Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Arthroscopy ; 40(1): 136-145, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37355187

RESUMEN

PURPOSE: To investigate the biomechanical effects of tape-reinforced graft suturing and graft retensioning for all-soft tissue quadriceps tendon (ASTQT) anterior cruciate ligament reconstruction (ACLR) in a full-construct human cadaveric model. METHODS: Harvested cadaveric ASTQT grafts were assigned to either (1) double-suspensory adjustable-loop cortical button device (ALD) fixation in which both graft ends were fixed with a suspensory fixation device with (n = 5) or without (n = 5) tape-reinforced suturing or (2) single-suspensory distal tendon fixation in which only the patellar end was fixed with an ALD (n = 5) or fixed-loop cortical button device (FLD) (n = 5). All specimens were prepared using a No. 2 whipstitch technique, and tape-reinforced specimens had an integrated braided tape implant. Graft preparation time was recorded for double-suspensory constructs. Samples were tested on an electromechanical testing machine using a previously published protocol simulating rehabilitative kinematics and loading. RESULTS: Tape-reinforced graft suturing resulted in greater graft load retention after cycling (11.9% difference, P = .021), less total elongation (mean [95% confidence interval (CI)], 5.57 mm [3.50-7.65 mm] vs 32.14 mm [25.38-38.90 mm]; P < .001), greater ultimate failure stiffness (mean [95% CI], 171.9 N/mm [158.8-185.0 N/mm] vs 119.4 N/mm [108.7-130.0 N/mm]; P < .001), and less graft preparation time (36.4% difference, P < .001) when compared with unreinforced specimens. Retensioned ALD constructs had less cyclic elongation compared with FLD constructs (mean total elongation [95% CI], 7.04 mm [5.47-8.61 mm] vs 12.96 mm [8.67-17.26 mm]; P = .004). CONCLUSIONS: Tape-reinforced graft suturing improves time-zero ASTQT ACLR construct biomechanics in a cadaveric model with 83% less total elongation, 44% greater stiffness, and reduced preparation time compared with a whipstitched graft without tape reinforcement. ALD fixation improves construct mechanics when compared with FLD fixation as evidenced by 46% less total elongation. CLINICAL RELEVANCE: Tape-reinforced implants and graft retensioning using ALDs improve time-zero ACLR graft construct biomechanics in a time-zero biomechanical model. Clinical studies will be necessary to determine whether these implants improve clinical outcomes including knee laxity and the incidence of graft rupture.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Humanos , Ligamento Cruzado Anterior/cirugía , Fenómenos Biomecánicos , Autoinjertos , Tendones/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Cadáver
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA