Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Orthop Surg Traumatol ; 33(8): 3703-3709, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37311829

RESUMEN

PURPOSE: Quality of reduction is of paramount importance after acetabular fracture and is best assessed on computed tomography (CT). A recently proposed measurement technique for assessment of step and gap displacement is reproducible but has not been validated. The purpose of this study is to validate a well-established measurement technique against known displacements and to determine if it can be used with low dose CT. METHODS: Posterior wall acetabular fractures were created in 8 cadaveric hips and fixed at known step and gap displacements. CT was performed at multiple radiation doses for each hip. Four surgeons measured step and gap displacement for each hip at all doses, and the measurements were compared to known values. RESULTS: There were no significant differences in measurements across surgeons, and all measurements were found to have positive agreement. Measurement error < 1.5 mm was present in 58% of gap measurements and 46% of step measurements. Only for step measurements at a dose of 120 kVp did we observe a statistically significant measurement error. There was a significant difference in step measurements made by those with greater and those with fewer years in practice. CONCLUSION: Our study suggests this technique is valid and accurate across all doses. This is important as it may reduce the amount of radiation exposure for patients with acetabular fractures.


Asunto(s)
Fracturas Óseas , Fracturas de Cadera , Fracturas de la Columna Vertebral , Humanos , Acetábulo/cirugía , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Estudios Retrospectivos , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/cirugía , Tomografía Computarizada por Rayos X/métodos , Fijación de Fractura
2.
Eur J Orthop Surg Traumatol ; 32(8): 1501-1508, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34557963

RESUMEN

PURPOSE: To assess the accuracy of radiographs in detecting the lateral plateau involvement of medial tibial plateau fractures as well as describe the impact of CT on preoperative planning for this specific fracture morphology. METHODS: Radiograph and CT imaging of patients with a Schatzker type IV tibial plateau fractures (AO/OTA 41-B1.2, B1.3 h, B2.2. B3.2, and B3.3) between January 2013 and July 2017 were reviewed by three trauma fellowship-trained orthopedic surgeons to identify fractures of the medial condyle with an intact anterolateral articular surface. RESULTS: Lateral plateau involvement was identified in 16 (37%) radiographs and 26 (61%) CT images (p = 0.051). Radiographic detection of lateral plateau involvement demonstrated a sensitivity of 62% and specificity of 100%, and radiographs were able to predict the recommendation for surgical intervention for lateral plateau involvement with a positive predictive value (PPV) of 75% and a negative predictive value (NPV) of 60% compared to recommendations based on CT imaging. Radiographs predicted a need for a separate surgical approach with PPV of 63% and NPV of 70% when compared to recommendations based on CT images. CONCLUSIONS: Radiographs are reliable in ruling in lateral plateau involvement of medial plateau fractures, but occult lateral articular extension may only be identified in CT imaging for some cases. Surgical planning may be impacted by CT imaging for this fracture morphology, but further study is warranted to evaluate the correlation between preoperative planning and clinical outcomes. LEVEL OF EVIDENCE: III.


Asunto(s)
Fracturas de la Tibia , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Articulación de la Rodilla , Tibia
3.
J Chromatogr A ; 945(1-2): 65-81, 2002 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-11860146

RESUMEN

Flow inhomogeneity and axial development in low-pressure chromatographic columns have been studied by magnetic resonance imaging velocimetry. The columns studied included (a) an 11.7-mm I.D. column packed with either 50 microm diameter porous polyacrylamide, or 99 or 780 microm diameter impermeable polystyrene beads, and (b) a 5-mm I.D. column commercially packed with 10 microm polymeric beads. The packing methods included gravity settling, slurry packing, ultrasonication, and dry packing with vibration. The magnetic resonance method used averaged apparent fluid velocity over both column cross-sections and fluid displacements greater than one particle diameter and hence permits assessment of macroscopic flow non-uniformities. The results confirm that now non-uniformities induced by the conical distributor of the 11.7-mm I.D. column or the presence of voids at the column entrance relax on a length scale of the column radius. All of the 11.7-mm I.D. columns examined exhibit near wall channeling within a few particle diameters of the wall. The origins of this behavior are demonstrated by imaging of the radial dependence of the local porosity for a column packed with 780 microm beads. Columns packed with the 99-microm beads exhibit reduced flow in a region extending from ten to three-to-five particle diameters from the wall. This velocity reduction is consistent with a reduced porosity of 0.35 in this region as compared to approximately 0.43 in the bulk of the column. Ultrasonicated and dry-packed columns exhibit enhanced flow in a region located between approximately eight and 20 particle diameters from the wall. This enhancement maybe caused by packing density inhomogeneity and/or particle size segregation caused by vibration during the packing process. No significant non-uniformities on length scales of 20 microm or greater were observed in the commercially packed column packed with 10 microm particles.


Asunto(s)
Cromatografía Liquida/métodos , Cromatografía Liquida/instrumentación , Imagen por Resonancia Magnética , Presión
4.
Magn Reson Imaging ; 20(5): 389-94, 2002 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12206863

RESUMEN

Recently, a new type of cancer treatment has been introduced that combines pulsed electric fields (PEF) with anticancer drugs. The proposed mode of action is that PEF create transient pores in the membranes which allow entry of drugs into the cells. This method increases cytotoxicity of some anticancer drugs like bleomycin (BLM) by 2-3 orders of magnitude, which, in turn, reduces systemic drug dosage without decreasing efficacy. In the present study, magnetic resonance imaging (MRI) was used to determine changes in apparent water self-diffusion coefficients (ADC) and spin-lattice (T(1)) and spin-spin (T(2)) relaxation times that occur in an animal laryngeal tumor (HEp-2 cells) model with BLM delivered by PEF. A Bruker 14 Tesla (600 MHz) wide-bore spectrometer with micro-imaging capability was used to generate all the data. Mice carrying approximately 8 mm tumors were treated with several combinations of drug and PEF. All measurements were made on tumor samples excised from mice 24 and 48 hours after treatment with (i) saline, intratumor injection (i.t.), (ii) BLM, i.t., (iii) saline with PEF, and (iv) BLM, i.t., followed by PEF. Although T(1) does not differ between the controls (i, ii, and iii) and full treatment (iv) 6.72 +/- 0.20 s vs. 6.31 +/- 1.7 s, T(2) for (iv) at 24 hours is significantly different from the controls 52.4 +/- 0.91 ms vs. 46.5 +/- 1.54 ms. T(2) differences between treatment and controls disappear at 48 hours. ADC increases significantly from 24 to 48 hours (7.31 +/- 0.16 x 10(-6) to 8.28 +/- 0.28 x 10(-6) cm(2)/sec, p = 0.05). Longer T(2) values may reflect early apoptosis and tumor death when the tumor is structurally less dense. Higher ADC's, associated with the periphery of the tumors and the central region, may indicate loose structural organization and necrosis resulting from the combination treatment.


Asunto(s)
Antibióticos Antineoplásicos/farmacología , Bleomicina/farmacología , Electroporación , Neoplasias Laríngeas/patología , Neoplasias Laríngeas/terapia , Imagen por Resonancia Magnética , Animales , Ratones , Ratones Desnudos , Trasplante de Neoplasias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA