.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA