Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nephrol Dial Transplant ; 38(5): 1080-1088, 2023 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-35481547

RESUMEN

The world faces a dramatic man-made ecologic disaster and healthcare is a crucial part of this problem. Compared with other therapeutic areas, nephrology care, and especially dialysis, creates an excessive burden via water consumption, greenhouse gas emission and waste production. In this advocacy article from the European Kidney Health Alliance we describe the mutual impact of climate change on kidney health and kidney care on ecology. We propose an array of measures as potential solutions related to the prevention of kidney disease, kidney transplantation and green dialysis. For dialysis, several proactive suggestions are made, especially by lowering water consumption, implementing energy-neutral policies, waste triage and recycling of materials. These include original proposals such as dialysate regeneration, dialysate flow reduction, water distillation systems for dialysate production, heat pumps for unit climatization, heat exchangers for dialysate warming, biodegradable and bio-based polymers, alternative power sources, repurposing of plastic waste (e.g. incorporation in concrete), registration systems of ecologic burden and platforms to exchange ecologic best practices. We also discuss how the European Green Deal offers real potential for supporting and galvanizing these urgent environmental changes. Finally, we formulate recommendations to professionals, manufacturers, providers and policymakers on how this correction can be achieved.


Asunto(s)
Nefrología , Humanos , Diálisis Renal , Fondos de Seguro , Riñón , Soluciones para Diálisis
2.
Int J Mol Sci ; 24(15)2023 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-37569805

RESUMEN

Patients with end-stage kidney disease (ESKD) suffer from high levels of protein-bound uremic toxins (PBUTs) that contribute to various comorbidities. Conventional dialysis methods are ineffective in removing these PBUTs. A potential solution could be offered by a bioartificial kidney (BAK) composed of porous membranes covered by proximal tubule epithelial cells (PTECs) that actively secrete PBUTs. However, BAK development is currently being hampered by a lack of knowledge regarding the cytocompatibility of the dialysis fluid (DF) that comes in contact with the PTECs. Here, we conducted a comprehensive functional assessment of the DF on human conditionally immortalized PTECs (ciPTECs) cultured as monolayers in well plates, on Transwell® inserts, or on hollow fiber membranes (HFMs) that form functional units of a BAK. We evaluated cell viability markers, monolayer integrity, and PBUT clearance. Our results show that exposure to DF did not affect ciPTECs' viability, membrane integrity, or function. Seven anionic PBUTs were efficiently cleared from the perfusion fluid containing a PBUTs cocktail or uremic plasma, an effect which was enhanced in the presence of albumin. Overall, our findings support that the DF is cytocompatible and does not compromise ciPTECs function, paving the way for further advancements in BAK development and its potential clinical application.


Asunto(s)
Fallo Renal Crónico , Toxinas Biológicas , Humanos , Diálisis Renal/métodos , Tóxinas Urémicas , Fallo Renal Crónico/terapia , Fallo Renal Crónico/metabolismo , Riñón/metabolismo , Túbulos Renales Proximales/metabolismo , Soluciones para Diálisis/metabolismo , Toxinas Biológicas/metabolismo
3.
Int J Mol Sci ; 24(17)2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37686004

RESUMEN

Protein-bound uremic toxins (PBUTs) are associated with the progression of chronic kidney disease (CKD) and its associated morbidity and mortality. The conventional dialysis techniques are unable to efficiently remove PBUTs due to their plasma protein binding. Therefore, novel approaches are being developed, but these require validation in animals before clinical trials can begin. We conducted a systematic review to document PBUT concentrations in various models and species. The search strategy returned 1163 results for which abstracts were screened, resulting in 65 full-text papers for data extraction (rats (n = 41), mice (n = 17), dogs (n = 3), cats (n = 4), goats (n = 1), and pigs (n = 1)). We performed descriptive and comparative analyses on indoxyl sulfate (IS) concentrations in rats and mice. The data on large animals and on other PBUTs were too heterogeneous for pooled analysis. Most rodent studies reported mean uremic concentrations of plasma IS close to or within the range of those during kidney failure in humans, with the highest in tubular injury models in rats. Compared to nephron loss models in rats, a greater rise in plasma IS compared to creatinine was found in tubular injury models, suggesting tubular secretion was more affected than glomerular filtration. In summary, tubular injury rat models may be most relevant for the in vivo validation of novel PBUT-lowering strategies for kidney failure in humans.


Asunto(s)
Insuficiencia Renal , Toxinas Biológicas , Humanos , Ratas , Ratones , Animales , Perros , Porcinos , Tóxinas Urémicas , Modelos Animales , Creatinina , Cabras , Indicán
4.
Semin Dial ; 35(6): 481-497, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35650168

RESUMEN

Clinical application of continuous flow peritoneal dialysis (CFPD) has been explored since the 1960s, but despite anticipated clinical benefits, CFPD has failed to gain a foothold in clinical practice, among others due to the typical use of two catheters (or a dual-lumen catheter) and large dialysate volumes required per treatment. Novel systems applying CFPD via the existing single-lumen catheter using rapid dialysate cycling may solve one of these hurdles. Novel on-demand peritoneal dialysate generation systems and sorbent-based peritoneal dialysate regeneration systems may considerably reduce the storage space for peritoneal dialysate and/or the required dialysate volume. This review provides an overview of current evidence on CFPD in vivo. The available (pre)clinical evidence on CFPD is limited to case reports/series with inherently nonuniform study procedures, or studies with a small sample size, short follow-up, and no hard endpoints. Small solute clearance appears to be higher in CFPD compared to conventional PD, in particular at dialysate flows ≥100 mL/min using two single-lumen catheters or a double-lumen catheter. Results of CFPD using rapid cycling via a single-lumen catheter are too preliminary to draw any conclusions. Continuous addition of glucose to dialysate with CFPD appears to be effective in reducing the maximum intraperitoneal glucose concentration while increasing ultrafiltration efficiency (mL/g absorbed glucose). Patient tolerance may be an issue since abdominal discomfort and sterile peritonitis were reported with continuous circulation of the peritoneal dialysate. Thus, well-designed clinical trials of longer duration and larger sample size, in particular applying CFPD via the existing catheter, are urgently required.


Asunto(s)
Diálisis Peritoneal , Diálisis Renal , Humanos , Diálisis Peritoneal/efectos adversos , Diálisis Peritoneal/métodos , Soluciones para Diálisis/farmacología , Peritoneo , Glucosa
5.
Biomed Chromatogr ; 36(5): e5307, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34978088

RESUMEN

Proximal tubular damage is an important prognostic determinant in various chronic kidney diseases (CKDs). Currently available diagnostic methods do not allow for early disease detection and are neither efficient. Indoxyl sulfate (IS) is an endogenous metabolite and protein-bound uremic toxin that is eliminated via renal secretion, but accumulates in plasma during tubular dysfunction. Therefore, it may be suitable as a tubular function marker. To evaluate this, a fast bioanalytical method was developed and validated for IS in various species and a kidney cell line using LC-MS/MS. An isotope-labeled IS potassium salt as an internal standard and acetonitrile (ACN) as a protein precipitant were used for sample pretreatment. The analyte was separated on a Polaris 3 C18-A column by gradient elution using 0.1% formic acid in water and ACN, and detected by negative electrospray ionization in selected reaction monitoring mode. The within-day (≤ 4.0%) and between-day (≤ 4.3%) precisions and accuracies (97.7 to 107.3%) were within the acceptable range. The analyte showed sufficient stability at all conditions investigated. Finally, applying this assay, significantly higher plasma and lower urine concentrations of IS were observed in mice with diabetic nephropathy with tubular damage, which encourages validation toward its use as a biomarker.


Asunto(s)
Indicán , Espectrometría de Masas en Tándem , Animales , Cromatografía Liquida/métodos , Riñón , Ratones , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/métodos
6.
Am J Physiol Renal Physiol ; 320(3): F518-F524, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33522412

RESUMEN

Monitoring renal function is a vital part of kidney research involving rats. The laborious measurement of glomerular filtration rate (GFR) with administration of exogenous filtration markers does not easily allow serial measurements. Using an in-house database of inulin clearances, we developed and validated a plasma creatinine- and plasma urea-based equation to estimate GFR in a large cohort of male rats [development cohort n = 325, R2 = 0.816, percentage of predictions that fell within 30% of the true value (P30) = 76%] that had high accuracy in the validation cohort (n = 116 rats, R2 = 0.935, P30 = 79%). The equation was less accurate in rats with nonsteady-state creatinine, in which the equation should therefore not be used. In conclusion, applying this equation facilitates easy and repeatable estimates of GFR in rats.NEW & NOTEWORTHY This is the first equation, that we know of, which estimates glomerular filtration rate in rats based on a single measurement of body weight, plasma creatinine, and plasma urea.


Asunto(s)
Adamantano/análogos & derivados , Creatinina/sangre , Dipéptidos/farmacología , Tasa de Filtración Glomerular/efectos de los fármacos , Plasma , Urea , Adamantano/farmacología , Angiotensina II/farmacología , Animales , Riñón/metabolismo , Pruebas de Función Renal , Masculino , Plasma/metabolismo , Ratas , Urea/metabolismo
7.
Artif Organs ; 45(11): 1422-1428, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34251693

RESUMEN

A major challenge for the development of a wearable artificial kidney (WAK) is the removal of urea from the spent dialysate, as urea is the waste solute with the highest daily molar production and is difficult to adsorb. Here we present results on glucose degradation products (GDPs) formed during electrooxidation (EO), a technique that applies a current to the dialysate to convert urea into nitrogen, carbon dioxide, and hydrogen gas. Uremic plasma and peritoneal effluent were dialyzed for 8 hours with a WAK with and without EO-based dialysate regeneration. Samples were taken regularly during treatment. GDPs (glyoxal, methylglyoxal, and 3-deoxyglucosone) were measured in EO- and non-EO-treated fluids. Glyoxal and methylglyoxal concentrations increased 26- and 11-fold, respectively, in uremic plasma (at [glucose] 7 mmol/L) and 209- and 353-fold, respectively, in peritoneal effluent (at [glucose] 100 mmol/L) during treatment with EO, whereas no change was observed in GDP concentrations during dialysate regeneration without EO. EO for dialysate regeneration in a WAK is currently not safe due to the generation of GDPs which are not biocompatible.


Asunto(s)
Técnicas Electroquímicas , Glucosa/metabolismo , Riñones Artificiales , Urea/sangre , Soluciones para Diálisis/química , Humanos , Diálisis Renal , Dispositivos Electrónicos Vestibles
8.
Am J Physiol Renal Physiol ; 319(2): F162-F170, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32475132

RESUMEN

A system for sorbent-assisted peritoneal dialysis (SAPD) was designed to continuously recirculate dialysate via a tidal mode using a single lumen peritoneal catheter with regeneration of spent dialysate by means of sorbent technology. We hypothesize that SAPD treatment will maintain a high plasma-to-dialysate concentration gradient and increase the mass transfer area coefficient of solutes. Thereby, the SAPD system may enhance clearance while reducing the number of exchanges. Application is envisaged at night as a bedside device (12 kg, nighttime system). A wearable system (2.0 kg, daytime system) may further enhance clearance during the day. Urea, creatinine, and phosphate removal were studied with the daytime and nighttime system (n = 3 per system) by recirculating 2 liters of spent peritoneal dialysate via a tidal mode (mean flow rate: 50 and 100 mL/min, respectively) for 8 h in vitro. Time-averaged plasma clearance over 24 h was modeled assuming one 2 liter exchange/day, an increase in mass transfer area coefficient, and 0.9 liters ultrafiltration/day. Urea, creatinine, and phosphate removal was 33.2 ± 4.1, 5.3 ± 0.5, and 6.2 ± 1.8 mmol, respectively, with the daytime system and 204 ± 28, 10.3 ± 2.4, and 11.4 ± 2.1 mmol, respectively, with the nighttime system. Time-averaged plasma clearances of urea, creatinine and phosphate were 9.6 ± 1.1, 9.6 ± 1.7, and 7.0 ± 0.9 mL/min, respectively, with the nighttime system and 10.8 ± 1.1, 13.4 ± 1.8, and 9.7 ± 1.6 mL/min, respectively, with the daytime and nighttime system. SAPD treatment may improve removal of uremic toxins compared with conventional peritoneal dialysis, provided that peritoneal mass transport will increase.


Asunto(s)
Creatinina/sangre , Soluciones para Diálisis/farmacología , Diálisis Peritoneal , Urea/sangre , Humanos , Cinética , Peritoneo/metabolismo , Fosfatos/sangre , Ultrafiltración/métodos
9.
BMC Nephrol ; 21(1): 448, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-33109094

RESUMEN

BACKGROUND: Patients on continuous ambulatory peritoneal dialysis (PD) are encouraged to warm dialysate to 37 °C before peritoneal infusion; main international PD guidelines do not provide specific recommendation, and patients generally warm dialysate batches partially or do not warm them at all. Warming of dialysate is a time-consuming procedure, not free from potential risks (i.e. degradation of glucose), and should be justified by a clear clinical benefit. METHODS: We designed a single blind randomized controlled trial where 18 stable PD patients were randomized to receive a peritoneal equilibration test either with dialysate at a controlled temperature of 37 °C (intervention group) or with dialysate warmed with conventional methods (control group). Primary end-point was a higher peritoneal creatinine clearance in patients in the intervention group. RESULTS: Patients in the intervention group did not show a significantly higher peritoneal creatinine clearance when compared to the control group (6.38 ± 0.52 ml/min vs 5.65 ± 0.37 ml/min, p = 0.2682). Similar results were obtained for urea peritoneal clearance, mass transfer area coefficient of creatinine and urea. There were no significant differences in total abdominal discomfort questionnaire score, blood pressure and body temperature between the two groups. CONCLUSIONS: Using peritoneal dialysate at different temperatures without causing significant side effects to patients appears feasible. We report a lack of benefit of warming peritoneal dialysate to 37 °C on peritoneal clearances; future PD guidelines should not reinforce this recommendation. TRIAL REGISTRATION: NCT04302649, ClinicalTrials.gov ; date of registration 10/3/2020 (retrospectively registered).


Asunto(s)
Soluciones para Diálisis , Fallo Renal Crónico/terapia , Diálisis Peritoneal Ambulatoria Continua/métodos , Temperatura , Creatinina/metabolismo , Femenino , Enfermedades Gastrointestinales/etiología , Humanos , Fallo Renal Crónico/metabolismo , Masculino , Diálisis Peritoneal Ambulatoria Continua/efectos adversos , Método Simple Ciego , Urea/metabolismo
10.
Mol Pharm ; 16(11): 4551-4562, 2019 11 04.
Artículo en Inglés | MEDLINE | ID: mdl-31525064

RESUMEN

Indoxyl sulfate (IxS), a highly albumin-bound uremic solute, accumulates in chronic kidney disease (CKD) due to reduced renal clearance. This study was designed to specifically investigate the role of human serum albumin (HSA) in IxS renal secretion via organic anion transporter 1 (OAT1) in a microfluidic system and subsequently apply quantitative translation of in vitro data to predict extent of change in IxS renal clearance in CKD stage IV relative to healthy. Conditionally immortalized human proximal tubule epithelial cells overexpressing OAT1 were incubated with IxS (5-200 µM) in the HSA-free medium or in the presence of either HSA or CKD-modified HSA. IxS uptake in the presence of HSA resulted in more than 20-fold decrease in OAT1 affinity (Km,u) and 37-fold greater in vitro unbound intrinsic clearance (CLint,u) versus albumin-free condition. In the presence of CKD-modified albumin, Km,u increased four-fold and IxS CLint,u decreased almost seven-fold relative to HSA. Fold-change in parameters exceeded differences in IxS binding between albumin conditions, indicating additional mechanism and facilitating role of albumin in IxS OAT1-mediated uptake. Quantitative translation of IxS in vitro OAT1-mediated CLint,u predicted a 60% decrease in IxS renal elimination as a result of CKD, in agreement with the observed data (80%). The findings of the current study emphasize the role of albumin in IxS transport via OAT1 and explored the impact of modifications in albumin on renal excretion via active secretion in CKD. For the first time, this study performed quantitative translation of transporter kinetic data generated in a novel microfluidic in vitro system to a clinically relevant setting. Knowledge gaps and future directions in quantitative translation of renal drug disposition from microphysiological systems are discussed.


Asunto(s)
Transporte Biológico/fisiología , Indicán/metabolismo , Insuficiencia Renal Crónica/metabolismo , Albúmina Sérica Humana/metabolismo , Línea Celular , Humanos , Túbulos Renales Proximales/metabolismo , Cinética , Proteínas de Transporte de Membrana/metabolismo , Microfluídica , Proteína 1 de Transporte de Anión Orgánico/metabolismo
11.
Arch Toxicol ; 93(12): 3397-3418, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31664498

RESUMEN

The kidney is frequently involved in adverse effects caused by exposure to foreign compounds, including drugs. An early prediction of those effects is crucial for allowing novel, safe drugs entering the market. Yet, in current pharmacotherapy, drug-induced nephrotoxicity accounts for up to 25% of the reported serious adverse effects, of which one-third is attributed to antimicrobials use. Adverse drug effects can be due to direct toxicity, for instance as a result of kidney-specific determinants, or indirectly by, e.g., vascular effects or crystals deposition. Currently used in vitro assays do not adequately predict in vivo observed effects, predominantly due to an inadequate preservation of the organs' microenvironment in the models applied. The kidney is highly complex, composed of a filter unit and a tubular segment, together containing over 20 different cell types. The tubular epithelium is highly polarized, and the maintenance of this polarity is critical for optimal functioning and response to environmental signals. Cell polarity is dependent on communication between cells, which includes paracrine and autocrine signals, as well as biomechanic and chemotactic processes. These processes all influence kidney cell proliferation, migration, and differentiation. For drug disposition studies, this microenvironment is essential for prediction of toxic responses. This review provides an overview of drug-induced injuries to the kidney, details on relevant and translational biomarkers, and advances in 3D cultures of human renal cells, including organoids and kidney-on-a-chip platforms.


Asunto(s)
Enfermedades Renales/inducido químicamente , Riñón/efectos de los fármacos , Pruebas de Toxicidad/métodos , Animales , Biomarcadores Farmacológicos/análisis , Humanos , Técnicas In Vitro , Riñón/fisiopatología , Pruebas de Toxicidad/instrumentación
12.
Am J Physiol Renal Physiol ; 315(5): F1385-F1397, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29993277

RESUMEN

The key to success in developing a wearable dialysis device is a technique to safely and efficiently regenerate and reuse a small volume of dialysate in a closed-loop system. In a hemodialysis model in goats, we explored whether urea removal by electro-oxidation (EO) could be effectively and safely applied in vivo. A miniature dialysis device was built, containing 1 or 2 "EO units," each with 10 graphite electrodes, with a cumulative electrode surface of 585 cm2 per unit. The units also contained poly(styrene-divinylbenzene) sulfonate beads, FeOOH beads, and activated carbon for respective potassium, phosphate, and chlorine removal. Urea, potassium, and phosphate were infused to create "uremic" conditions. Urea removal was dependent on total electrode surface area [removal of 8 mmol/h (SD 1) and 16 mmol/h (SD 2) and clearance of 12 ml/min (SD 1) and 20 ml/min (SD 3) with 1 and 2 EO units, respectively] and plasma urea concentration but not on flow rate. Extrapolating urea removal with 2 EO units to 24 h would suffice to remove daily urea production, but for intermittent dialysis, additional units would be required. EO had practically no effects on potassium and phosphate removal or electrolyte balance. However, slight ammonium releasewas observed, and some chlorine release at higher dialysate flow rates. Minor effects on acid-base balance were observed, possibly partly due to infusion of chloride. Mild hemolysis occurred, which seemed related to urea infusion. In conclusion, clinically relevant urea removal was achieved in vivo by electro-oxidation. Efficacy and safety testing in a large-animal model with uremia is now indicated.


Asunto(s)
Soluciones para Diálisis/metabolismo , Diálisis Renal/instrumentación , Urea/sangre , Uremia/terapia , Dispositivos Electrónicos Vestibles , Equilibrio Ácido-Base , Desequilibrio Ácido-Base/etiología , Desequilibrio Ácido-Base/fisiopatología , Animales , Creatinina/sangre , Modelos Animales de Enfermedad , Diseño de Equipo , Cabras , Hemólisis , Miniaturización , Modelos Biológicos , Oxidación-Reducción , Fosfatos/sangre , Potasio/sangre , Diálisis Renal/efectos adversos , Factores de Tiempo , Uremia/sangre , Uremia/fisiopatología , Vigilia
13.
Nephrol Dial Transplant ; 33(6): 906-913, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29106652

RESUMEN

Hypoalbuminemia is a major risk factor for morbidity and mortality in dialysis patients. With increasing interest in highly permeable membranes and convective therapies to improve removal of middle molecules, transmembrane albumin loss increases accordingly. Currently, the acceptable upper limit of albumin loss for extracorporeal renal replacement therapies is unknown. In theory, any additional albumin loss should be minimized because it may contribute to hypoalbuminemia and adversely affect the patient's prognosis. However, hypoalbuminemia-associated mortality may be a consequence of inflammation and malnutrition, rather than low albumin levels per se. The purpose of this review is to give an overview of albumin handling with different extracorporeal renal replacement strategies. We conclude that the acceptable upper limit of dialysis-related albumin loss remains unknown. Whether enhanced middle molecule removal outweighs the potential adverse effects of increased albumin loss with novel highly permeable membranes and convective therapies is yet to be determined.


Asunto(s)
Hipoalbuminemia/etiología , Inflamación/etiología , Fallo Renal Crónico/terapia , Desnutrición Proteico-Calórica/etiología , Diálisis Renal/efectos adversos , Albúmina Sérica/deficiencia , Humanos , Pronóstico , Factores de Riesgo
14.
Nephrol Dial Transplant ; 32(6): 951-959, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27220758

RESUMEN

BACKGROUND: Patients on standard intermittent haemodialysis suffer from strong fluctuations in plasma potassium and phosphate. Prolonged dialysis with a wearable device, based on continuous regeneration of a small volume of dialysate using ion exchangers, could moderate these fluctuations and offer increased clearance of these electrolytes. We report in vivo results on the efficacy of potassium and phosphate adsorption from a wearable dialysis device. We explore whether equilibration of ion exchangers at physiological Ca 2+ , Mg 2+ and hypotonic NaCl can prevent calcium/magnesium adsorption and net sodium release, respectively. Effects on pH and HCO3- were studied. METHODS: Healthy goats were instrumented with a central venous catheter and dialysed. Potassium and phosphate were infused to achieve plasma concentrations commonly observed in dialysis patients. An adsorption cartridge containing 80 g sodium poly(styrene-divinylbenzene) sulphonate and 40 g iron oxide hydroxide beads for potassium and phosphate removal, respectively, was incorporated in a dialysate circuit. Sorbents were equilibrated and regenerated with a solution containing NaCl, CaCl 2 and MgCl 2 . Blood was pumped over a dialyser and dialysate was recirculated over the adsorption cartridge in a countercurrent direction. RESULTS: Potassium and phosphate adsorption was 7.7 ± 2.7 and 4.9 ± 1.3 mmol in 3 h, respectively. Adsorption capacity remained constant during consecutive dialysis sessions and increased with increasing K + and PO43-. Equilibration at physiological Ca 2+ and Mg 2+ prevented net adsorption, eliminating the need for post-cartridge calcium and magnesium infusion. Equilibration at hypotonic NaCl prevented net sodium release Fe 2+ and arterial pH did not change. Bicarbonate was adsorbed, which could be prevented by equilibrating at HCO3- 15 mM. CONCLUSION: We demonstrate clinically relevant, concentration-dependent, pH-neutral potassium and phosphate removal in vivo with small volumes of regenerable ion exchangers in our prototype wearable dialysis device. Application of the selected ion exchangers for potassium and phosphate removal in a wearable dialysis device appears to be effective with a low-risk profile.


Asunto(s)
Fosfatos/aislamiento & purificación , Potasio/aislamiento & purificación , Diálisis Renal/instrumentación , Adsorción , Animales , Bicarbonatos/sangre , Equipo Reutilizado , Compuestos Férricos/química , Cabras , Humanos , Intercambio Iónico , Magnesio/sangre , Fosfatos/sangre , Potasio/sangre , Mejoramiento de la Calidad , Diálisis Renal/métodos , Sodio/química
15.
Growth Factors ; 34(3-4): 149-58, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27686612

RESUMEN

AIMS: Connective tissue growth factor (CTGF) plays a key role in tissue fibrogenesis and growing evidence indicates a pathogenic role in cardiovascular disease. Aim of this study is to investigate the association of connective tissue growth factor (CTGF/CCN2) with cardiovascular risk and mortality in patients with manifest vascular disease. METHODS AND RESULTS: Plasma CTGF was measured by ELISA in a prospective cohort study of 1227 patients with manifest vascular disease (mean age 59.0 ± 9.9 years). Linear regression analysis was performed to quantify the association between CTGF and cardiovascular risk factors. Results are expressed as beta (ß) regression coefficients with 95% confidence intervals (CI). The relation between CTGF and the occurrence of new cardiovascular events and mortality was assessed with Cox proportional hazard analysis. Adjustments were made for potential confounding factors. Plasma CTGF was positively related to total cholesterol (ß 0.040;95%CI 0.013-0.067) and LDL cholesterol (ß 0.031;95%CI 0.000-0.062) and inversely to glomerular filtration rate (ß -0.004;95%CI -0.005 to -0.002). CTGF was significantly lower in patients with cerebrovascular disease. During a median follow-up of 6.5 years (IQR 5.3-7.4) 131 subjects died, 92 experienced an ischemic cardiac complication and 45 an ischemic stroke. CTGF was associated with an increased risk of new vascular events (HR 1.21;95%CI 1.04-1.42), ischemic cardiac events (HR 1.41;95%CI 1.18-1.67) and all-cause mortality (HR 1.18;95%CI 1.00-1.38) for every 1 nmol/L increase in CTGF. No relation was observed between CTGF and the occurrence of ischemic stroke. CONCLUSIONS: In patients with manifest vascular disease, elevated plasma CTGF confers an increased risk of new cardiovascular events and all-cause mortality.


Asunto(s)
Aterosclerosis/sangre , Isquemia Encefálica/sangre , Factor de Crecimiento del Tejido Conjuntivo/sangre , Accidente Cerebrovascular/sangre , Anciano , Aterosclerosis/epidemiología , Aterosclerosis/mortalidad , Isquemia Encefálica/epidemiología , Isquemia Encefálica/mortalidad , Estudios de Casos y Controles , Colesterol/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/mortalidad
16.
Artif Organs ; 38(12): 998-1006, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24750025

RESUMEN

A major challenge for a wearable dialysis device is removal of urea, as urea is difficult to adsorb while daily production is very high. Electro-oxidation (EO) seems attractive because electrodes are durable, small, and inexpensive. We studied the efficacy of urea oxidation, generation of chlorine by-products, and their removal by activated carbon (AC). EO units were designed. Three electrode materials (platinum, ruthenium oxide, and graphite) were compared in single pass experiments using urea in saline solution. Chlorine removal by AC in series with EO by graphite electrodes was tested. Finally, urea-spiked bovine blood was dialyzed and dialysate was recirculated in a dialysate circuit with AC in series with an EO unit containing graphite electrodes. Platinum electrodes degraded more urea (21 ± 2 mmol/h) than ruthenium oxide (13 ± 2 mmol/h) or graphite electrodes (13 ± 1 mmol/h). Chlorine generation was much lower with graphite (13 ± 4 mg/h) than with platinum (231 ± 22 mg/h) or ruthenium oxide electrodes (129 ± 12 mg/h). Platinum and ruthenium oxide electrodes released platinum (4.1 [3.9-8.1] umol/h) and ruthenium (83 [77-107] nmol/h), respectively. AC potently reduced dialysate chlorine levels to < 0.10 mg/L. Urea was removed from blood by EO at constant rate (9.5 ± 1.0 mmol/h). EO by graphite electrodes combined with AC shows promising urea removal and chlorine release complying with Association for the Advancement of Medical Instrumentation standards, and may be worth further exploring for dialysate regeneration in a wearable system.


Asunto(s)
Diálisis Renal/instrumentación , Urea/sangre , Animales , Bovinos , Soluciones para Diálisis , Electrodos , Oxidación-Reducción
17.
Clin Kidney J ; 17(9): sfae259, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39301271

RESUMEN

Background: Dialysis modalities and their various treatment schedules result from complex compromises ('trade-offs') between medical, financial, technological, ergonomic, and ecological factors. This study targets summarizing the mutual influence of these trade-offs on (trans)portable, wearable, or even (partially) implantable haemodialysis (HD) systems, identify what systems are in development, and how they might improve quality of life (QoL) for patients with kidney failure. Methods: HD as defined by international standard IEC 60601-2-16 was applied on a PUBMED database query regarding (trans)portable, wearable, and (partly) implantable HD systems. Out of 159 search results, 24 were included and scanned for specific HD devices and/or HD systems in development. Additional information about weight, size, and development status was collected by the internet and/or contacting manufacturers. International airplane hand baggage criteria formed the boundary between transportable and portable. Technology readiness levels (TRLs) were assigned by combining TRL scales from the European Union and NATO medical staff. Results: The query revealed 13 devices/projects: seven transportable (six TRL9, one TRL5); two portable (one TRL6-7, one TRL4); two wearable (one TRL6, one frozen); and two partly implantable (one TRL4-5, one TRL2-3). Discussion: Three main categories of technical approaches were distinguished: single-pass, dialysate regenerating, and implantable HD filter with extracorporeal dialysate regeneration (in climbing order of mobility). Conclusions: Kidneys facilitate mobility by excreting strongly concentrated waste solutes with minimal water loss. Mimicking this kidney function can increase HD system mobility. Dialysate-regenerating HD systems are enablers for portability/wearability and, combined with durable implantable HD filters (once available), they may enable HD without needles or intravascular catheters. However, lack of funding severely hampers progress.

18.
Nephrol Dial Transplant ; 28(9): 2364-71, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23825104

RESUMEN

BACKGROUND: Continuous dialysis could provide benefit by constant removal of potassium and phosphate. This study investigates the suitability of specific potassium and phosphate sorbents for incorporation in an extracorporeal device by capacity and regenerability testing. METHODS: Capacity testing was performed in uraemic plasma. Regenerability was tested for potassium sorbents, with adsorption based on cationic exchange for sodium, with 0.1 M and 1.0 M NaCl. To regenerate phosphate sorbents, with adsorption based on anionic exchange, 0.1 M and 1.0 M NaHCO3 and NaOH were used. Subsequently, sodium polystyrene divinylbenzene sulphonate (RES-A) and iron oxide hydroxide (FeOOH) beads were incorporated in a cartridge for testing in bovine blood using a recirculating blood circuit and a dialysis circuit separated by a high-flux dialyzer (dynamic setup). Preloading was tested to assess whether this could limit calcium and magnesium adsorption. RESULTS: In the batch-binding assays, zirconium phosphate most potently adsorbed potassium (0.44 ± 0.05 mmol/g) and RES-A was the best regenerable potassium sorbent (92.9 ± 5.7% with 0.1 M NaCl). Zirconium oxide hydroxide (ZIR-hydr) most potently adsorbed phosphate (0.23 ± 0.05 mmol/g) and the polymeric amine sevelamer carbonate was the best regenerable sorbent (85.7 ± 5.2% with 0.1 M NaHCO3). In the dynamic setup, a potassium adsorption of 10.72 ± 2.06 mmol in 3 h was achieved using 111 g of RES-A and a phosphate adsorption of 4.73 ± 0.53 mmol in 3 h using 55 g of FeOOH. Calcium and magnesium preloading was shown to reduce the net adsorption in 3 h from 3.57 ± 0.91 to -0.29 ± 1.85 and 1.02 ± 0.05 to -0.31 ± 0.18 mmol, respectively. CONCLUSION: RES-A and FeOOH are suitable, regenerizable sorbents for potassium and phosphate removal in dialysate regeneration. Use of zirconium carbonate and ZIR-hydr may further increase phosphate adsorption, but may compromise sorbent regenerability. Use of polymeric amines for phosphate adsorption may enhance sorbent regenerability. Calcium and magnesium preloading considerably reduced net adsorption of these ions.


Asunto(s)
Compuestos Férricos/química , Fosfatos/química , Potasio/química , Diálisis Renal/instrumentación , Diálisis Renal/métodos , Adsorción , Animales , Bovinos , Técnicas In Vitro , Óxidos/química , Fosfatos/sangre , Fosfatos/aislamiento & purificación , Potasio/sangre , Potasio/aislamiento & purificación
19.
Nat Rev Nephrol ; 19(8): 481-490, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37277461

RESUMEN

Haemodialysis is life sustaining but expensive, provides limited removal of uraemic solutes, is associated with poor patient quality of life and has a large carbon footprint. Innovative dialysis technologies such as portable, wearable and implantable artificial kidney systems are being developed with the aim of addressing these issues and improving patient care. An important challenge for these technologies is the need for continuous regeneration of a small volume of dialysate. Dialysate recycling systems based on sorbents have great potential for such regeneration. Novel dialysis membranes composed of polymeric or inorganic materials are being developed to improve the removal of a broad range of uraemic toxins, with low levels of membrane fouling compared with currently available synthetic membranes. To achieve more complete therapy and provide important biological functions, these novel membranes could be combined with bioartificial kidneys, which consist of artificial membranes combined with kidney cells. Implementation of these systems will require robust cell sourcing; cell culture facilities annexed to dialysis centres; large-scale, low-cost production; and quality control measures. These challenges are not trivial, and global initiatives involving all relevant stakeholders, including academics, industrialists, medical professionals and patients with kidney disease, are required to achieve important technological breakthroughs.


Asunto(s)
Riñones Artificiales , Dispositivos Electrónicos Vestibles , Humanos , Calidad de Vida , Diálisis Renal , Soluciones para Diálisis
20.
Am J Kidney Dis ; 59(5): 619-27, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22342213

RESUMEN

BACKGROUND: Connective tissue growth factor (CTGF) has a key role in the pathogenesis of renal and cardiac fibrosis. Its amino-terminal fragment (N-CTGF), the predominant form of CTGF detected in plasma, has a molecular weight in the middle molecular range (18 kDa). However, it is unknown whether N-CTGF is a uremic retention solute that accumulates in chronic kidney disease (CKD) due to decreased renal clearance and whether it can be removed by hemodiafiltration. STUDY DESIGN: 4 observational studies in patients and 2 pharmacokinetic studies in rodents. SETTING & PARTICIPANTS: 4 single-center studies. First study (cross-sectional): 88 patients with CKD not receiving kidney replacement therapy. Second study (cross-sectional): 23 patients with end-stage kidney disease undergoing low-flux hemodialysis. Third study: 9 kidney transplant recipients before and 6 months after transplant. Fourth study: 11 low-flux hemodialysis patients and 12 hemodiafiltration patients before and after one dialysis session. PREDICTOR: First, second, and third study: (residual) glomerular filtration rate (GFR). Fourth study: dialysis modality. OUTCOMES & MEASUREMENTS: Plasma (N-)CTGF concentrations, measured by enzyme-linked immunosorbent assay. RESULTS: In patients with CKD, we observed an independent association between plasma CTGF level and estimated GFR (ß = -0.72; P < 0.001). In patients with end-stage kidney disease, plasma CTGF level correlated independently with residual kidney function (ß = -0.55; P = 0.046). Successful kidney transplant resulted in a decrease in plasma CTGF level (P = 0.008) proportional to the increase in estimated GFR. Plasma CTGF was not removed by low-flux hemodialysis, whereas it was decreased by 68% by a single hemodiafiltration session (P < 0.001). Pharmacokinetic studies in nonuremic rodents confirmed that renal clearance is the major elimination route of N-CTGF. LIMITATIONS: Observational studies with limited number of patients. Fourth study: nonrandomized, evaluation of the effect of one session; randomized longitudinal study is warranted. CONCLUSION: Plasma (N-)CTGF is eliminated predominantly by the kidney, accumulates in CKD, and is decreased substantially by a single hemodiafiltration session.


Asunto(s)
Factor de Crecimiento del Tejido Conjuntivo/sangre , Tasa de Filtración Glomerular/fisiología , Enfermedades Renales/sangre , Fallo Renal Crónico/sangre , Riñón/fisiopatología , Adulto , Anciano , Animales , Enfermedad Crónica , Factor de Crecimiento del Tejido Conjuntivo/farmacocinética , Estudios Transversales , Femenino , Hemodiafiltración , Humanos , Enfermedades Renales/fisiopatología , Enfermedades Renales/terapia , Fallo Renal Crónico/fisiopatología , Fallo Renal Crónico/terapia , Trasplante de Riñón , Masculino , Ratones , Ratones Endogámicos C57BL , Persona de Mediana Edad , Modelos Animales , Ratas , Ratas Endogámicas WKY , Diálisis Renal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA