Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Magn Reson ; 354: 107523, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37625202

RESUMEN

Landau-Zener-Stückelberg-Majorana (LZSM) transitions occur between quantum states when parameters in the system's Hamiltonian are varied continuously and rapidly. In magnetic resonance, losses in adiabatic rapid passage can be understood using the physics of LZSM transitions. Most treatments of LZSM transitions ignore the T2 dephasing of coherences, however. Motivated by ongoing work in magnetic resonance force microscopy, we employ the Bloch equations, coordinate transformation, and the Magnus expansion to derive expressions for the final magnetization following a rapid field sweep at fixed irradiation intensity that include T2 losses. Our derivation introduces an inversion-function, Fourier transform method for numerically evaluating highly oscillatory integrals. Expressions for the final magnetization are given for low and high irradiation intensity, valid in the T2≪T1 limit. Analytical results are compared to numerical simulations and nuclear magnetic resonance experiments. Our relatively straightforward calculation reproduces semiquantitatively the well known LZSM result in the T2→0 limit.

2.
Proc Natl Acad Sci U S A ; 106(52): 22251-6, 2009 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-20018707

RESUMEN

We report an approach that extends the applicability of ultrasensitive force-gradient detection of magnetic resonance to samples with spin-lattice relaxation times (T (1)) as short as a single cantilever period. To demonstrate the generality of the approach, which relies on detecting either cantilever frequency or phase, we used it to detect electron spin resonance from a T (1) = 1 ms nitroxide spin probe in a thin film at 4.2 K and 0.6 T. By using a custom-fabricated cantilever with a 4 microm-diameter nickel tip, we achieve a magnetic resonance sensitivity of 400 Bohr magnetons in a 1 Hz bandwidth. A theory is presented that quantitatively predicts both the lineshape and the magnitude of the observed cantilever frequency shift as a function of field and cantilever-sample separation. Good agreement was found between nitroxide T (1) 's measured mechanically and inductively, indicating that the cantilever magnet is not an appreciable source of spin-lattice relaxation here. We suggest that the new approach has a number of advantages that make it well suited to push magnetic resonance detection and imaging of nitroxide spin labels in an individual macromolecule to single-spin sensitivity.


Asunto(s)
Óxidos N-Cíclicos/química , Espectroscopía de Resonancia por Spin del Electrón/métodos , Marcadores de Spin , Fenómenos Biofísicos , Espectroscopía de Resonancia por Spin del Electrón/instrumentación , Espectroscopía de Resonancia por Spin del Electrón/estadística & datos numéricos , Diseño de Equipo , Espectroscopía de Resonancia Magnética , Microondas , Estructura Molecular , Termodinámica
3.
J Magn Reson ; 162(2): 336-40, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12810017

RESUMEN

We demonstrate one-dimensional nuclear magnetic resonance imaging of the semiconductor GaAs with 170 nm slice separation and resolve two regions of reduced nuclear spin polarization density separated by only 500 nm. This was achieved by force detection of the magnetic resonance, magnetic resonance force microscopy (MRFM), in combination with optical pumping to increase the nuclear spin polarization. Optical pumping of the GaAs created spin polarization up to 12 times larger than the thermal nuclear spin polarization at 5K and 4T. The experiment was sensitive to sample volumes of 50 microm(3) containing approximately 4 x 10(11)71 Ga/Hz. These results demonstrate the ability of force-detected magnetic resonance to apply magnetic resonance imaging to semiconductor devices and other nanostructures.

4.
ACS Nano ; 4(12): 7141-50, 2010 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-21082863

RESUMEN

We have batch-fabricated cantilevers with ∼100 nm diameter nickel nanorod tips and force sensitivities of a few attonewtons at 4.2 K. The magnetic nanorods were engineered to overhang the leading edge of the cantilever, and consequently the cantilevers experience what we believe is the lowest surface noise ever achieved in a scanned probe experiment. Cantilever magnetometry indicated that the tips were well magnetized, with a ≤ 20 nm dead layer; the composition of the dead layer was studied by electron microscopy and electron energy loss spectroscopy. In what we believe is the first demonstration of scanned probe detection of electron-spin resonance from a batch-fabricated tip, the cantilevers were used to observe electron-spin resonance from nitroxide spin labels in a film via force-gradient-induced shifts in cantilever resonance frequency. The magnetic field dependence of the magnetic resonance signal suggests a nonuniform tip magnetization at an applied field near 0.6 T.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Magnetismo , Fenómenos Mecánicos , Nanotecnología/métodos , Espectroscopía de Resonancia por Spin del Electrón , Estudios de Factibilidad , Microscopía Electrónica , Níquel/química , Silicio/química , Espectroscopía de Pérdida de Energía de Electrones
5.
Appl Phys Lett ; 97(4)2010 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-20733934

RESUMEN

We introduce and demonstrate a method of measuring small force gradients acting on a harmonic oscillator in which the force-gradient signal of interest is used to parametrically up-convert a forced oscillation below resonance into an amplitude signal at the oscillator's resonance frequency. The approach, which we demonstrate in a mechanically detected electron spin resonance experiment, allows the force-gradient signal to evade detector frequency noise by converting a slowly modulated frequency signal into an amplitude signal.

6.
Appl Microbiol Biotechnol ; 76(3): 561-8, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17562040

RESUMEN

Effects of select electron mediators [9,10-anthraquinone-2,6-disulfonic acid disodium salt (AQDS), safranine O, resazurin, methylene blue, and humic acids] on metabolic end-products and current production from cellulose digestion by Clostridium cellulolyticum in microbial fuel cells (MFCs) were studied using capillary electrophoresis and traditional electrochemical techniques. Addition of the mediator resazurin greatly enhanced current production but did not appear to alter the examined fermentation end-products compared to MFCs with no mediator. Assays for lactate, acetate, and ethanol indicate that the presence of safranine O, methylene blue, and humic acids alters metabolite production in the MFC: safranine O decreased the examined metabolites, methylene blue increased lactate formation, and humic acids increased the examined metabolites. Mediator standard redox potentials (E (0)) reported in the literature do not coincide with redox potentials in MFCs due presumably to the electrolytic complexity of media that supports bacterial survival and growth. Current production in MFCs: (1) can be effected by the mediator redox potential while in the media, which may be significantly shifted from E (0), and (2) depended on the ability of the mediator to access the bacterial electron source, which may be cytoplasmic. In addition, some electron mediators had significant effects on metabolic end-products and therefore the metabolism of the organism itself.


Asunto(s)
Fuentes de Energía Bioeléctrica/microbiología , Antraquinonas/farmacología , Biotecnología , Celulosa/metabolismo , Clostridium cellulolyticum/efectos de los fármacos , Clostridium cellulolyticum/metabolismo , Electroquímica , Transporte de Electrón/efectos de los fármacos , Fermentación/efectos de los fármacos , Sustancias Húmicas/toxicidad , Azul de Metileno/farmacología , Oxazinas/farmacología , Oxidación-Reducción , Fenazinas/farmacología , Xantenos/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA