Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Semin Cardiothorac Vasc Anesth ; : 10892532241256020, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38842145

RESUMEN

BACKGROUND: This survey aimed to explore the availability and accessibility of echocardiography during noncardiac surgery worldwide. METHODS: An internet-based 45-item survey was sent, followed by reminders from August 30, 2021, to August 20, 2022. RESULTS: 1189 responses were received from 62 countries. Nearly seventy-one percent of respondents had intraoperatively used transesophageal or transthoracic echocardiography (TEE and TTE, respectively) for monitoring or examination. The unavailability of echocardiography machines (30.3%), lack of trained personnel (30.2%), and absence of clinical indications (22.6%) were the top 3 reasons for not using intraoperative echocardiography in noncardiac surgery. About 61.5% of participants had access to at least one echocardiography machine. About 41% had access to at least 1 TEE probe, and 62.2% had access to at least 1 TTE probe. Seventy-four percent of centers had a procedure to request intraoperative echocardiography if needed for noncardiac cases. Intraoperative echocardiography service was immediately available in 58% of centers. CONCLUSIONS: Echocardiography machines and skilled echocardiographers are still unavailable at many centers worldwide. National societies should aim to train a critical mass of certified TEE/TTE anesthesiologists and provide all anesthesiologists access to perioperative TEE/TTE machines in anesthesiology departments, considering the increasing number of older and sicker surgical patients scheduled for noncardiac surgery.

2.
Artículo en Inglés | CONASS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1555487

RESUMEN

BACKGROUND: This survey aimed to explore the availability and accessibility of echocardiography during noncardiac surgery worldwide. METHODS: An internet-based 45-item survey was sent, followed by reminders from August 30, 2021, to August 20, 2022. RESULTS: 1189 responses were received from 62 countries. Nearly seventy-one percent of respondents had intraoperatively used transesophageal or transthoracic echocardiography (TEE and TTE, respectively) for monitoring or examination. The unavailability of echocardiography machines (30.3%), lack of trained personnel (30.2%), and absence of clinical indications (22.6%) were the top 3 reasons for not using intraoperative echocardiography in noncardiac surgery. About 61.5% of participants had access to at least one echocardiography machine. About 41% had access to at least 1 TEE probe, and 62.2% had access to at least 1 TTE probe. Seventy-four percent of centers had a procedure to request intraoperative echocardiography if needed for noncardiac cases. Intraoperative echocardiography service was immediately available in 58% of centers. CONCLUSIONS: Echocardiography machines and skilled echocardiographers are still unavailable at many centers worldwide. National societies should aim to train a critical mass of certified TEE/TTE anesthesiologists and provide all anesthesiologists access to perioperative TEE/TTE machines in anesthesiology departments, considering the increasing number of older and sicker surgical patients scheduled for noncardiac surgery.


Asunto(s)
Ecocardiografía , Ecocardiografía Transesofágica , Atención Perioperativa , Encuestas y Cuestionarios , Cuidados Intraoperatorios
3.
Angiol. (Barcelona) ; 71(4): 123-126, jul.-ago. 2019.
Artículo en Español | IBECS (España) | ID: ibc-190294
4.
Heart Int ; 9(1): 22-5, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-27004093

RESUMEN

The objective of the present work is to describe the experience with intravenous (IV) sildenafil in heart transplant (HT) patients with reactive pulmonary hypertension (PH) who developed right ventricular dysfunction (RVD) in the immediate postoperative period. The first 5 patients who received IV sildenafil followinga HT are presented. The HTs took place between March 2011 and September 2012 in patients aged 37 to 64 years; all patients were male. Prior to the HT, mean pulmonary artery pressure (mPAP) was 32-56 mmHg. In all cases, the hemodynamic study demonstrated PH reactivity (positive vasodilator test with nitric oxide). All 5 patients developed RVD with hemodynamic instability immediately after the HT, despite the administration of nitric oxide from the time of intubation prior to the implant, optimal medical treatment in all cases, and a ventricular assist in 2 cases. In all patients, IV sildenafil was initiated at 10 mg/8 h for 48 h and was subsequently increased to 20 mg/8 h. in its oral formulation until discharge from the hospital. The change in pulmonary pressure was assessed using a Swan-Ganz catheter. Ventricular function was assessed using echocardiography. Length of stay in the Resuscitation Unit and mid-term survival were also assessed. Average time of extracorporeal circulation was 200 ± 110 min and organ ischemic time was 210 ± 95 min. All of the patients demonstrated pulmonary and systemic hemodynamic improvement, as well as recovery of right ventricular function after completing the treatment with IV sildenafil. The stay in the Resuscitation Unit lasted 3-25 days. All the patients were discharged from hospital with no mortality to date. Intravenous sildenafil improves right ventricle hemodynamics associated with pulmonary hypertension post-HT. Prophylactic prevention with this drug could be indicated for patients with reactive PH who are about to receive a transplant.

5.
Rev Esp Cardiol ; 63(7): 869-70, 2010 Jul.
Artículo en Inglés, Español | MEDLINE | ID: mdl-23020948
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA