Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Eur Heart J ; 39(41): 3715-3723, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30165629

RESUMEN

Aims: Advances of cardiac computed tomography angiography (CTA) have been developed for dose reduction, but their efficacy in clinical practice is largely unknown. This study was designed to evaluate radiation dose exposure and utilization of dose-saving strategies for contrast-enhanced cardiac CTA in daily practice. Methods and results: Sixty one hospitals from 32 countries prospectively enrolled 4502 patients undergoing cardiac CTA during one calendar month in 2017. Computed tomography angiography scan data and images were analysed in a central core lab and compared with a similar dose survey performed in 2007. Linear regression analysis was performed to identify independent predictors associated with dose. The most frequent indication for cardiac CTA was the evaluation of coronary artery disease in 89% of patients. The median dose-length product (DLP) of coronary CTA was 195 mGy*cm (interquartile range 110-338 mGy*cm). When compared with 2007, the DLP was reduced by 78% (P < 0.001) without an increase in non-diagnostic coronary CTAs (1.7% in 2007 vs. 1.9% in 2017 surveys, P = 0.55). A 37-fold variability in median DLP was observed between the hospitals with lowest and highest DLP (range of median DLP 57-2090 mGy*cm). Independent predictors for radiation dose of coronary CTA were: body weight, heart rate, sinus rhythm, tube voltage, iterative image reconstruction, and the selection of scan protocols. Conclusion: This large international radiation dose survey demonstrates considerable reduction of radiation exposure in coronary CTA during the last decade. However, the large inter-site variability in radiation exposure underlines the need for further site-specific training and adaptation of contemporary cardiac scan protocols.


Asunto(s)
Angiografía por Tomografía Computarizada/estadística & datos numéricos , Angiografía Coronaria/estadística & datos numéricos , Dosis de Radiación , Exposición a la Radiación , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Exposición a la Radiación/prevención & control , Exposición a la Radiación/estadística & datos numéricos
2.
JACC Cardiovasc Imaging ; 13(2 Pt 1): 425-434, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31202772

RESUMEN

OBJECTIVES: The aim of this study was to assess the use of low tube potentials for coronary computed tomography angiography (CCTA) in worldwide clinical practice and its influence on radiation exposure, contrast agent volume, and image quality. BACKGROUND: CCTA is frequently used in clinical practice. Lowering of tube potential is a potent method to reduce radiation exposure and to economize contrast agent volume. METHODS: CCTAs of 4,006 patients from 61 international study sites were analyzed regarding very-low (≤80 kVp), low (90 to 100 kVp), conventional (110 to 120 kVp), and high (≥130 kVp) tube potentials. The impact on dose-length product (DLP) and contrast agent volume was analyzed. Image quality was determined by evaluation of the diagnostic applicability and assessment of the objective image parameters signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR). RESULTS: When compared with conventional tube potentials, low tube potentials were used in 56% of CCTAs (≤80 kVp: 9%; 90 to 100 kVp: 47%), which varied among sites from 0% to 100%. Tube potential reduction was associated with low-cardiovascular risk profile, low body mass index (BMI), and new-generation scanners. Median radiation exposure was lowered by 68% or 50% and median contrast agent volume by 25% or 13% for tube potential protocols of ≤80 kVp or 90 to 100 kVp when compared with conventional tube potentials, respectively (all p < 0.001). With the use of lower tube potentials, the frequency of diagnostic scans was maintained (p = 0.41), whereas SNR and CNR significantly improved (both p < 0.001). Considering BMI eligibility criteria, 58% (n = 946) of conventionally scanned patients would have been suitable for low tube potential protocols, and 44% (n = 831) of patients scanned with 90 to 100 kVp would have been eligible for very-low tube potential CCTA imaging of ≤80 kVp. CONCLUSIONS: This large international registry confirms the feasibility of tube potential reduction in clinical practice leading to lower radiation exposure and lower contrast volumes. The current registry also demonstrates that this strategy is still underused in daily practice. (PROspective multicenter registry on radiaTion dose Estimates of cardiac CT angIOgraphy iN daily practice in 2017 [PROTECTION-VI]; NCT02996903).


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Anciano , Medios de Contraste/administración & dosificación , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación/prevención & control , Sistema de Registros , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA