1.
Circulation ; 141(6): 429-439, 2020 02 11.
Artículo en Inglés | MEDLINE | ID: mdl-31941373

RESUMEN

BACKGROUND: Insight into type 5 long QT syndrome (LQT5) has been limited to case reports and small family series. Improved understanding of the clinical phenotype and genetic features associated with rare KCNE1 variants implicated in LQT5 was sought through an international multicenter collaboration. METHODS: Patients with either presumed autosomal dominant LQT5 (N = 229) or the recessive Type 2 Jervell and Lange-Nielsen syndrome (N = 19) were enrolled from 22 genetic arrhythmia clinics and 4 registries from 9 countries. KCNE1 variants were evaluated for ECG penetrance (defined as QTc >460 ms on presenting ECG) and genotype-phenotype segregation. Multivariable Cox regression was used to compare the associations between clinical and genetic variables with a composite primary outcome of definite arrhythmic events, including appropriate implantable cardioverter-defibrillator shocks, aborted cardiac arrest, and sudden cardiac death. RESULTS: A total of 32 distinct KCNE1 rare variants were identified in 89 probands and 140 genotype positive family members with presumed LQT5 and an additional 19 Type 2 Jervell and Lange-Nielsen syndrome patients. Among presumed LQT5 patients, the mean QTc on presenting ECG was significantly longer in probands (476.9±38.6 ms) compared with genotype positive family members (441.8±30.9 ms, P<0.001). ECG penetrance for heterozygous genotype positive family members was 20.7% (29/140). A definite arrhythmic event was experienced in 16.9% (15/89) of heterozygous probands in comparison with 1.4% (2/140) of family members (adjusted hazard ratio [HR] 11.6 [95% CI, 2.6-52.2]; P=0.001). Event incidence did not differ significantly for Type 2 Jervell and Lange-Nielsen syndrome patients relative to the overall heterozygous cohort (10.5% [2/19]; HR 1.7 [95% CI, 0.3-10.8], P=0.590). The cumulative prevalence of the 32 KCNE1 variants in the Genome Aggregation Database, which is a human database of exome and genome sequencing data from now over 140 000 individuals, was 238-fold greater than the anticipated prevalence of all LQT5 combined (0.238% vs 0.001%). CONCLUSIONS: The present study suggests that putative/confirmed loss-of-function KCNE1 variants predispose to QT prolongation, however, the low ECG penetrance observed suggests they do not manifest clinically in the majority of individuals, aligning with the mild phenotype observed for Type 2 Jervell and Lange-Nielsen syndrome patients.


Asunto(s)
Síndrome de QT Prolongado , Penetrancia , Canales de Potasio con Entrada de Voltaje/genética , Sistema de Registros , Adolescente , Adulto , Muerte Súbita Cardíaca , Cardioversión Eléctrica , Electrocardiografía , Femenino , Paro Cardíaco/genética , Paro Cardíaco/mortalidad , Paro Cardíaco/fisiopatología , Paro Cardíaco/terapia , Humanos , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/mortalidad , Síndrome de QT Prolongado/fisiopatología , Síndrome de QT Prolongado/terapia , Masculino , Persona de Mediana Edad
2.
Cardiol Young ; 28(5): 621-631, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29345602

RESUMEN

Potentially fatal arrhythmias add to the mental health challenges of adolescence. This systematic review sought to summarise current knowledge regarding the mental health of adolescents and pre-adolescents diagnosed with inherited arrhythmia syndromes. Searches combining psychological problems with inherited cardiac arrhythmia diagnoses identified 16 studies with paediatric (<18 years) inherited arrhythmia patients. All studies were cross-sectional; 8/16 required an implantable cardioverter defibrillator. Methods were quantitative (n=11), qualitative (n=4), or mixed (n=1), with 14-100% of participants having an inherited arrhythmia syndrome. Mean/median age in 13/16 studies was 12-16 years. Patients and parents reported lower quality of life, particularly in relation to physical function, social relationships, restriction of peer activities, bodily pain, and mental and emotional health. Self-perceptions and behaviour were similar to healthy populations. Rates of anxiety and depression (15-33% of these patients) were not increased in these studies where patients were assessed 2+ years after diagnosis. Higher mental health risk occurred among patients who have a diagnosed sibling, those with cardiomyopathy, and those who report decreased quality of life. Mental health research among youth with inherited arrhythmias is extremely limited and of low quality. Data, primarily from patients 2-4 years after diagnosis or treatment with an implantable cardioverter defibrillator, indicate that quality of life may be decreased and 15-33% experience mental health issues. Future research is required to examine the mental health and quality of life of paediatric patients with inherited arrhythmia syndromes, whether or not they have an implantable cardioverter defibrillator, from time of diagnosis.


Asunto(s)
Arritmias Cardíacas , Salud Mental , Calidad de Vida/psicología , Medición de Riesgo , Adolescente , Factores de Edad , Arritmias Cardíacas/congénito , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/psicología , Niño , Salud Global , Humanos , Tasa de Supervivencia/tendencias , Síndrome
3.
J Mol Cell Cardiol ; 92: 52-62, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26801742

RESUMEN

BACKGROUND: Inherited autosomal dominant mutations in cardiac sodium channels (NaV1.5) cause various arrhythmias, such as long QT syndrome and Brugada syndrome. Although dozens of mutations throughout the protein have been reported, there are few reported mutations within a voltage sensor S4 transmembrane segment and few that are homozygous. Here we report analysis of a novel lidocaine-sensitive recessive mutation, p.R1309H, in the NaV1.5 DIII/S4 voltage sensor in a patient with a complex arrhythmia syndrome. METHODS AND RESULTS: We expressed the wild type or mutant NaV1.5 heterologously for analysis with the patch-clamp and voltage clamp fluorometry (VCF) techniques. p.R1309H depolarized the voltage-dependence of activation, hyperpolarized the voltage-dependence of inactivation, and slowed recovery from inactivation, thereby reducing the channel availability at physiologic membrane potentials. Additionally, p.R1309H increased the "late" Na(+) current. The location of the mutation in DIIIS4 prompted testing for a gating pore current. We observed an inward current at hyperpolarizing voltages that likely exacerbates the loss-of-function defects at resting membrane potentials. Lidocaine reduced the gating pore current. CONCLUSIONS: The p.R1309H homozygous NaV1.5 mutation conferred both gain-of-function and loss-of-function effects on NaV1.5 channel activity. Reduction of a mutation-induced gating pore current by lidocaine suggested a therapeutic mechanism.


Asunto(s)
Arritmias Cardíacas/genética , Síndrome de Brugada/genética , Sistema de Conducción Cardíaco/fisiopatología , Canal de Sodio Activado por Voltaje NAV1.5/genética , Arritmias Cardíacas/tratamiento farmacológico , Arritmias Cardíacas/fisiopatología , Síndrome de Brugada/tratamiento farmacológico , Síndrome de Brugada/fisiopatología , Trastorno del Sistema de Conducción Cardíaco , Humanos , Lactante , Lidocaína/administración & dosificación , Masculino , Potenciales de la Membrana/genética , Mutación , Canal de Sodio Activado por Voltaje NAV1.5/química , Canal de Sodio Activado por Voltaje NAV1.5/metabolismo , Técnicas de Placa-Clamp
4.
Crit Care Med ; 42(11): 2358-69, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24810533

RESUMEN

OBJECTIVE: Controversies regarding the process and timing of the determination of death for controlled organ donation after circulatory death persist. This study assessed the feasibility of conducting a prospective, observational study of continuous monitoring of vital signs for 30 minutes after the clinical determination of death in five Canadian ICUs. Waveform data were analyzed. DESIGN: Prospective observational cohort study. SETTING: One pediatric and four adult Canadian ICUs. PATIENTS: One month of age or older, admitted to the ICU, and for whom a consensual decision to withdraw life-sustaining therapies had been made, with an anticipation of imminent death. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Invasive arterial blood pressure, electrocardiogram, and oxygen saturation plethysmography activity were recorded and reviewed for 30 minutes after declaration of death. Feasibility was assessed (recruitment, consent rate, protocol compliance, and staff satisfaction). Of 188 subjects screened over 16 months, 41 subjects were enrolled (87% consent rate). Data collection was complete for 30 subjects (73% protocol compliance). In four subjects, arterial blood pressure resumed following cessation of activity. The longest period of cessation of arterial blood pressure before resumption was 89 seconds. The duration of resumed activity ranged from 1 to 172 seconds. No cases of sustained resumption of arterial blood pressure activity were recorded, and no instances of clinical autoresuscitation were reported. In nearly all patients (27 of 30), electrocardiogram activity continued after the disappearance of arterial blood pressure. CONCLUSIONS: This is the first observational study to prospectively collect waveform data for 30 minutes after the declaration of death. A future larger study may support initial data suggesting that circulatory function does not resume after more than 89 seconds of absence. Furthermore, persistence of cardiac electrical activity with the documented absence of circulation may not be relevant to declaration of death.


Asunto(s)
Apoyo Vital Cardíaco Avanzado/métodos , Paro Cardíaco/mortalidad , Paro Cardíaco/terapia , Obtención de Tejidos y Órganos/organización & administración , Signos Vitales/fisiología , Privación de Tratamiento , Adulto , Canadá , Reanimación Cardiopulmonar/métodos , Niño , Preescolar , Estudios de Cohortes , Muerte , Estudios de Factibilidad , Femenino , Humanos , Lactante , Recién Nacido , Unidades de Cuidados Intensivos , Masculino , Proyectos Piloto , Estudios Prospectivos , Control de Calidad , Factores de Tiempo
7.
Pediatr Crit Care Med ; 11(1): 133-8, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19581822

RESUMEN

OBJECTIVE: To summarize the practical operation of temporary pacemakers in common use pertinent to the intensivist caring for the postcardiac patient. Pacemaker therapy is commonly required in the postoperative period after congenital cardiac surgery. DATA SYNTHESIS: Monitoring the hemodynamic status and availability of equipment for resuscitation is always important in any patient requiring a temporary pacemaker. Two important scenarios to consider in the pediatric intensive care unit are: 1) the patient in whom pacing has been initiated to optimize cardiac function; and 2) the patient without demonstrable spontaneous electrical activity or with extreme bradycardia. A number of different models of temporary pacemaker are available. Management of the child requiring cardiac pacing requires an understanding of the indications for pacing, a thorough knowledge of the available pacemaker, and an ability to troubleshoot problems. CONCLUSIONS: As the most common arrhythmias post congenital cardiac surgery involve either rate or conduction abnormalities, temporary pacemaker systems are a common form of electrical therapy in the postoperative period.


Asunto(s)
Arritmias Cardíacas/cirugía , Marcapaso Artificial , Cuidados Posoperatorios , Falla de Equipo , Cardiopatías Congénitas/cirugía , Humanos , Unidades de Cuidado Intensivo Pediátrico , Marcapaso Artificial/normas
8.
Ann Noninvasive Electrocardiol ; 14(2): 165-75, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19419402

RESUMEN

BACKGROUND: An electrocardiogram has been proposed to screen for prolonged QT interval that may predispose infants to sudden death in the first year of life. Understanding the reliability of QT interval measurement will inform the design of a screening program. METHODS: Three pediatric cardiologists measured the QT/RR intervals on 60 infant electrocardiograms (median age 46 days), from leads II, V5 and V6 on three separate occasions, 7 days apart, according to a standard protocol. The QTc was corrected by Bazett's (QTcB), Fridericia's (QT(CFrid)), and Hodges' (QTcH) formulae. Intraobserver and interobserver reliability were assessed by intraclass correlation coefficients (ICC), limits of agreement and repeatability coefficients for single, average of two and average of three measures. Agreement for QTc prolongation (> 440 msec) was assessed by kappa coefficients. RESULTS: QT interval intraobserver ICC was 0.86 and repeatability coefficient was 25.9 msec; interobserver ICC increased from 0.88 for single observations to 0.94 for the average of 3 measurements and repeatability coefficients decreased from 22.5 to 16.7 msec. For QTcB, intraobserver ICC was 0.67, and repeatability was 39.6 msec. Best interobserver reliability for QTcB was for the average of three measurements (ICC 0.83, reproducibility coefficient 25.8 msec), with further improvement for QTcH (ICC 0.92, reproducibility coefficient 16.69 msec). Maximum interobserver kappa for prolonged QTc was 0.77. Misclassification around specific cut points occurs because of the repeatability coefficients. CONCLUSIONS: Uncorrected QT measures are more reliable than QTcB and QT(CFrid). An average of three independent measures provides the most reliable QT and QTc measurements, with QTcH better than QTcB.


Asunto(s)
Electrocardiografía/métodos , Síndrome de QT Prolongado/diagnóstico , Femenino , Frecuencia Cardíaca , Humanos , Lactante , Recién Nacido , Síndrome de QT Prolongado/fisiopatología , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
9.
Psychiatry Res ; 272: 756-764, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30832196

RESUMEN

Several studies suggest that anxiety disorders (AD) involve dysregulation of the autonomic nervous system (ANS) and hypothalamic-pituitary (HPA) axis. However, it is unknown if alterations in these biological systems are premorbid markers of AD risk or a state-dependent feature of anxiety. This study examined ANS and HPA-axis response to a laboratory stressor in healthy child offspring of parents with (n = 55) and without (n = 98) a history of AD. High frequency heart rate variability (HF-HRV) was assessed during sitting and standing baseline conditions and during a speech task where participants remained standing. Salivary cortisol was measured at baseline and at 15, 30, 45 and 60 min post-speech. Subjective anxiety was assessed with a visual analogue scale. Children of parents with AD displayed reduced HRV and a blunted cortisol response to the speech task compared to children of non-anxious parents. No risk group effect was found for anxiety ratings. These preliminary data suggest that healthy children of anxious parents exhibit altered stress reactivity to an acute laboratory stressor. Further research is needed to confirm findings and identify mechanisms that may account for altered self-regulation processes to a stressor in children at familial risk for AD.


Asunto(s)
Trastornos de Ansiedad/metabolismo , Trastornos de Ansiedad/psicología , Hijo de Padres Discapacitados/psicología , Padres/psicología , Estrés Psicológico/metabolismo , Estrés Psicológico/psicología , Adolescente , Trastornos de Ansiedad/diagnóstico , Niño , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Hidrocortisona/metabolismo , Sistema Hipotálamo-Hipofisario/metabolismo , Masculino , Sistema Hipófiso-Suprarrenal/metabolismo , Saliva/metabolismo , Estrés Psicológico/diagnóstico
10.
J Clin Epidemiol ; 61(4): 394-401, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18313565

RESUMEN

OBJECTIVE: To investigate the reporting of the analysis of interobserver and intra-observer variability within clinical research studies from five high-impact cardiology journals published in 2005. STUDY DESIGN AND SETTING: A cross-sectional study using a combined electronic and manual search identified 180 of 511 eligible articles that reported the assessment of observer variability. Sixty of these were randomly selected for detailed review. RESULTS: The proportion of the 60 studies reporting interobserver variability, intra-observer variability, or both were 27%, 17%, and 53%, respectively. The reported methodological design of interobserver and intra-observer analyses included a specific protocol in 42% and 33%, identified observers as independent in 31% and 17%, as blinded in 50% and 31%, and identified a prior statistical plan in only 33% and 36%, respectively. Pearson correlation was the most reported measure for continuous variables, and the methods of Bland and Altman were reported in 15% of interobserver and 14% of intra-observer studies, respectively. For categorical variables, a kappa statistic was reported in 82% and 80%, respectively. CONCLUSION: Reliability assessment is hampered by unclear and incomplete reporting of interobserver and intra-observer analysis. For continuous variables, inappropriate methods were most frequently reported as being done.


Asunto(s)
Cardiología/estadística & datos numéricos , Difusión de la Información/métodos , Revisión de la Investigación por Pares , Ensayos Clínicos como Asunto/estadística & datos numéricos , Estudios Transversales , Humanos , Variaciones Dependientes del Observador , Edición , Proyectos de Investigación