Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Int J Legal Med ; 132(6): 1555-1573, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29523969

RESUMEN

The GlobalFiler™ PCR Amplification Kit is a single multiplex assay that amplifies a set of 24 markers, which encompass the European Standard Set and CODIS (Combined DNA Index System) recommended composite set of loci. In addition to more loci and a 6-dye chemistry format, the Master Mix has been formulated to allow higher sample loading volume for trace DNA samples. The GlobalFiler™ Kit has been optimized to deliver high performance on casework samples, while also delivering fast thermal cycling, with an amplification time of approximately 80 min. Here, we report the results of the developmental validation study which followed the SWGDAM (Scientific Working Group on DNA Analysis Methods) guidelines and includes data for PCR-based studies, sensitivity, species specificity, stability, precision, reproducibility and repeatability, concordance, stutter, DNA mixtures, and performance on mock casework samples. The results validate the multiplex design as well as demonstrate the kit's robustness, reliability, and suitability as an assay for human identification with casework DNA samples.


Asunto(s)
Dermatoglifia del ADN , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa Multiplex/instrumentación , Animales , Huesos/química , Degradación Necrótica del ADN , Frecuencia de los Genes , Humanos , Grupos Raciales/genética , Reproducibilidad de los Resultados , Especificidad de la Especie
2.
Int J Legal Med ; 125(1): 101-9, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20878415

RESUMEN

The AmpFlSTR® NGM™ PCR Amplification Kit enables amplification of 15 autosomal short tandem repeat (STR) loci. The loci are the ten STRs in the SGM Plus® Kit plus the EDNAP and ENSFI recommended STRs D10S1248, D22S1045, D2S441, D1S1656, and D12S391. Allele frequency and other forensically relevant statistics data were generated for the NGM loci in three US population groups (African Americans, Caucasians, and Hispanics). The analyses support that the NGM multiplex is one of the most informative STR multiplex kits available to the forensic science community. At the population level, there are no more detectable departures from expectations of the independence of alleles within as well as between loci than would be expected due to chance, even for the two syntenic loci vWA and D12S391; however, linkage analysis in three large pedigree families shows close linkage between these two loci with a recombination fraction of 0.108. Therefore, in contrast to the practices in calculating the rarity of a DNA profile, for kinship analyses independence between the loci, vWA and D12S391 cannot be assumed.


Asunto(s)
Genética de Población , Secuencias Repetidas en Tándem , Dermatoglifia del ADN/métodos , Frecuencia de los Genes , Ligamiento Genético , Humanos , Reacción en Cadena de la Polimerasa , Grupos Raciales/genética , Estados Unidos
3.
J Forensic Sci ; 52(4): 870-3, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17553078

RESUMEN

The AmpFlSTR MiniFiler polymerase chain reaction amplification kit developed by Applied Biosystems enables size reduction on eight of the larger STR loci amplified in the Identifiler kit, which will aid recovery of information from highly degraded DNA samples. The MiniFiler Kit amplifies CSF1PO, FGA, D2S1338, D7S820, D13S317, D16S539, D18S51, and D21S11 as well as the sex-typing locus amelogenin. A total of 1308 samples were evaluated with both the MiniFiler and Identifiler STR kits: 449 African American, 445 Caucasian, 207 Hispanic, and 207 Asian individuals. Full concordance between Identifiler and MiniFiler Kits was observed in 99.7% (10,437 out of 10,464) STR allele calls compared. The 27 differences seen are listed in Table 1 and encompass the loci D13S317 (n = 14) and D16S539 (n = 10) as well as D18S51 (n = 1), D7S820 (n = 1), and CSF1PO (n = 1). Genotyping discrepancies between the Identifiler and MiniFiler kits were confirmed by reamplification of the samples and further testing using the PowerPlex 16 kit in many cases. DNA sequence analysis was also performed in order to understand the nature of the genetic variations causing the allele dropout or apparent repeat unit shift.


Asunto(s)
Dermatoglifia del ADN/métodos , ADN/genética , Genética Forense/métodos , Repeticiones de Microsatélite/genética , Reacción en Cadena de la Polimerasa/métodos , ADN/química , Dermatoglifia del ADN/normas , Genética Forense/normas , Humanos , Masculino , Reacción en Cadena de la Polimerasa/normas , Análisis de Secuencia de ADN
4.
J Forensic Sci ; 51(5): 1069-73, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17018083

RESUMEN

Stutter products generated during DNA amplification by the polymerase chain reaction (PCR) may complicate mixture interpretation. The PCR amplification of the DYS392 locus typically results in three distinct detectable PCR products: the true allele product (N), a stutter product three bases smaller (N-3), and a reproducible low-level product, three bases larger (N+3). Sequence analysis of the N+3 product demonstrated that its sequence is one TAT repeat longer than the true allele product. Our experiments demonstrated that the quantity of both N-3 and N+3 stutter increased as the allele number increased. The percent stutter also increased as the magnesium concentration was increased in the reaction, as well as when the amount of input DNA was decreased. As both stutter products behave in a similar and reproducible fashion, the same rules that apply to the interpretation of N-3 stutter products in short tandem repeat analysis, can be applied to N+3 stutters. The characterization of the DYS392 N+3 product is the first detailed published study of a stutter product larger than the true allele.


Asunto(s)
Cromosomas Humanos Y , Repeticiones de Trinucleótidos , Cartilla de ADN , Medicina Legal , Humanos , Cloruro de Magnesio , Masculino , Reacción en Cadena de la Polimerasa
5.
J Forensic Sci ; 51(2): 344-8, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16566768

RESUMEN

During an extensive multipopulation study with Y-short tandem repeat (STR) loci, amplified using the AmpFlSTR Yfiler PCR amplification kit, amplification of a 71 bp fragment was observed in 2.32% of the male samples analyzed (N = 3141). By direct sequencing of this fragment, it was determined that the primer binding sequences were identical to those of the DYS456 locus. A T to G single-nucleotide polymorphism (SNP) enabled amplification of the 71 bp fragment. The SNP is located within an X-Y homologous region at Xq21.31 and was observed with the highest frequency within the African American and Sub-Saharan African populations in our study. Presence of SNP on the X chromosome did not interfere with the reliability of typing the DYS456 locus and the other Y-STR loci typeable using the AmpFlSTR Yfiler PCR amplification kit. Full profiles in a mixture of male:female at 1:4000 were obtained using the current configuration of the AmpFlSTR Yfiler kit even in the presence of female DNA containing the G variant.


Asunto(s)
Cromosomas Humanos X , Dermatoglifia del ADN , Polimorfismo de Nucleótido Simple , Secuencias Repetidas en Tándem , Cromosomas Humanos Y , Cartilla de ADN , Femenino , Frecuencia de los Genes , Humanos , Masculino , Mutación , Reacción en Cadena de la Polimerasa , Grupos Raciales/genética , Análisis de Secuencia de ADN
6.
J Forensic Sci ; 51(1): 64-75, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16423225

RESUMEN

In the past 5 years, there has been a substantial increase in the use of Y-short tandem repeat loci (Y-STRs) in forensic laboratories, especially in cases where typing autosomal STRs has met with limited success. The AmpFlSTR Yfiler PCR amplification kit simultaneously amplifies 17 Y-STR loci including the loci in the "European minimal haplotype" (DYS19, DYS385a/b, DYS389I, DYS389II, DYS390, DYS391, DYS392, and DYS393), the Scientific Working Group on DNA Analysis Methods (SWGDAM) recommended Y-STR loci (DYS438 and DYS439), and the highly polymorphic loci DYS437, DYS448, DYS456, DYS458, Y GATA H4, and DYS635 (formerly known as Y GATA C4). The Yfiler kit was validated according to the FBI/National Standards and SWGDAM guidelines. Our results showed that full profiles are attainable with low levels of male DNA (below 125 pg) and that under optimized conditions, no detectable cross-reactive products were obtained on human female DNA, bacteria, and commonly encountered animal species. Additionally, we demonstrated the ability to detect male specific profiles in admixed male and female blood samples at a ratio of 1:1000.


Asunto(s)
Cromosomas Humanos Y , Dermatoglifia del ADN/métodos , Secuencias Repetidas en Tándem , Animales , Gatos/genética , Dermatoglifia del ADN/normas , Cartilla de ADN , Perros/genética , Genética de Población , Humanos , Masculino , Pan troglodytes/genética , Reacción en Cadena de la Polimerasa , Grupos Raciales/genética , Reproducibilidad de los Resultados , Especificidad de la Especie
7.
J Forensic Sci ; 50(4): 809-25, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16078482

RESUMEN

The Quantifiler Human DNA Quantification Kit and the Quantifiler Y Human Male DNA Quantification Kit were designed for the quantification of human genomic DNA in forensic samples. The kits use a real-time PCR-based process to quantify, respectively, total human DNA or human male DNA only. We report the results of a developmental validation study that we performed with the Quantifiler Kits, following the official SWGDAM guidelines. The Quantifiler Kits were tested for performance criteria such as species specificity, sensitivity, stability, precision and accuracy, and in addition, were tested with forensic case-type samples and mixed (male:female) DNA samples. The Quantifiler Kit methods were highly specific for human DNA, and could detect as little as 32 picograms of DNA using 2 microL of sample per assay. The accuracy and precision of the Quantifiler Kit methods was comparable or superior to that of other quantification methods.


Asunto(s)
Dermatoglifia del ADN/métodos , ADN/aislamiento & purificación , Reacción en Cadena de la Polimerasa/métodos , Animales , Cromosomas Humanos Y , Cartilla de ADN , Etnicidad/genética , Femenino , Marcadores Genéticos , Humanos , Masculino , Reproducibilidad de los Resultados , Especificidad de la Especie
8.
Forensic Sci Int Genet ; 19: 148-155, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26226223

RESUMEN

In order to increase the power of discrimination, reduce the possibility of adventitious matches, and expand global data sharing, the CODIS Core Loci Working Group made a recommendation to expand the CODIS core loci from the "required" 13 loci to 20 plus three additional "highly recommended" loci. The GlobalFiler(®) Express Kit was designed to incorporate all 20 required and 3 highly recommended loci along with a novel male-specific Y insertion/deletion marker. The GlobalFiler(®) Express Kit allows simultaneous amplification of the following loci: D3S1358, vWA, D16S539, CSF1PO, TPOX, Yindel, AMEL, D8S1179, D21S11, D18S51, DYS391, D2S441, D19S433, TH01, FGA, D22S1045, D5S818, D13S317, D7S820, SE33, D10S1248, D1S1656, D12S391, and D2S1338. The kit enables direct amplification from blood and buccal samples stored on paper or swab and the chemistry features an optimized PCR protocol that yields time to results in less than an hour. Developmental validation testing followed SWGDAM guidelines and demonstrated the quality and robustness of the GlobalFiler(®) Express Kit over a number of variables. The validation results demonstrate that the 24-locus multiplex kit is a robust and reliable identification assay as required for forensic DNA typing and databasing.


Asunto(s)
Colorantes/química , Reacción en Cadena de la Polimerasa/instrumentación , Animales , Humanos , Límite de Detección , Nucleótidos/análisis , Reacción en Cadena de la Polimerasa/métodos , Reproducibilidad de los Resultados , Especificidad de la Especie
9.
Forensic Sci Int Genet ; 16: 181-194, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25621924

RESUMEN

UNLABELLED: Short tandem repeat (STR) DNA typing is a global standard for human identification. Current practice involves highly trained forensic analysts, operating in a laboratory setting, using multiple instruments to process samples and analyze the data. Here, we report the developmental validation of a fully integrated and automated DNA profiling system, the RapidHIT® System, capable of producing up to five high quality STR profiles with full controls in approximately 90min using PowerPlex®16 HS RapidHIT chemistry. The system integrates all sample handling steps: starting from lysis of cells on buccal swabs or other buccal sample types through DNA extraction, normalization, amplification,capillary array electrophoresis, detection, and integrated software analysis. The results describe the developmental validation of the RapidHIT™ System for buccal samples processed with the DNA IQ™ extraction chemistry using a guandinium chaotropic agent and paramagnetic beads followed by amplification using a modified version of PowerPlex 16 HS chemistry (PowerPlex 16 HS RapidHIT chemistry), and capillary electrophoresis with manual review of genotyping data following interpretation guidelines. All processing from the buccal swab to generation and processing of the profile occurs on the RapidHIT platform. RESULT: are concordant with traditional methods, with 88% first pass success rates for both the CODIS and PowerPlex 16 loci. Average peak height ratios were 0.89 for buccal swabs. The system produces full profiles from swabs with at least 176 ng of saliva DNA. Rapid DNA identification systems will significantly enhance capabilities for forensic labs, intelligence, defense, law enforcement, refugee and immigration applications, and kinship analysis.


Asunto(s)
Antropología Forense , Mucosa Bucal/metabolismo , Humanos , Repeticiones de Microsatélite/genética , Reacción en Cadena de la Polimerasa , Reproducibilidad de los Resultados
10.
J Forensic Sci ; 49(6): 1265-77, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15568700

RESUMEN

Analysis of length polymorphism at short tandem repeat (STR) loci utilizing the polymerase chain reaction (PCR) process has proven to be an ideal assay for human identification purposes. The short length of STR loci coupled with the amplification of target sequence through PCR allows for a robust, sensitive, and specific assay for highly polymorphic markers. A multiplex containing fifteen STR loci plus the gender-determining locus Amelogenin was developed to provide a single amplification/detection of all CODIS (Combined DNA Index System) STR loci (CSF1PO, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, FGA, TH01, TPOX, and vWA) as well as two internationally-accepted STRs (D2S1338 and D19S433). By incorporating five-dye fragment analysis technology and non-nucleotide linkers, previously optimized AmpFlSTR kit primer sequences have been maintained. This kit has been developed in accordance with the standards of the forensic community as defined by the DNA Advisory Board. Validation studies were performed to include developmental validation, and the results support the use of the AmpFlSTR Identifiler PCR Amplification Kit for human identity and parentage testing.


Asunto(s)
Dermatoglifia del ADN/métodos , Reacción en Cadena de la Polimerasa/métodos , Secuencias Repetidas en Tándem , Animales , Bacterias/genética , Gatos , Bovinos , Pollos , Cartilla de ADN , Desoxirribonucleótidos , Perros , Genotipo , Caballos , Humanos , Indicadores y Reactivos , Cloruro de Magnesio , Ratones , Polimorfismo Genético , Cloruro de Potasio , Análisis de Secuencia de ADN , Especificidad de la Especie , Porcinos , Temperatura , Levaduras/genética
11.
Forensic Sci Int Genet ; 13: 247-58, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25240155

RESUMEN

Rapid DNA typing provides a transformative solution to help forensic laboratories and law enforcement agencies solve and prevent crimes. The RapidHIT(®) System is a fully integrated instrument with a simplified user interface enabling an operator to run the system and obtain a DNA profile from a sample in less than two hours. The integration and developmental validation of the NDIS-approved 24 loci GlobalFiler(®) Express kit expands the capabilities of the RapidHIT System to increase discrimination power, reduce adventitious matches, and improve cross-border data sharing capabilities. Developmental validation studies were performed according to the SWGDAM guidelines and tested several critical areas of performance including three sensitivity studies, inhibited samples, thermal cycling parameters, and cross-contamination. Validation studies indicate that the optimized PCR parameters and sensitivity of the system is capable of generating STR profiles from buccal or blood swab reference samples. Results were concordant with genotypes produced using standard bench thermal cyclers and capillary electrophoresis platforms. Furthermore, swabs can be retrieved from the system and re-run or reprocessed with traditional bench chemistries, e.g. Y-STRs, to gain additional information. Our results demonstrate that the GlobalFiler Express assay run on the RapidHIT System is reliable for generating profiles from reference samples after forensic review.


Asunto(s)
Dermatoglifia del ADN/instrumentación , Dermatoglifia del ADN/métodos , Marcadores Genéticos , Repeticiones de Microsatélite , Animales , Artefactos , ADN/aislamiento & purificación , Electroforesis Capilar , Femenino , Humanos , Masculino , Reacción en Cadena de la Polimerasa , Especificidad de la Especie , Temperatura de Transición
12.
Leg Med (Tokyo) ; 16(1): 26-32, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24296037

RESUMEN

Bi-Allelic Insertions and Deletions (INDELs) are a powerful set of genetic markers for Human Identification (HID). They have certain desirable features, such as low mutation rates, no stutter, and potentially small amplicon sizes that could prove effective in some circumstances. In this study, we analyzed the distribution of 114 INDELs in four North American populations (Caucasian, African American, Southwest Hispanic, and Asian) to estimate their distribution in major global populations. Of the 114 INDELs a primary panel of 38 candidate markers was selected that met the criteria of (1) a minimum allele frequency of greater than 0.20 across the populations studied; (2) general concordance with Hardy-Weinberg equilibrium (HWE) expectations; (3) relatively low FST based on the major populations; (4) physical distance between markers greater than 40 Mbp; and (5) a lack of linkage disequilibria between syntenic markers. Additionally, another 11 supplemental markers were selected for an expanded panel of 49 markers which met the above criteria, with the exception that they are separated at least by 20 Mbp. The resulting panels had Random Match Probabilities that were at least 10(-16) and 10(-19), respectively, and combined FST values of approximately 0.02. Given these findings, these INDELs should be useful for HID.


Asunto(s)
Mutación INDEL , Polimorfismo Genético/genética , Pueblo Asiatico/genética , Marcadores Genéticos , Genética de Población , Técnicas de Genotipaje , Humanos , América del Norte , Polimorfismo de Nucleótido Simple
13.
Forensic Sci Int Genet ; 7(1): 41-51, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22742953

RESUMEN

The AmpFℓSTR(®) NGM SElect™ PCR Amplification Kit is a new 17-plex STR genotyping kit designed for use primarily in forensic casework analysis. The kit was designed to be a counterpart to the AmpFℓSTR(®) NGM™ Kit for laboratories wishing to add the SE33 locus to the new European Standard Set of STR loci. The NGM SElect Kit shares the same primer sets for 16 common loci with the NGM Kit (D10S1248, D3S1358, vWA, D16S539, D2S1338, amelogenin, D8S1179, D21S11, D18S51, D19S433, TH01, FGA, D22S1045, D2S441, D1S1656 and D12S391), with additional primers for the SE33 locus. Developmental validation studies followed the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines for STR kit manufacturers and tested several critical areas of kit performance including a sensitivity series, DNA mixtures and inhibited samples. The studies demonstrated that the NGM SElect Kit provides equivalent overall performance to the NGM Kit, but with even greater discriminatory power due to the inclusion of the highly informative SE33 locus.


Asunto(s)
Mapeo Cromosómico , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa/instrumentación , ADN/genética , Femenino , Genética de Población , Genotipo , Humanos , Masculino
14.
Forensic Sci Int Genet ; 6(3): 310-6, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-21757416

RESUMEN

SE33 is one of the most informative markers in forensic use due to its high power of discrimination. During the course of developing the AmpFℓSTR(®) NGM SElect™ PCR Amplification Kit several SE33 primer designs were screened with one primer pair yielding a high frequency of discordant alleles when compared to the AmpFℓSTR(®) SEfiler Plus™ PCR Amplification Kit. This discordance was mostly specific to samples of African descent with an estimated frequency of 5.1% and was a result of a mobility shift of approximately +0.84nt. The sequence analysis of the affected alleles revealed that the only difference from the wild type sequence was a single nucleotide polymorphism (SNP) outside of the SE33 repeat but within the amplicon of this particular set of experimental primers. In total, we identified three different SNPs all within 9nt of each other, each of which could cause the mobility shift individually. Further characterization of this region via site directed mutagenesis and thermostability measurements strongly suggests that this polymorphic region contains a secondary structure that, when disrupted due to the presence of a variant SNP, results in a mobility shift relative to the wild type sequence. To overcome this problem, the SE33 primers used in the final configuration of the NGM SElect™ Kit avoided the amplification of this polymorphic region yielding in turn results highly concordant with the SEfiler Plus™ Kit.


Asunto(s)
Cartilla de ADN , Electroforesis , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa/métodos , Alelos , Población Negra/genética , Dermatoglifia del ADN , Femenino , Genotipo , Humanos , Secuencias Invertidas Repetidas , Masculino , Mutagénesis Sitio-Dirigida , Reacción en Cadena de la Polimerasa/instrumentación , Polimorfismo de Nucleótido Simple , Análisis de Secuencia de ADN , Termodinámica , Población Blanca/genética
15.
J Forensic Sci ; 57(2): 453-65, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22074494

RESUMEN

Analysis of length polymorphism at short tandem repeat (STR) loci utilizing multiplex polymerase chain reaction (PCR) remains the primary method for genotyping forensic samples. The AmpFℓSTR(®) Identifiler(®) Plus PCR Amplification Kit is an improved version of the AmpFℓSTR(®) Identifiler(®) PCR Amplification Kit and amplifies the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex-determinant, amelogenin, and two internationally accepted loci, D2S1338 and D19S433. While the primer sequences and dye configurations were unchanged, the AmpFℓSTR(®) Identifiler(®) Plus PCR Amplification Kit features an enhanced buffer formulation and an optimized PCR cycling protocol that increases sensitivity, provides better tolerance to PCR inhibitors, and improves performance on mixture samples. The AmpFℓSTR(®) Identifiler(®) Plus PCR Amplification Kit has been validated according to the FBI/National Standards and Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines. The validation results support the use of the AmpFℓSTR(®) Identifiler(®) Plus PCR Amplification Kit for human identity and parentage testing.


Asunto(s)
Dermatoglifia del ADN/instrumentación , Reacción en Cadena de la Polimerasa/instrumentación , Animales , Degradación Necrótica del ADN , Cartilla de ADN , Electroforesis , Frecuencia de los Genes , Genética de Población , Genotipo , Humanos , Repeticiones de Microsatélite , Primates/genética , Grupos Raciales , Especificidad de la Especie
16.
J Forensic Sci ; 57(4): 1022-30, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22390771

RESUMEN

The AutoMate Express™ Forensic DNA Extraction System was developed for automatic isolation of DNA from a variety of forensic biological samples. The performance of the system was investigated using a wide range of biological samples. Depending on the sample type, either PrepFiler™ lysis buffer or PrepFiler BTA™ lysis buffer was used to lyse the samples. After lysis and removal of the substrate using LySep™ column, the lysate in the sample tubes were loaded onto AutoMate Express™ instrument and DNA was extracted using one of the two instrument extraction protocols. Our study showed that DNA was recovered from as little as 0.025 µL of blood. DNA extracted from casework-type samples was free of detectable PCR inhibitors and the short tandem repeat profiles were complete, conclusive, and devoid of any PCR artifacts. The system also showed consistent performance from day-to-day operation.


Asunto(s)
Dermatoglifia del ADN/instrumentación , ADN/aislamiento & purificación , Análisis Químico de la Sangre , Huesos/química , Contaminación de ADN , Células Epiteliales/química , Femenino , Cabello/química , Humanos , Masculino , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa , Reproducibilidad de los Resultados , Saliva/química , Espermatozoides/química , Diente/química
17.
J Forensic Sci ; 56(4): 835-45, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21418220

RESUMEN

The AmpFℓSTR(®) Identifiler(®) Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single-source blood and buccal samples on FTA(®) card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay's sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA(®) cards, and the assay's specificity was verified by establishing minimal cross-reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA(®) substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler(®) Direct Kit for forensic standards and database samples genotyping.


Asunto(s)
Dermatoglifia del ADN/métodos , Repeticiones de Microsatélite , Reacción en Cadena de la Polimerasa , Alelos , Animales , Cartilla de ADN , ADN Bacteriano/genética , Electroforesis Capilar , Frecuencia de los Genes , Heterocigoto , Humanos , Especificidad de la Especie
18.
J Forensic Sci ; 53(4): 838-52, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18540972

RESUMEN

DNA typing of degraded DNA samples can be a challenging task when using the current commercially available multiplex short tandem repeat (STR) analysis kits. However, the ability to type degraded DNA specimens improves by redesigning current STR marker amplicons such that smaller sized polymerase chain reaction (PCR) products are generated. In an effort to increase the amount of information derived from these types of DNA samples, the AmpFlSTR MiniFiler PCR Amplification Kit has been developed. The kit contains reagents for the amplification of eight miniSTRs which are the largest sized loci in the AmpFlSTR Identifiler PCR Amplification Kit (D7S820, D13S317, D16S539, D21S11, D2S1338, D18S51, CSF1PO, and FGA). Five of these STR loci (D16S539, D21S11, D2S1338, D18S51, and FGA) also are some of the largest loci in the AmpFlSTR SGM Plus kit. This informative nine-locus multiplex, which includes the gender-identification locus Amelogenin, has been validated according to the FBI/National Standards and SWGDAM guidelines. Our results demonstrate significant performance improvements in models of DNA degradation, PCR inhibition, and nonprobative samples when compared to the AmpFlSTR Identifiler and SGM Plus kits. These data support that the MiniFiler kit will increase the likelihood of obtaining additional STR information from forensic samples in situations in which standard STR chemistries fail to produce complete profiles.


Asunto(s)
Degradación Necrótica del ADN , Dermatoglifia del ADN/instrumentación , Reacción en Cadena de la Polimerasa , Amelogenina/genética , Animales , Quelantes , ADN/efectos de los fármacos , Cartilla de ADN , Hemina , Humanos , Sustancias Húmicas , Especificidad de la Especie , Secuencias Repetidas en Tándem
19.
Int J Legal Med ; 122(5): 421-7, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18581127

RESUMEN

Null alleles can occur with any PCR-based STR typing system. They generally are due to deletions within the target region or primer binding sites or by primer binding site mutations that destabilize hybridization of at least one of the primers flanking the target region. Although not common, null types were detected at the DYS448 locus in seven out of 1,005 unrelated males in the Hispanic population. Of these DYS448 null types, four individuals displayed an apparent duplication at the DYS437 locus. The additional allele observed at the DYS437 locus is in actuality a smaller-sized DYS448 amplicon, which is the result of a deletion of the invariant N42 base pair domain and downstream repeats within the DYS448 locus. Thus, some DYS448 null types are not truly null. A true DYS448 null allele carried numerous primer binding site variants and a large deletion including the N42 base pair domain and surrounding or downstream repeat regions. The presence of null alleles is not a real concern for interpretation of Y STR loci evidence; current methods for interpreting Y STR profiles easily accommodate such phenomena.


Asunto(s)
Alelos , Cromosomas Humanos Y , Dermatoglifia del ADN , Secuencias Repetidas en Tándem , Haplotipos , Humanos , Masculino , Reacción en Cadena de la Polimerasa , Análisis de Secuencia de ADN
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA