Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Neurourol Urodyn ; 40(6): 1616-1624, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34082470

RESUMEN

OBJECTIVE: To evaluate the factor age at the surgery on long-term postoperative outcomes in patients with postprostatectomy incontinence (PPI) after AdVance XP transobturator male sling implantation. METHODS: A total of 115 male patients with PPI, who had undergone AdVance XP sling implantation, were included. Patients had PPI with endoscopically confirmed good sphincteric-contractility and a positive coaptive response. Kruskal-Wallis test with Dunn post-hoc tests were used to analyze the postoperative outcome differences between the patient groups aged less than 66, 66-75, and over greater than 75 years. Outcome measures were the 24 h pad test, the number of daily pads used, the International Consultation on Incontinence Questionnaire short form (ICIQ-SF), International Quality of Life Score (IQOL), Patient Global Impression of Improvement (PGI-I), International Index of Erectile Function-5 (IIEF-5), International Prostate Symptom Score (IPSS), and Visual Analog Scale scores. Observation time points were 3, 6, 12, 24, 36, 48, 60, and 84 months after surgery. RESULTS: Between the age groups, there was no difference in the success rate of the procedure (defined as 0 pads/24 h and less than 5 g in the 24-h pad test) at any point in time. Subjective parameters measures using the ICIQ-SF, PGI-I, IQOL, and IPSS scores showed no differences between the two cohorts. Only erectile function (IIEF-5 score) was lower in older patients in comparison to the cohort aged less than 66 years (p < 0.05 at 3, 6, 12, 24, 36, and 48 months). CONCLUSIONS: The present study complements the European multicentre AdVance XP follow-up study. Here, we show that age at surgery does not affect the objective success, subjective success, or the complication rate. Thus, we do not recommend factoring in chronological age into surgical selection criteria for the AdVance XP implantation.


Asunto(s)
Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo , Anciano , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/cirugía , Pronóstico , Estudios Prospectivos , Prostatectomía/efectos adversos , Calidad de Vida , Resultado del Tratamiento , Incontinencia Urinaria de Esfuerzo/cirugía
2.
Urol Int ; 105(5-6): 421-427, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33517334

RESUMEN

OBJECTIVE: The aim of this study was to assess the security, value, and efficacy of the second-generation AdVance male sling XP (Boston Scientific®), after implementation in 2010 with advantageous modifications in the sling structure and needle shape, in a prospective multicenter long-term follow-up study. METHODS: In total, 115 patients were included. Exclusion criteria were earlier incontinence (UI) surgery, nocturnal UI, former radiotherapy, or night-time incontinence. We also excluded patients with a functional urethra <1 cm in a preoperatively performed repositioning test. A consistent 24-h pad test, International Quality of Life (IQOL) score, visual analog pain scale (VAS), International Consultation-Incontinence Questionnaire (ICIQ-UI SF), International Index of Erectile Function (IIEF-5), International Prostate Symptom Score (IPSS), and Patient Global Impression of Improvement (PGI-I) scores were requested postoperatively. RESULTS: The 24-month follow-up (114 patients) revealed 64.0% cured and 28.8% improved patients. Mean urine loss was reduced significantly to 19.0 g (p < 0.001). A mean PGI score of 1.5 and a mean VAS score of 0.2 were obtained. The 60-month follow-up (59 patients) revealed 57.6% cured and 25.4% improved patients. Mean urine loss was reduced significantly to 18.3 g (p < 0.001). A mean PGI score of 1.6 and a mean VAS score of 0.2 were obtained. CONCLUSIONS: The AdVance XP displays excellent continence results and secure effectiveness over a 5-year period. Moreover, these data are demonstrating low complication rates and improved quality of life in the long-term use of AdVance XP.


Asunto(s)
Complicaciones Posoperatorias/cirugía , Prostatectomía , Cabestrillo Suburetral , Incontinencia Urinaria/cirugía , Anciano , Anciano de 80 o más Años , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Cabestrillo Suburetral/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
3.
Neurourol Urodyn ; 38(7): 1973-1978, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31297894

RESUMEN

OBJECTIVE: To evaluate the efficacy and safety of the AdVance XP male sling in a midterm follow-up for the treatment of male urinary incontinence in a selected patient cohort. MATERIALS AND METHODS: In all, 115 patients with postprostatectomy incontinence were prospectively enrolled. A previous endoscopic evaluation of a sufficient coaptive zone in the repositioning test was mandatory. Patients with urine leakage in supine position or previous incontinence surgery were excluded. Postoperatively a standardized 24-hour pad test and pad usage were evaluated. To compare pre- and postoperative continence status nonparametric t test was used. A P-value of <.05 was seen as statistically significant. RESULTS: Median preoperative urine loss in the 24-hour pad test was 272 g (min. 42-max. 1600) and was significantly improved at any point in follow-up. Success was defined as 0 pads per day and a maximum of 5 g in the 24-hour pad test. After a follow-up of 48 months, 71.7% of the patients were cured, whereas 15.0% of patients had an improved continence situation and 13.3% were classified as failed. Mean urine loss decreased significantly to 24.4 g (P ≤ .001). No severe intra- or postoperative complications are to be reported. Median follow-up was 4.2 years. CONCLUSIONS: A stable effectiveness in a selected patient cohort can also be demonstrated in an extended follow-up. The complication rates are low and no late postoperative complications occurred, indicating the safety of the procedure.


Asunto(s)
Complicaciones Posoperatorias/cirugía , Prostatectomía/efectos adversos , Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo/cirugía , Anciano , Anciano de 80 o más Años , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Periodo Posoperatorio , Estudios Prospectivos , Resultado del Tratamiento , Incontinencia Urinaria de Esfuerzo/etiología
4.
BJU Int ; 119(4): 626-630, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27862836

RESUMEN

OBJECTIVES: To evaluate the efficacy and safety of the AdVance XP® sling (Boston Scientific, formerly American Medical Systems) in male stress urinary incontinence (SUI) after radical prostatectomy in a prospective multicentre study, as in recent years several studies have shown the effectiveness and safety of the AdVance sling for treating male SUI and in 2010 the second-generation AdVance XP was introduced with several changes in the sling design and a new needle shape. PATIENTS AND METHODS: In all, 115 patients were included. Patients with nocturnal UI, previous UI surgery, previous radiotherapy and a coaptive zone of <1 cm in the preoperative repositioning test were excluded. Postoperatively, a standardised 24-h pad test, quality-of-life scores [International Quality of Life score (IQOL) and International Consultation on Incontinence Questionnaire short form (ICIQ-UI SF)], visual analogue scale (VAS) for pain, five-item version of the International Index of Erectile Function (IIEF-5), International Prostate Symptom Score (IPSS) and Patient Global Impression of Improvement (PGI-I) score, were performed. All patients with a 0-5 g pad test were defined as cured and improved with a reduction of urine loss of >50%. All others were classified as failures. Significance analysis was performed using the Wilcoxon test. RESULTS: The mean (median) preoperative urine loss in the 24-h pad test was 272.0 (272.0) g. After a follow-up of 3 months (114 patients), 64.9% of the patients were cured and 31.6% had an improved continence status. The mean urine loss decreased significantly to 34.9 g (P < 0.001), with a mean VAS score of 0.5, and mean PGI-I of 1.5. After a follow-up of 24 months (80 patients), 68.8% of the patients were cured and 22.5% had improved. The mean urine loss decreased significantly to 19.1 g (P < 0.001), with a mean VAS score of 0.3, and mean PGI-I of 1.5. After a follow-up of 36 months (47 patients), 66.0% of the patients were cured and 23.4% had improved. The mean urine loss decreased significantly to 21.8 g (P < 0.001), with a mean VAS score of 0.0, and mean PGI-I of 1.6. The mean IQOL and ICIQ-UI SF improved significantly (both P < 0.001) after 36 months. There were no significant postoperative changes in IIEF-5 and IPSS. No intraoperative and no long-term complications occurred. No erosion or explanations occurred. CONCLUSION: The AdVance XP shows good and stable effectiveness and low complication rates even at a mid-term follow-up of up to 36 months.


Asunto(s)
Complicaciones Posoperatorias/cirugía , Prostatectomía/efectos adversos , Neoplasias de la Próstata/cirugía , Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo/cirugía , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/fisiopatología , Estudios Prospectivos , Neoplasias de la Próstata/fisiopatología , Calidad de Vida , Resultado del Tratamiento , Incontinencia Urinaria de Esfuerzo/etiología , Incontinencia Urinaria de Esfuerzo/fisiopatología
5.
World J Urol ; 34(7): 1025-30, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26582060

RESUMEN

PURPOSE: For the treatment of persistent post-prostatectomy incontinence (PPI), several surgical treatment options including male slings are available. In 2010, the second generation of the retrourethral male sling Advance, AdVanceXP, was introduced. Aim of the study was to examine in a prospective multicentre study the outcome of AdVanceXP in the treatment of PPI. METHODS: Ninety-four patients were treated with AdVanceXP. Patients with nocturnal incontinence, previous incontinence surgery, with coaptive zone <1 cm and irradiated patients were excluded. Measurements included: daily pad usage, 24-h pad weight test, post-operative pain in the visual analogue scale, International Quality of Life questionnaire, International Consultation on Incontinence Questionnaire short form, IEEF5 and Patient Global Impression of Improvement. Adverse events were recorded. All patients with no pads and 0-5 g in the 24-h pad test were defined as cured and those with a reduction in urine loss >50 % as improved. RESULTS: Preoperatively, the median 24-h pad weight test was 274 g and daily pad usage was 3. At 1-year follow-up, 66.3 % of patients could be classified as cured and 25.3 % as improved. After 2 years, 73.1 % could be classified as cured and 19.6 % as improved. Urine loss decreased (p < 0.001), and quality of life improved significantly (p < 0.001). Mean PGI was 1.5 after 1 year and 1.4 after 2 years. Majority of complications were minor. No intraoperative complications and five serious post-operative events occurred (grade IIIB complications). No explantation was necessary. CONCLUSIONS: AdVanceXP, when correctly indicated, shows good effectiveness and low complication rates after up to 2 years.


Asunto(s)
Complicaciones Posoperatorias/cirugía , Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo/cirugía , Anciano , Anciano de 80 o más Años , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Prostatectomía/efectos adversos , Diseño de Prótesis , Factores de Tiempo , Incontinencia Urinaria de Esfuerzo/etiología
6.
Neurourol Urodyn ; 35(8): 875-881, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-26397171

RESUMEN

Context Stress urinary incontinence (SUI) after radical prostatectomy (RP) continues to be a significant problem with several implications including patient quality of life and other critical postoperative outcomes. Objectives To report the results in terms of efficacy (pad count, 24 hr pad test, QOL questionnaires) and safety (complication rate and type of complications) of all surgical devices approved for the treatment of SUI after RP. Evidence Acquisition A systematic review was conducted in accordance with the PRISMA Statement. A literature search was carried out through the PubMed/Medline, SCOPUS, and Web of Science databases using the keywords "incontinence," "radical prostatectomy," and "'treatment". Inclusion criteria were: number of patients higher than 30, mean follow up longer than 12 months and definition of a successful outcome as the use of 0 to 1 safety pads a day. Evidence Synthesis 113 papers underwent primary review. 51 papers met the inclusion criteria with a total sample size of 4022 patients. Efficacy (0-1 safety pads) was on average 65.7% for AUS, 48.2% for Invance Sling, 48.8% for Advance Sling, 64.2% for ProACT. Twenty four hour pad test and QOL questionnaires were respectively available only in 4 and 18 studies. The overall complication rate was 19.43% for AUS, 7.4% for Invance Sling, 12.3% for Advance Sling, 12.3% for ProACT. Authors' Conclusions Due to the poor overall quality of available studies, it was impossible to identify or refute clinically important differences between the alternative surgical procedures. Although our data seems to suggest that AUS has the highest efficacy in the treatment of SUI following RP it is also associated with the highest complication rate, but this may be due to the longest follow up. Larger rigorous trials are needed in order to support this evidence. Neurourol. Urodynam. 35:875-881, 2016. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Complicaciones Posoperatorias/cirugía , Prostatectomía/efectos adversos , Incontinencia Urinaria de Esfuerzo/etiología , Incontinencia Urinaria de Esfuerzo/cirugía , Procedimientos Quirúrgicos Urológicos Masculinos/métodos , Humanos , Masculino , Resultado del Tratamiento , Procedimientos Quirúrgicos Urológicos Masculinos/efectos adversos
7.
World J Urol ; 33(8): 1143-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25312682

RESUMEN

PURPOSE: To evaluate the impact of the retrourethral transobturator sling (RTS) on pelvic floor muscle function (PFMF) and whether preoperative PFMF is associated with RTS outcome. METHODS: Between May 2008 and December 2010, 59 consecutive men with postprostatectomy stress urinary incontinence (PSUI) underwent PFMF assessment before RTS and 6 months thereafter in a prospective cohort study. The assessments included demographic and clinical characteristics, and quality of life (QoL) questionnaires. PFMF was evaluated by digital rectal examination on the modified 6-point Oxford scale and by surface electromyography. The primary outcome measurement was success after RTS defined as PSUI cure with use of no or one dry "security" pad. For secondary outcome, PFMF, 1-h pad test, and impact of PSUI on QoL were evaluated. Uni- and multivariate analyses were performed. RESULTS: After 6-month follow-up, the cure, improvement (>50 % pad reduction) and failure rates were 50 % (29/58 patients), 24 % (14/58 patients) and 26 % (15/58 patients), respectively. Significant improvement of QoL, clinical and PFMF parameters occurred after RTS. On multivariate analysis, weak PFMF (OR 86.29) and greater muscle fatigue (OR 3.31) were significant independent predictors of RTS failure. The final model demonstrated good calibration (p = 0.882) and excellent discriminative ability (0.942, 95 % CI 0.883-1.0) to predict success after RTS. CONCLUSIONS: PFMF improved significantly after RTS procedure. Higher muscle fatigue and weak PFMF were independent predictors of RTS failure. Digital rectal evaluation of PFMF is a simple and reliable clinical tool, which can be used by urologists in daily routine to predict the RTS outcome.


Asunto(s)
Fatiga Muscular , Diafragma Pélvico/fisiopatología , Complicaciones Posoperatorias/cirugía , Prostatectomía , Calidad de Vida , Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo/cirugía , Anciano , Estudios de Cohortes , Tacto Rectal , Electromiografía , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/fisiopatología , Estudios Prospectivos , Resultado del Tratamiento , Incontinencia Urinaria de Esfuerzo/fisiopatología
8.
World J Urol ; 32(6): 1375-83, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24452450

RESUMEN

PURPOSE: To investigate whether differences in the anatomy and dynamics of the pelvic floor (PF) in patients after radical prostatectomy (RP) depicted on magnetic resonance imaging (MRI) are associated with continence status. METHODS: In the prospective designed study, 24 patients with post-prostatectomy stress urinary incontinence were enrolled. Additionally, 10 continent patients after RP were matched for age, body mass index and perioperative parameters. All patients underwent continence assessment and MRI (TrueFISP sequence; TR 4.57 ms; TE 2.29 ms; slice thickness 7 mm; FOV 270 mm) 12 months after RP. Images were analyzed for membranous urethra length (MUL), angle of the membranous urethra (AMU), severity of periurethral/urethral fibrosis, lifting of the levator ani muscle, lowering of the posterior bladder wall (BPW), bladder neck (BN) and external urinary sphincter (EUS), and symphyseal rotation of these structures during the Valsalva maneuver and voiding. RESULTS: Compared to continent controls, incontinent patients showed a significant wider AMU during voiding (p = 0.002) and more pronounced lowering of the BN and EUS (p < 0.001). No differences between the groups were found in symphyseal rotation of the analyzed structures, MUL and severity of periurethral/urethral fibrosis. CONCLUSIONS: The angle of the membranous urethra as a result of anchoring of the BN and EUS in the PF appears to be an important functional factor with an essential impact on continence after RP. Functional MRI seems to be a helpful imaging tool for morphologic and dynamic evaluation of the PF.


Asunto(s)
Diafragma Pélvico/patología , Prostatectomía/efectos adversos , Neoplasias de la Próstata/cirugía , Uretra/patología , Vejiga Urinaria/patología , Incontinencia Urinaria de Esfuerzo/patología , Anciano , Estudios de Casos y Controles , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Diafragma Pélvico/fisiopatología , Estudios Prospectivos , Neoplasias de la Próstata/patología , Vejiga Urinaria/fisiopatología , Incontinencia Urinaria de Esfuerzo/etiología
9.
Eur Urol Focus ; 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38839508

RESUMEN

BACKGROUND AND OBJECTIVE: Several minimally invasive treatments have been developed to treat benign prostatic obstruction (BPO) via a transurethral approach, with a non-negligible risk of complications such as urethral stricture and external sphincter damage. Our aim was to present the Gozzi surgical technique for suprapubic transvesical adenoma resection of the prostate (STAR-P) for BPO and to assess its safety, feasibility, and outcomes. METHODS: We conducted a retrospective analysis of 44 consecutive patients who underwent STAR-P for BPO. All the procedures were performed in a single private hospital by one surgeon from 2020 to 2022. An innovative resectoscope designed by the surgeon was subsequently produced by Tontarra Medizintechnik (Wurmlingen, Germany) with a 42.06 Fr external sheath that allows the use of loops of three different sizes. The instrument is inserted into the bladder via suprapubic access, which ensures greater freedom of movement without compromising the external sphincter. Clinical data were retrospectively collected. Preoperative and intraoperative variables, postoperative complications, and functional outcomes of the STAR-P procedure were assessed. A descriptive statistical analysis was performed. KEY FINDINGS AND LIMITATIONS: No intraoperative complications were observed. Two patients (4.5%) experienced urinary urgency symptoms after catheter removal that resolved within 90 d. Median times were 105 min for surgery overall and 65 min for resection. All patients showed an improvement in voiding quality. CONCLUSIONS AND CLINICAL IMPLICATIONS: STAR-P is a safe, feasible, and cost-effective procedure that spares the bulbomembranous and penile urethra and the external urethral sphincter, and should be discussed with patients as a possible option for treatment of BPO. PATIENT SUMMARY: We describe a new, safe, and feasible technique for surgical treatment of urinary obstruction caused by a large prostate. Keyhole surgery is performed through the lower abdomen, which means that the urethra below the prostate is not damaged. Only a small scar of 2-3 cm in the lower abdomen is evident at the end of the healing process.

10.
World J Urol ; 31(3): 629-38, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22710486

RESUMEN

PURPOSE: We prospectively evaluated changes in morphology and dynamics of the male pelvic floor on magnetic resonance imaging (MRI) associated with retrourethral transobturator sling (RTS) placement. PATIENTS AND METHODS: Twenty-six men with post-prostatectomy incontinence consecutively underwent functional cine-MRI before and 12 months after RTS. The membranous urethra length (MUL) and severity of periurethral/urethral fibrosis were assessed on static MRI. A lowering of the posterior bladder wall (BPW), the bladder neck (BN), the external urinary sphincter (EUS) and symphysial rotation of these structures were analysed on dynamic MR images. The success rate was defined as cure (0-1 dry 'security' pad) or improvement (pad reduction ≥ 50 %). RESULTS: The success rate was 77 % (20/26 patients). The mean follow-up was 20.4 months. The MUL significantly increased post-operatively (p < 0.001). There were no significant pre- and post-operative differences in severity of periurethral/urethral fibrosis. Significant elevation of the BPW (p < 0.021), BN and EUS (p < 0.002) was observed post-operatively. The RTS failure was significantly associated with the severity of periurethral fibrosis pre- (p < 0.032) and post-operatively (p < 0.003). CONCLUSIONS: RTS placement is associated with MUL increase, elevation of the BN, BPW and EUS. De novo development of periurethral or urethral fibrosis seems not to be confirmed. The RTS failure was related to the severity of pre- and post-operative periurethral fibrosis. The impact of MRI on pre-operative diagnostics of RTS failure needs further evaluation.


Asunto(s)
Diafragma Pélvico/patología , Diafragma Pélvico/fisiopatología , Cabestrillo Suburetral , Incontinencia Urinaria/cirugía , Procedimientos Quirúrgicos Urológicos Masculinos/métodos , Anciano , Fibrosis , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Prostatectomía/efectos adversos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Resultado del Tratamiento , Uretra/patología , Vejiga Urinaria/patología , Incontinencia Urinaria/etiología
11.
Urol Int ; 90(3): 334-8, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23485964

RESUMEN

OBJECTIVE: To evaluate prospectively the value of the 'repositioning test' (RT) in preoperative patient selection for the efficacy of male stress urinary incontinence (SUI) treatment using a retroluminar transobturator male sling (AdVance sling). PATIENTS AND METHODS: 65 consecutive patients with SUI after radical prostatectomy were included in this single-center prospective study. Preoperatively, patients were classified into those with 'positive' and 'negative' RT. Postoperative results were analyzed and the association between the result of the RT and postoperative outcome was evaluated. RESULTS: 53 patients (81.5%) showed preoperatively a positive RT and 12 patients (18.5%) a negative RT. After a follow-up of 12 months, patients with positive RT showed a cure rate (0 pads/day) of 83% and patients with a negative RT showed only a cure rate of 25%. A positive RT significantly correlated with cure in outcome (p < 0.001). CONCLUSIONS: Patients with positive RT have a significantly better chance for successful AdVance sling implantation. The RT is minimally invasive, easy to learn and easy to perform. Therefore, the RT is a very useful tool for preoperative patient selection.


Asunto(s)
Técnicas de Diagnóstico Urológico , Endoscopía , Selección de Paciente , Cabestrillo Suburetral , Uretra/cirugía , Incontinencia Urinaria de Esfuerzo/diagnóstico , Incontinencia Urinaria de Esfuerzo/cirugía , Procedimientos Quirúrgicos Urológicos Masculinos/instrumentación , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Alemania , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Cuidados Preoperatorios , Estudios Prospectivos , Prostatectomía/efectos adversos , Resultado del Tratamiento , Uretra/fisiopatología , Incontinencia Urinaria de Esfuerzo/etiología , Incontinencia Urinaria de Esfuerzo/fisiopatología , Procedimientos Quirúrgicos Urológicos Masculinos/efectos adversos
13.
World J Urol ; 30(2): 201-6, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21416252

RESUMEN

PURPOSE: Prospective evaluation of independent risk factors for failure of the retrourethral transobturator sling suspension (RTS) with special attention on sphincter function and surgical technique. METHODS: A total of 189 patients with postprostatectomy stress urinary incontinence (SUI) were treated with RTS (AdVance(®) sling) in a prospective clinical study with a mean follow-up of 20.8 months. Eleven patients were lost to follow-up. Uni- and multivariate analyses were performed to identify independent risk factors for RTS failure. The success rate was defined as cured (no pad use or one dry 'security' pad) or improved (one to two pads and pad reduction ≥ 50%). RESULTS: At a mean follow-up of 20.8 months, the overall success rate was 73.1%. Multivariate analysis revealed that weak residual function and incomplete closure of the sphincter (OR, 29.0), no elongation of the coaptive sphincter zone (OR, 26.9), no sling tunnelling (OR, 22.6) and use of resorbable sutures with a small number (≤ 4) of stitches (OR, 8.4) are significant predictors for RTS failure. CONCLUSIONS: Preoperative selection of the patients with regard to residual sphincter function and a special attention on better sling fixation may increase RTS efficacy.


Asunto(s)
Complicaciones Posoperatorias/cirugía , Prostatectomía , Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo/cirugía , Procedimientos Quirúrgicos Urológicos Masculinos , Anciano , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Estudios Prospectivos , Factores de Riesgo , Insuficiencia del Tratamiento
14.
World J Urol ; 30(5): 715-21, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21989815

RESUMEN

OBJECTIVE: To evaluate the validity of a single-stage dorsal inlay for recurrent peno-glandular stenosis following previous endourological or open urethroplastic surgery. Urethral glanular reconstruction included a deep dorsal incision followed by complete scar excision to create a deep groove presenting well-vascularized recipient bed ensuring appropriate graft healing. MATERIALS AND METHODS: Between April 2002 and January 2008, a total of 34 patients (mean age 51.5 years, 14-85 years) were enrolled in the study. Congenital anomalies included hypospadia (n = 19, 53%) and epispadia (n = 2, 6%). Condition of strictures was either iatrogenic (n = 7), due to infection (n = 5), or traumatic (n = 1). Foreskin grafts were used in 13 cases, foreskin and buccal mucosa in one case, penile skin in 6 cases, and inguinal skin/thigh (harvested by electrodermatom) in 14 cases. The combination of meticulous scar excision with a deep incision of the glans was used to provide a well-vascularized grafting bed, thus ensuring excellent graft healing. The outcome analysis included urinary flow, urethral calibration >18 ch, voiding cystometry, and patient's satisfaction in a follow-up regime every 3 months. RESULTS: The average graft length was 4.7 cm (median 8, range 1.5-14). Mean follow-up was 70 months. In 31 patients (91%), no recurrent glanular stenosis was observed resulting in a post-operative flow of average 26.2 ml/s (11-53). Three post-operative wound infections occurred resulting in stricture recurrence, which was treated with internal urethrotomy, buccal mucosa, or penile skin inlay, respectively. Cosmetic results were satisfactory in all patients. Post-operative voiding parameters were significantly improved (P < 0.001). CONCLUSION: The single-stage dorsal inlay for reconstruction of peno-glandular stenosis represents a reliable method even if the urethral plate is severely scarred or has been excised during previous surgery. The good results imply that a well-vascularized graft and the technical approach seem to be more important than the substitute material.


Asunto(s)
Hipospadias/cirugía , Enfermedades del Pene/cirugía , Procedimientos de Cirugía Plástica/métodos , Procedimientos de Cirugía Plástica/normas , Uretra/cirugía , Estrechez Uretral/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Constricción Patológica/cirugía , Estudios de Seguimiento , Humanos , Hipospadias/patología , Masculino , Persona de Mediana Edad , Recurrencia , Reoperación/métodos , Reoperación/normas , Trasplante de Piel/métodos , Trasplante de Piel/normas , Uretra/anomalías , Adulto Joven
15.
BJU Int ; 107(12): 1964-6, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21083639

RESUMEN

OBJECTIVE: • To report our experience with a new and simple method of urethral repair with a volar onlay of free labium minus graft. Strictures of the female urethra are rare, and it is well accepted that the therapeutic options of dilation and urethrotomy are not lasting solutions as a result of their high recurrence rates. However, there is no consensus regarding the best way to reconstruct the female urethra in the case of stricture disease. PATIENTS AND METHODS: • Four consecutive female patients with a long lasting history of recurrent urethral strictures underwent open urethroplasty with a volar situated free split thickness epidermal graft from the labium minus. • The surgical technique is described and a short-term follow-up is presented. RESULTS: • Operating time was 40-140 min (mean 105 min), and the graft measured between 2 × 1.5 cm and 3 × 2.5 cm. Follow-up time was 11-19 months. Maximum urinary flow rate could be improved from a baseline of 9.4-11.2 mL/s (preoperatively, after intermittent use of dilation) to 19-23 mL/s. • Postvoid residual urine volume was 0-50 mL preoperatively and no postvoid residual urine volume postoperatively. • Urinary catheters were removed after 21 days. Urinary stress incontinence did not occur postoperatively. No complications related to the graft donor site were found. CONCLUSIONS: • The reported data concerning a new therapeutic approach for the treatment of recurrent female urethral stricture show that a volar onlay urethroplasty represents a feasible, safe and simple surgical method. • Larger series with long-term follow-up are needed for further evaluation.


Asunto(s)
Uretra/cirugía , Estrechez Uretral/cirugía , Procedimientos Quirúrgicos Urológicos/métodos , Vulva/trasplante , Estudios de Factibilidad , Femenino , Humanos , Persona de Mediana Edad , Prevención Secundaria , Resultado del Tratamiento
16.
BJU Int ; 108(1): 94-8, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20883489

RESUMEN

OBJECTIVE: • To evaluate prospectively the efficacy of the retroluminar transobturator male sling (AdVance® sling) for the functional treatment of stress urinary incontinence (SUI) after prostatectomy. PATIENTS AND METHODS: • A total of 137 patients with grade II-IV SUI, resulting from radical prostatectomy, were treated with the AdVance® sling in a prospective clinical study. In all, 11 patients were lost to follow-up. A total of 17 patients (13.5%) had additional adjuvant radiotherapy before sling implantation. • Before and after sling implantation, a standardized 1-h pad test was performed and post-void residual urine, uroflowmetry, quality-of-life scores and the International Index of Erectile Function (IIEF-5) were assessed. • When calculating the cure and improvement rates, 'cure' was defined as no pad use or one dry prophylactic pad; and 'improved' was defined as 1-2 pads or reduction of pads ≥ 50%. RESULTS: • After a median (range) follow-up of 27 (20-37) months, and a mean follow-up of 27.2 months, the success rate was 75.4% with 51.6%'cured' and 23.8%'improved'. • Overall daily pad use, urine loss in the 1-h pad test and quality-of-life scores improved significantly after sling implantation. • Compared with 1-year follow-up data, no worsening over time was noticed and no additional complications were seen. CONCLUSION: • With a mid-term follow-up, the retroluminar transobturator male sling is an effective, safe and attractive treatment option for SUI after radical prostatectomy. Results are stable over time.


Asunto(s)
Prostatectomía/efectos adversos , Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo/cirugía , Anciano , Anciano de 80 o más Años , Métodos Epidemiológicos , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Cabestrillo Suburetral/efectos adversos , Resultado del Tratamiento , Incontinencia Urinaria de Esfuerzo/etiología
17.
BJU Int ; 101(12): 1565-70, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18190621

RESUMEN

OBJECTIVE: To report our initial experience and extended follow-up of single-stage dorsal inlay skin-graft urethroplasty for salvaging recurrent anterior urethral stricture (AUS), as urethral reconstruction remains a challenge, particularly in patients with recurrent AUS after previous surgery, and a paucity of local skin frequently requires free graft reconstruction techniques. PATIENTS AND METHODS: In all, 27 patients (mean age 48.12 years, range 17-79) with recurrent AUS had a dorsal inlay urethroplasty using extragenital split-thickness skin grafts. An electrical dermatome was used for graft harvesting. All patients had contraindications for buccal mucosal grafting (e.g. radiotherapy, leukoplakia). The assessment before repair comprised a clinical investigation, urine analysis, uroflowmetry, retrograde and voiding cystogram, urethral ultrasonography and endoscopy. The follow-up was based on an assessment of flow rate and postvoid residual volume. Success was defined by the absence of symptoms and stable maximum flow rate, while any further instrumentation was considered a failure. RESULTS: The mean (range) stricture length was 8.35 (3-14) cm. The overall complication rate was 7%, with no complications during surgery. During the mean (range) follow-up of 32.43 (5-46) months, 25 (93%) of the patients were successfully cured in one operation. Two patients required further treatment for recurrence and fistula. No long-term complications were noted at the graft donor sites. There was no case of intraurethral hair growth during the extended follow-up. CONCLUSION: If there are contraindications for buccal mucosal grafting, a split-thickness skin can be used for dorsal inlay urethroplasty in recurrent AUS. A well-vascularized recipient bed on the corpora cavernosa is required for reliable graft take. Intra-urethral hair growth is avoided by using split-skin grafts. Although the complication rates are equivalent to those of buccal mucosa, we await the longer follow-up to assess the ultimate value of this alternative single-stage technique.


Asunto(s)
Terapia Recuperativa/métodos , Trasplante de Piel/métodos , Uretra/cirugía , Estrechez Uretral/cirugía , Procedimientos Quirúrgicos Urológicos Masculinos/métodos , Adolescente , Adulto , Anciano , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Recurrencia , Resultado del Tratamiento
18.
Urol Int ; 81(4): 477-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19077414

RESUMEN

UNLABELLED: We present the first case of a metastasizing renal cell carcinoma arising within a partially regressed multicystic dysplastic and ectopic left kidney in a 34-year-old patient. Despite nephrectomy and adjuvant immunotherapy, the patient died 4 months after diagnosis. Even though a recent systematic review found no evidence to support any of the different modalities for following up children with MCKD by ultrasound (Oxford Centre for Evidence-Based Medicine, LEVEL OF EVIDENCE: 3a), our case supports the contrary and we emphasize that an annual control could be an important diagnostic choice ( LEVEL OF EVIDENCE: 4).


Asunto(s)
Carcinoma de Células Renales/diagnóstico , Enfermedades Renales Quísticas/diagnóstico , Neoplasias Renales/diagnóstico , Adulto , Carcinoma de Células Renales/complicaciones , Resultado Fatal , Humanos , Inmunoterapia/métodos , Enfermedades Renales Quísticas/complicaciones , Neoplasias Renales/complicaciones , Masculino , Metástasis de la Neoplasia , Nefrectomía/métodos , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
19.
Int Neurourol J ; 20(4): 335-341, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28043113

RESUMEN

PURPOSE: To evaluate long-term outcomes of AdVance and AdVanceXP male slings in patients with persistent stress urinary incontinence (SUI) after transurethral resection of the prostate (TURP). METHODS: A total of 18 consecutive patients received AdVance (n=14) or AdVanceXP (n=4) male sling implantation between 2007 and 2013. Continence was determined by pad use, 24-hour pad testing and validated questionnaires (International Consultation on Incontinence Questionnaire Short Form, ICIQ-SF). Quality of life was evaluated by International Quality of Life (IQoL) score. Patient satisfaction was measured with patient's global impression of improvement score. Cure was defined as 0-5 g in the 24-hour pad test. Statistical analysis included Fisher exact and Wilcoxon test (P<0.05). RESULTS: Follow-up was available for 15 patients who underwent further analysis. After a median follow-up of 70 months (range, 18-83 months), mean daily pad usage was 1.8±2.1 pads (P=0.015 vs. baseline level). Mean IQoL score was 66.4±31.6 (P=0.050 vs. baseline level), and mean ICIQ-SF score was 9.5±6.6 (P=0.077 vs. baseline level). Based on 24-hour pad testing, mean daily urine loss was 31.2±64.5 g (median, 0 g; range, 0-209 g). Cure rate was 46.7%, and cure-and-improved rate was 60.0%. Assessing predictive features for success, better results were found in patients who needed up to 4 pads preoperatively (P=0.041) as well as for patients ≤71 years at the time of implantation (P=0.041). CONCLUSIONS: The findings indicate that AdVance and AdVanceXP implantation can be performed effectively and safely in men suffering from SUI after TURP. However, long-term success rates seem to be lower compared to SUI after radical prostatectomy and patients should be counseled accordingly.

20.
Int Urol Nephrol ; 47(2): 249-55, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25537826

RESUMEN

PURPOSE: To evaluate the outcome of the retrourethral transobturator sling (RTS) by functional magnetic resonance imaging (MRI) and to identify parameters associated with sling failure. METHODS: Of thirty recruited men with postprostatectomy stress urinary incontinence (SUI), 26 consecutively underwent functional MRI before sling procedure and 12 months thereafter in a prospective clinical cohort observational study. Periurethral/urethral fibrosis and sling visualization were evaluated on static sequences. The angle of the membranous urethra, position of the bladder neck and external urethral sphincter were assessed during Valsalva's maneuver and voiding. Sling success was defined as no or one dry "security" pad. RESULTS: The success and failure rates were 58 % (15/26 patients) and 42 % (11/26 patients), respectively. The sling leads to reduction in the membranous urethra angle during Valsalva's maneuver (39.55° vs. 36.82°, p = 0.025) and voiding (38.25° vs. 34.83°, p = 0.001) and elevation of the external urethral sphincter (2.9 vs. 4.8 mm, p = 0.017). Preoperative wider angle of the membranous urethra was significantly correlated with severe preoperative incontinence. Sling failure (p = 0.001) and severe preoperative incontinence (p = 0.001) were significantly related to only small changes of the membranous urethra angle. The interrater and intrarater reliability for membranous urethra angle was excellent (intraclass correlation coefficient ≥0.75). CONCLUSIONS: The RTS leads to reduction in the membranous urethra angle. The extent of the changes in the membranous urethra angle is associated with RTS outcome. Functional MRI is a reliable noninvasive visualization tool of interactions between the sling and pelvic floor for further research on the complex nature of postprostatectomy SUI.


Asunto(s)
Cabestrillo Suburetral , Uretra/patología , Incontinencia Urinaria de Esfuerzo/cirugía , Anciano , Fibrosis/diagnóstico , Humanos , Imagen por Resonancia Magnética , Masculino , Periodo Posoperatorio , Periodo Preoperatorio , Estudios Prospectivos , Prostatectomía/efectos adversos , Insuficiencia del Tratamiento , Vejiga Urinaria/patología , Incontinencia Urinaria de Esfuerzo/etiología , Micción , Maniobra de Valsalva
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA