1.
Platelets ; 29(2): 162-170, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28503981

RESUMEN

Despite the interwoven nature of platelet activation and the coagulation system in thrombosis, few studies relate both analysis of protein and cellular parts of coagulation in the same population. In the present study, we use matched ex vivo samples to determine the influences of standard antiplatelet therapies on platelet function and use advanced rheological analyses to assess clot formation. Healthy volunteers were recruited following fully informed consent then treated for 7 days with single antiplatelet therapy of aspirin (75 mg) or prasugrel (10 mg) or with dual antiplatelet therapy (DAPT) using aspirin (75 mg) plus prasugrel (10 mg) or aspirin (75 mg) plus ticagrelor (90 mg). Blood samples were taken at day 0 before treatment and at day 7 following treatment. We found that aspirin plus prasugrel or aspirin plus ticagrelor inhibited platelet responses to multiple agonists and reduced P-selectin expression. Significant platelet inhibition was coupled with a reduction in fractal dimension corresponding to reductions in mean relative mass both for aspirin plus prasugrel (-35 ± 16% change, p = 0.04) and for aspirin plus ticagrelor (-45 ± 14% change, p = 0.04). Aspirin alone had no effect upon measures of clot structure, whereas prasugrel reduced fractal dimension and mean relative mass. These data demonstrate that platelets are important determinants of clot structure as assessed by fractal dimension (df) and that effective platelet inhibition is associated with a weaker, more permeable fibrin network. This indicates a strong association between the therapeutic benefits of antiplatelet therapies and their abilities to reduce thrombus density that may be useful in individual patients to determine the functional relationship between platelet reactivity, eventual clot quality, and clinical outcome. df could represent a novel risk stratification biomarker useful in individualizing antiplatelet therapies.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Plaquetas/metabolismo , Activación Plaquetaria/efectos de los fármacos , Trombosis/metabolismo , Femenino , Fractales , Humanos , Masculino
2.
Artif Organs ; 39(2): 93-101, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25066768

RESUMEN

Implantable ventricular assist devices (VADs) have proven efficient in advanced heart failure patients as a bridge-to-transplant or destination therapy. However, VAD usage often leads to infection, bleeding, and thrombosis, side effects attributable to the damage to blood cells and plasma proteins. Measuring hemolysis alone does not provide sufficient information to understand total blood damage, and research exploring the impact of currently available pumps on a wider range of blood cell types and plasma proteins such as von Willebrand factor (vWF) is required to further our understanding of safer pump design. The extracorporeal CentriMag (Thoratec Corporation, Pleasanton, CA, USA) has a hemolysis profile within published standards of normalized index of hemolysis levels of less than 0.01 g/100 L at 100 mm Hg but the effect on leukocytes, vWF multimers, and platelets is unknown. Here, the CentriMag was tested using bovine blood (n = 15) under constant hemodynamic conditions in comparison with a static control for total blood cell counts, hemolysis, leukocyte death, vWF multimers, microparticles, platelet activation, and apoptosis. The CentriMag decreased the levels of healthy leukocytes (P < 0.006), induced leukocyte microparticles (P < 10(-5) ), and the level of high molecular weight of vWF multimers was significantly reduced in the CentriMag (P < 10(-5) ) all compared with the static treatment after 6 h in vitro testing. Despite the leukocyte damage, microparticle formation, and cleavage of vWF multimers, these results show that the CentriMag is a hemocompatible pump which could be used as a standard in blood damage assays to inform the design of new implantable blood pumps.


Asunto(s)
Corazón Auxiliar/efectos adversos , Animales , Apoptosis , Bovinos , Micropartículas Derivadas de Células/patología , Hemólisis , Humanos , Leucocitos/patología , Ensayo de Materiales , Activación Plaquetaria , Factor de von Willebrand/análisis
3.
Artif Organs ; 37(9): 793-801, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23981196

RESUMEN

Infection is a clinically relevant adverse event in patients with ventricular assist device (VAD) support. The risk of infection could be linked to a reduced immune response resulting from damage to leukocytes during VAD support. The purpose of this study was to develop an understanding of leukocyte responses during the in vitro testing of VADs by analyzing the changes to their morphology and biochemistry. The VentrAssist implantable rotary blood pump (IRBP) and RotaFlow centrifugal pump (CP) were tested in vitro under constant hemodynamic conditions. Automated hematology analysis of samples collected regularly over 25-h tests was undertaken. A new flow cytometric assay was employed to measure biochemical alteration, necrosis (7-AAD) and morphological alteration (CD45 expression) of the circulating leukocytes during the pumping process. The results of hematology analysis show the total leukocyte number and subset counts decreased over the period of in vitro tests dependent on different blood pumps. The percentage of leukocytes damaged during 6-h tests was 40.8 ± 5.7% for the VentrAssist IRBP, 17.6 ± 5.4% for the RotaFlow CP, and 2.7 ± 1.8% for the static control (all n=5). Flow cytometric monitoring of CD45 expression and forward/side scatter characteristics revealed leukocytes that were fragmented into smaller pieces (microparticles). Scanning electron microscopy and imaging flow cytometry were used to confirm this. Device developers could use these robust cellular assays to gain a better understanding of leukocyte-specific VAD performance.


Asunto(s)
Corazón Auxiliar/efectos adversos , Leucocitos/patología , Animales , Bovinos , Micropartículas Derivadas de Células/patología , Micropartículas Derivadas de Células/ultraestructura , Citometría de Flujo , Hemólisis , Antígenos Comunes de Leucocito/análisis , Recuento de Leucocitos , Leucocitos/ultraestructura
4.
Thromb Haemost ; 114(6): 1251-9, 2015 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-26293709

RESUMEN

Venous thromboembolism (VTE) is common in cancer patients, and is the second commonest cause of death associated with the disease. Patients with chronic inflammation, such as cancer, have been shown to have pathological clot structures with modulated mechanical properties. Fractal dimension (df) is a new technique which has been shown to act as a marker of the microstructure and mechanical properties of blood clots, and can be performed more readily than current methods such as scanning electron microscopy (SEM). We measured df in 87 consecutive patients with newly diagnosed lung cancer prior to treatment and 47 matched-controls. Mean group values were compared for all patients with lung cancer vs controls and for limited disease vs extensive disease. Results were compared with conventional markers of coagulation, fibrinolysis and SEM images. Significantly higher values of df were observed in lung cancer patients compared with controls and patients with extensive disease had higher values than those with limited disease (p< 0.05), whilst conventional markers failed to distinguish between these groups. The relationship between df of the incipient clot and mature clot microstructure was confirmed by SEM and computational modelling: higher df was associated with highly dense clots formed of smaller fibrin fibres in lung cancer patients compared to controls. This study demonstrates that df is a sensitive technique which quantifies the structure and mechanical properties of blood clots in patients with lung cancer. Our data suggests that df has the potential to identify patients with an abnormal clot microstructure and greatest VTE risk.


Asunto(s)
Coagulación Sanguínea , Carcinoma de Pulmón de Células no Pequeñas/sangre , Carcinoma de Células Pequeñas/sangre , Fractales , Neoplasias Pulmonares/sangre , Trombofilia/sangre , Anciano , Algoritmos , Biomarcadores , Pruebas de Coagulación Sanguínea , Carcinoma de Pulmón de Células no Pequeñas/complicaciones , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Células Pequeñas/complicaciones , Carcinoma de Células Pequeñas/patología , Estudios de Casos y Controles , Femenino , Fibrina/ultraestructura , Hemorreología , Humanos , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/patología , Masculino , Microscopía Electrónica de Rastreo , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Prospectivos , Riesgo , Método Simple Ciego , Fumar/sangre , Trombofilia/etiología , Tromboembolia Venosa/sangre , Tromboembolia Venosa/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA